Adopts PC-based architecture, conforms IEC 61131-3 standards and PLCopen Function Blocks for Motion Control.

NJ-Series NJ101 CPU Units
Interested in this product?
Get Best Quote
Specifications:

ItemNJ101-[][][][]
EnclosureMounted in a panel
Grounding MethodGround to less than 100 Ω
Dimensions 
(height×depth×width)
90 mm × 90 mm × 90 mm
Weight550 g (including the End Cover)
Current Consumption5 VDC, 1.90 A (including SD Memory Card and End Cover)
Power consumption--
Operation 
Environment
Ambient Operating 
Temperature
0 to 55°C
Ambient Operating 
Humidity
10% to 90% (with no condensation)
AtmosphereMust be free from corrosive gases.
Ambient Storage 
Temperature
-20 to 75°C (excluding battery)
Altitude2,000 m or less
Pollution Degree2 or less: Conforms to JIS B3502 and IEC 61131-2.
Noise Immunity2 kV on power supply line (Conforms to IEC 61000-4-4.)
Overvoltage CategoryCategory II: Conforms to JIS B3502 and IEC 61131-2.
EMC Immunity LevelZone B
Vibration ResistanceConforms to IEC 60068-2-6. 
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz 
Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions 
(10 sweeps of 10 min each = 100 min total)
Shock ResistanceConforms to IEC 60068-2-27. 
147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units)
BatteryLife5 years at 25°C
ModelCJ1W-BAT01
Applicable StandardsConforms to cULus, NK, LR, EC Directives, C-Tick and KC Registration*
 

View Complete Details

Yes, I am interested!

NJ-Series NJ501 CPU Units
Interested in this product?
Get Best Quote
Specifications:

ItemNJ501-[][][][]
EnclosureMounted in a panel
Grounding MethodGround to less than 100 Ω
Dimensions 
(height×depth×width)
90 mm × 90 mm × 90 mm
Weight550 g (including the End Cover)
Current Consumption5 VDC, 1.90 A (including SD Memory Card and End Cover)
Power consumption--
Operation 
Environment
Ambient Operating 
Temperature
0 to 55°C
Ambient Operating 
Humidity
10% to 90% (with no condensation)
AtmosphereMust be free from corrosive gases.
Ambient Storage 
Temperature
-20 to 75°C (excluding battery)
Altitude2,000 m or less
Pollution Degree2 or less: Conforms to JIS B3502 and IEC 61131-2.
Noise Immunity2 kV on power supply line (Conforms to IEC 61000-4-4.)
Overvoltage CategoryCategory II: Conforms to JIS B3502 and IEC 61131-2.
EMC Immunity LevelZone B
Vibration ResistanceConforms to IEC 60068-2-6. 
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz 
Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions 
(10 sweeps of 10 min each = 100 min total)
Shock ResistanceConforms to IEC 60068-2-27. 
147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units)
BatteryLife5 years at 25°C
ModelCJ1W-BAT01
Applicable StandardsConforms to cULus, NK, LR, EC Directives, C-Tick and KC Registration*.
 

View Complete Details

Yes, I am interested!

NJ-series Database Connection CPU Units
Interested in this product?
Get Best Quote
Specifications:

General Specification

For the common specifications of the NJ-series NJ501, refer to the Machine Automation Controller NJ/NX-Series Datasheet.

Performance Specifications

 

ItemNJ501-
152014201320
ProgrammingMemory for CJ-Series Units (Can be Specified 
with AT Specifications for Variables.)
EM Area32,768 words 25 banks * 
(E0_00000 to E18_32767)

 

 

* When the Spool function is enabled, the DB Connection Service uses E9_0 to E18_32767. 
Furthermore, for the common specifications of the NJ-series NJ501, refer to the Machine Automation Controller NJ/NX-Series Datasheet. 
Refer to the specifications of the NJ501-[]5[]0 for those of the NJ501-1520, the NJ501-[]4[]0 for the NJ501-1420, and the NJ501-[]3[]0 for the NJ501-1320.

 

Function Specifications

 

ItemNJ501-1[]20
Ver.1.07 or ealierVer.1.08 or later
DebuggingData TracingMaximum number of simultaneous 
data traces
42

 

Furthermore, for the common specifications of the NJ-series NJ501, refer to the Machine Automation Controller NJ/NX-Series Datasheet.

Functions Supported by NJ501-1[]20

Besides functions of the NJ501-, functions supported by the NJ501-120 are as follows.

 


 

View Complete Details

Yes, I am interested!

NJ-Series NJ301 CPU Units
Interested in this product?
Get Best Quote
Specifications:

ItemNJ301-[][][][]
EnclosureMounted in a panel
Grounding MethodGround to less than 100 Ω
Dimensions 
(height×depth×width)
90 mm × 90 mm × 90 mm
Weight550 g (including the End Cover)
Current Consumption5 VDC, 1.90 A (including SD Memory Card and End Cover)
Power consumption--
Operation 
Environment
Ambient Operating 
Temperature
0 to 55°C
Ambient Operating 
Humidity
10% to 90% (with no condensation)
AtmosphereMust be free from corrosive gases.
Ambient Storage 
Temperature
-20 to 75°C (excluding battery)
Altitude2,000 m or less
Pollution Degree2 or less: Conforms to JIS B3502 and IEC 61131-2.
Noise Immunity2 kV on power supply line (Conforms to IEC 61000-4-4.)
Overvoltage CategoryCategory II: Conforms to JIS B3502 and IEC 61131-2.
EMC Immunity LevelZone B
Vibration ResistanceConforms to IEC 60068-2-6. 
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz 
Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions 
(10 sweeps of 10 min each = 100 min total)
Shock ResistanceConforms to IEC 60068-2-27. 
147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units)
BatteryLife5 years at 25°C
ModelCJ1W-BAT01
Applicable StandardsConforms to cULus, NK, LR, EC Directives, C-Tick and KC Registration*.
 

