X

Instruments Zone

Sukhlia, Indore, Madhya Pradesh

| GST  23AQGPM5598R1ZW

is a member of IndiaMART

| Verified Supplier

|

View Mobile Number 74% Response Rate
Send Email

Our Products

+View All

Transducer Converter Sensor

Manufacturer of a wide range of products which include Sense Air eSENSE Series Carbon Dioxide Transmitter/ CO2 Tx, Meco-g R-wt11 Active Power Transducer, Powerline Transducer, Meco-g R-wt33 Powerline Transducer Active Power Transducer, Meco-g R-wt34 Powerline Active Transducer - (3 Phase 3 Elem), Meco-g R-rpt11, Reactive Power Transducer - Powerline Transducer and Meco-g R-rpt33 Reactive Power Transducer - Powerline Transduce.

Sense Air eSENSE Series Carbon Dioxide Transmitter/ CO2 Tx
Interested in this product?
Get Best Quote
Display TypeDigital, Without
Model Name/Numbere-Sense
Measurement Range0-10000PPM

Sense Air eSENSE Series Carbon Dioxide Transmitter/ CO2 Tx

 

 

FEATURES

SenseAir´s patented state-of-the-art goldplated

infrared (NDIR) waveguide technology

offers reliable measurements

· Measurement range: 0 - 2 000 ppm CO

2

· Two analogue outputs (not model –I):

· Internal automatic self-diagnostics.

· Maintenance-free in normal applications

· Cost-optimized for connection to DDC:s

· Prepared for complementary passive

temperature element (model -Tr).

· Different housing options

General Performance

Compliance with ............................................... EMC directive 89/336/EEC. RoHS directive 2002/95/EG

Operating Temperature Range ....................... 0 – 50 °C

Storage Temperature Range ........................... -40 to +70 °C (display model -D: -20 to +70 °C )

Operating Humidity Range ............................... 0 to 95% RH (non-condensing)

Operating Environment .................................... residential, commercial and industrial spaces 1

Warm-up Time ................................................. £ 1 min. (@ full specs £ 15 minutes)

Sensor Life Expectancy ................................... > 15 years

Maintenance Interval ........................................ no maintenance required 2

Self Diagnostics ............................................... complete function-check, LCD error indication (display model -D)

Display (model -D) ............................................ 4 Digits, 7 segments LCD with ppm indicator

Electrical

Power Input ...................................................... 24 VAC/VDC ±20%, 50 Hz (half-wave rectifier input)

Power Consumption ......................................... < 1 Watt average

Connection screw terminal A ........................... 4 x 1,5 mm2 for power input (G+, G0) and voltage outputs (OUT1, OUT2)

Connection screw terminal B ........................... 2 x 1,5 mm2 for passive resistive output (Y, M) for option –Tr

Model IP50 ........................................................ 34 cm 3-wire pigtail. Please note that OUT2 is not made available.

CO2 Measurement

Sensing method ............................................... Gold-plated infrared (NDIR) waveguide technology with Automatic Background

Calibration (ABC) and passive gas diffusion (no moving parts)

Response Time (T ) ........................................ < 10 sec. @ 30 cc/min. flow rate , < 3 min. diffusion time

Repeatability ..................................................... ± 20 ppm ± 1 % of reading

Accuracy 2 ........................................................ ± 30 ppm ± 3 % of reading

Annual Zero Drift 2 ............................................ < ± 10 ppm

Pressure Dependence ..................................... + 1.6 % reading per kPa

Measurement range .......................................... 0 - 3 000 ppm

Extended range……………………………….….3001-9999ppm

 

Outputs

Output signal terminal CO2 3

OUT1 linear conversion range .......................... 0 – 10 VDC for 0 – 2 000 ppm.

OUT2 linear conversion range .......................... 2 – 10 VDC, or 4 - 20 mA for 0 - 2 000 ppm.

D/A conversion accuracy .................................. ± 2 % of reading ± 50 mV

Electrical characteristics.................................... R < 100 Ohm, R > 5 kOhm

View Complete Details

Yes, I am interested!

Meco-g R-wt11 Active Power Transducer, Powerline Transducer
Interested in this product?
Get Best Quote

Meco-g R-wt11 Active Power Transducer, Powerline Transducer

Rs 2,520 / Piece(s)Get Latest Price

Minimum Order Quantity: 1 Piece(s)

MECO-G" WATT Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.

GENERAL SPECIFICATION

Accuracy

± 0.5% of Rated output, ± 0.2 % (Optional)

Output Ripple

0.2% RMS

Response

Less than 0.5 Sec.

Frequency

50 / 60 Hz.

Zero Adj.

± 2% Min

Span Adi.

±10 % Min.

Operating Temp.

0° ~ 50° C (RH < 90 %) Non - Condensing

Storage Temp

-20°C ~ 70°C

Overload Continuous

2 x Rated Current, 1.2 x Rated Voltage

Breakdown Impulse Voltage

4.5KV , 1 x 40µs (without dewing.)

Tempreature Coefficient

0.03% / °C.

