Fault Locater
FADOS7F1 Fault Detector and Oscilloscope
Rs 1.15 Lakhs / UnitGet Latest Price
Usage/Application | PCB Repair,Component Testing,VI Graph |
Model Name/Number | FADOS7F1 |
Type Of Circuit | Parallel Circuit |
Frequency | 50 Hz |
Voltage | 10 V |
Country of Origin | Made in India |
Number of Channels | 2 Channels |
Scan Modes | Manual or Automatic. Automatic selection steps of voltage, current, frequency |
FADOS multifunction circuit board testers have been specially developed to dermine and troubleshoot faults at all type electronic circuit boards. They are basically computer based VI testers. The Fados 7F1 which stands for FAult Detector and OScilloscope 7 Functions in 1 .
FADOS 7F1 can be used for determining faults of all types of PCBs present in Electronic devices used in medical, textile industries, Electronic Appliances and other large automated devices used in the Automobile Industry as well. It can also be used as a component tester for IC, transistor, FET, IGBT, resistor, capacitor, indicator.FADOS7F1 is a double-channel VI tester. While using TEST feature, a comparison can be conducted without giving energy to the card; while using OSCILLOSCOPE feature, energy is given to card and signals are controlled.
View Complete Details
Sheath Fault Tester
Rs 8.5 Lakhs / UnitGet Latest Price
Usage/Application | Industrial |
Country of Origin | Made in India |
Test Voltage | 12 kV DC |
Test Current | 100 mA DC |
Pulse ratio for Pin-pointing | 1:3 second and 1:6 second selectable |
Fault Distance Calculator LCD Display | 16x2 characters with back light |
Power Supply | 230V AC, 50 Hz, Single phase |
Receiver | Sheath Fault Locator EFL 1 |
Application :-
Use to Conditioning / DC Test / Burn, Pre-locate and Pin-point sheath faults in underground extra high voltage power cable transmission networks.
Key Features
Test Voltages 0 - 3, 0 - 6 & 0 - 12 kV DC continuously variable.
Test Current 3 kV - 400 mA, 6 kV - 200 mA, 12 kV - 100 mADC.
Pulse ratio for Pin-pointing 1:3 second and 1:6 second selectable, ON OFF time ratio.
Fault distance Calculator LCD display-16x2 characters withback light.
Cable sheath fault pin pointing by pool of potential method.
Burn mode for conditioning the sheath fault.
Power Supply 230V AC + 10%, 50 Hz, Single phase.
Receiver - Sheath Fault Locator EFL
Standard Accessories:
HV Cable 6sq mm single core screen cable 5 meter length
Mains supply cord 3 meter length.
Yellow / Green 10 sq mm earthing cable 5 meter length
Sheath Fault Locator EFL 1 - 1No.
Earth Spikes - 2Nos
Standard Warranty: One Year
View Complete Details
Trolley Mounted HT Cable Fault Locating System HICOMP
Rs 7.45 Lakhs / PieceGet Latest Price
Usage/Application | Industrial |
Country of Origin | Made in India |
Product | Trolley Mounted HT Cable Fault Locating System HICOMP |
Output Voltage | 16 kV |
Energy | 500 Joules |
Pre-Location Of Cable Faults Range | 100 km |
Power Supply | 230V AC , 50Hz single phase |
Trolley Mounted HT Cable Fault Locating System HICOMP
Application :-
The cable fault locating system HICOMP is used to pre-location offault distance with the help of pre-locator and pin-point cablefault using surge tester in acoustic method with the help of surgewave receiver in low voltage power cable network
Standard Accessories:
HV Output Cable 10 sqmm single core screen 15 meter length with heavyduty clamp. Mains supply cable 6 sq. mm 15meter length.
