Fire Alarm System
Offering you a complete choice of products which include 2 Zone Ravel Conventional Panel, Fire Alarm Hooter, Ravel Single Loop Moniti Fire Alarm Addressable Panel, Heat Detector Fire Alarm System and Manual Call Point (MCP).

Interested in this product?
Get Best Quote
Backup Battery | Yes |
Usage/Application | Fire Alarm |
Body Material | M S Body |
Circuit Type | Charging Voltage - Charging Current |
Country of Origin | Made in India |
Battery Type | 24VDC (2 Nos of 12V, 7Ah Sealed Lead acid battery). |
Alarm Volume | Any |
Brand | Ravel |
AC Input Power | 120 / 220VAC + 10% -15%, 60 / 50 Hz. 60W |
Relay Outputs | Alarm Relay |
Automation Grade | Automatic |
Model Name/Number | RE-102 |
Display Type | 6 X 2 Dot Matrix LCD Display. |
Type | Conventional |
Control Keys | Mute Buzzer, System Reset, Evacuate |
System Components | Fire Alarm Control Panel |
Standby Current | 24VDC (2 Nos of 12V, 7Ah Sealed Lead acid battery) |
Color | Red/ white |
Ravel 2 Zone Conventinal Fire Alarm Panel
- Ravel Indian Manufacturer, International standard.
- Switch Mode Power Supply.
- Modular Construction, Serviceable.
- Surface Mount Technology.
- Battery polarity & deep discharge protection.
- As per IS -15908: 2011 Standard.
- 16 X 2 Dot Matrix LCD Display.
- Standby battery backup with built in charging.
- Fire / Fault status in unambiguous colored LED indication.
- Switch Mode Power Supply.
- Tactile Keypad for easy panel operation.
- System on indication.
- Main, Standby status indication.
- Low Battery visual warning with audible tone.
- Relay output for actuators for Fire and Fault.
- Lamp Test facility
- Zone wise one man walk Test Facility.
- Zone wise Isolation facility with loop voltage cut off.
- Compatible to all type of Conventional Detectors.
- Optional Zone Wise Sounder / Zone Wise Contact.
View Complete Details
Yes, I am interested!

Interested in this product?
Get Best Quote
Power Source | DC/Battery |
Flash Rate | 1.5S |
Material | Plastic |
Size | Any |
Color | Red |
Voltage | 12 |
Mounting Type | Wall |
Model Name/Number | AGNI-405 |
Usage/Application | Offices |
- Material: Plastic Stainless Steel, color: red
- Strobe / Hooter with Flasher for Conventional Fire Alarm System comes with flashing LED light,
- Package contents: 1 of 24v, hooter/Voltage Range: DC 24V
- High Sound output / Light Source
- The siren will send out both loud sound and quick flash light to remind people escape from the fire.
View Complete Details
Yes, I am interested!

Interested in this product?
Get Best Quote
Ravel Single Loop Moniti Fire Alarm Addressable Panel
Rs 4,600 / PieceGet Latest Price
Product Brochure Watch Video
Relative Humidity | 93 +- 2% RH (non-condensing) at 32 +-2 Degree C/90 +-3 Degree F. |
Warranty | 1 Year |
I Deal In | New Only |
AC Input Power | 120 / 220VAC + 10% -15%, 60 / 50 Hz |
Brand | RAVEL |
Usage/Application | Office |
Model Name/Number | MonitI-x |
Control Keys | System Reset, Evacuate, Mute Buzzer |
System Components | Fire Alarm Control Panel |
Relay Outputs | Alarm Relay |
Condition | New |
Zones | 2 Zone |
Type | Automatic |
Automation Grade | Semi-Automatic |
Operating Voltage | 24VDC |
Operating Temperature | 0 - 49 Degree C/32-120 Degree F. |
Dimensions | L 390mm X H 295mm X D110mm |
Operating Current | 1.0 A |
-
CE approved – Single Loop Analogue addressable fire alarm panel with 127 devices of any combination with 20 loop powered sounders in addition .supports single repeater panel,Touch key panel with USB inbuilt for Laptop connectivity. Front Panel programmable.
View Complete Details
Yes, I am interested!

Interested in this product?
Get Best Quote
Automation Grade | Semi-Automatic |
Body Material | Copper |
Contact Rating | 59 C (138 F) |
Weight (grams) | 130g with base |
Color | White |
Wireless Frequency | no |
Operating Temperature | -10 DegreeC to 50 DegreeC |
Operating Voltage (VDC) | 9 ~ 33V DC. |
System Components | Fire Alarm Control Panel |
Startup Time (sec) | 5 sec |
Control Keys | Mute Buzzer, System Reset, Evacuate |
Relay Outputs | Alarm Relay |
Type | Conventional |
Model Name/Number | RE 316H - 2L |
Alarm Current (mA) | 90 mA (Max). |
Put simply, a heat detector - or heat alarm - is a device that's used to detect any substantial increase in temperature which may indicate a fire is about to break out.
Operating Voltage | : | 9 ~ 33V DC |
Reset Voltage | : | less than 1V |
Start-Up Current | : | 120 μA. |
Alarm Current | : | 40 mA (Max) |
Remote Output | : | 15mA maximum open collector |
Thermal Rating | : | 59 °C (138 °F) |
Rate of Raise of Temp | : | 11.1°C / min (20°F/min) |
Operating Temperature | : | -10 °C to 37.8 °C |
Humidity | : | 0 – 95% RH, non-condensing |
View Complete Details
Yes, I am interested!

Interested in this product?
Get Best Quote
Usage/Application | Fire Alarm System |
Model Name/Number | AGNI-301 |
Box Material | 16/20 SWG MS CRCA Sheet, Powder Coated |
Color | Signal Red |
Glass | 30 sq. cm |
Relay Outputs | Trouble Relay |
Control Keys | Evacuate |
Brand | Agni |
Conventional manual call point is an emergency alerting device which can be activated by pressing a transparent plastic window on its front side. The call point once activated can be reset by using a key with the device. Designed for use with conventional fire alarm control panels and alarm loop by installing the module conventional zone module. This allows the fire alarm control panel to monitor the conventional call point devices.