Dielectric Withstand Voltage 
between Input / Output / Power / Case

2 KV AC for 1 minute.

Insulation Resistance (@ 500V DC)

>100MΩ

 

TYPE

MODEL

INPUT RANGES

DIMENSION

SINGLE PHASE

R-WT 11

0-63.5,100,110,415,440 V (ANY ONE)
0-1,2,2.5,5A (ANY ONE)

Size 2

3 PHASE-3 WIRE

R-WT 33

Size 3

3 PHASE-4 WIRE

R-WT 34

Size 3

 

DC OUTPUT RANGES

0-1V

≥ 1KΩ

0-5V

≥ 5KΩ

1-5V

≥ 5KΩ

0-10V

≥ 10KΩ

2-10V

≥ 10KΩ

0-1mA

≤ 10KΩ

0-5mA

≤ 2KΩ

0-10mA

≤ 1KΩ

4-20mA / 4-12-20mA

≤ 500Ω

 

AUXILLIARY POWER SUPPLY

0-110 VAC ± 10% 50/60 Hz 2VA Approx.

0-220 VAC ± 10% 50/60 Hz 2VA Approx.

0-24 VDC ± 10% 2Watts Approx.

0-48 VDC ± 10% 2Watts Approx.

0-110 VDC ± 10% 2Watts Approx.

0-220 VDC ± 10% 2Watts Approx.

 

View Complete Details

Yes, I am interested!

Meco-g R-wt33 Powerline Transducer Active Power Transducer
Interested in this product?
Get Best Quote

Meco-g R-wt33 Powerline Transducer Active Power Transducer

Rs 3,600 / Piece(s)Get Latest Price

Minimum Order Quantity: 1 Piece(s)

MECO-G" WATT Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.

GENERAL SPECIFICATION

Accuracy

± 0.5% of Rated output, ± 0.2 % (Optional)

Output Ripple

0.2% RMS

Response

Less than 0.5 Sec.

Frequency

50 / 60 Hz.

Zero Adj.

± 2% Min

Span Adi.

±10 % Min.

Operating Temp.

0° ~ 50° C (RH < 90 %) Non - Condensing

Storage Temp

-20°C ~ 70°C

Overload Continuous

2 x Rated Current, 1.2 x Rated Voltage

Breakdown Impulse Voltage

4.5KV , 1 x 40µs (without dewing.)

Tempreature Coefficient

0.03% / °C.

Dielectric Withstand Voltage 
between Input / Output / Power / Case

2 KV AC for 1 minute.

Insulation Resistance (@ 500V DC)

>100MΩ

 

TYPE

MODEL

INPUT RANGES

DIMENSION

SINGLE PHASE

R-WT 11

0-63.5,100,110,415,440 V (ANY ONE)
0-1,2,2.5,5A (ANY ONE)

Size 2

3 PHASE-3 WIRE

R-WT 33

Size 3

3 PHASE-4 WIRE

R-WT 34

Size 3

 

DC OUTPUT RANGES

0-1V

≥ 1KΩ

0-5V

≥ 5KΩ

1-5V

≥ 5KΩ

0-10V

≥ 10KΩ

2-10V

≥ 10KΩ

0-1mA

≤ 10KΩ

0-5mA

≤ 2KΩ

0-10mA

≤ 1KΩ

4-20mA / 4-12-20mA

≤ 500Ω

 

AUXILLIARY POWER SUPPLY

0-110 VAC ± 10% 50/60 Hz 2VA Approx.

0-220 VAC ± 10% 50/60 Hz 2VA Approx.

0-24 VDC ± 10% 2Watts Approx.

0-48 VDC ± 10% 2Watts Approx.

0-110 VDC ± 10% 2Watts Approx.

0-220 VDC ± 10% 2Watts Approx.

 

View Complete Details

Yes, I am interested!

Meco-g R-wt34 Powerline Active Transducer - (3 Phase 3 Elem)
Interested in this product?
Get Best Quote

Meco-g R-wt34 Powerline Active Transducer - (3 Phase 3 Elem)

Rs 3,780 / Piece(s)Get Latest Price

Minimum Order Quantity: 1 Piece(s)

MECO-G" WATT Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.

GENERAL SPECIFICATION

Accuracy

± 0.5% of Rated output, ± 0.2 % (Optional)

Output Ripple

0.2% RMS

Response

Less than 0.5 Sec.

Frequency

50 / 60 Hz.

Zero Adj.

± 2% Min

Span Adi.

±10 % Min.

Operating Temp.

0° ~ 50° C (RH < 90 %) Non - Condensing

Storage Temp

-20°C ~ 70°C

Overload Continuous

2 x Rated Current, 1.2 x Rated Voltage

Breakdown Impulse Voltage

4.5KV , 1 x 40µs (without dewing.)

Tempreature Coefficient

0.03% / °C.

