Our Products
- Bio Chemistry Analyzer
- Portable Turbidity Meter
- TDS Conductivity Meter
- Fully Automatic Photo colorimeter
- Photo colorimeter (Auto Zero)
- Auto Turbidity Meter
- Digital Turbidity Nephelometer
- Automatic Urine Analyzer
- Digital Photo Fluorometer
- Ultrasonic Probe Sonicator
- Conductivity/TDS/Salinity/Temp. Meter Touch Screen
- Digital Conductivity Meter
- Turbidity Meter
- LBX 510 Digital Conductivity Meter (Inbuilt Stirrer)
- Blood Roller Mixer
- Photo colorimeter
- Differential Blood Cell Counter
- Automated Coagulation Analyzer
- Haemoglobin Meter
- Deluxe Conductivity Meter
- Colony Counters (3 digit LED)
- Rotary Blood Mixer AC
- Portable Haemoglobin Meter
- pH/Conductivity/TDS/Salinity/ Temp. Meter
- Rotating Mixer Adjustable Rotating Speed
- Colony Counters 6 Digit LCD
- LBX 513 Conductivity/TDS/Salinity/Temp. Meter
- LBX 511 Digital TDS Meter (Inbuilt Stirrer)
- Portable TDS Meter
- Digital TDS Meter (Auto Ranging)
- Portable Dissolved Oxygen Meter
- Colony Counters
- Fully Automatic Hematology Analyzer (Double Chamber))
- Portable PH Meter
- Portable Conductivity Meter
Analytical & Testing Equipments
| Automation Grade | Automatic |
| Automation | Semi Automatic |
| Brand | LABIX |
| Assays | Clinical Chemistry |
| Model Name | Bio Chemistry Analyzer |
| Model Number | LBX-723 |
| Power Supply | 100-240v AC |
| Storage | 1000 Test Results |
| Usage/Application | Hospital and Clinical Laboratories |
Technical Specifications:
|
Test Method |
End Point with standard/factor Two Point Kinetics (Fixed Time) Multipoint Kinetics Multi standard up to 8 standards Biochromic, Dual Wavelength |
|
Absorbance |
Optical System Principle: Photometric Analysis with Interference Filter Absorbance Range: 0.0000-3.0000 (Linearity: ±1%, Repeatability: 0.001, Resolution: 0.0001) Spectral Range Selection: Automatic Via Filter Wheel Wavelengths: 340, 405, 505, 546, 578, 630 nm +2 Free Positions, ± 2 CML Precision Light Source: 6 V 10 W Long Life tungsten Halogen Lamp Detector: Photodiode |
|
Operating Conditions |
* Temperature: 10°C-37°C * Relative Humidity: <85% |
|
Quality Control |
Lew-Jennings Chart Using Westgard's Rule Auto Drawing of QC figures |
|
Test Parameter, |
Test Parameters: Up to 300 |
|
Storage & Cpu |
1,000 test results with editable patient information Storage of Quality Control And standard results |
|
Display & Input System |
4.3 inch color touch screen |
|
Printer |
Inbuilt Thermal Printer (57mm) |
View Complete Details
| Brand | LABIX |
| Usage/Application | Laboratory Research Grade |
| Accuracy | 3% of reading |
| Resolution | 0.001 NTU |
| Weight | 500g |
| Display | TFT screen |
| Dimension | 210x105x65 |
| Measuring range (NTU) | 0-10,0-100,0-1000,0-4000 NTUI |
| Model number | LBX-523 |
with Range -0 to 1100 NTU/FNU, Resolution -0.01, 0.1, 1, Accuracy- ± 2% of reading (0 to 500 NTU), ± 3% of reading (501 to 1100 NTU), Calibration Points- 2 to 5 points, Light Source - Infrared-emitting diode (850 nm wavelength), Detector - Silicon photodiode, Stray Light- < 0.02 NTU, Memory- 100 data sets, Communication - USB interface, Operating Temperature - 0 to 50° C (32 to 122° F), Storage Temperature - 0 to 60° C (32 to 140° F), Relative Humidity - < 80% (non-condensing), Display – LCD
View Complete Details
| Conductivity Range | 1000 mS/cm |
| Accuracy | +-0.3% FS |
| Weight | 2Kg |
| Power | 220-240V AC |
| Warranty | 1 Year |
| TDS | 200 ppm -1000 ppm |
| Brand | LABIX |
| Model number | LBX-516 |
Technical Specifications
|
Range |
COND. 200 µs to 1000 ms in 5 ranges. TDS-200ppm to 1000 ppt in 5 ranges. |
|
Accuracy |
±0.3% F.S. 200 Micro Mhos/cm to 200m/ |
|
Mhos/cm. |
±1% FS. In last range 1000m Mhos/cm |
|
Resolution Measuring |
Mhos : 0.1 Micro mhos/cm |
|
Frequency |
1000 HZ |
|
Temperature |
|
|
Compensation |
0 to 50° C |
|
Cell Constant |
0.4 to 1.5 adjustable |
|
Function Selector |
CHECK/TDS./ COND./CELL CONST. |
|
CAL Function |
For full scale adj. (at back panel) Select at CHECK Position |
