Weight Indicators
Laumas W100 Weight Indicator (Made In Italy)
₹ 27,000/PieceGet Latest Price
Minimum Order Quantity: 1 Piece
Product Brochure Watch Video
| Model Name/Number | Laumas W100 |
| Brand | Laumas |
| Power supply and consumption | (VDC) 12/24 VDC +-10%; 5 W |
| No Of Load Cells In Parallel and Supply | max 8 (350 ohm); 5 VDC / 120 mA |
| Linerity / Analog Output Linearity | < 0.01% F.S.; < 0.01% F.S. |
| Thermal Drift / Analog Output Thermal Drift | < 0.0005% F.S./ Degree C; < 0.003% F.S./Degree C |
| A/D Converter | 24 bit (16000000 points) |
| Max Divisions | +-999999 |
| Measurement Range | +-39 mV |
| Max Sensitivity Of Usable Load Cells | +-7 mV/V |
| Max Conversions Per Second | 300 conversions/second |
| Display range | +-999999 |
| No. Of Decimals / Display Increments | 0/4 / x 1 x 2 x 5 x 10 x 20 x 50 x 100 |
| Digital Filter / Readings Per Second | 10 levels / 5/300 Hz |
| Relay Outputs | N. 5 - max 115 VAC; 150 mA |
| Digital Inputs | N. 3 - optoisolated 5 - 24 VDC PNP |
| Serial Ports | RS485, RS232 |
| Baud Rate | 2400, 4800, 9600, 19200, 38400, 115200 |
| Humidity (non condensing) | 85% |
| Storage Temperature | -30 Degree C +80 Degree C |
| Working Temperature | -20 Degree C +60 Degree C |
| Optoisolated Analog Output | 0/20 mA; 4/20 mA (max 300 ohm); 0/10 V; 0/5 V; +-10 V; +-5 V (min 10 kohm) |
| Relay Outputs | N. 5 - max 30 VAC, 60 VDC; 150 mA |
Load cell resistance measurement (use a digital multimeter):
- Disconnect the load cells from the instrument and check that there is no moisture in the cell junction box caused by condensation or water infiltration. If so, drain the system or replace it if necessary.
- The value between the positive signal wire and the negative signal wire must be equal or similar to the one indicated in the load cell data sheet (output resistance).
- The value between the positive excitation wire and the negative excitation wire must be equal or similar to the one indicated in the load cell data sheet (input resistance).
- The insulation value between the shield and any other cell wire and between any other cell wire and the body of the load cell must be higher than 20 Mohm.
Load cell voltage measurement (use a digital multimeter):
- Take out the load cell to be tested from underneath the container, or alternatively, lift the container support.
- Make sure that the excitation of two wires of the load cell connected to the instrument (or amplifier) is 5 VDC ±3%.
- Measure the response signal between the positive and the negative signal wires by directly connecting them to the tester, and make sure that it is comprised between 0 and 0.5 mV.
- Apply load to the cell and make sure that there is a signal increment.
Additional Information:
- Item Code: 84239090
- Production Capacity: 50
- Delivery Time: 1 Day
View Complete Details
W200 Weight Indicator Laumas (Made In Italy)
₹ 27,000/PieceGet Latest Price
Minimum Order Quantity: 1 Piece
Product Brochure Watch Video
| Model Name/Number | W200 |
| Brand | Lamumas |
| Power supply and consumption | 12/24 VDC +-10%; 5 W(on request: 115/230 VAC; 50/60 Hz; 6 VA) |
| Number of load cells - Load cells supply | Up to 8 (350 Ohm) - 4/6 wires 5 VDC/120 mA |
| Linearity- Analog output linearity | <0.01% full scale-<0.01% full scale |
| Thermal drift - Analog output thermal drift | <0.0005% full scale/ Degree C - <0.003% full scale/Degree C |
| A/D Converter | 24 bit (16000000 points) - 4.8 kHz |
| Divisions (with measurement range +-10 mV and sensitivity 2 mV/V) | +-999999 - 0.01 uV/d |
| Measurement Range | +-39 mV |
| Usable load cells sensitivity | +-7 mV/V |
| Conversions per second | 300/s |
| Display range | +-999999 |
| Decimals - Display increments | 0/4 - x1 x2 x5 x10 x20 x50 x100 |
| Digital filter - Readings per second | 10 levels - 5/300 Hz |
| Relay outputs | 5/4 - max 115 VAC/150 mA |
| Optoisolated digital inputs | 3/2 - 5/24 VDC PNP |
| Serial ports | RS485, RS232 |
| Baud Rate | 2400, 4800, 9600, 19200, 38400, 115200 (bit/s) |
| Optoisolated analog output (option on request) | 16 bit = 65535 divisions. 0/20 mA; 4/20 mA (up to 300Ohm)0/10 V; 0/+-5 V; +-10 V; 5 V (min 10 kOhm) |
| Humidity (condensate free) | 85% |
| Storage Temperature | -30 Degree C +80 Degree C |
| Working Temperature | -20 Degree C +60 Degree C |
| Relay outputs | 5/4 - max 30 VAC, 60 VDC/150 mA |
| Working temperature | -20 Degree C +50 Degree C |
- Weight indicator in DIN box suitable for front panel mounting.