Dielectric Withstand Voltage 
between Input / Output / Power / Case

2 KV AC for 1 minute.

Insulation Resistance (@ 500V DC)

>100MΩ

 

TYPE

MODEL

INPUT RANGES

DIMENSION

SINGLE PHASE

R-WT 11

0-63.5,100,110,415,440 V (ANY ONE)
0-1,2,2.5,5A (ANY ONE)

Size 2

3 PHASE-3 WIRE

R-WT 33

Size 3

3 PHASE-4 WIRE

R-WT 34

Size 3

 

DC OUTPUT RANGES

0-1V

≥ 1KΩ

0-5V

≥ 5KΩ

1-5V

≥ 5KΩ

0-10V

≥ 10KΩ

2-10V

≥ 10KΩ

0-1mA

≤ 10KΩ

0-5mA

≤ 2KΩ

0-10mA

≤ 1KΩ

4-20mA / 4-12-20mA

≤ 500Ω

 

AUXILLIARY POWER SUPPLY

0-110 VAC ± 10% 50/60 Hz 2VA Approx.

0-220 VAC ± 10% 50/60 Hz 2VA Approx.

0-24 VDC ± 10% 2Watts Approx.

0-48 VDC ± 10% 2Watts Approx.

0-110 VDC ± 10% 2Watts Approx.

0-220 VDC ± 10% 2Watts Approx.

 

View Complete Details

Yes, I am interested!

Meco-g R-rpt11,  Reactive Power Transducer - Powerline Transducer
Interested in this product?
Get Best Quote

Meco-g R-rpt11, Reactive Power Transducer - Powerline Transducer

Rs 2,520 / Piece(s)Get Latest Price

Minimum Order Quantity: 1 Piece(s)


"MECO-G" AC Reactive (VAR)Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable and are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.

GENERAL SPECIFICATIONS

 

SPECIFICATION

Accuracy

± 0.5% of Rated output, ± 0.2 % (Optional)

Output Ripple

0.2% RMS

Response

Less than 0.5 Sec.

Frequency

50 / 60 Hz.

Zero Adj.

± 2% Min

Span Adi.

±10 % Min.

Operating Temp.

0° ~ 50° C (RH < 90 %) Non - Condensing

Storage Temp

-20°C ~ 70°C

Overload Continuous

2 x Rated Current, 1.2 x Rated Voltage

Breakdown Impulse Voltage

4.5KV , 1 x 40µs (Without Dewing)

Tempreature Coefficient

0.03% / °C.

Dielectric Withstand Voltage 
between Input / Output / Power / Case

2 KV AC for 1 minute.

Insulation Resistance (@ 500V DC)

>100MΩ


>

TYPE

MODEL

INPUT RANGES

DIMENSION

SINGLE PHASE

R-RPT 11

-63.5,100, 110,415,440 V (ANY ONE)
0-1,2,2.5,5A (ANY ONE)

Size 2

3 PHASE-3 WIRE

R-RPT 33

Size 3

3 PHASE-4 WIRE

R-RPT 34

Size 3

 

DC OUTPUT RANGES

0-1V

≥ 1KΩ

0-5V

≥ 5KΩ

1-5V

≥ 5KΩ

0-10V

≥ 10KΩ

2-10V

≥ 10KΩ

0-1mA

≤ 10KΩ

0-5mA

≤ 2KΩ

0-10mA

≤ 1KΩ

4-20mA / 4-12-20mA

≤ 500Ω

 

AUXILLIARY POWER SUPPLY

0-110 VAC ± 10% 50/60 Hz 2VA Approx.

0-220 VAC ± 10% 50/60 Hz 2VA Approx.

0-24 VDC ± 10% 2Watts Approx.

0-48 VDC ± 10% 2Watts Approx.

0-110 VDC ± 10% 2Watts Approx.

0-220 VDC ± 10% 2Watts Approx.

View Complete Details

Yes, I am interested!

Meco-g R-rpt33 Reactive Power Transducer - Powerline Transduce
Interested in this product?
Get Best Quote

Meco-g R-rpt33 Reactive Power Transducer - Powerline Transduce

Rs 3,600 / Piece(s)Get Latest Price

Minimum Order Quantity: 1 Piece(s)

MECO-G" WATT Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.

GENERAL SPECIFICATION

Accuracy

± 0.5% of Rated output, ± 0.2 % (Optional)

Output Ripple

0.2% RMS

Response

Less than 0.5 Sec.

Frequency

50 / 60 Hz.

Zero Adj.

± 2% Min

Span Adi.

±10 % Min.

Operating Temp.

0° ~ 50° C (RH < 90 %) Non - Condensing

Storage Temp

-20°C ~ 70°C

Overload Continuous

2 x Rated Current, 1.2 x Rated Voltage

Breakdown Impulse Voltage

4.5KV , 1 x 40µs (without dewing.)

Tempreature Coefficient

0.03% / °C.

Dielectric Withstand Voltage 
between Input / Output / Power / Case

2 KV AC for 1 minute.

Insulation Resistance (@ 500V DC)

>100MΩ

 

TYPE

MODEL

INPUT RANGES

DIMENSION

SINGLE PHASE

R-WT 11

0-63.5,100,110,415,440 V (ANY ONE)
0-1,2,2.5,5A (ANY ONE)

Size 2

3 PHASE-3 WIRE

R-WT 33

Size 3

3 PHASE-4 WIRE

R-WT 34

Size 3

 

DC OUTPUT RANGES

0-1V

≥ 1KΩ

0-5V

≥ 5KΩ

1-5V

≥ 5KΩ

0-10V

≥ 10KΩ

2-10V

≥ 10KΩ

0-1mA

≤ 10KΩ

0-5mA

≤ 2KΩ

0-10mA

≤ 1KΩ

4-20mA / 4-12-20mA

≤ 500Ω

 

AUXILLIARY POWER SUPPLY

0-110 VAC ± 10% 50/60 Hz 2VA Approx.

