Our Products
- Kirloskar 320 HD KVA Radiator Cooled Generators
- Kirloskar 625 HD kVA Radiator Cooled Generators
- Kirloskar 900 HD KVA Radiator Cooled Diesel Generator
- Kirloskar 380 HD KVA Radiator Cooled Generators
- Kirloskar 600 HD KVA Radiator Cooled Generators
- Kirloskar 1010 HD KVA Radiator Cooled Diesel Generator
- Kirloskar 400 HD KVA Radiator Cooled Generators
- Kirloskar 750 HD KVA Radiator Cooled Diesel Generator
- Kirloskar 500 HD KVA Radiator Cooled Generators
Kirloskar DV Series Genset 320-1010 KVA
Power (kVA) | 320 kVA |
Genset Brand | Kirloskar |
Model Number | KG1-320WS |
Phase | 3 Phase |
Fuel Consumption (at 100% Load) | 69 L/hr |
Fuel Tank Capacity | 850 L |
Frequency | 50 Hz |
Voltage | 415 V |
Governing Class | G3 |
Noise Level | Less than 75 dBA |
Weight | 5910 Kg (Dry) |
Dimensions | 5180x2000x2408 mm (LxWxH) |
Electrical Battery Starting Voltage | 24 V DC |
Engine Model | DV8TA G1 |
Rated Output | 294 kW, 400 HP |
Number of Cylinder | 8 |
Cubic Capacity | 15.92 L |
Bore x Stroke | 130 x 150 mm |
Rated Speed | 1500 RPM |
Aspiration | TA |
Lube Oil Change Period | 500 hrs. |
Lube Oil Sump Capacity | 44 Ltrs. |
Coolant Capacity with Radiator | 105 L |
Insulation Class | Class H |
Ingression Protection | IP 23 |
Time Permitted to Build Up Rated Voltage | <5 sec provided engine reach the rated speed |
Short Circuit Withstand Time | 3 Times rated Current for 3 sec |
Overload Withstand Capacity | 10% overload for one hour once in 12 hours |
Fuel Consumption (at 75% Load) | 52.5 ltrs/hr |
Power Factor | 0.8 lagging |
AREP | Yes |
Winding Pitch | 2/3 |
Voltage Regulation | +/-1 % |
Prime rating and Stand-by rating
Prime power’ is designed for Unlimited hours, as compared to 'Emergency stand-by' designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Genset rang to meet their requirement. KOEL offers Prime power as a standard offer.
Engine capacity does matter
Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance.
Higher engine capacity also enables the Genset to respond quickly & positively to sudden load addions.
Canopy
- Ease of Access and Serviceability
- Aesthetically designed, weather and sound resistant enclosure
- Insulation conforms to UL94-HF1 class for flammability
Controller
- Microprocessor based
- Graphical LCD display
- Best in class monitoring and diagnostic capability
- Integrable with AMF, synchronization & communication configurations
Engine
- O2E Series: Low emission, high efficiency engines
- Compact, Robust and Rugged Design
- 500 hours lube-oil change period
- Integral set - mounted radiator system, designed & tested for 50 Deg C ambient temperature
Alternator
- Best In Class Efficiency
- Special Windings to Reduce Harmonics
- Vacuum Pressure Impregnation and epoxy gel coating on the winding
*Terms & Condition:
- "Actual product may vary. Accessories shown may or may not be available in the final offer"
- CPCB II Compliant
View Complete Details
Power | 625 KVA |
Brand | Kirloskar |
Model | KG1-625WS |
Fuel Consumption (at 100% Load) | 130.5 L/hr. |
Fuel Tank Capacity | 990 L |
Frequency | 50 Hz |
Voltage | 415 V |
Dimensions | 6560x2000x2710 mm (LxWxH) |
Aspiration | TA |
Time Permitted to Build Up Rated Voltage | <5 sec provided engine reach the rated speed |
Lube Oil change period | 500 hrs. |
Electrical Battery starting voltage | 24 V DC |