|
Digital Display |
3½digit LED display. |
|
Power Supply |
220V ± 10% HZ AC |
|
Dimension |
275x175 x75 mm(LXBXH) |
|
Weight |
2 Kg. |
|
Accessories |
TDS/COND. Cell (Dip Type), Operation Manual, Dust Cover |
View Complete Details
| Mobility | Benchtop |
| Std Glass Filters | 9 filters |
| Display | LCD |
| Model No / Item Code | LBX-518 |
| Accuracy | +-0.01 OD |
| Detector | Silicon Photodiode |
| Filter Range | 400-680 nm |
| Light Source | Highly Accurate Laser Source |
| Power | 220-240V AC |
| Usage/ Application | Laboratory |
| Brand | LABIX |
Technical Specifications
|
Range |
400-700nm |
|
Display |
Dual Digital Display |
|
Filters |
Built In 9 Digital Filters > 30000 Hours Life |
|
Filters Wavelength |
400nm, 430nm, 500nm, 520nm, 540nm, 580nm, 600nm, 620nm, 680nm |
|
Display Mode |
Absorbance & Wavelength |
|
Detector |
Silicon Photo Diode |
|
Zero Adjustment |
Auto zero |
|
Accuracy |
± 0.01 O.D. |
|
Stability |
±0.02 O.D. Per Hour |
|
Light Source |
Highly Accurate Laser Source |
|
Amplifier |
Micro Controller Based |
|
Volume |
1 ml. Minimum |
|
Dimension |
210 x 160 x 80 mm (LxBxH) Approx. |
|
Weight |
1.5 Kgs. (Approx) |
|
Power |
230V ± 10% AC, 50Hz |
|
Battery Backup |
6V Ni-Cd Re-Chargeable Battery |
|
Accessories |
Set of Test Tube - 6 Nos. Dust Cover - 1 No. Operational manual |
View Complete Details
| Mobility | Benchtop |
| Std Glass Filters | 8 Filters |
| Display | 3 Display Digit |
| Model No / Item Code | LBX-519 |
| Accuracy | +-0.02 OD |
| Detector | Selenium Photocell/ Photodiode |
| Light Source | Tungsten lamp/ LED |
| Power | 220-240V Ac |
| Usage/ Application | Laboratory |
| Brand | LABIX |
Technical Specifications
|
Filters |
8 Filters |
|
Accuracy |
± 0.02 O.D. |
|
Reproducibility |
± 0.01 O.D. |
|
Stability |
± 0.02 O.D. Per Hour |
|
Light Source |
6.8V, 0.3 AMP Tungsten Lamp/LED |
|
Key Board |
1 Soft touch key |
|
Amplifier |
I.C. Based |
|
Detector |
Selenium Photocell/Photodiode |
|
Warm-up-Time |
5 Minutes |
|
Sample System Tubes |
10 mm dia matched glass test |
|
Power Source |
230v ±10% 50Hz AC. |
|
Accessories |
Glass Test Tubes-5 Nos, Instruments Cover Operating Manual, Spare Lamp ( Fitted Inside) |
View Complete Details
| Brand | LABIX |
| Usage/Application | Laboratory |
| Range | 1000 NTU |
| Accuracy | 3% of reading |
| Light Source | Tungsten filament lamp |
| Detector | Photocell/ Photodiode |
| Model number | LBX-525 |
Technical Specifications
|
Type |
Microprocessor based |
|
Readings |
up to 10- 1000 NTU/JTU in 5 ranges |
|
Range |
Range-0 to 10 , 0 to 100,0 to200, 0 to 400 & 0 to 1000 NTU/JTU |
|
Accuracy |
± 3% of full scale |
|
Test Tube System |
30 mm clear glass test tube |
|
Light Source |
6 V |
|
Lamp |
Tungsten |
|
Display |
4 digit red LED display |
|
Detector |
Photocell/ Photodiode |
|
Power |
Supply 230 V ± 10% AC, 50Hz with Built-in voltage. stabilizer |
View Complete Details
| Usage/Application | Laboratory |
| Voltage | 220-240 V AC |
| Power | 220-240V AC |
| Accuracy | +-2% FS +-Digit |
| Detector | Photocell/Photodiode |
| Dimension | 280x175x110 mm |
| Range | 0-200 NTU in 2 Ranges |
| Resolution | 0.1 NTU |
| Brand | LABIX |
| Model number | LBX-527 |
Technical Specifications
|
Product |
Digital Nephelometer |
|
Display |
3½ Digit LED |
|
Detector |
Photocell/Photodiode |
|
Range |
0 to 200 NTU in 2 ranges |
|
Resolution |
0.1 NTU |
|
Accuracy |
±2% FS±1 Digit |
|
Sample System |
60 x 25mm Clear Glass Test Tube |
|
Light Source |
LED |
|
Power |
230V±10%, 50Hz. AC |
|
Dimensions |
280 x 175 x 110 mm |
|
Accessories |
Test Tube Set, Operation Manual, Dust Cover |
View Complete Details
| Automation Grade | Automatic |
| Instrument Name | Urine Analyzer |
| Brand | LABIX |
| Model Name/Number | LBX-720 |
| Usage/Application | Laboratory |
| Parameters | PH |
| Automation | Manual |
| User Input | Keyboard |
| Display | Analog |
Salient Features
- High-Luminance and white LED, features in long life and good stability.