0-220 VAC ± 10% 50/60 Hz 2VA Approx.

0-24 VDC ± 10% 2Watts Approx.

0-48 VDC ± 10% 2Watts Approx.

0-110 VDC ± 10% 2Watts Approx.

0-220 VDC ± 10% 2Watts Approx.

 

View Complete Details

Yes, I am interested!

Meco-g R-rpt34, Poewrline Reactive Power Transducer
Interested in this product?
Get Best Quote

Meco-g R-rpt34, Poewrline Reactive Power Transducer

Rs 3,780 / Piece(s)Get Latest Price

Minimum Order Quantity: 1 Piece(s)

MECO-G" WATT Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.

GENERAL SPECIFICATION

Accuracy

± 0.5% of Rated output, ± 0.2 % (Optional)

Output Ripple

0.2% RMS

Response

Less than 0.5 Sec.

Frequency

50 / 60 Hz.

Zero Adj.

± 2% Min

Span Adi.

±10 % Min.

Operating Temp.

0° ~ 50° C (RH < 90 %) Non - Condensing

Storage Temp

-20°C ~ 70°C

Overload Continuous

2 x Rated Current, 1.2 x Rated Voltage

Breakdown Impulse Voltage

4.5KV , 1 x 40µs (without dewing.)

Tempreature Coefficient

0.03% / °C.

Dielectric Withstand Voltage 
between Input / Output / Power / Case

2 KV AC for 1 minute.

Insulation Resistance (@ 500V DC)

>100MΩ

 

TYPE

MODEL

INPUT RANGES

DIMENSION

SINGLE PHASE

R-WT 11

0-63.5,100,110,415,440 V (ANY ONE)
0-1,2,2.5,5A (ANY ONE)

Size 2

3 PHASE-3 WIRE

R-WT 33

Size 3

3 PHASE-4 WIRE

R-WT 34

Size 3

 

DC OUTPUT RANGES

0-1V

≥ 1KΩ

0-5V

≥ 5KΩ

1-5V

≥ 5KΩ

0-10V

≥ 10KΩ

2-10V

≥ 10KΩ

0-1mA

≤ 10KΩ

0-5mA

≤ 2KΩ

0-10mA

≤ 1KΩ

4-20mA / 4-12-20mA

≤ 500Ω

 

AUXILLIARY POWER SUPPLY

0-110 VAC ± 10% 50/60 Hz 2VA Approx.

0-220 VAC ± 10% 50/60 Hz 2VA Approx.

0-24 VDC ± 10% 2Watts Approx.

0-48 VDC ± 10% 2Watts Approx.

0-110 VDC ± 10% 2Watts Approx.

0-220 VDC ± 10% 2Watts Approx.

 

View Complete Details

Yes, I am interested!

Meco-g  R-cmt, Powerline AC Current Transducer - One Phase
Interested in this product?
Get Best Quote

Meco-g R-cmt, Powerline AC Current Transducer - One Phase

Rs 2,070 / Piece(s)Get Latest Price

Minimum Order Quantity: 1 Piece(s)

MECO-G" AC Current Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.

GENERAL SPECIFICATION

Accuracy

± 0.5% of Rated output, ± 0.2 % (Optional)

Output Ripple

0.2% RMS

Response

Less than 0.5 Sec.

Frequency

50 / 60 Hz.

Zero Adj.

± 2% Min

Span Adi.

±10 % Min.

Operating Temp.

0° ~ 50° C (RH < 90 %) Non - Condensing

Storage Temp

-20°C ~ 70°C

Overload Continuous

2 x Rated Current, 1.2 x Rated Voltage

Breakdown Impulse Voltage

4.5KV, 1 x 40µs (without dewing.)

Tempreature Coefficient

0.03% / °C.

Dielectric Withstand Voltage 
between Input / Output / Power / Case

2 KV AC for 1 minute.

Insulation Resistance (@ 500V DC)

>100MΩ


 

TYPE

MODEL

INPUT RANGES

DIMENSION

CURRENT

(Single Phase)

R-CMT

0-0.5, 1.2, 2.5,5 Amps (anyone)

Size 1

 

CURRENT

(3 Phase 4 WIRE)

R-CMT34*

0-0.5, 1, 2, 2.5, 5 Amps (anyone)

Size 3

 

*Accuracy class 0.5% only available 
 

DC OUTPUT RANGES

0-1V

≥ 1KΩ

0-5V

≥ 5KΩ

1-5V

≥ 5KΩ

0-10V

≥ 10KΩ

2-10V

≥ 10KΩ

0-1mA

≤ 10KΩ

0-5mA

≤ 2KΩ

0-10mA

≤ 1KΩ

4-20mA

≤ 500Ω

 

AUXILLIARY POWER SUPPLY

0-110 VAC ± 10% 50/60 Hz 2VA Approx.

0-220 VAC ± 10% 50/60 Hz 2VA Approx.

0-24 VDC ± 10% 2Watts Approx.