Short Circuit Withstand Time | 3 Times rated Current for 10 sec |
Bore x Stroke | 130 x 150 mm |
Voltage Regulation | +/-1 % |
Rated Speed | 1500 RPM |
Ingression Protection | IP 23 |
Governing class | G3 |
Noise level | Less than 75 dBA |
Rated Output | 552 kW, 750 HP |
Insulation Class | Class H |
Power factor | 0.8 lagging |
Weight | 7800 Kg (Dry) |
Engine Model | DV12TA G2 |
Number of Cylinder | 12 |
Cubic Capacity | 23.88 Ltrs. |
Lube Oil Sump Capacity | 53 Ltrs. |
Coolant Capacity with Radiator | 145 L |
Overload Withstand Capacity | 10% overload for one hour once in 12 hours |
Fuel Consumption (at 75% Load) | 98.6 ltrs/hr |
AREP | Yes |
Winding Pitch | 2/3 |
Prime rating and Stand-by rating
Prime power’ is designed for Unlimited hours, as compared to 'Emergency stand-by' designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Genset rang to meet their requirement. KOEL offers Prime power as a standard offer.
Engine capacity does matter
Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance.
Higher engine capacity also enables the Genset to respond quickly & positively to sudden load addions.
Canopy
- Ease of Access and Serviceability
- Aesthetically designed, weather and sound resistant enclosure
- Insulation conforms to UL94-HF1 class for flammability
Controller
- Microprocessor based
- Graphical LCD display
- Best in class monitoring and diagnostic capability
- Integrable with AMF, synchronization & communication configurations
Engine
- O2E Series: Low emission, high efficiency engines
- Compact, Robust and Rugged Design
- 500 hours lube-oil change period
- Integral set - mounted radiator system, designed & tested for 50 Deg C ambient temperature
Alternator
- Best In Class Efficiency
- Special Windings to Reduce Harmonics
- Vacuum Pressure Impregnation and epoxy gel coating on the winding
*Terms & Condition:
- "Actual product may vary. Accessories shown may or may not be available in the final offer"
- CPCB II Compliant
View Complete Details
Power (kVA) | 900 kVA |
Genset Brand | Kirloskar |
Model Number | KG1-900WS |
Phase | 3 Phase |
Fuel Consumption (at 100% Load) | 197 ltrs/hr |
Fuel Tank Capacity | 990 ltrs |
Fuel Consumption (at 75% Load) | 163 ltrs/hr |
Lube Oil Consumption | 212 g/hr |
Lube Oil Change Period | 500 hrs |
Voltage | 415 V, 50Hz |
Power Factor | 0.8 lagging |
Rated Speed | 1500 rpm |
Method of Starting | Electric (24 V DC) |
Min Time to Start Engine to Rated RPM | 20 sec |
Power Panels | Optional |
MCCB Rating | 1600 A |
Noise Level (1 Mtr) | Less Than or equal to 75 dBA @ 1Mtr (Genset with Canopy) |
Thermal Efficiency (at 100% load) | 41% |
Mechanical Efficiency (at 100% load) | 95.1% |
Overall Dimensions (LxWxH) | 8000 x 2300 x 2713 mm |
Weight (Dry) | 13600 kg with canopy |
Quantity of Coolant (Engine) | 65 ltrs |
Quantity of Coolant (Radiator) | 95 ltrs |
Total Quantity of Coolant (Including Piping) | 180 ltrs |
Cooling / Ventilation Air Flow | 1425 m3/min |
Combustion Air Inlet Flow | 60.6 m3/min |
Total Fresh Air Required | 1485.6 m3/min |
Coolant Temperature | 104 Deg C (Maximum) |
AREP | Yes |
Winding Pitch | 2/3 |
Voltage Regulation | +/- 0.5% |
Insulation Class | H |
Low Running Costs:
- KOEL Genset’s Fuel efficiency is optimized for the most common usage band of 50-75% loading. Best-in-class fuel economy helps you reduce running costs.