- Large LCD screen, high luminance, abundant contents display
- User-friendly interface
- Optional Unit: International unit, convention unit and symbol system.
- Three working mode: One Step/slow/fast testing mode, Suitable for different user group.
- Monitoring the whole test process, auto character and audible prompt.
- Be compatible with 8, 10 and 11-Parameter test strip.
- Standard Rs232 Interface and interface for data communication.
- Built-in thermal Printer.
View Complete Details
| Mobility | Benchtop |
| Model Name/Number | LBX-532 |
| Detector | Silicon Photodiode |
| Display range | 3 digit 7 segment LED |
| Weight | 4.5 Kg |
| Power | 220-240 V AC |
| Usage/ Application | Laboratory |
| Excitation Source | 12V, 50W Tungsten Halogen Lamp |
| Brand | LABIX |
Salient Features
- 3 Digit Seven Segment LED Display
- Covers Entire Visible Range
- Determines the concentration of Fluorophores & Quinine
View Complete Details
| Capacity | 200 ml |
| Usage/Application | Pharmaceuticals |
| Automation Grade | Automatic |
| Weight | 7kgs |
| Temperature | 100 DegreeC |
| Product Quality | Superior |
| Brand | LABIX |
| Model number | LBX-541 |
Technical Specifications
|
Rated Power |
250W |
|
Input Voltage |
110/220-240v |
|
Input Frequency |
50Hz-60Hz |
|
Output Power |
< 250w |
|
Frequency Tracking |
Automatic tracking |
|
Power And Amplitude Adjust |
0-100% |
|
Packing Size(cm) |
32 x 46 x 42cm |
|
Machine Weight(kg) |
7 |
|
Sonotrode Length |
120mm |
|
Sonotrode Diameter |
8mm |
|
Sonotrode Frequency |
20KHz |
|
Operation Panel Display |
Time setting working data |
|
Working Mode |
1s-99 hours with pause function continuous working |
|
Generator Protection |
Built-in circuit, Overloading. Over temperature, Antishort - circuit, Soft start |
|
Cable Length |
2M |
|
Environment Temp |
0-40°C |
|
Relative Humidity |
<=85% T=20°C |
|
Max Temp. Of Sonotrode |
100°C |
|
Max Pressure |
5Mpa |
|
Treatment Capacity Of Liquid |
<10L/H |
|
Breaker Type For Batch |
20ML-200ML |
|
Accessories |
Abs Soundproof Box, Stainless Steel Lifting Platform, 3 Fuse |
View Complete Details
Conductivity/TDS/Salinity/Temp. Meter Touch Screen
₹ 46,000/PieceGet Latest Price
Minimum Order Quantity: 01 Piece
| Usage/Application | Laboratory |
| Brand | LABIX |
| Warranty | 1 Year |
| Resolution | 0.01 PPM |
| Features | Touch Screen Conductivity/TDS/Salinity/Temp.Meter |
| Cell Constant | Adjustable |
| Display Type | Touch screen |
| Measurable Conductivity Range | 200mS |
| Number Of Ranges | 5 |
| Power | 220-240V AC |
| Type Of Temperature Compensation | Auto/Manual |
| Tds Range | 200 ppm |
| Model number | LBX-509 |
Salient Features
- 5 Inches Colored Touch Screen.
- Password Protected data login Facility.
- EC, TDS, Salinity & Temperature Measurements.
- Auto Temperature Compensation.
- Auto Ranging Facility.
- Programmable Ref. Temp & Temp. Coeff in EC mode.
- 1000 Samples Storage Facility.
- Printer Attachment Facility.
View Complete Details
| Material | Mild Steel |
| Display Type | LED |
| Accuracy | +-0.5 FS +-1 digit |
| Dimension | 270x202x80 mm |
| Weight | 1 Kg |
| Power | 220-240V AC |
| Warranty | 1 year |
| Brand | LABIX |
| Model number | LBX-514 |
| Temperature compensation | Manual 0-50 Degree C |
Technical Specifications
|
Display |
3½ Digit LED |
|
Measurement : |
Conductivity |
|
Cond. Ranges : |
Automatic 5 Ranges. |
|
Range Selection : |
Automatic in 5 Ranges |
|
Temp. Range : |
-5 to 110°C |
|
Accuracy |
Cond. : ±0.5% FS ± 1Digit Temp. ±0.1°C ± 1 Digit |
|
Temp. Compensation |
Auto 0 to 50°C (in Model LBX-515 ONLY) Manual 0 to 50°C in (LBX-514) |
|
Cell Constant : |
Adjustable on Digital Display |
|
Measuring Cell : |
Platinum DIP Type |
|
Cell Const measurement. |
Auto |
|
Power : |
230V ± 10% AC |
|
Dimensions |
270x202x80 mm (LxBxH) |
|
Weight |
0.8kg Approx. |
|
Accessories : |
