Model Name/Number | ECG 1C |
Brand | K-Life |
Machine Type | Digital |
Number of Channels | 1 |
Digital Display | Yes |
Digital Filtering | Yes |
Operating Mode | Automatic |
Ecg Lead Annotation | Yes |
Recording Method | Leaflet attached |
Iso Certification | Yes |
Visual Alarm | Yes |
Standard Thermal Paper | Yes |
Carry Handle | Yes |
Qwerty Alphanumeric Keyboard | Yes |
After Sales Services | Yes |
Lead | 12 leads |
Paper Speed | 25mm/s, 50mm/s (Error +-5%) |
LCD Display | 2.7" |
Input way | Floating and defibrillation protection |
Frequency response | 0.05Hz~150Hz (-3 dB~0.4 dB) |
EMG interference filter | 35 Hz (-3dB) |
Sensitivity choice | 5, 10, 20 mm/mV (Error +-5%) |
Standard sensitivity | 10mm/mV +-0.2% |
Enduring polarization voltage | +-300mV |
Classification | Class I, CF applied part |
Recording papers | 50mm (W) x20m (L) |
Recording | Auto and Manual |
Recording Way | Thermal Printing System |
Machine Size | 315 (L) x 215 (W) x 77 (H) mm |
Machine Net Weight | 1.5Kg |
Features:
- AC/DC Operated
- Rechargeable Lithium Battery
- The device can record single channel ECG wave form and can remark the lead sign, sensitivity paper speed and filter state
- It can store 160 patient’s data, more convenient for data review & statistics
- Portable, Light weight and sturdy design
- Mode of printing : Automatic/Manual
- Output system : High resolution thermal - array (8dots/mm), non-adjustable
- Digital signal processor for effective inhibition of AC,EMG and DFT, receive the better ECG waveform
- Basic Software : For data transfer & print
- Advance Software : For cardiac analysis
- Input Impedance: ≤50M
- Time Constant: Time ≥3.2s
- CMRR: ≤60 dB, ≤100 dB (add filter)
- Patient leak current: ≤10μA
- Enduring polarization voltage: ±300mV
- Noise Level: ≤15μVp-p
- Fuse Specification: 2pcs (5*20mm AC time lags); T1.6AL250V (Power Supply : 220V)
Additional Information:
- Item Code: 01
- Production Capacity: 100
- Delivery Time: 2 days
- Packaging Details: Single piece packing with all accessories
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Model Name/Number | CONECT 3C |
Machine Type | Digital |
Brand | Contec |
Digital Display | Yes |
Digital Filtering | Yes |
Operating Mode | Automatic |
Lead | 3 leads |
Ac Filter | 50/60HZ |
LCD Display | 3.5" |
Input way | Floating and defibrillation protection |
Frequency response | .05Hz~150Hz (-3 dB~0.4 dB) |
EMG interference filter | 35 Hz (-3dB) |
Sampling Rate | 1000HZ |
Recording Way | Thermal printing system |
Recording papers | 80mm (W) x 20 m (L) |
Classification | Class I,CF applied part |
Recording | Auto and Manual |
Machine Size | 315 (L) x 215 (W) x 77 (H) mm |
Machine Net Weight | 1.7Kg |
Features:
THREE CHANNEL ECG MACHINE:
- AC/DC Operated
- 3 channel ECG with Interpretation
- Rechargeable Lithium Battery
- Simultaneous display 3/6/12 leads ECG waveform and can remark the lead sign, sensitivity paper speed and filter state
- Data interpretation
- It can store more than 1000 patient's data (Cases), more convenient for data review & statistics
- Portable, Light weight and sturdy design
- Mode of printing : Automatic/Manual Printing Modes
- Measurement parameter: HR, P-R interval P Duration, QRS Duration, Q Interval, Q-Tc, P Axis, QRS Axis, T Axis, R (V5), S(V1), R(V5) + S(V1)
- Patient leak current: ≤10μA
- Time Constant: Time ≥3.2s
- CMRR: ≤60 dB, ≤100 dB (add filter)
- Paper Speed: Auto record : 25mm/s, 50mm/s Manual record : 5, 10, 25, 50mm/s Rhythm record : 25mm/s, 50mm/s
- Enduring polarization voltage: ±500mV
- Sensitivity choice: 5, 10, 20 mm/mV (Error : ±5%)
- Standard sensitivity: 10mm/mV ±0.2%
- Fuse Specification: 2pcs (5*20mm AC time lags); T1.6AL250V (Power Supply : 220V)
Printing modes:
- 4*3
- Auto 3*4+1
- Auto 3*4
- Auto 2*6+1
- Auto 2*6
- Auto 3-2+1
- Auto 3-2
- Rhythm 4
- Rhythm 3
- Rhythm 2
- Manual Mode
Optional:
- Touch Screen
- Basic Software: For data transfer & Print
- Advance Software: For cardiac analysis
Additional Information:
- Production Capacity: Any
- Delivery Time: one week
- Packaging Details: Individual poly pack
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Number Of Channels | 12 Channels |
Model Name/Number | Contec 12 C |
Brand | Contec |
Input Way | Floating and defibrillation protection |
Digital Display | Yes |
Digital Filtering | Yes |
Operating Mode | Automatic |
Ecg Lead Annotation | Yes |
Lead | 12 leads |
Ac Filter | 50/60HZ |
Machine Size | 334 (L) x 320 (W) x 85 (H) mm |
Machine Net Weight | 2.25 Kg |
Frequency response | 0.05Hz~150Hz (-3 dB~0.4 dB) |
EMG interference filter | 35 Hz (-3dB) |
Sampling Rate | 1000HZ |
Recording Way | Thermal printing system |
Recording papers | 210mm (W) x 20 m (L) |
Features:
CONTEC 12 C ECG MACHINE
- PC interface software via RS232 interface/USB/Ethernet
- Basic software: For data transfer and print
- Advance software: For cardiac analysis
- AC/DC Operated with Rechargeable Lithium Battery
- Display 3/6/12 leads ECG waveform and can remark the lead sign, sensitivity paper speed and filter state
- Data interpretation
- Storage capacity upto 1000 patient's data, more convenient for data review & statistics
- Mode of printing : Automatic/Manual Printing Modes
- Rhythm row 12, row 10, row 8, row 6 etc with multiple formats
- Measurement parameter : HR, P-R interval P Duration, QRS Duration, Q Interval, Q-Tc, P Axis, QRS Axis, T Axis, R (V5), S(V1), R(V5) + S(V1)
- Product safety type : Class I CF applied part, with defibrillation and pacing protection circuit in it
- Enduring polarization voltage : ±500mV
- Noise level : ≤15μVp-p
- Patient leak current: ≤10μA
- Time Constant: Time ≥3.2s
- CMRR: ≤60 dB, ≤100 dB (add filter)
- Paper Auto record : 25mm/s, 50mm/s, error ±5% (Record setup according to auto record format and modem automatically measuring and analyzing)
- Paper manual record: 5mm/s, 6.25mm/s,10mm/s 12.5mm/s, 25mm/s,50mm/s, error ±5%
- Paper Rhythm record : 25mm/s, 50mm/s, error ±5% (Record setup according to auto record format and modem automatically measuring and analyzing)
Printing Modes:
- 12*1
- 6*2+1
- 6*2
- Auto 4*3
Additional Information:
- Item Code: EC12
- Production Capacity: Any
- Delivery Time: one week