- Dimensions: 96x130x96 mm (drilling template: 92x92 mm).
- 6-digit semi-alphanumeric red LED display (14 mm height).
- 8 signalling LED.
- 5-key keyboard.
- IP54 front panel protection rating (IP65 front optional).
- Real-time clock/calendar with buffer battery.
- Extractable screw terminal blocks.
Additional Information:
- Production Capacity: 50
- Delivery Time: 1 Week
View Complete Details
Laumas ATEX Stainless Steel Weight Indicator
₹ 16,000/PieceGet Latest Price
Product Brochure Watch Video
| Model Name/Number | WINOX-L/R |
| Brand | Laumas |
| Linearity - Analog output linearity | <0.01% full scale - <0.01% full scale |
| Thermal drift - Analog output thermal drift | <0.0005% full scale/Degree C - <0.003% full scale/Degree C |
| A/D Converter | 24 bit (16000000 points) - 4.8 kHz |
| Divisions (with measurement range +-10 mV and sensitivity 2 mV/V) | +-999999 - 0.01 uV/d |
| Measurement Range | +-39 mV |
| Usable load cells sensitivity | +-7 mV/V |
| Conversions per second | 300/s |
| Display range | +-999999 |
| Decimals - Display increments | 0/4 - x1 x2 x5 x10 x20 x50 x100 |
| Digital filter - Readings per second | 10 levels - 5/300 Hz |
| Relay outputs | 5/4 - max 115 VAC/150 mA |
| Optoisolated digital inputs | 3/2 - 5/24 VDC PNP |
| Serial ports | RS485, RS232 |
| Baud rate | 2400, 4800, 9600, 19200, 38400, 115200 (bit/s) |
| Optoisolated analog output (option on request) | 16 bit = 65535 divisions. 0/20 mA; 4/20 mA (up to 300Ohm),0/10 V; 0/5 V; +-10 V; +-5 V (min 10 kOhm) |
| Humidity (condensate free) | 85% |
| Storage Temperature | -30 Degree C +80 Degree C |
| Power supply and consumption | 12/24 VDC +-10%; 6 W(on request P version: 115/230 VAC; 50/60 Hz; 6 VA) |
| Number of load cells - Load cells supply | up to 8 (350 Ohm) - 4/6 wires - 5 VDC/120 mA |
| Working temperature | -20 Degree C +60 Degree C |
| Applied standards | 2014/31/UE - EN45501:2015 - OIML R76:2006 |
| Operation modes | Single interval, multi-interval, multiple range |
| Accuracy class | III or IIII |
| Maximum number of scale verification divisions | 10000 (class III); 1000 (class IIII) |
| Minimum input signal for scale verification division | 0.2 uV/VSI |
Descriptions:
- AISI 304 stainless steel weight indicator.
- L version: 6-digit semi-alphanumeric backlit LCD display (20 mm height) - 46 signalling symbols.
- R version: 6-digit semi-alphanumeric red LED display (20 mm height) - 16 signaling LED.
- 6-key keyboard.
- Real-time clock/calendar with buffer battery.
Base Program:
- Piece counting.
- Weight totalizing.
- Hysteresis and setpoint value setting.
- The indicator can be used as a remote display with setpoints.
- 12 groups selection by 5 setpoint via external selector switch or contact (option on request).
Barching Program:
- 99 settable formulas.
- Batching resume after a blackout.
- Automatic fall calculation.
- Tolerance error control.
- Precision batching through slow function.
- Precision batching through tapping function.
- Consumption storage.
- Printing of batching data.
- Alarm contact management.
- Selection of the first 12 formulas via external selector switch or contact (option on request).
- Batching start via external contact or keyboard.
Input/Output and Communications
- RS485/RS232 serial ports for communication via protocols ModBus RTU, ASCII Laumas bidirectional or continuous one way transmission.
- 5 relay outputs controlled by the setpoint values or via protocols(4 outputs if analog output is present).
- 3 optoisolated PNP digital inputs: status reading via serial communication protocols (2 inputs if analog output is present).
- 1 load cell dedicated input.
- Current or voltage 16 bit optoisolated analog output (option on request).
- WiFi module (option on request).
Main Functions:
- Connections to:
- PLC via analog output (on request);
- PC/PLC via RS485/RS232 (up to 99 instruments with line repeaters, up to 32 without line repeaters);
- Remote display and printer via RS485/RS232;
- Up to 8 load cells in parallel by junction box;
- Intelligent junction box or other multichannel instruments: allow the use of advanced functions as digital equalization, load distribution analysis and automatic diagnostics.
- Digital filter to reduce the effects of weight oscillation.
- Theoretical calibration (via keyboard) and real calibration (with sample weights and the possibility of weight linearization up to 8 points).
- Tare weight zero setting.
- Automatic zero setting at power-on.
- Gross weight zero tracking.
- Semi-automatic tare (net/gross weight) and preset tare.
- Semi-automatic zero.
- Displaying of the maximum weight value reached (peak).
- Direct connection between RS485 and RS232 without converter.
- Weight value printing with date and time via keyboard or external contact.
Additional Information:
- Production Capacity: 50
- Delivery Time: 1 WEEK
- Packaging Details: AS PER COMPANY STANDARD
View Complete Details
- Developed and Managed by IndiaMART InterMESH Limited