Manufacturer of a wide range of products which include Grounding System Health Assessment Audit.

Grounding System Health Assessment Audit
  • Grounding System Health Assessment Audit
  • Grounding System Health Assessment Audit
  • Grounding System Health Assessment Audit
  • Grounding System Health Assessment Audit
Interested in this product?
Get Best Quote

Grounding System Health Assessment Audit

Get Latest Price

Minimum Order Quantity: 1 Unit

Application AreaIndustrial
Requirement TypeCorporate
Audit TypeFault Level Evaluation
Mode of ReportSoft Copy
Type of Service ContractAs per requirement
Safety Audit TypeElectrical Safety Audit

INTRODUCTION

JEF Earthing System ‘Health Assessment’ ensures the healthiness of complete Earthing system. It is important that the Earthing system is inspected periodically to ensure the effectiveness. Since the majority of Earthing System is buried underground/inaccessible, it suffers from “OUT OF SIGHT IS OUT OF MIND” syndrome. Unseen Components like Equipment Earth Conductor (Strip), Earth Grids / Mats which are buried or inaccessible, tend to be taken for granted or ignored, though they are crucial
A Complete Earthing System with all its components- Equipment Earth Conductor, Earth Electrode, and Earth Grid / Mat should offer low resistance path for fault current to flow so that breakers trip in time to prevent accidents such as -Fire, Short Circuit, and Electric Shock and so on.

NEED FOR JEF EARTHING HEALTH ASSESSMENT AUDIT
  • Normally Earth Electrode (Pit) Resistance alone is measured periodically. Electrical System is deemed to be safe with a low Earth Electrode Resistance.
  • The Integrity of Earth Conductor (Strip) between Earth Electrode and Equipment is rarely checked.
  • Hence Breaker may not trip even if Earth Electrode Resistance is low.
  • In reality, timely operation of the breaker (Electrical Safety) depends on the resistance of earth loop formed by equipment earth conductor (Strip), earth electrode and phase conductor.
  • System modifications and Deterioration of Earthing System can render the original design calculations of protection system (breakers) invalid.
  • JEF’s assessment methodology covers this crucial gap by checking all the above parameters, thereby ensuring timely operation of the breakers to prevent accidents/damage.
  • Carried out on live systems without Shutdown using sophisticated meters and practices.
  • By emphasizing and encouraging the use of right personal protection equipment.

A) EARTHING SYSTEM AUDITS – EHVACTIVITY

  • Soil Resistivity Test
  • Earth Electrode Resistance Test
  • Riser Integrity Test
  • Grid Integrity Test
  • Effect of Corrosion
  • Touch and Step Potential Test
  • Modeling and Simulation of GPR, Metal to Metal Voltages and circulating currents
METHODOLOGY/DELIVERABLE
  • Wenner Method
  • Fall of Potential or Stake Less Method
  • Ensuring Equipment Connection to Grid
  • Ensuring No Breakage in Grid
  • Available Conductor Area WRT Fault Current
  • Ensuring Human Safety
  • Computer Aided Software
BENEFITS
  • Pin Points Open Risers and Grid Conductors
  • Identifies locations with unsafe touch & step potentials in the substation
  • Compliance with Standards
  • Ensures Human and Equipment Safety
B) EARTHING SYSTEM AUDITS – LVACTIVITY
  • Soil Resistivity Test
  • Earth Electrode Resistance Test
  • Earth Loop Impedance Test
  • Prospective Fault Current Test
  • Riser Integrity Test
  • Effect of Corrosion
METHODOLOGY/DELIVERABLE
  • Wenner Method
  • Fall of Potential or Stake Less Method
  • Whether within limits or not
  • Verify Breaker Activation & Tripping Time
  • Ensuring Equipment Connection to Grid
  • Physical Measurement
BENEFITS
  • Ensures timely tripping of breakers in case of a fault, thus preventing short circuit, fire, shocks and so on
  • Effective compliance with Safety Standards & Norms
REFERENCE STANDARDS

IEEE 81-2012,IEE Regulation,IEEE 80 – 2013,IEEE 81-2012,BS 7430,IS 3043,CBIP manual