Have a requirement?
Chat with us
Have a requirement?
Chat with us
- Digital PH Meter
- Microprocessor pH Meter Insif
- Digital pH meter with Automatic Temp. Compensation
- Digital Conductivity Meter
- Digital Conductivity With Automatic Temp. Compensation
- TDS Meter Digital
- Dissolved Oxygen Meter / D.o Meter
- Digital Turbidity Meter
- Digital Salinity Meters
- Microprocesser Based Colorimeter with Auto Zero
- Microprocessor Colony Counter
- Digital Colony Counter
- Water & Soil Testing Kit 6 Parameters, 7 Parameters, Deluxe
- Digital Colorimeter
- Meter Reset to Factory Calibration
- Microprocessor Dissolved Oxygen Meter (IE-708)
- Digital Polarimeter (IE-716)
- Digital Potentiometer 2-Probe (IE-717)
- Digital Potentiometer 42-Probe (IE-718)
- Microprocessor Hemoglobin Meter (IE-719)
- Digital Hemoglobin Meter (IE-720)
- Digital Soil Moisture Meter (IE-721)
- Digital Melting Point Apparatus (IE-751)
- Digital Automatic Melting Point Apparatus (IE-752)
- Leak Test Apparatus (ie-753)
- Digital Flame Photometer (IE-754)
- Digital Friability Test Apparatus (IE-755)
- Digital Nephelometer
Analytical Lab
Digital PH Meter
Get Latest Price
View Complete Details
Microprocessor pH Meter Insif
Get Latest Price
The meters digital filter improves measurement speed and accuracy.
The meter offers a back light LCD display and is dust-proof and is very Portable.
This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service.
Supplied Equipment List
• Microprocessor pH Meter
• pH Electrode
• ATC (Automatic Temperature Compensation) Electrode
• Standard buffer solutions (4.00pH, 7.00pH) / 100ml
• Stand and Probe Holder
• Users Guide
View Complete Details
Digital pH meter with Automatic Temp. Compensation
Get Latest Price
View Complete Details
Digital Conductivity Meter
Get Latest Price
The Digital Conductivity Meter contains a built-in oscillator, amplifier and display. The A.C. Voltage are applied to solutions which are to be tested for Conductivity. This is done by Conductivity Cell, which consists of 2 platinum plates separated by desired distance. The liquid between the platinum plates acts as a conductor. The Conductivity of that liquid is displayed on the screen. The temperature of solution should also be noted.
Technical Specifications
• Model: Digital Table Model
• Display: 3 -1/2 Digit LED
• Range: 0-200, 0-2,0-20,0-200 & 0- 1000m Omhs/cm
• Temperature Compensation Manual: 0-50oC (Automatic- facility)
• Cell Constant: Adjustment Adjustable
• Conductivity Cell: Platinum DIP Type
• RESOLUTION : 0.1 Mohs/cm
• Accuracy: +1% FS +1 Digit
• Power: 230v + 10% ac, 50 Hz
• Dimensions: 275 x 175 x 76 mm
• Weight 2 kg. (Approx.)
• Accessories Conductivity Cell, Operation Manual
View Complete Details
Digital Conductivity With Automatic Temp. Compensation
Get Latest Price
The Digital Conductivity Meter contains a built-in oscillator, amplifier and display. The A.C. Voltage are applied to solutions which are to be tested for Conductivity. This is done by Conductivity Cell, which consists of 2 platinum plates separated by desired distance. The liquid between the platinum plates acts as a conductor. The Conductivity of that liquid is displayed on the screen. The temperature of solution should also be noted.
Technical Specifications
• Model: Digital Table Model
• Display: 3 -1/2 Digit LED
• Range: 0-200, 0-2,0-20,0-200 & 0- 1000m Omhs/cm
• Temperature Compensation Manual: 0-50oC /Automatic
• Cell Constant: Adjustment Adjustable
• Conductivity Cell: Platinum DIP Type
• RESOLUTION : 0.1 Mohs/cm
• Accuracy: +1% FS +1 Digit
• Power: 230v + 10% ac, 50 Hz
• Dimensions: 275 x 175 x 76 mm
• Weight 2 kg. (Approx.)
• Accessories Conductivity Cell, Operation Manual
View Complete Details
TDS Meter Digital
Get Latest Price
Display 3 ½ Digit LED Display
Accuracy ± 2% S ± 1 digit
Resolution 0.1 ppm
Temp. Compensation 0° to 50° C manual
Cell Constant Adjustable on display
View Complete Details
Dissolved Oxygen Meter / D.o Meter
Get Latest Price
- D.O probe consist of a Silver and Gold electrode cells, an electrolyte tube with the ring .
- Display 3 ½ digit LED
- Range 0-20 Ppm
- Accuracy ± 0.2 ppm
- Resolution ± 0.1 ppm
- Calibration Manual
- Temp. 0-50° C
- Power 220/230 VAC
View Complete Details
Digital Turbidity Meter
Get Latest Price
Range 0 to 200 NTU 0 to 1000 NTU2 Ranges
Resolution 1 NTU
Accuracy ± 3 % S ± 1 digit
Sample System 30 mm clear glass tube
Light Source 6.8 V, Tungsten Lamp
Detector Photo diode
Display 3½ digit LED display
Power 230 VAC ± 10% 50 Hz AC
Size (LxBxH) 305 x 305 x 165 mm
Weight 4 kg. (Approx)
Accessories Test Tubes, Dust Cover & Inst. Manual
View Complete Details
Digital Salinity Meters
Get Latest Price
Digital Salinity Meters are reliable and accurate test instruments for measurement of Salinity of aqueous solutions. They measure salinity in three ranges. The cell constant is flashed on a digital display & can be adjusted from the front panel. The instruments have the “Check” facility to calibrate the instrument.