0-48 VDC ± 10% 2Watts Approx.

0-110 VDC ± 10% 2Watts Approx.

0-220 VDC ± 10% 2Watts Approx.

 

View Complete Details

Yes, I am interested!

Meco-g R-cmt34  Ac Current Transducer - Powerline Transducer
Interested in this product?
Get Best Quote

Meco-g R-cmt34 Ac Current Transducer - Powerline Transducer

Rs 3,600 / Piece(s)Get Latest Price

Minimum Order Quantity: 1 Piece(s)

MECO-G" AC Current Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.

GENERAL SPECIFICATION

Accuracy

± 0.5% of Rated output, ± 0.2 % (Optional)

Output Ripple

0.2% RMS

Response

Less than 0.5 Sec.

Frequency

50 / 60 Hz.

Zero Adj.

± 2% Min

Span Adi.

±10 % Min.

Operating Temp.

0° ~ 50° C (RH < 90 %) Non - Condensing

Storage Temp

-20°C ~ 70°C

Overload Continuous

2 x Rated Current, 1.2 x Rated Voltage

Breakdown Impulse Voltage

4.5KV, 1 x 40µs (without dewing.)

Tempreature Coefficient

0.03% / °C.

Dielectric Withstand Voltage 
between Input / Output / Power / Case

2 KV AC for 1 minute.

Insulation Resistance (@ 500V DC)

>100MΩ


 

TYPE

MODEL

INPUT RANGES

DIMENSION

CURRENT

(Single Phase)

R-CMT

0-0.5, 1.2, 2.5,5 Amps (anyone)

Size 1

 

CURRENT

(3 Phase 4 WIRE)

R-CMT34*

0-0.5, 1, 2, 2.5, 5 Amps (anyone)

Size 3

 

*Accuracy class 0.5% only available 
 

DC OUTPUT RANGES

0-1V

≥ 1KΩ

0-5V

≥ 5KΩ

1-5V

≥ 5KΩ

0-10V

≥ 10KΩ

2-10V

≥ 10KΩ

0-1mA

≤ 10KΩ

0-5mA

≤ 2KΩ

0-10mA

≤ 1KΩ

4-20mA

≤ 500Ω

 

AUXILLIARY POWER SUPPLY

0-110 VAC ± 10% 50/60 Hz 2VA Approx.

0-220 VAC ± 10% 50/60 Hz 2VA Approx.

0-24 VDC ± 10% 2Watts Approx.

0-48 VDC ± 10% 2Watts Approx.

0-110 VDC ± 10% 2Watts Approx.

0-220 VDC ± 10% 2Watts Approx.

 

View Complete Details

Yes, I am interested!

Meco-g R-vmt, Powerline Ac Voltage Transducer - One Phase
Interested in this product?
Get Best Quote

Meco-g R-vmt, Powerline Ac Voltage Transducer - One Phase

Rs 2,070 / PieceGet Latest Price

Minimum Order Quantity: 1 Piece

MECO-G" AC Voltage Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Tele metering, Dataloggers, PLC's, SCADA systems and control applications.

GENERAL SPECIFICATIONS

 

SPECIFICATION

Accuracy

± 0.5% of Rated output, ± 0.2 % (Optional)

Output Ripple

0.2% RMS

Response

Less than 0.5 Sec.

Frequency

50 / 60 Hz.

Zero Adj.

± 2% Min

Span Adi.

±10 % Min.

Operating Temp.

0° ~ 50° C (RH < 90 %) Non - Condensing

Storage Temp

-20°C ~ 70°C

Overload Continuous

2 x Rated Current, 1.2 x Rated Voltage

Breakdown Impulse Voltage

4.5KV , 1 x 40µs (without dewing.)

Tempreature Coefficient

0.03% /°C.

Dielectric Withstand Voltage 
between Input / Output / Power / Case

2 KV AC for 1 minute.

Insulation Resistance (@ 500V DC)

>100MΩ

 

TYPE

MODEL

INPUT RANGES

DIMENSION

VOLTAGE
(SINGLE PHASE)

R-VMT

0-63.5,100, 110,230,300,440,500 Volts (any one)

Size 1

VOLTAGE 
(3 Phase 4 WIRE)

R-VMT34*

0-63.5,110,230,300,440,500 (any one)

Size 3

*Accuracy class 0.5% only available 
 

DC OUTPUT RANGES

0-1V

≥ 1KΩ

0-5V

≥ 5KΩ

1-5V

≥ 5KΩ

0-10V

≥ 10KΩ

2-10V

≥ 10KΩ

0-1mA

≤ 10KΩ

0-5mA

≤ 2KΩ

0-10mA

≤ 1KΩ

4-20mA

≤ 500Ω

 

AUXILLIARY POWER SUPPLY

0-110 VAC ± 10% 50/60 Hz 2VA Approx.

0-220 VAC ± 10% 50/60 Hz 2VA Approx.

0-24 VDC ± 10% 2Watts Approx.

0-48 VDC ± 10% 2Watts Approx.

0-110 VDC ± 10% 2Watts Approx.

0-220 VDC ± 10% 2Watts Approx.

 

 

View Complete Details

Yes, I am interested!