Conductivity Cell, Operation Manual, Dust Cover, Cell Stand, Temperature Probe (With Model LBX-515) |
View Complete Details
| Usage/Application | Laboratory |
| Brand | LABIX |
| Range | 1000 NTU |
| Accuracy | 3% of reading |
| Light Source | Tungsten filament lamp |
| Detector | Photodiode |
| Display | LCD |
| Power Supply | 220-240V AC |
| Model number | LBX-524 |
Technical Specifications
|
Display |
16x2 Lines Alfa Numeric Display. |
|
Range |
Two Ranges 0 to 200.0 & 200 to 1000 JTU/NTU |
|
Accuracy |
±3% of full Scale Deflection in 0-1000 JTU/NTU |
|
Sample System |
30mm Clear Glass Cuvettes |
|
Light Source |
6.8 Volt, 0.3 Amp Tungsten Lamp. |
|
Detector |
Photo diode |
|
Memory |
In built memory to retain both range standard solution and last set value even after power loss |
|
Calibration |
With Formazine solution |
|
Power Supply |
230 V ± 10%, 50Hz.. |
|
Accessories |
Cuvettes 30m dia, Operation Manual, Dust Cover |
View Complete Details
LBX 510 Digital Conductivity Meter (Inbuilt Stirrer)
₹ 8,600/PieceGet Latest Price
Minimum Order Quantity: 01 Piece
| Conductivity Range | 1000 mS/cm |
| Cell Constant | Auto |
| Accuracy | +-0.5 % FS +- digit |
| Dimension | 270x202x80 mm |
| Weight | 1 Kg |
| Power | 220-240V AC |
| Warranty | 1 year |
| Brand | LABIX |
| Model number | LBX-510 |
Technical Specifications
|
Display |
3½ Digit LED |
|
Measurement |
Conductivity |
|
Cond. Ranges |
Automatic 5 Ranges 0-200µS. 0-2, 0-20, 0-200, 0-1000 mS |
|
Range Selection |
Automatic in 5 Ranges |
|
Temp. Range |
-5 to 110°C |
|
Accuracy |
COND. ±0.5% FS ±1Digit TEMP.±0.1°C ± 1Digit |
|
Temp.compensation |
Auto: 0 to 50 °C |
|
Stirrer |
Inbuilt Stirrer (with speed variable) |
|
Cell Constant |
Adjustable on Digital Display |
|
Measuring Cell |
Platinum DIP Type |
|
Cell Const. Measurement |
Auto |
|
Power |
230V± 10% AC |
|
Dimensions |
270x202x80 mm (LXBXH) |
|
Weight |
0.8 Kg approx. |
|
Accessories |
Conductivity Cell, Operation Manual, Dust Cover, Cell Stand, Magnetic Capsule |
View Complete Details
| Number of Tubes | 5 |
| Brand | LABIX |
| Roller Size | 230mm |
| Controls | Analog |
| No of rollers | 4 |
| Speed | 33 RPM |
| Model No | LBX-603 |
Salient Features
- Rocking and rolling action for complete Mixing
- Four roller design with small foot print
- Designed for continuous quiet operation
- Ambient temperature range +4°C to 60°C
View Complete Details
| Mobility | Benchtop |
| Std Glass Filters | 8 Filters |
| Display | 3 Display Digit |
| Model No / Item Code | LBX-520 |
| Accuracy | +-0.02 OD |
| Detector | Selenium Photocell/Photodiode |
| Light Source | Tungsten lamp/ LED |
| Power | 220-240V AC |
| Usage/ Application | Laboratory |
| Brand | LABIX |
Technical Specifications
|
Filters |
8 Filters |
|
Accuracy |
± 0.02 O.D. |
|
Reproducibility |
± 0.01 O.D. |
|
Stability |
±0.02 O.D. Per Hour |
|
Light Source |
6.8V, 0.3 AMP Tungsten Lamp/LED |
|
Key Board |
Potentiometer adjustment |
|
Amplifier |
I.C. Based |
|
Detector |
Selenium Photocell/Photodiode |
|
Warm-up-Time |
5 Minutes |
|
Sample System Tubes |
10 mm dia matched glass test |
|
Power Source |
230v ±10% 50Hz AC. x 12V Rechargeable Battery |
|
Accessories |
Glass Test Tubes-5 Nos, Instruments Cover Operating Manual, Spare Lamp ( Fitted Inside) |
|
Filters |
8 Filters |
|
Accuracy |
± 0.02 O.D. |
|
Reproducibility |
± 0.01 O.D. |
|
Stability |
±0.02 O.D. Per Hour |
|
Light Source |
6.8V, 0.3 AMP Tungsten Lamp/LED |
|
Key Board |
Potentiometer adjustment |
|
Amplifier |
I.C. Based |
|
Detector |
Selenium Photocell/Photodiode |
|
Warm-up-Time |
5 Minutes |
|
Sample System Tubes |
10 mm dia matched glass test |
|
Power Source |
230v ±10% 50Hz AC. x 12V Rechargeable Battery |
|
Accessories |
Glass Test Tubes-5 Nos, Instruments Cover Operating Manual, Spare Lamp ( Fitted Inside) |
View Complete Details
| Minimum Volume | 1 ml |
| Mobility | Benchtop |