Display 3 -1/2 Digit LED
Range 2 ppt, 20 ppt, 50 ppt
Temperature Compensation Manual0-50’C (Automatic-facility)
Cell Constant Adjustment Adjustable
Conductivity Cell Platinum DIP Type
RESOLUTION 0.1 ppt
Accuracy +1% FS +1 Digit
Power 230v + 10% ac, 50 Hz
Weight 2 kg. (Approx.)
Accessories Conductivity Cell
Operation Manual
View Complete Details
Microprocesser Based Colorimeter with Auto Zero
Get Latest Price
The basic set-up of the colorimeter is:
- A. LED light source: Produces polychromatic light over the entire visible region.
- B. Broad spectrum filter: The color wheel has eight different filters. The filter employed is selected by wavelength. Each filter will produce monochromatic light at a specified peak wavelength with a bandpass of 20 nm. The filters enable the user to perform tests from 400 to 680 nm.
- C. Cuvette Holder: It holds the inserted cuvette during testing. It is imperative the cuvette be consistently oriented in the holder. Round cells usually have orientation markings to correctly position the cuvette.
- D. Detector: A silicon photo diode is used as the detector. The photo detector current will change as a function of light energy.
- E.Display:The current signal from the detector is converted to a numerical value, absorbance and is shown on led display.
MODEL Digital
- DISPLAY 3 - Digit LED DISPLAY
- WAVELENGTH RANGE 400nm, 420nm, 480nm, 520nm, 540nm, 580nm, 620nm, 680nm
- TRANSMISSION N/A
- ABSORBANCE 0 - 1.99 abs
- FILTERS Best Quality Glass Filters
- BANDWIDTH 15 - 20 nm
- REPEATABILITY 0.01 abs
- ACCURACY - 0.01 TO + 0.01 ABS
- SAMPLE HOLDER Cuvette Round 9mm
- DIMENSIONS (L x B x H) Instrument : 225 x 250 x 280 mm (Approx.)
- WEIGHT 2 Kg
- POWER 230 V±10% AC, 50 Hz
- STANDARD ACCESSORIES Cuvette , Instruction Manual
View Complete Details
Microprocessor Colony Counter
Get Latest Price
DISPLAY 6 Digit Digital LCD Display
MAX COUNTS 9999
KEYBOARD Soft Touch
CORRECTION Membrane Keys Correction count facility
STORAGE 99 Result
DISH SIZE
MAGNIFICATION 1.7 surface magnification
DIMENSIONS (L x B x H) 225x250x280 mm Approx
WEIGHT
POWER 230 V +10% AC, 50 Hz
STANDARD ACCESSORIESC Marking Pen, Magnifying Lens, Lens Holder, Instruction Manual
View Complete Details
Digital Colony Counter
Get Latest Price
DISPLAY 4 Digit Digital LCD Display
MAX COUNTS 9999
KEYBOARD Soft Touch
CORRECTION membrane keys Correction count facility available to cancel the unwanted
STORAGE count storage retained even if the system is switched off
MAGNIFICATION 1.7 surface magnification
DIMENSIONS (L x B x H) 225x250x280 mm Approx
WEIGHT
POWER 230 V +10% AC, 50 Hz
STANDARD ACCESSORIESC Marking Pen, Magnifying Lens, Lens Holder, Instruction Manual
View Complete Details
Water & Soil Testing Kit 6 Parameters, 7 Parameters, Deluxe
Get Latest Price
View Complete Details
Digital Colorimeter
Get Latest Price
The basic set-up of the colorimeter is:
A. LED light source: Produces polychromatic light over the entire visible region.
B. Broad spectrum filter: The colorwheel has eight different filters. The filter employed is selected by wavelength. Each filter will produce monochromatic light at a specified peak wavelength with a bandpass of 20 nm. The filters enable the user to perform tests from 400 to 680 nm.
C. Cuvette Holder: It holds the inserted cuvette during testing. It is imperative the cuvette be consistently oriented in the holder. Round cells usually have orientation markings to correctly position the cuvette.
D. Detector: A silicon photo diode is used as the detector. The photo detector current will change as a function of light energy.
E.Display:Thecurrentsignalfromthedetectorisconvertedtoanumericalvalue, absorbance and is shown on led display.
MODEL Digital
DISPLAY 3 - Digit LED DISPLAY
WAVELENGTH RANGE 400nm, 420nm, 480nm, 520nm, 540nm, 580nm, 620nm, 680nm
TRANSMISSION N/A
ABSORBANCE 0 - 1.99 abs
FILTERS Best Quality Glass Filters
BANDWIDTH 15 - 20 nm
REPEATABILITY 0.01 abs
ACCURACY - 0.01 TO + 0.01 ABS
SAMPLE HOLDER Cuvette Round 9mm
DIMENSIONS (L x B x H) Instrument : 225 x 250 x 280 mm (Approx.)
WEIGHT 2 Kg
POWER 230 V±10% AC, 50 Hz
STANDARD ACCESSORIES Cuvette , Instruction Manual
View Complete Details
Meter Reset to Factory Calibration
Get Latest Price
View Complete Details
need