Meco-g R-vmt34, Ac Voltage Transducer , Power Line Transducer
Interested in this product?
Get Best Quote

Meco-g R-vmt34, Ac Voltage Transducer , Power Line Transducer

Rs 3,600 / Piece(s)Get Latest Price

Minimum Order Quantity: 1 Piece(s)

MECO-G" AC VoltageTransducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.

GENERAL SPECIFICATIONS

 

SPECIFICATION

Accuracy

± 0.5% of Rated output, ± 0.2 % (Optional)

Output Ripple

0.2% RMS

Response

Less than 0.5 Sec.

Frequency

50 / 60 Hz.

Zero Adj.

± 2% Min

Span Adi.

±10 % Min.

Operating Temp.

0° ~ 50° C (RH < 90 %) Non - Condensing

Storage Temp

-20°C ~ 70°C

Overload Continuous

2 x Rated Current, 1.2 x Rated Voltage

Breakdown Impulse Voltage

4.5KV , 1 x 40µs (without dewing.)

Tempreature Coefficient

0.03% /°C.

Dielectric Withstand Voltage 
between Input / Output / Power / Case

2 KV AC for 1 minute.

Insulation Resistance (@ 500V DC)

>100MΩ

 

TYPE

MODEL

INPUT RANGES

DIMENSION

VOLTAGE
(SINGLE PHASE)

R-VMT

0-63.5,100, 110,230,300,440,500 Volts (any one)

Size 1

VOLTAGE 
(3 Phase 4 WIRE)

R-VMT34*

0-63.5,110,230,300,440,500 (any one)

Size 3

*Accuracy class 0.5% only available 
 

DC OUTPUT RANGES

0-1V

≥ 1KΩ

0-5V

≥ 5KΩ

1-5V

≥ 5KΩ

0-10V

≥ 10KΩ

2-10V

≥ 10KΩ

0-1mA

≤ 10KΩ

0-5mA

≤ 2KΩ

0-10mA

≤ 1KΩ

4-20mA

≤ 500Ω

 

AUXILLIARY POWER SUPPLY

0-110 VAC ± 10% 50/60 Hz 2VA Approx.

0-220 VAC ± 10% 50/60 Hz 2VA Approx.

0-24 VDC ± 10% 2Watts Approx.

0-48 VDC ± 10% 2Watts Approx.

0-110 VDC ± 10% 2Watts Approx.

0-220 VDC ± 10% 2Watts Approx.

 

 

View Complete Details

Yes, I am interested!

Meco-g R-ft Powerline Frequency Transducer
Interested in this product?
Get Best Quote

Meco-g R-ft Powerline Frequency Transducer

Rs 2,070 / Piece(s)Get Latest Price

Minimum Order Quantity: 1 Piece(s)

"MECO-G" AC Frequency Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.

GENERAL SPECIFICATIONS

 

SPECIFICATION

Accuracy

± 0.5% of Rated output, ± 0.2 % (Optional)

Output Ripple

0.2% RMS

Response

Less than 0.5 Sec.

Frequency

50 / 60 Hz.

Zero Adj.

± 2% Min

Span Adi.

±10 % Min.

Operating Temp.

0° ~ 50° C (RH < 90 %) Non - Condensing

Storage Temp

-20°C ~ 70°C

Overload Continuous

2 x Rated Current, 1.2 x Rated Voltage

Breakdown Impulse Voltage

4.5KV , 1 x 40µs (without dewing.)

Tempreature Coefficient

0.03% / °C.

Dielectric Withstand Voltage 
between Input / Output / Power / Case

2 KV AC for 1 minute.

Insulation Resistance (@ 500V DC)

>100MΩ

 

TYPE

MODEL

INPUT RANGES

DIMENSION

FREQUENCY

(Input Voltage)

R-FT

45-55, 40-60, 55-65, 360-440 Hz (anyone)

0-63.5, 110, 230, 440 V (anyone)

Size 1

 

DC OUTPUT RANGES

0-1V

≥ 1KΩ

0-5V

≥ 5KΩ

1-5V

≥ 5KΩ

0-10V

≥ 10KΩ

2-10V

≥ 10KΩ

0-1mA

≤ 10KΩ

0-5mA

≤ 2KΩ

0-10mA

≤ 1KΩ

4-20mA

≤ 500Ω

 

AUXILLIARY POWER SUPPLY

0-110 VAC ± 10% 50/60 Hz 2VA Approx.

0-220 VAC ± 10% 50/60 Hz 2VA Approx.

0-24 VDC ± 10% 2Watts Approx.

0-48 VDC ± 10% 2Watts Approx.

0-110 VDC ± 10% 2Watts Approx.

0-220 VDC ± 10% 2Watts Approx.

 

 

View Complete Details

Yes, I am interested!

Meco-g R-dti Dc Isolation Transducer, Power Line Transducer
Interested in this product?
Get Best Quote

Meco-g R-dti Dc Isolation Transducer, Power Line Transducer

Rs 2,970 / Piece(s)Get Latest Price

Minimum Order Quantity: 1 Piece(s)


"MECO-G" Signal Isolating and DC Isolation Transducers provide a stable ripple free & optically Isolated DC output signal for various DC voltage & current Input signals. These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.