| Std Glass Filters | 6 filters |
| Display | 3 Display Digit |
| Model No / Item Code | LBX-521 |
| Accuracy | +-0.02 OD |
| Light Source | Tungsten Lamp/LED |
| Data Storage | Retain last K factor |
| Power | 220-240V AC |
| Usage/ Application | Laboratory |
| Brand | LABIX |
Technical Specifications
|
pH Measurements |
|
|
Display |
3 Digit Red Led Display |
|
Display Modes |
% T, O.D. AND 3 Concentration Modes C1, C2, C3 |
|
Zero Adjustment |
Automatic (Without Knob Rotation) |
|
Accuracy |
± 0.02 O.D. |
|
Stability |
+0.02 O.D.Per Hour. |
|
Light Source |
6.8 Volt, 0.3 Amp Tungsten Lamp/LED |
|
Amplifier |
Micro Controller Based. |
|
Memory |
In built Memory to retain Last "K" Factor For Concentration Even After Power Loss. |
|
Sample Volume |
1 ml. Minimum |
|
Power Supply |
230V+10%, 50 Hz |
|
Accessories |
Glass Test Tubes-5 Nos, Instruments Cover Operating Manual, Spare Lamp ( Fitted Inside) |
View Complete Details
| Mobility | Benchtop |
| Std Glass Filters | 8 Filters |
| Model No / Item Code | LBX-522 |
| Accuracy | +-0.02 O.D |
| Detector | Selenium Photocell/Photodiode |
| Light Source | Tungsten Lamp/LED |
| Power | 220-240V AC |
| Usage/ Application | Laboratory |
| Brand | LABIX |
Technical Specifications
|
Filters |
8 Filters |
|
Accuracy |
± 0.02 O.D. |
|
Reproducibility |
± 0.01 O.D. |
|
Stability |
±0.02 O.D Per Hour |
|
Light Source |
6.8V, 0.3 AMP Tungsten Lamp/LED |
|
Key Board |
Potentiometer Adjustment |
|
Amplifier |
I.C.Based |
|
Detector |
Selenium Photocell/Photodiode |
|
Warm-up-Time |
5 Minute |
|
Sample System Tubes |
10 mm dia matched glass test |
|
Power Source |
230v ±10% 50Hz AC. |
|
Accessories |
Glass Test Tubes-5 Nos, Instruments Cover Operating Manual, Spare Lamp ( Fitted Inside) |
View Complete Details
| Automation Grade | Automatic |
| Automation | Fully Automatic |
| Brand | LABIX |
| Assays | Clinical Chemistry |
| Sterile/ Non Sterile | Sterile |
| Model Name | Bio Chemistry Analyzer |
| Model Number | LBX-722 |
| Reaction Cuvette | Disposable Cuvette |
Salient Features
- Highly Stable and accurate
- Absorbance Range upto 3,000
- Range Selection Automatic Via Filter Wheel
- Inbuilt Thermal Printer
- Up to 300 Test Parameters
- Storage of 2,00,000 test results with patient information
View Complete Details
| Usage/Application | Laboratory |
| Brand | LABIX |
| Model Name/Number | LBX-533 |
| Weight | 1.5 Kg |
| Portable | Yes |
| Cell Counting Keys | 16 Keys (8 cell keys and 3 function keys) |
Salient Features
- Facility to count 8 Types of Cells
- 16x2 Line Alphanumeric LCD Display
- Automatic percentage (%) calculation
- Individual cells counting facility
- In-built Stop Watch and Timer function
- Audible beep facility
View Complete Details
| Brand | LABIX |
| Usage/Application | Laboratory |
| Range | 1000 NTU |
| Accuracy | 3% of reading |
| Resolution | 1 NTU |
| Light Source | LED Lamp |
| Dimension | 280X175X110 mm |
| Power Supply | 220-240V AC |
| Model number | LBX-526 |
Technical Specifications
|
Product |
Digital Turbidity Meter |
|
Display |
3½ Digit LED |
|
Detector |
Photocell / Photodiode |
|
Range |
0 to 1000 NTU in 2 ranges |
|
Resolution |
1NTU |
|
Accuracy |
+3% FS ±1 digit |
|
Sample System |
60 x 25mm Clear Glass Test Tube |
|
Light Source |
LED |
|
Power |
230V±10%, 50Hz. AC |
|
Dimensions |
280 x 175 x 110 mm |
|
Accessories |
Test Tube Set, Operation Manual, Dust Cover |
View Complete Details
| Brand | LABIX |
| Model Name/Number | LBX-719 |
| Usage/Application | Laboratory |
| Storage | Yes |
| Automation Grade | Automatic |
| Automation | Semi Automatic |
Salient Features
- 5-Inch Touch Screen and Keyboard 4 Independent channel Parameters
- PT, APTT,TT, FIB, etc.
- Principle: Clotting ,, Option Method
- Micro Volumes
- Disposable Cuvette no Carry-over
- Precise Electronics pipette Languages: English, French, Spanish, Portuguese etc.
