- Medtronic Resolute Onyx Drug Eluting Stent
- Medtronic Onyx Frontier Drug Eluting Stent
- Medtronic Resolute Integrity Drug Eluting Stent
- Medtronic Launcher Guiding Catheter
- Medtronic Telescope Guide Extension Catheter
- Medtronic DxTerity Diagnostic Catheter
- Medtronic Provia Crossing Guidewire
- Medtronic Intuition Guide Wire
- Medtronic Cougar Nitinol Workhorse Guide Wire
- Medtronic Export Advance Aspiration Catheter
Medtronic Coronary Vascular Products
| Brand | Medtronic |
| Approval | FDA,CE |
| Design | Corewire Technology,Powertrac Delivery system |
| Material | Cobalt Chromium Stent,Platinum Iridium core |
| Biolink Polymer | Hydrophilic and biocompatible |
| Strut Thickness | 81microns up to 4mm diameter & 91 microns for 4.5 & 5mm diameter |
| Rated Burst Pressure | 18 atm |
Resolute Onyx, Zotarolimus Drug Eluting stent is composed of a single wire strand formed into a continuous sinusoidal waveform, providing a fluid range of motion with greater flexibility. The platinum iridium core within Resolute Onyx DES increases radiopacity for accurate stent placement. The Resolute Onyx DES is the first-and-only DES that has been proven safe and effective utilizing a one-month regimen of DAPT following a PCI in patients at (HBR) high bleeding risk.
Resolute Onyx™ drug-eluting stent (DES) is a stent and balloon catheter delivery system designed to be placed inside a diseased coronary artery to keep the artery open so that blood can access the heart.
Indicated For HBR Patients With 1-Month Dapt Labeling
Resolute Onyx is the only DES proven safe and effective in high bleeding risk (HBR) patients with 1-month DAPT labeling, based on results from the Onyx ONE Clear Analysis.
The Only Des Designed From A Single Wire†
Resolute Onyx DES is composed of a single wire strand formed into a continuous sinusoidal waveform, providing a fluid range of motion with greater flexibility and conformability when compared to laser-cut stents.
Single Wire Design Benefits
Single wire design increases deliverability, flexibility, conformability, wall-apposition, and may reduce arterial injury and thrombus formation.
The Only Des With Truly Rounded Struts
Resolute Onyx DES is designed with rounded struts that may create a smooth passage for side branch access.
View Complete Details
| Brand | Medtronic |
| Model Name/Number | Onyx Frontier |
| Usage/Application | Hospital |
| Features | Corewire Technology, Cobalt chromium stent with Platinum Iridium in core |
| Material | Hydrophilic and biocompatible Biolink polymer, Non cytotoxic drug Zotarolimus |
| Properties | Minimal foreshortening against Proximal optimization |
| Dimension | Strut Thickness of 81microns up to 4mm diameter & 91 microns for 4.5 & 5mm diameter |
The Resolute Onyx stent is indicated for improving coronary luminal diameters in patients, including those with diabetes mellitus, with symptomatic ischemic heart disease due to de novo lesions of length ≤35 mm in native coronary arteries with reference vessel diameters of 2.25 mm to 5.0 mm. The device is found to be safe and effective, with superior acute performance in highly complex high bleeding risk (HBR) patients with 1-month DAPT
View Complete Details
| Type | Drug Eluting Stents |
| Usage/Application | Hospital |
| Brand | Medtronic |
| Model Name/Number | Resolute Integrity |
| Features | Cytostatic limus drug and should remain in the Coronary tissue for at least 180 days |
| Length | Availability in 34 mm & 38 mm size length |
| Properties | CE Mark, DCGI, FDA approval for stent, polymer and delivery system |
| Unique benefit | 1mm and more over expansion of stent platform for vessel optimization. (CE Mark approval) |
The Resolute Integrity stent is indicated for improving coronary luminal diameters in patients, including those with diabetes mellitus, with symptomatic ischemic heart disease due to de novo lesions of length ≤27 mm in native coronary arteries with reference vessel diameters of 2.25 mm to 4.2 mm. Resolute Integrity indication include Left Main, Small Vessel, Transradial Interventions, Overlapping stenting, Direct stenting
View Complete Details
| Procedure Type | Angiographic |
| Tip Shape | Angled |
| Size | Large |
| Application | Hospital |
| Brand | Medtronic |
| Usage/Application | Hospital |
| Material | Polymer |
| Coating | Silicon coating on the inner surface for a more lubricious lumen |
| Packaging Type | Sterile Peel Pouch |
| Is It Customised | Non Customisation |
| Catheters Outer Diameters | 5Fr, 6Fr, 7Fr, 8Fr |
| Features | Full-wall technology, Radiopacity, large lumen |
| Thickness | Large inner lumen( 6F - 0.071 Inch) |
| I Deal In | New Only |
| Disposable | Yes |
Launcher™ coronary guide catheters come with the performance
advantages you expect from a market leader — including a wide variety of curve shapes for trans radial and femoral percutaneous coronary intervention (PCI). Full-Wall technology is a shaft construction process that optimizes the balance between a large lumen and robust performance — offering excellent torque resistance and curve retention. The encapsulated flat wire braid enables thinner, robust walls without compromising support or retention.