Yellow / Green 10 sq mm earthingcable 15 meter length BNC to crocodile for TDR measurements 15 meter length
Standard Warranty: One Year
View Complete Details
TFL 8 Cable Fault Pre-Locator
Get Latest Price
Model Name/Number | TFL 8 |
Usage/Application | Industrial |
Country of Origin | Made in India |
Maximum Measuring Range | Up to 100 km |
Display | Big 7" color LED screen with Touchscreen operation |
Power Source | Battery Operated |
Application :
It is used for pre-location of short circuit, open circuit fault distancein Low Voltage Impulse method and low insulation / high resistance/ flashing fault in Impulse Current method ICM with the help of suitable surge tester by power transmission, distribution network companies and cable fault location service providers.
Standard Accessories:
Low voltage Impulse (TDR) testing cable Impulse current method (ICM)testing cable
Re-chargeable battery charger /Adapter
Software CD Carrying case Instruction /
UserManual
Standard Warranty: One Year
View Complete Details
FEDOS9F1 Fault Detector & Oscilloscope
Get Latest Price
Usage/Application | PCB Repair, Component Testing, VI Graph |
Model Name/Number | FEDOS9F1 |
Frequency | 50 Hz |
Voltage | 10 V |
Country of Origin | Made in India |
Type Of Circuit | Parallel Circuit |
FADOS9F1 Fault Detector & Oscilloscope 9 Functions in 1 have been especiallydeveloped to determine and troubleshooting faults at all type electronic circuit boards. FADOS9F1 is basically computer-based VI testerVoltage-Current (Signature Analysis) equipment.
FADOS9F1 includes 9 important functions
1. Double - Channel Fault Detection (Analog Signature Analysis - VI Graph) Comparing good and faulty or suspect circuit boards without giving power to boards.
2. DC Power Supply Output with Adjustable Voltage and Current For giving energy to circuit boards and creating Power DC Voltage-Current Graph.
3. Non Touched IR Temperature Sensor For detecting more heated components and draw out heat map of circuit board.
4. Equivalent Circuit Diagram Composing R, C, or Diode Circuit Diagram according to the point touched.
5. Measuring Value of Resistors, Capacitors, and Diodes Feature of measuring the value of touched point.
6. Fault Detection by Comparison from Memory By recording data of good circuit boards to memory, comparing faulty or suspects boards from memory.
7. Double - Channel Digital Oscilloscope As occasion may require, device can be used as oscilloscope.
8. Square Wave Signal Output Ch.1 is used as oscilloscope and Ch.2 is used as signal generator.
9. Analogue Voltage Output Ch.1 is used as oscilloscope and Ch.2 gives analog voltage output.
View Complete Details
High Voltage DC Test Set HVG 40
Get Latest Price
Usage/Application | Industrial |
Voltage | 230V AC |
Phase | Single phase |
Country of Origin | Made in India |
Output Voltage | 40 kV DC |
Output Current | 20mA |
Duty Cycle | 5 min ON / 10 min OFF |
Frequency | 50 Hz |
High voltage DC test set is used to check Di-electric strength of Cable, Transformers, Switchgear & Relays, Motors, Coils & Chokes, Generators, Capacitors, Wires & Cables, and other Electrical apparatus manufacturers or in power transmission and distribution network.
Fully protected operation with safety interlocks.
Easy to perform DC highvoltage test. Comprehensive safety operation. Continuously adjustableoutput voltage from 0 to 100%.
Output over current tripping facility.
Full current delivering capacity on load. Emergency off switching facility incase of any emergency.
Selectable current ranges for precise leakagecurrent readings.
Built in auto discharge in case of mains power failure orequipment switch off.
Timer provision to switch off the equipmentautomatically after the preset time setting.
Pre-location cable faults indecay or voltage transient mode with conjunction suitable pre-locator.
Rugged construction and easy to carry on site
Standard Warranty: One Year
Standard Accessories :
HV Output Cable 10 sq mmsingle core screen cable 5 meter length with heavyduty clamp. Mains supply cord 3 meter length.
Yellow / Green 10 sq mm earthing cable 5 meter length
Surge Wave Receiver
View Complete Details