Quick Response to Step Load:
- KOEL Gensets offer class-leading response to jerk loads/step-loads. This become especially important for starting large motors and operating special purpose machines.
Genset Control at Your Fingertips:
- Remote monitoring system in KOEL Green Gensets brings performance data, service reminders and alerts right on your desktop. Live information & historical data at your Fingertips.
7 Days Assured Delivery:
- 7 days delivery assurance is backed by KOEL’s globally-awarded supply chain. This means availability of Genset just when you need it & without blocking your money for long.
One Stop Solution:
- KOEL Green team assists you - from Genset selection to synchronization, from exhaust piping to commissioning. Leverage decades of industry experience for your requirement.
Monitoring Features
- Phase Voltages & Currents, Frequency, Reverse power, Genset kVA, KW, KVAr, KWH, Power Factor, Canopy Temperature
- Lube oil Pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel Level, Auto / Manual Stop
- Battery Charging Status
- AMF feature
Optional Features
- Modbus communication, Synchronization, Remote Monitoring
Diagnostic Features
- Battery charging failure, Over/Under speed, Over Current, Over/Under Voltage, Over KW, Phase Seq., Phase missing, Mains Under voltage, Earth Fault trip, Fuel usage Alarm
- Low lube oil Pressure, High Engine Temperature, Low/High battery voltage, Low Fuel Level, Over Crank protection, Routine maintenance indicator, Genset Test Facility, Mains Frequency
*Terms & Condition:
- "Actual product may vary. Accessories shown may or may not be available in the final offer"
- CPCB II Compliant
View Complete Details
Power | 380 KVA |
Brand | Kirloskar |
Model | KG1-380WS |
Fuel Consumption (at 100% Load) | 83.3 L/hr. |
Fuel Tank Capacity | 850 L |
Frequency | 50 Hz |
Ingression Protection | IP 23 |
Lube Oil Change Period | 500 hrs. |
Electrical Battery Starting Voltage | 24 V DC |
Bore x stroke | 130 x 150 mm |
Noise Level | Less than 75 dBA |
Rated Output | 346 kW, 470 HP |
Rated Speed | 1500 RPM |
Governing class | G3 |
Voltage Regulation | +/- 1% |
Power Factor | 0.8 lagging |
Voltage | 415 V |
Dimensions | 5446x2000x2408 mm (LxWxH) |
Aspiration | TA |
Weight | 6000 Kg (Dry) |
Engine Model | DV8TA G2 |
Number of Cylinder | 8 |
Cubic Capacity | 15.92 L |
Lube Oil Sump Capacity | 44 Ltrs. |
Coolant Capacity with Radiator | 115 L |
Insulation Class | Class H |
Time Permitted to Build Up Rated Voltage | <5 sec provided engine reach the rated speed |
Short Circuit Withstand Time | 3 Times rated Current for 10 sec |
Overload Withstand Capacity | 10% overload for one hour once in 12 hours |
Fuel Consumption (at 75% Load) | 61.2 ltrs/hr |
AREP | Yes |
Winding Pitch | 2/3 |
Prime rating and Stand-by rating
Prime power’ is designed for Unlimited hours, as compared to 'Emergency stand-by' designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Genset rang to meet their requirement. KOEL offers Prime power as a standard offer.
Engine capacity does matter
Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance.
Higher engine capacity also enables the Genset to respond quickly & positively to sudden load addions.
