Brand | Schneider |
Model Name/Number | RE17RAMU |
Power/Voltage | 240 V |
Width | 17.5 mm |
Height | 90 mm |
Depth | 72 mm |
Product Or Component Type | Dual function relay |
discrete output type | Relay |
Device short name | RE17R |
Time delay type | Power on-delay |
Nominal output current | 8 Amp |
contacts type and composition | 1 C/O |
Contacts material | Cadmium free |
Control Type | Selector switch front panel |
Frequency | 50 Hz |
Release of Input voltage | 10 V |
Tightening Torque | 1 Nm conforming to IEC 60947-1 |
Housing Material | Self Extinguishing |
Repeat Accuracy | +/- 0.5 % conforming to IEC 61812-1 |
Temperature Drift | +/- 0.05 %/ Degree Celsius |
Voltage Drift | +/- 0.2 %/V |
Setting Accuracy of time delay | +/- 10 % of full scale at 25 DegreeC conforming to IEC 61812-1 |
Control signal pulse width | 100 ms with load in parallel typical |
Insulation Resistance | 100 MOhm at 500 V DC conforming to IEC 60664-1 |
Reset time | 120 ms on de-energisation typical |
On-load factor | 100 % |
Power Consumption | 32 VAmp at 240 V AC |
Minimum switching current | 10 mAmp at 5 V DC |
Maximum switching current | 8 A AC/DC |
Maximum Switching voltage | 250 V AC |
Breaking Capacity | 2000 VA |
Operating frequency | 10 Hz |
Range of product | Harmony Timer Relays |
Electrical Durability | 100000 cycles (8 A at 250 V AC maximum) for resistive load |
Mechanical durability | 10000000 cycles |
Dielectric strength | 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1 |
Rated impulse withstand voltage | 5 kV during 1.2/50 us |
Power on Delay | 100 ms |
Marking | CE |
Creepage distance | 4 kV/3 conforming to IEC 60664-1 |
Safety reliability data | B10d = 270000 |
Mounting position | Any position in relation to normal vertical mounting plane |
Mounting support | 35 mm DIN rail conforming to EN/IEC 60715 |
Net Weight | 0.07 kg |
Time delay type c | A, At |
Functionality | On-delay timing |
Compatibility code | RE17 |
Product Details :-
Harmony Timer are timing relays designed to time events in industrial automationsystems by closing and opening contacts before, during, or after a set time period.
They are designed for hard-wired logic automated systems to complement thefunctions of industrial progammable logic controllers (PLCs).
They are suitable for a wide range of applications, including:
- Machines: single machine, and industrial automation and processes
- Buildings: lighting control, access control door locks, roller shutters
- Water segment: pumping and irrigation systems
- HVAC: fans and centralized water systems
- Depending on the product model, these relays support multiple time ranges.
- Modular DIN rail mounted timing relays
The Harmony Timer relays also feature:
- Wide power supply range from 24 to 240 V z
- Single or multi timing ranges from 0.02 s to 999 hrs
- Screw or spring connection terminals
- Relay or solid-state output
- Conformity to IEC 61812-1 and EN 61812-1 standards
- UL, CSA, GL, RCM, EAC, CCC, and China ROHS compliance
- Easy to set up with wiring diagrams on the side of the product
Environment | |
immunity to microbreaks | 20 ms |
standards | 2006/95/EC |
2004/108/EC | |
IEC 61812-1 | |
EN 61000-6-3 | |
EN 61000-6-1 | |
EN 61000-6-4 | |
EN 61000-6-2 | |
Product certifications | CSA |
CULus | |
GL | |
Ambient air temperature for storage | -30…60 °C |
Ambient air temperature for operation | -20…60 °C |
IP degree of protection | IP20 (terminal block) conforming to IEC 60529 |
IP40 (housing) conforming to IEC 60529 | |
IP50 (front panel) conforming to IEC 60529 | |
vibration resistance | 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 |
shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
Relative humidity | 93 % without condensation conforming to IEC 60068-2-30 |
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Brand | Schneider |
Model Name/Number | LRE35 |
Mounting Support | Under contactor Plate, with specific accessories Rail, with specific accessories |
Range | EasyPact |
Product Name | EasyPact TVS |
Product or component type | Differential thermal overload relay |
Device short name | LRE |
Relay application | Motor protection |
Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1 |
Colour | Grey (RAL 7011) |
Network type | AC |
Network frequency | 50 Hz |
Thermal overload class | Class 10A conforming to IEC 60947-4-1 |
Signalling function | Relay trip indicator |
Thermal protection adjustment range | 38 Amp |
Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
Mechanical robustness | Shocks: 6 Gn for 11 ms conforming to IEC 60068-2-7 Vibrations: 3 Gn conforming to IEC 60068-2-6 |
Auxiliary contact composition | 1 NO + 1 NC |
conventional free air thermal current | 5 Amp for signalling circuit |
Rated operational voltage | <= 690 V AC |
Associated fuse rating | 40 A aM for power circuit 80 A gG for power circuit 5 A gG for signalling circuit |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
[Uimp] rated impulse withstand voltage | 6 kV |
Local Signalling | Trip indicator |
Control type | Push-button red stop: |
Temperature Compensation | 60 Degree Celsius |
Recommended tightening torque | Power circuit: 2.5 N.m - on screw clamp terminals Signalling circuit: 1.7 N.m - on screw clamp |
Height | 44.5 mm |
Width | 45 mm |
Depth | 70 mm |
Net weight | 0.13 kg |
Environment | ||
standards | IEC 60947-5-1 | |
IEC 60947-4-1 | ||
Product certifications | EAC | |
protective treatment | TH conforming to IEC 60068 | |
IP degree of protection | IP20 conforming to IEC 60529 | |
ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 | |
-20…70 °C with derating | ||
Ambient air temperature for storage | -60…80 °C | |
fire resistance | 850 °C conforming to IEC 60068-2-1 | |
dielectric strength | 6 kV at 50 Hz conforming to IEC 60255-5 | |
electromagnetic compatibility | Surge withstand: 6 kV conforming to IEC 60801-5 |
Connections - terminals
Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: solid without cable end.