- Automatic Start at reagent addition
- Thermal Printer, auto & Manual Print
View Complete Details
| Automation | Automatic |
| Brand | LABIX |
| Instrument Type | Benchtop |
| Model Name/Number | LBX-528 |
| Display | 3 digit LED |
| Accuracy | +-0.02 O.D |
| Sample Volume | 1 ml |
Technical Specifications
|
Display |
3 Digit Red Led Display |
|
Display Modes |
% T, O.D. And 3 Concentration Modes C1,C2,C3 |
|
Zero Adjustment |
Automatic (without Knob Rotation) |
|
Accuracy |
± 0.02 O.D. |
|
Stability |
±0.02 O.D. Per Hour. |
|
Light Source |
6.8 Volt, 0.3 Amp Tungsten Lamp/led |
|
Amplifier |
Micro Controller Based |
|
Memory |
In Built Memory To Retain Last "k' Factor For Concentration Even After Power Loss. |
|
Sample Volume |
1 ml. Minimum |
|
Power Supply |
230v ±10%, 50hz. |
|
Accessories |
Glass Test Tubes(5 Nos),instruments Cover, Operating Manual, Spare Lamp ( Fitted Inside). |
View Complete Details
| Accuracy | +-0.5 FS +-1 digit |
| Dimension | 270x202x80 mm |
| Weight | 1Kg |
| Power | 220-240V AC |
| Warranty | 1 year |
| Brand | LABIX |
| Model Number | LBX-515 |
| Temperature Compensation | Auto 0-50 DegreeC |
Technical Specifications
|
Display |
3½ Digit LED |
|
Measurement : |
Conductivity |
|
Cond. Ranges : |
Automatic 5 Ranges. |
|
Range Selection : |
Automatic in 5 Ranges |
|
Temp. Range : |
-5 to 110°C |
|
Accuracy |
Cond. : ±0.5% FS ± 1Digit Temp. ±0.1°C ± 1 Digit |
|
Temp. Compensation |
Auto 0 to 50°C (in Model LBX-515 ONLY) Manual 0 to 50°C in (LBX-514) |
|
Cell Constant : |
Adjustable on Digital Display |
|
Measuring Cell : |
Platinum DIP Type |
|
Cell Const measurement. |
Auto |
|
Power : |
230V ± 10% AC |
|
Dimensions |
270x202x80 mm (LxBxH) |
|
Weight |
0.8kg Approx. |
|
Accessories : |
Conductivity Cell, Operation Manual, Dust Cover, Cell Stand, Temperature Probe (With Model LBX-515) |
View Complete Details
| Model Name/Number | LBX-539 |
| Display Type | 3 digit LED |
| Usage/Application | Laboratory |
| Count Capacity | 999 |
| Size | 255x220x100 mm |
| Weight | 3Kg |
| Voltage Rating | 220-240 AC |
| Memory Back Up | 40 memory backup |
| Brand | LABIX |
Salient Features
- Count Correction Facility
- Result-Count Storage
- Audible Confirmation of Each Count
- Uniform Glare Free Illumination
- Wolffhugel Glass Grid with Focussing Facility
- LED Based illumination
- Auto Marker Pen
View Complete Details
Rotary Blood Mixer AC
₹ 16,000/PieceGet Latest Price
| Brand | LABIX |
| Speed | 30 RPM |
| Slope Angle | 45 Degree |
| Weight | 2Kg |
| Model number | LBX-602 |
Salient Features
- AC Synchronous motor for noiseless operation.
- Suitable for a variety of centrifugal tube 1.5-50ml.
- Circular rotating action gives gentle and effective mixing.
- Fix speed of 30 RPM with an accuracy of ±2 RPM.
- Continuous/infinite mode of operation. Fix plate angle of 45 Degree.
- Easy to operate, long running, stable and low noise.
- Maximum operational weight capacity of 1.5 kgs.
- Easy to remove and install disk plates for replacement and cleaning.
View Complete Details
| Brand | LABIX |
| Instrument Type | Portable |
| Model Name/Number | LBX-529 |
| Storage | 1000 test results |
| Measuring Range | 5-25 gm/dl |
| Portable | Yes |
Technical Specifications
|
Testing Strip |
Ten |
|
Measuring Range |
5-25 gm/dl |
|
Memory |
1000 Test Results |
|
Calibration |
Auto |
|
Accessories |
HB Meter, Canister of Test Strips, Code Chip Control Chip, Capillary Transfer Tube/Dropper Lancing Device, Sterile Lancets, AAA Batteries |
View Complete Details
pH/Conductivity/TDS/Salinity/ Temp. Meter
₹ 24,000/PieceGet Latest Price
Minimum Order Quantity: 01 Piece
| Conductivity Range | 1000 mS/cm |
| Display Type | LCD |
| Accuracy | +-0.5% of range |
| Features | pH/Conductivity/TDS/Salinity/Temp. Meter |
| Power | 220-240V AC |
| Warranty | 1 year |
| TDS | 0.0-1000 ppt |
| Data Storage | 1000 samples |
| Brand | LABIX |
| Model number | LBX-512 |
Technical Specifications
|
pH |
|
|
Range |
0 to 14 pH |
|
Resolution |
0.01 pH |
|
Accuracy |
±0.01 pH ± 1 Digit |
|
Slope Adjustment |
±1 digit 80% to 120% by default 100% |
|
Temp. Compensation |
0 to 100°C Auto with temp probe/Manual with keys |
|
Auto Buffer Recognition |
4.00 pH., 7.00 pH., 9.20 pH |
|
Calibration |
5 point (Programmable) |
|
Conductivity-TDS-SAL |
|
|
Range |
Conductivity 0.00 µ/km to 1000 mS Auto ranging |
|
TDS |
0.0 ppm to 1000 ppt Auto ranging |
|
SAL |
0.0 ppt to 50 ppt Auto ranging |
|
Resolution |
Conductivity 0.01 uS on the lowest range |
|
TDS |
0.1 ppm |
|
SAL |
0.2 ppt |
|
Accuracy |
±0.5% of range ±1 digit |
|
Measuring Cell |
Platinum DIP type |
|
Temp. Compensation |
0 to 100°C Automatic with temp probe |
|
Temperature |
|
|
Range |
-50.0 °C to 200°C |
|
Resolution |
0.1°C |
|
Accuracy |
± 0.1% of range ±1 digit |
|
Calibration |
two point manual |
|
Sensors |
PT 100 probe |
|
Data Entry |
By six soft touch keys with audible sound |
|
Storage |
1000 samples |
|
Interface |
USB |
|
Print Format |
All Data & Date wise (Programmable) |
|
Error Indication |
pH ERROR. ORP ERROR. CAL ERROR & T-ERROR |
View Complete Details
Rotating Mixer Adjustable Rotating Speed
₹ 36,000/PieceGet Latest Price
| Speed | 1-99 RPM |
| Oscillation Method | Circle |
| Brand | LABIX |
| Model Number | LBX-601 |
| Weight | 3.5 Kgs |
Salient Features
- 10 different self-contained programs (rotation and 360 Degree
- rotation and vibration).