Canopy
- Ease of Access and Serviceability
- Aesthetically designed, weather and sound resistant enclosure
- Insulation conforms to UL94-HF1 class for flammability
Controller
- Microprocessor based
- Graphical LCD display
- Best in class monitoring and diagnostic capability
- Integrable with AMF, synchronization & communication configurations
Engine
- O2E Series: Low emission, high efficiency engines
- Compact, Robust and Rugged Design
- 500 hours lube-oil change period
- Integral set - mounted radiator system, designed & tested for 50 Deg C ambient temperature
Alternator
- Best In Class Efficiency
- Special Windings to Reduce Harmonics
- Vacuum Pressure Impregnation and epoxy gel coating on the winding
*Terms & Condition:
- "Actual product may vary. Accessories shown may or may not be available in the final offer"
- CPCB II Compliant
View Complete Details
Power | 600 KVA |
Genset Brand | Kirloskar |
Model Number | KG1-600WS |
Phase | 3 Phase |
Fuel Consumption (at 100% Load) | 125.9 L/hr. |
Fuel Tank Capacity | 990 L |
Frequency | 50 Hz |
Power Factor | 0.8 lagging |
Voltage | 415 V |
Governing Class | G3 |
Noise Level | Less than 75 dBA |
Weight | 7700 Kg (Dry) |
Dimension | 6560x2000x2710 mm (LxWxH) |
Electrical Battery Starting Voltage | 24 V DC |
Engine Model | DV12TA G1 |
Rated Output | 532 kW, 723 HP |
Number of Cylinder | 12 |
Cubic Capacity | 23.88 L |
Bore x Stroke | 130 x 150 mm |
Rated Speed | 1500 RPM |
Aspiration | TA |
Lube Oil Change Period | 500 hrs. |
Lube Oil Sump Capacity | 53 Ltrs. |
Coolant Capacity with Radiator | 145 L |
Insulation Class | Class H |
Ingression Protection | IP 23 |
Time Permitted to Build Up Rated Voltage | <5 sec provided engine reach the rated speed |
Short Circuit Withstand Time | 3 Times rated Current for 10 sec |
Overload Withstand Capacity | 10% overload for one hour once in 12 hours |
Fuel Consumption (at 75% Load) | 94.2 ltrs/hr |
AREP | Yes |
Winding Pitch | 2/3 |
Voltage Regulation | +/-1 % |
Prime rating and Stand-by rating
Prime power’ is designed for Unlimited hours, as compared to 'Emergency stand-by' designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Genset rang to meet their requirement. KOEL offers Prime power as a standard offer.
Engine capacity does matter
Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance.
Higher engine capacity also enables the Genset to respond quickly & positively to sudden load addions.
Canopy
- Ease of Access and Serviceability
- Aesthetically designed, weather and sound resistant enclosure
- Insulation conforms to UL94-HF1 class for flammability
Controller
- Microprocessor based
- Graphical LCD display
- Best in class monitoring and diagnostic capability
- Integrable with AMF, synchronization & communication configurations
Engine
- O2E Series: Low emission, high efficiency engines
- Compact, Robust and Rugged Design
- 500 hours lube-oil change period
- Integral set - mounted radiator system, designed & tested for 50 Deg C ambient temperature
Alternator
- Best In Class Efficiency
- Special Windings to Reduce Harmonics
- Vacuum Pressure Impregnation and epoxy gel coating on the winding
*Terms & Condition:
- "Actual product may vary. Accessories shown may or may not be available in the final offer"
- CPCB II Compliant
View Complete Details
Power (kVA) | 1010 kVA |
Genset Brand | Kirloskar |
Model Number | KG1-1010WS |
Phase | 3 Phase |
Fuel Consumption (at 100% Load) | 199 ltrs/hr |
Fuel Tank Capacity | 990 ltrs |
Fuel Consumption (at 75% Load) | 155 ltrs/hr |
Lube Oil Consumption | 226 g/hr |
Lube Oil Change Period | 500 hrs |
Voltage | 415 V, 50Hz |
Power Factor | 0.8 lagging |
Rated Speed | 1500 rpm |
Method of Starting | Electric (24 V DC) |
Min Time to Start Engine to Rated RPM | 20 sec |
Power Panels | Optional |
MCCB Rating | 1600 A |
Thermal Efficiency (at 100% load) | 41% |
Mechanical Efficiency (at 100% load) | 95.1% |
Overall Dimensions (LxWxH) | 7800 x 2300 x 2713 mm |
Weight (Dry) | 13200 kg with canopy |
Quantity of Coolant (Engine) | 65 ltrs |
Quantity of Coolant (Radiator) | 95 ltrs |
Total Quantity of Coolant (Including Piping) | 180 ltrs |
Cooling / Ventilation Air Flow | 1425 m3/min |
Combustion Air Inlet Flow | 60.6 m3/min |
Total Fresh Air Required | 1485.6 m3/min |
Coolant Temperature | 104 Deg C (Maximum) |
AREP | Yes |
Winding Pitch | 2/3 |
Voltage Regulation | +/- 0.5% |
Insulation Class | H |
Low Running Costs:
- KOEL Genset’s Fuel efficiency is optimized for the most common usage band of 50-75% loading. Best-in-class fuel economy helps you reduce running costs.