GENERAL SPECIFICATION

Accuracy

± 0.5% of Rated output, ± 0.2 % (Optional)

Output Ripple

0.2% RMS

Response

Less than 0.5 Sec.

Frequency

50 / 60 Hz.

Zero Adj.

± 2% Min

Span Adi.

±10 % Min.

Operating Temp.

0° ~ 50° C (RH < 90 %) Non - Condensing

Storage Temp

-20°C to 70°C

Overload Continuous

2 x Rated Current, 1.2 x Rated Voltage

Breakdown Impulse Voltage

4.5KV , 1 x 40µs (Without Dewing)

Tempreature Coefficient

0.03% / °C.

Dielectric Withstand Voltage 
between Input / Output / Power / Case

2 KV AC for 1 minute.

Insulation Resistance (@ 500V DC)

>100MΩ

 

INPUT RANGES ANY ONE)

0-75mV, 100mV, 1V, 5V, 10V, 1-5V, 2-10V, 360V

0-1mA, 0-5mA, 0-10mA, 2-10mA, 0-20mA, 4-20mA.

Model: R-DTI can accept both negative and positive input signals.
Model: R-SIT can only accept positive input signals. 

DC OUTPUT RANGES

0-1V

≥ 1KΩ

0-5V

≥ 5KΩ

1-5V

≥ 5KΩ

0-10V

≥ 10KΩ

2-10V

≥ 10KΩ

0-1mA

≤ 10KΩ

0-5mA

≤ 2KΩ

0-10mA

≤ 1KΩ

4-20mA / 4-12-20mA

≤ 500Ω

 

AUXILLIARY POWER SUPPLY

0-110 VAC ± 10% 50/60 Hz 2VA Approx.

0-220 VAC ± 10% 50/60 Hz 2VA Approx.

0-24 VDC ± 10% 2Watts Approx.

0-48 VDC ± 10% 2Watts Approx.

0-110 VDC ± 10% 2Watts Approx.

0-220 VDC ± 10% 2Watts Approx.

 

 

View Complete Details

Yes, I am interested!

Pressure Transmitter Transducer
Interested in this product?
Get Best Quote
With the support of our authentic vendors, we are able to bring forth advanced range of Pressure Transmitter Transducer. These superlative products are high in performance, best in quality and are supplied all across the nation. We maintain huge marketing channel and provide our products in best specifications to various clients at beneficial market range.

Features:

  • Highly reliable
  • Sustainable
  • Superior performance

View Complete Details

Yes, I am interested!

Meco-g R-sit,  Single Isolating Transmitter
Interested in this product?
Get Best Quote

Meco-g R-sit, Single Isolating Transmitter

Rs 1,620 / Piece(s)Get Latest Price

Minimum Order Quantity: 1 Piece(s)

Meco-g R-sit,  Single Isolating Transmitter (with Optical Is)

"MECO-G" Signal Isolating and DC Isolation Transducers provide a stable ripple free & optically Isolated DC output signal for various DC voltage & current Input signals. These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.

GENERAL SPECIFICATION

Accuracy

± 0.5% of Rated output, ± 0.2 % (Optional)

Output Ripple

0.2% RMS

Response

Less than 0.5 Sec.

Frequency

50 / 60 Hz.

Zero Adj.

± 2% Min

Span Adi.

±10 % Min.

Operating Temp.

0° ~ 50° C (RH < 90 %) Non - Condensing

Storage Temp

-20°C to 70°C

Overload Continuous

2 x Rated Current, 1.2 x Rated Voltage

Breakdown Impulse Voltage

4.5KV , 1 x 40µs (Without Dewing)

Tempreature Coefficient

0.03% / °C.

Dielectric Withstand Voltage 
between Input / Output / Power / Case

2 KV AC for 1 minute.

Insulation Resistance (@ 500V DC)

>100MΩ

 

INPUT RANGES ANY ONE)

0-75mV, 100mV, 1V, 5V, 10V, 1-5V, 2-10V, 360V

0-1mA, 0-5mA, 0-10mA, 2-10mA, 0-20mA, 4-20mA.

Model: R-DTI can accept both negative and positive input signals.
Model: R-SIT can only accept positive input signals. 

DC OUTPUT RANGES

0-1V

≥ 1KΩ

0-5V

≥ 5KΩ

1-5V

≥ 5KΩ

0-10V

≥ 10KΩ

2-10V

≥ 10KΩ

0-1mA

≤ 10KΩ

0-5mA

≤ 2KΩ

0-10mA

≤ 1KΩ

4-20mA / 4-12-20mA

≤ 500Ω

 

AUXILLIARY POWER SUPPLY

0-110 VAC ± 10% 50/60 Hz 2VA Approx.

0-220 VAC ± 10% 50/60 Hz 2VA Approx.

0-24 VDC ± 10% 2Watts Approx.

0-48 VDC ± 10% 2Watts Approx.

0-110 VDC ± 10% 2Watts Approx.

0-220 VDC ± 10% 2Watts Approx.

 

 

 

 

View Complete Details

Yes, I am interested!