Launcher Guide Catheters Offer:
•Flexible distal segment to engage the guide for backup support•Supportive secondary curve for backup support and curve retention
•Workhorse construction for a variety of anatomies and takeoffs
•Larger lumens for excellent contrast flow and enhanced visualization1
•Vest-tech nylon outer jacket for hub-to-tip radiopacity
•Radiopaque marker band to facilitate tip orientation for ostial engagement
•Support for radial and femoral approaches
View Complete Details
| Length | 150 cm |
| Application | Hospital |
| Brand | Medtronic |
| Material | polymer |
| Usage/Application | Hospital |
| Coating | Hydrophilic coating |
| Is It Customised | Non Customisation |
| Disposable | Yes |
| Catheters Outer Diameters | 6Fr, 7Fr |
- The Telescope Guide Extension Catheter is a single-lumen rapid exchange catheter.
- It is designed to act as an extension to a traditional guide catheter and to facilitate the delivery of interventional devices into the vasculature.
- It is intended to be used within the coronary and/or peripheral vasculature to provide support.
View Complete Details
| Size | 6 Fr |
| Size/Dimension | 5Fr, 6Fr |
| Type | Angiographic |
| Application | Hospital |
| Brand | Medtronic |
| Usage/Application | Hospital |
| Is It Customised | Non Customisation |
| Features | Full-wall technology |
| Diameter | 5Fr, 6Fr |
| Disposable | Yes |
A diagnostic catheter as responsive as you are. Time to torque. DxTerity™ diagnostic catheters harness the same Full-Wall technology found in our market-leading guide and aspiration catheters — giving you the responsive torque you need during coronary cases. The diagnostic catheter is indicated for cardiac and vascular procedures. It is designed to deliver radiopaque media, guidewires, and therapeutic agents to selected sites in the vascular system. The different configurations of the diagnostic catheter are designed to be used in arteries from access sites such as the radial, brachial, and femoral arteries.
View Complete Details
| Tip Shape | Atraumatic tip |
| Brand | Medtronic |
| Application | Hospital |
| Material | Nitinol |
| Model Name/Number | Provia |
| Coating | Hydro Track coating |
| Features | Accu-Core Technology with coaxial central core |
| Disposables | Yes |
| Tip Radiopacity | Distal 3mm radiopaque |
| Properties | Distal 1mm hydrophobic in nature |
Crossing Guidewire, Designed to cross your most demanding lesions
Torque control at your fingertips.
ProVia™ coronary guidewires with Accu-Core technology offer the torque and tactile feel, , improved lesion penetration, and a 1-mm non-hydrophilic tip to cross challenging lesions
Available in a wide range of weights and lengths.
View Complete Details
| Brand | Medtronic |
| Shape of Distal Tip | Straight Tip |
| Type | Angiographic |
| Material | Stainless Steel |
| Length | 180 cm, 300 cm |
| Application | Hospital |
| Model Name/Number | Intuition |
| Coating | Hydro Track coating |
| Properties | Available in tip load of 1gm |
| Tip Radiopacity | Distal 3mm radiopaque |
| Disposable | Yes |
| Features | Femoral markers on 90 & 100cm from distal tip |
| Disposables | Yes |
Advanced Workhorse Guidewire
Effective for Challenging Workhorse Cases
Trust your intuition. Intuition™ stainless steel coronary guidewires with Accu-Core technology provide torque and crossability for challenging percutaneous coronary interventions (PCIs).
Torque performance and one-gram tip weight give you precision and confidence during your more difficult workhorse cases
View Complete Details
| Brand | Medtronic |
| Material | Nitinol |
| Type | Angiographic |
| Length | 190 cm, 300 cm |
| Application | Hospital |
| Model Name/Number | Cougar |
| Coating | Proximal Silicon coating with distal Hydrophilic coating for better lubricity |
| Disposable | Yes |
| Features | Nitinol core wire, Double coil tip design |
| Disposables | Yes |
| Unique benefits | Support in tortuous, multivessel treatment |
| Product Description | Cougar(TM) guidewires deliver robust performance & support in challenging coronary cases |
| Properties | Excellent Trackability through Distal and Tortuous Anatomies |
| Distal curve | Straight tip, J tip |
Nitinol Workhorse Guidewire
Excellent Trackability through Distal and Tortuous Anatomies
Support in tortuous, multivessel treatment.
Cougar™ nitinol workhorse guidewires deliver robust performance and support for your challenging coronary cases, and feature:
•Nitinol core wire•Double coil tip design
View Complete Details
| Size | 6 F |
| Guide Catheter Compatibility | 6Fr compatible |
| Brand | Medtronic |
| Length | 140 cm |
| Application | Hospital |
| Type | Aspiration Catheter |
| Packaging Type | Provided with a kit of 2 aspiration syringes, Extension tubing with stop cock and filter baskets |
| Usage/Application | Hospital |
The Export Advance™ aspiration catheter delivers consistent, high-performing aspiration power when it matters most — restoring flow and protecting patients.
The Export™ aspiration catheter is indicated for:
1. Removal/aspiration of embolic material (thrombus/debris) from vessels of the arterial system
2. To subselectively infuse/deliver diagnostic or therapeutic agents with or without vessel occlusion.
Superior Deliverability1
- Full-Wall Technology provides variable levels of stiffness without joints, for optimal kink resistance and catheter performance.
Dependable Delivery to the Target Site
- Preloaded stylet enhances shaft stiffness during catheter delivery, boosting kink resistance, trackability, and pushability2
- Buddy wire compatibility allows for extra support, when needed.
- Large extraction lumen (0.044" proximal; 0.043" distal) increases aspiration power
- Optimized hub geometry improves flow
- Soft, short, forward-facing tip design permits excellent particle capture
View Complete Details
Explore more categories
- Developed and Managed by IndiaMART InterMESH Limited