Quick Response to Step Load:
- KOEL Gensets offer class-leading response to jerk loads/step-loads. This become especially important for starting large motors and operating special purpose machines.
Genset Control at Your Fingertips:
- Remote monitoring system in KOEL Green Gensets brings performance data, service reminders and alerts right on your desktop. Live information & historical data at your Fingertips.
7 Days Assured Delivery:
- 7 days delivery assurance is backed by KOEL’s globally-awarded supply chain. This means availability of Genset just when you need it & without blocking your money for long.
One Stop Solution:
- KOEL Green team assists you - from Genset selection to synchronization, from exhaust piping to commissioning. Leverage decades of industry experience for your requirement.
Monitoring Features
- Phase Voltages & Currents, Frequency, Reverse power, Genset kVA, KW, KVAr, KWH, Power Factor, Canopy Temperature
- Lube oil Pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel Level, Auto / Manual Stop
- Battery Charging Status
- AMF feature
Optional Features
- Modbus communication, Synchronization, Remote Monitoring
Diagnostic Features
- Battery charging failure, Over/Under speed, Over Current, Over/Under Voltage, Over KW, Phase Seq., Phase missing, Mains Under voltage, Earth Fault trip, Fuel usage Alarm
- Low lube oil Pressure, High Engine Temperature, Low/High battery voltage, Low Fuel Level, Over Crank protection, Routine maintenance indicator, Genset Test Facility, Mains Frequency
*Terms & Condition:
- "Actual product may vary. Accessories shown may or may not be available in the final offer"
- CPCB II Compliant
View Complete Details
Power (kVA) | 400 kVA |
Genset Brand | Kirloskar |
Model Number | KG1-400WS |
Phase | 3 Phase |
Fuel Consumption (at 100% Load) | 86.9 L/hr. |
Fuel Tank Capacity | 850 L |
Frequency | 50 Hz |
Power Factor | 0.8 lagging |
Voltage | 415 V |
Governing Class | G3 |
Noise Level | Less than 75 dBA |
Weight | 6050 Kg (Dry) |
Dimensions | 5650x2000x2408 mm (LxWxH) |
Electrical Battery Starting Voltage | 24 V DC |
Engine Model | DV8TA G3 |
Rated Output | 360 kW, 490 HP |
Number of Cylinder | 8 |
Cubic Capacity | 15.92 L |
Bore x Stroke | 130 x 150 mm |
Rated Speed | 1500 RPM |
Aspiration | TA |
Lube Oil Change Period | 500 hrs. |
Lube Oil Sump Capacity | 44 Ltrs. |
Coolant Capacity with Radiator | 115 L |
Insulation Class | Class H |
Ingression Protection | IP 23 |
Time Permitted to Build Up Rated Voltage | <5 sec provided engine reach the rated speed |
Short Circuit Withstand Time | 3 Times rated Current for 10 sec |
Overload Withstand Capacity | 10% overload for one hour once in 12 hours |
Fuel Consumption (at 75% Load) | 65.1 ltrs/hr |
AREP | Yes |
Winding Pitch | 2/3 |
Voltage Regulation | +/-1 % |
Prime rating and Stand-by rating
Prime power’ is designed for Unlimited hours, as compared to 'Emergency stand-by' designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Genset rang to meet their requirement. KOEL offers Prime power as a standard offer.