- Adjustable time and speed at any angle.
- Digital display for better understand.
- Additional self-programming programs.
View Complete Details
| Model Name/Number | LBX-538 |
| Display Type | 6 Digit LED |
| Usage/Application | Laboratory |
| Count Capacity | 999999 |
| Size | 255x220x100 mm |
| Number Of Digits | 6 |
| Memory Back Up | 125 result |
| Memory Retention | Yes |
| Brand | LABIX |
| Rated Supply Voltage | 220-240V AC |
Salient Features
- Count Correction Facility
- Result-Count Storage
- Audible Confirmation of Each Count
- Auto Marker Pen
- Uniform Glare Free Illumination
- Wolffhugel Glass Grid with Focussing Facility
- LED Based Illumination
View Complete Details
LBX 513 Conductivity/TDS/Salinity/Temp. Meter
₹ 18,500/PieceGet Latest Price
Minimum Order Quantity: 01 Piece
| Usage/Application | Laboratory |
| Brand | LABIX |
| Warranty | 1 Year |
| Resolution | 0.01 PPM |
| Features | Conductivity/TDS/Salinity/Temp. Meter |
| Display Type | LCD |
| Number Of Ranges | 5 |
| Power | 220-240V AC |
| Type Of Temperature Compensation | Auto/Manual |
| Model number | LBX-513 |
Salient Features
- 128 x 64 dots Graphical LCD Display
- EC, TDS,Satanity & Temperature Measurements
- Auto Temperature Compensation
- Auto Ranging Facility
- Programmable Ref. Temp & Temp. Coeff in EC Mode
- 1000 Samples Storage Facility
- Printer Attachment Facility
View Complete Details
LBX 511 Digital TDS Meter (Inbuilt Stirrer)
₹ 8,600/PieceGet Latest Price
Minimum Order Quantity: 01 Piece
| Usage/Application | Laboratory |
| Measure Range | 2000 ppm |
| Brand | LABIX |
| Warranty | 1 Year |
| Weight | 1 Kg |
| Cell Constant | Adjustable on digital display |
| Dimension | 270x202x80 mm |
| Number Of Ranges | Automatic 5 ranges |
| Power | 220-240V AC |
| Type Of Temperature Compensation | Manual 0-50 DegreeC |
| Model number | LBX-511 |
Technical Specifications
|
Display |
3½ Digit LED |
|
Measurement |
TDS |
|
TDS Ranges |
Automatic 5 Ranges Ranges 0 to 200 ppm, 2000 ppm, 20ppt,200ppt |
|
Stirrer |
Inbuilt Stirrer (with speed variable) |
|
Range Selection |
Automatic in 5 Ranges |
|
Accuracy |
TDS ±0.5% FS± 1Digit Temp. ±1°C ± 1Digit |
|
Temp. Compensation |
MANUAL 0 to 50 °C |
|
Cell Constant |
Adjustable on Digital Display |
|
Measuring Cell |
Platinum DIP Type |
|
Cell Const. |
Auto Measurement |
|
Power |
230V+ 10% AC |
|
Dimensions |
270x202x80 mm (LXBXH) |
|
Weight |
0.8 Kg approx. |
|
Accessories |
TDS Cell, Operation Manual, Dust Cover, Cell Stand Magnetic Capsule |
View Complete Details
| Usage/Application | Laboratory |
| Brand | LABIX |
| Warranty | 1 Year |
| Resolution | 1 PPM |
| Batteries | 9V DC |
| Weight | 250gm |
| Dimension | 180x85x30mm |
| Display Type | LCD |
| Tds Range | 0-19.99 mS |
| Model Number | LBX-636 |
Technical Specifications
|
MODEL NO. |
LBX-636 |
|
Range |
0-1999 µS 0-19.99mS |
|
Resolution |
1ppm |
|
Impedance |
- |
|
Sensor |
TDS Cell (DIP Type) |
|
Batery |
9V DC |
|
Accuracy |
±1% FS |
|
Temp. Comp. |
- |
|
Display |
3½ Digit LCD |
|
Size |
180x85x30mm |
|
Weight |
250gm. (Approx) |
View Complete Details
| Usage/Application | Laboratory |
| Brand | LABIX |
| Warranty | 1 Year |
| Temperature Range | -5 to 110 DegreeC |
| Cell Constant | Adjustable on digital display |
| Number Of Ranges | Automatic in 5 ranges |
| Power | 220-240V AC |
| Accuracy | +-0.5 % FS +- 1 digit |
| Model number | LBX-517 |
Technical Specifications
|
Display |
3½ Digit LED |