Meco-g R-tpt Tap Position Transducer, Powerline Transducer
Interested in this product?
Get Best Quote

Meco-g R-tpt Tap Position Transducer, Powerline Transducer

Rs 2,970 / Piece(s)Get Latest Price

Minimum Order Quantity: 1 Piece(s)


"MECO-G" Tap Position Transducers converts a resistance input to a standard DC output signal which is directly proportional to the input resistance. This DC output signal is Optically Isolated, Ripple Free and Stable. These accurate and reliable outputs are suitable for Telemetering, Data Loggers, PLC′s and SCADA systems

GENERAL SPECIFICATIONS

Resistance Input

Aux. Supply 24VDC, 48VDC, 110VDC, 220VDC, 110VAC, 230VAC (Any One)

Potentiometric Resistance input from 
transformer Tap position.

Upto 99 transformer taps 100 KΩ max

0-230V AC ± 10% 50/60 Hz
0-110V AC ± 10% 50/60 Hz
0-48V DC ± 10%
0-24V DC ± 10%
85-265V AC/DC

1.8VA APPROX
1.8VA APPROX
2 WATTS APPROX
2 WATTS APPROX
1.8VA APPROX

OUTPUT

LOAD RESISTANCE

OUTPUT

LOAD RESISTANCE

0-1V
0-5V 
0-10V 
1-5V

≥1KΩ
≥5KΩ
≥10KΩ
≥5KΩ

0-1mA
0-5mA
0-10mA
4-20mA

≤1KΩ
≤2KΩ
≤1KΩ
≤500KΩ

 

TEMPERATURE TRANSDUCER

"MECO-G" Temperature Transducers converts a resistance input into a standard DC output signal which is directly proportional to the input resistance. This DC output signal is Optically Isolated, Ripple Free and Stable. These accurate and reliable outputs are suitable for Telemetering, Data Loggers, PLC′s and SCADA systems.

Input ( PT-100 Sensor)

Aux. Supply 24VDC, 48VDC, 110VDC, 220VDC, 110VAC, 230VAC (Any One)

Resistive Input from PT-100 Sensor

0-230V AC ± 10% 50/60 Hz
0-110V AC ± 10% 50/60 Hz
0-48V DC ± 10%
0-24V DC ± 10%
85-265V AC/DC

1.8VA APPROX
1.8VA APPROX
2 WATTS APPROX
2 WATTS APPROX
1.8VA APPROX

OUTPUT

LOAD RESISTANCE

OUTPUT

LOAD RESISTANCE

0-1V
0-5V 
0-10V 
1-5V

≥1KΩ
≥5KΩ
≥10KΩ
≥5KΩ

0-1mA
0-5mA
0-10mA
4-20mA

≤1KΩ
≤2KΩ
≤1KΩ
≤500KΩ

 

 

 

View Complete Details

Yes, I am interested!

PH Electrode
Interested in this product?
Get Best Quote

PH Electrode

Get Latest Price

With the support of our employees, we bring forth high quality range of PH Electrode. These advanced products are precisely engineered by reliable firms and are highly sustainable. We are the most reliable firm and provide our superlative products in perfect size and specifications’. Our quality tested products are well verified and are safely supplied at the most economical market ranges. 

 Features:
 
  • Superior quality
  • Highly reliable
  • Strong and sustainable


Additional Information:

  • Item Code: PE-03

View Complete Details

Yes, I am interested!

Signal Isolator Converter
Interested in this product?
Get Best Quote
We provide best range of Signal Isolator Converter which is accurate in size and are high in demand. Our superlative products are highly functional, best in performance, easy to use and are superior in features. They are available in perfect size, specifications and are high in demand. We ensure strong and superlative products which are available at attractive market ranges.

Features:

  • Superior quality
  • Highly sustainable
  • Perfect size

View Complete Details

Yes, I am interested!

Temperature Transmitter
Interested in this product?
Get Best Quote

Temperature Transmitter

Get Latest Price

Temperature Transmitter

Additional Information:

  • Item Code: TMT-190-B

View Complete Details

Yes, I am interested!

Thermocouple and RTD Temperature Sensor
Ask for Details

Meco-g R-pt100  Powerline Temperature Transducer

Meco-g R-pt100 Powerline Temperature Transducer

Rs 2,970 / Piece(s)Get Latest Price

Minimum Order Quantity: 1 Piece(s)

Ask for Details
3.9/5★★★★★★★★★★

Reviewed by 22 Users

5 star10

4 star6

3 star2

2 star1

1 star3

User Satisfaction

Response75%

Quality100%

Delivery100%

Most Relevant Reviews

N

Nitesh ★★★★★ ★★★★★

13-December-20

Quality

A

Amit Batliwala ★★★★★ ★★★★★

20-November-20

Response

Quality

Delivery

Get in touch with us

Reach Us

Instruments ZoneNo. 395/B, Clerk Colony, Opposite ITI College Pardeshipura, Sukhlia, Indore-452011, Madhya Pradesh, India

Vineet Mittal (Proprietor)

View Mobile Number74% Call Response Rate

Send SMS
Send Email
Leave a Message, we will call you back!
Send your enquiry to this supplier
I agree to the terms and privacy policy

We Accept Online Payments

All Rights Reserved (Terms of Use)