Engine capacity does matter
Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance.
Higher engine capacity also enables the Genset to respond quickly & positively to sudden load addions.
Canopy
- Ease of Access and Serviceability
- Aesthetically designed, weather and sound resistant enclosure
- Insulation conforms to UL94-HF1 class for flammability
Controller
- Microprocessor based
- Graphical LCD display
- Best in class monitoring and diagnostic capability
- Integrable with AMF, synchronization & communication configurations
Engine
- O2E Series: Low emission, high efficiency engines
- Compact, Robust and Rugged Design
- 500 hours lube-oil change period
- Integral set - mounted radiator system, designed & tested for 50 Deg C ambient temperature
Alternator
- Best In Class Efficiency
- Special Windings to Reduce Harmonics
- Vacuum Pressure Impregnation and epoxy gel coating on the winding
*Terms & Condition:
- "Actual product may vary. Accessories shown may or may not be available in the final offer"
- CPCB II Compliant
View Complete Details
Power (kVA) | 750 kVA |
Genset Brand | Kirloskar |
Model Number | KG1-750WS |
Fuel Consumption (at 100% Load) | 154 ltrs/hr |
Phase | 3 Phase |
Fuel Tank Capacity | 990 ltrs |
Frequency | 50 Hz |
Fuel Consumption (at 75% Load) | 126.4 ltrs/hr |
Lube Oil Consumption | 165 g/hr |
Lube Oil Change Period | 500 hrs |
Voltage | 415 V, 50Hz |
Power Factor | 0.8 lagging |
Rated Speed | 1500 rpm |
Method of Starting | Electric (24 V DC) |
Min Time to Start Engine to Rated RPM | 20 sec |
Power Panels | Optional |
MCCB Rating | 1200 A |
Noise Level (1 Mtr) | Less Than or equal to 75 dBA @ 1Mtr (Genset with Canopy) |
Thermal Efficiency (at 100% load) | 41% |
Mechanical Efficiency (at 100% load) | 92.6% |
Overall Dimensions (LxWxH) | 6800 x 2300 x 2713 mm |
Weight (Dry) | 8300 kg with canopy |
Quantity of Coolant (Engine) | 44 ltrs |
Quantity of Coolant (Radiator) | 118 ltrs |
Total Quantity of Coolant (Including Piping) | 175 ltrs |
Cooling / Ventilation Air Flow | 1300 m3/min |
Combustion Air Inlet Flow | 50 m3/min |
Total Fresh Air Required | 1344 m3/min |
Coolant Temperature | 104 Deg C (Maximum) |
AREP | Yes |
Winding Pitch | 2/3 |
Voltage Regulation | +/- 0.5% |
Insulation Class | H |
Low Running Costs:
- KOEL Genset’s Fuel efficiency is optimized for the most common usage band of 50-75% loading. Best-in-class fuel economy helps you reduce running costs.
Quick Response to Step Load:
- KOEL Gensets offer class-leading response to jerk loads/step-loads. This become especially important for starting large motors and operating special purpose machines.
Genset Control at Your Fingertips:
- Remote monitoring system in KOEL Green Gensets brings performance data, service reminders and alerts right on your desktop. Live information & historical data at your Fingertips.
7 Days Assured Delivery:
- 7 days delivery assurance is backed by KOEL’s globally-awarded supply chain. This means availability of Genset just when you need it & without blocking your money for long.
