Indoor Resin Cast Dry Type CT

Our range of products include 33KV Indoor Resin Cast Dry Type CT and 11KV Indoor Resin Cast Dry Type CT.

33KV Indoor Resin Cast Dry Type CT
Interested in this product?
Get Best Quote

33KV Indoor Resin Cast Dry Type CT

Rs 10,000 / PieceGet Latest Price

Accuracy ClassFor Metering: 0.2S,0.5S,1.0 & 3.00,or Protection: 5P,10P,15P & PS, 0.5, 0.2
Highest System Voltage36 KV (r.m.s.)
Number of CoresUpto 3 cores
Output BurdenUpto 60VA, 0.8 pf Lagging
Type of ConstructionEpoxy Resin cast suitable for different panels
Power Frequency Dry70 KV ( r.m.s.)
Lightning Impulse Withstand Voltage170 KV ( r.m.s.)
PD Measuring Voltage23 V
Permissible Voltage50 V
Rated Primary CurrentUpto 2000 Amp
Rated Secondary Current1 Amp / 5 Amp / 0.577 Amp
Ith Duration0.5 to 3.0 Second
Short Time Dynamic Current2.5 X Ith KA (Peak)

33KV Indoor Resin Cast Dry Type CT

View Complete Details

Yes, I am interested!

11KV Indoor Resin Cast Dry Type CT
Interested in this product?
Get Best Quote

11KV Indoor Resin Cast Dry Type CT

Rs 10,000 / PieceGet Latest Price

Accuracy Class0.2, For Metering: 0.2S,0.5S,1.0 & 3.00,or Protection: 5P,10P,15P & PS, 0.5
Highest System Voltage12 KV ( r.m.s.)
Short Time Dynamic Current2.5 X Ith KA (Peak)
Number of CoresUpto 3 cores
Output BurdenUpto 60VA, 0.8 pf Lagging
Type of ConstructionEpoxy Resin cast suitable for different panels
Power Frequency Dry28 KV ( r.m.s.)
Lightning Impulse Withstand Voltage75 KV ( r.m.s.)
PD measuring Voltage7.6 V
Permissible Voltage50 V
Rated Primary CurrentUpto 2000 Amp
Rated Secondary Current1 Amp / 5 Amp / 0.577 Amp

Features:
  • CRGO M-4 or M-3 grade toroidal cores are wound with secondary enameled copper wire, which is distributed uniformly on the periphery of the core to achieve minimum leakage reactance. Inter-layer insulation is provided to avoid secondary winding short-circuiting in times of fault in the system
  • Primary winding consists of flexible rope of copper and has the required number of turns in one or more sections. Their ends are crimped and taken out through copper rectangular strips or rods as per customer requirement
  • Insulation consists of high quality epoxy resin. Initially, the secondary wound cores are mounted & cast in the required mould ensuring minimum clearance as per the voltage requirements. Then the primary winding is cast along with the above in the required mould. Casting is done under vacuum in the epoxy resin cast plant specifically dedicated for the purpose. It has mixing & pouring chambers with controlled temperature and vacuum conditions. Procedure of casting is followed strictly by the resin manufacturer for the particular resin-mix
  • Curing is done at 1000 C or at room temperature for the specified time depending upon the type of resin used
  • Each transformer undergoes all the routine tests before dispatch and is delivered safe at site duly packed. However, following precautions must be observed for its intended performance: Transformer is to be unpacked fully before carrying out site tests. Before energizing, all the secondary terminals not in use are to be short-circuited and grounded. Primary connection is to be tightened sufficiently to avoid hot connection
  • As the transformer is fully encapsulated, routine maintenance is limited to clean the outer surface only