|
Measurement |
TDS |
|
Cond. Ranges |
Automatic 5 Ranges |
|
Range Selection |
Automatic in 5 Ranges |
|
Temp. Range |
-5 to 110°C |
|
Accuracy |
Cond. : ±0.5% FS ± 1Digit Temp. ±0.1°C ± 1 Digit |
|
Temperature Compensation |
Auto 0 to 50°C Manual 0 to 50°C |
|
Cell Constant |
Adjustable on Digital Display |
|
Measuring Cell |
Platinum DIP Type |
|
Cell Const |
Auto measurement |
|
Power |
230V ± 10% AC |
|
Dimensions |
270x202x80 mm (LxBxH) |
|
Weight |
0.8kg Approx. |
|
Accessories |
Conductivity Cell, Operation Manual, Dust Cover, |
|
|
Cell Stand, |
View Complete Details
| Brand | LABIX |
| Dissolved Oxygen Resolution | 1 ppm |
| Usage/Application | Laboratory |
| Dissolved Oxygen Accuracy | +- 2% |
| Warranty | 1 Year |
| Resolution | 1 PPM |
| Display | LCD |
| Dimension | 180X85X30mm |
| Weight | 250gm |
| Model Number | LBX-637 |
Technical Specifications
|
MODEL NO. |
LBX-637 |
|
Range |
0.1-19.9 ppm |
|
Resolution |
1 ppm |
|
Impedance |
- |
|
Sensor |
Amperometric DO Probe |
|
Batery |
9V DC |
|
Accuracy |
±2% FS |
|
Temp. Comp. |
5 to 55°C |
|
Display |
3½ Digit LCD |
|
Size |
180x85x30mm |
|
Weight |
250gm. (Approx) |
View Complete Details
| Model Name/Number | LBX-540 |
| Display Type | 4 Digit LED |
| Usage/Application | Laboratory |
| Count Capacity | 9999 |
| Size | 255X220x100 mm |
| Weight | 3 Kg |
| Memory Back Up | 40 memory backup |
| Brand | LABIX |
| Rated Supply Voltage | 220-240V AC |
Salient Features
- Count Correction Facility
- Result-Count Storage
- Audible Confirmation of Each Count
- Uniform Glare Free Illumination
- Wolffhugel Glass Grid with Focussing Facility
- LED Based illumination
- Auto Marker Pen
View Complete Details
Fully Automatic Hematology Analyzer (Double Chamber))
₹ 4,10,000/PieceGet Latest Price
Minimum Order Quantity: 01 Piece
| Differential Type | 2 Part |
| Automation | Automatic |
| Number Of Chambers | 2 |
| Brand | LABIX |
| Number Of Parameters | LYM |
| Model Name/Number | LBX-721 |
| Sample Mode | Capillary |
| Method | Electrical Impedance |
| Storage | Yes |
Salient Features
- Throughput: 35T/H 8-Inch touch screen 20 parameters
- 3 histograms sample volume 10 µL
- Reagents Only
- Counting Modes
- 100,000 Sample results
- Support LIS and external printer
- CE Marked
View Complete Details
| Type Of Ph Meter | Portable |
| Usage/Application | Laboratory |
| Resolution | 0.01 pH |
| Model Name/Number | LBX-634 |
| Brand | LABIX |
| Weight | 250gm |
| Display Type | LCD |
| Ph Range | 0-14 pH |
| Warranty | 1 year |
| Battery Type | 9V DC |
Technical Specifications
|
MODEL NO. |
LBX-634 |
|
Range |
0-14 pH |
|
Resolution |
0.01pH |
|
Impedance |
> 1012ohms |
|
Sensor |
Combination pH Electrode |
|
Batery |
9V DC |
|
Accuracy |
0.01pH |
|
Temp. Comp. |
0-100°C (Manual) |
|
Display |
3½ Digit LCD |
|
Size |
180 x 85 x 30mm |
|
Weight |
250gm. (Approx) |
View Complete Details
| Display Type | LCD |
| Dimension | 180x85x30mm |
| Weight | 250gm |
| Warranty | 1 year |
| Portable | Yes |
| Brand | LABIX |
| Model number | LBX-635 |
| Range | 0-19.99 mS |
Technical Specifications
|
MODEL NO. |
LBX-635 |
|
Range |
0-1999 µS 0-19.99mS |
|
Resolution |
1µS |
|
Impedance |
- |
|
Sensor |
Cond Cell ( Dip Type) |
|
Batery |
9V DC |
|
Accuracy |
±1% FS |
|
Temp. Comp. |
- |
|
Display |
3½ Digit LCD |
|
Size |
180x85x30mm |
|
Weight |
250gm. (Approx) |
View Complete Details
- Developed and Managed by IndiaMART InterMESH Limited