One Stop Solution:
- KOEL Green team assists you - from Genset selection to synchronization, from exhaust piping to commissioning. Leverage decades of industry experience for your requirement.
Monitoring Features
- Phase Voltages & Currents, Frequency, Reverse power, Genset kVA, KW, KVAr, KWH, Power Factor, Canopy Temperature
- Lube oil Pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel Level, Auto / Manual Stop
- Battery Charging Status
- AMF feature
Optional Features
- Modbus communication, Synchronization, Remote Monitoring
Diagnostic Features
- Battery charging failure, Over/Under speed, Over Current, Over/Under Voltage, Over KW, Phase Seq., Phase missing, Mains Under voltage, Earth Fault trip, Fuel usage Alarm
- Low lube oil Pressure, High Engine Temperature, Low/High battery voltage, Low Fuel Level, Over Crank protection, Routine maintenance indicator, Genset Test Facility, Mains Frequency
*Terms & Condition:
- "Actual product may vary. Accessories shown may or may not be available in the final offer"
- CPCB II Compliant
View Complete Details
Power (kVA) | 500 kVA |
Genset Brand | Kirloskar |
Model Number | KG1-500WS |
Phase | 3 Phase |
Fuel Consumption (at 100% Load) | 107.5 L/hr. |
Fuel Tank Capacity | 990 L |
Frequency | 50 Hz |
Power Factor | 0.8 lagging |
Voltage | 415 V |
Governing Class | G3 |
Noise Level | Less than 75 dBA |
Weight | 7200 Kg (Dry) |
Dimensions | 5650x2000x2558 mm (LxWxH) |
Electrical Battery Starting Voltage | 24 V DC |
Engine Model | DV10TA G1 |
Rated Output | 447 kW, 608 HP |
Number of Cylinder | 10 |
Cubic Capacity | 19.9 L |
Bore x Stroke | 130 x 150 mm |
Rated Speed | 1500 RPM |
Aspiration | TA |
Lube Oil Change Period | 500 hrs. |
Lube Oil Sump Capacity | 50 Ltrs. |
Coolant Capacity with Radiator | 120 L |
Insulation Class | Class H |
Ingression Protection | IP 23 |
Time Permitted to Build Up Rated Voltage | Less than 5 sec provided engine reach the rated speed |
Short Circuit Withstand Time | 3 Times rated Current for 10 sec |
Overload Withstand Capacity | 10% overload for one hour once in 12 hours |
Fuel Consumption (at 75% Load) | 81.9 ltrs/hr |
AREP | Yes |
Winding Pitch | 2/3 |
Voltage Regulation | +/-1 % |
Prime rating and Stand-by rating
Prime power’ is designed for Unlimited hours, as compared to 'Emergency stand-by' designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Genset rang to meet their requirement. KOEL offers Prime power as a standard offer.
Engine capacity does matter
Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance.
Higher engine capacity also enables the Genset to respond quickly & positively to sudden load addions.
Canopy
- Ease of Access and Serviceability
- Aesthetically designed, weather and sound resistant enclosure
- Insulation conforms to UL94-HF1 class for flammability
Controller
- Microprocessor based
- Graphical LCD display
- Best in class monitoring and diagnostic capability
- Integrable with AMF, synchronization & communication configurations
Engine
- O2E Series: Low emission, high efficiency engines
- Compact, Robust and Rugged Design
- 500 hours lube-oil change period
- Integral set - mounted radiator system, designed & tested for 50 Deg C ambient temperature
Alternator
- Best In Class Efficiency
- Special Windings to Reduce Harmonics
- Vacuum Pressure Impregnation and epoxy gel coating on the winding
*Terms & Condition:
- "Actual product may vary. Accessories shown may or may not be available in the final offer"
- CPCB II Compliant
View Complete Details
Explore more categories
- Developed and Managed by IndiaMART InterMESH Limited