View Complete Details

Yes, I am interested!

NJ-Series Power Supply Unit NJ-PA / PD
Interested in this product?
Get Best Quote
Specifications:

ItemSpecifications
ModelNJ-PA3001NJ-PD3001
Supply voltage100 to 240 VAC (wide-range), 50/60 Hz24 VDC
Operating voltage and 
frequency ranges
85 to 264 VAC, 47 to 63 Hz19.2 to 28.8 VDC
Power consumption120 VA max.60 W max.
Inrush current *1At 100 VAC: 20 A/8 ms max. for cold start at 
room temperature 
At 200 VAC: 40 A/8 ms max. for cold start at 
room temperature
At 24 VDC: 30 A/20 ms max. for cold start
Output capacity *25 VDC, 6.0 A (including supply to CPU Unit using CPU Rack) 
5 VDC, 6.0 A (using Expansion Rack) 
24 VDC, 1.0 A 
Total: 30 W max.
Output terminal 
(service supply)
Not provided
RUN output *3Contact configuration: SPST-NO 
Switch capacity: 250 VAC, 2 A (resistive load) 
120 VAC, 0.5 A (inductive load), 24 VDC, 2A (resistive load)
Replacement 
notificationfunction
Not provided
Insulation resistance 
*4
20 MΩ min. (at 500 VDC) between AC 
external and GR terminals
20 MΩ min. (at 500 VDC) between DC 
external and GR terminals
Dielectric strength 
*4 *5
2,300 VAC 50/60 Hz for 1 min between AC 
external and GR terminals 
Leakage current: 10 mA max.
1,000 VAC 50/60 Hz for 1 min between DC 
external and GR terminals 
Leakage current: 10 mA max.
Noise immunity2 kV on power supply line (Conforms to IEC 61000-4-4.)
Vibration resistance5 to 8.4 Hz, 3.5-mm amplitude, 8.4 to 150 Hz, acceleration: 9.8 m/s2 in X, Y, and Z directions 
for 100 min (Time coefficient: 10 min × coefficient factor 10 = total time 100 min) 
(according to IEC 60068-2-6)
Shock resistance147 m/s2 3 times each in X, Y, and Z directions (Relay Output Unit: 100 m/s2) (according to 
IEC 60068-2-27)
Ambient operating 
temperature
0 to 55°C
Ambient operating 
humidity
10% to 90% (with no condensation)
AtmosphereMust be free from corrosive gases.
Ambient storage 
temperature
-20 to 75°C
GroundingLess than 100 Ω
EnclosureMounted in panel
Weight470 g max.490 g max.
CPU Rack dimensions174.7 to 484.7 × 90 × 90 mm (W × D × H) (not including cables) 
W = 70 (Power Supply Unit) 90 (CPU Unit) 20 × n 31 × m 14.7 (end cover) 
n is the number of 32-point I/O Units or I/O Control Units and m is the number of other Units.
Safety measuresConforms to cULus, EC Directives, NK and LR.
 

View Complete Details

Yes, I am interested!

CJ-series Input Units CJ1W-ID / IA
Interested in this product?
Get Best Quote
Specifications:

CJ1W-ID201 DC Input Unit (12 to 24-VDC, 8 Points)

 

Name8-point DC Input Unit with Terminal Block
ModelCJ1W-ID201
Rated Input Voltage12 to 24 VDC
Rated Input Voltage Range10.2 to 26.4 VDC
Input Impedance2.4 kΩ
Input Current10 mA typical (at 24 VDC)
ON Voltage/ON Current8.8 VDC min./3 mA min.
OFF Voltage/OFF Current3 VDC max./1 mA max.
ON Response Time8.0 ms max. (Can be set to between 0 and 32 ms in the Setup.) *1
OFF Response Time8.0 ms max. (Can be set to between 0 and 32 ms in the Setup.) *1
Number of Circuits8 independent circuits
Number of Simultaneously
ON Points
100% simultaneously ON
Insulation Resistance20 MΩ between external terminals and the GR terminal (100 VDC)
Dielectric Strength1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of 
10 mA max.
Internal Current Consumption80 mA max.
Weight110 g max.
 

View Complete Details

Yes, I am interested!

CJ-series Output Units CJ1W-OC / OA / OD
Interested in this product?
Get Best Quote
Specifications:

CJ1W-OC201 Contact Output Unit (Independent Relays, 8 Points)

 

Name8-point Contact Output Unit with Terminal Block (Independent Relays)
ModelCJ1W-OC201
Max. Switching Capacity2 A 250 VAC (cosφ = 1), 2 A 250 VAC (cosφ = 0.4), 2 A 24 VDC (16 A/Unit)
Min. Switching Capacity1 mA 5 VDC
RelaysNY-24W-K-IE (Fujitsu Takamizawa Components, Ltd.), Cannot be replaced.
Service Life of RelayElectrical: 150,000 operations (24 VDC, resistive load)/100,000 operations (240 VAC, cosφ 
= 0.4, inductive load) 
Mechanical: 20,000,000 operations 
Service life will vary depending on the connected load.
ON Response Time15 ms max.
OFF Response Time15 ms max.
Number of Circuits8 independent contacts
Insulation Resistance20 MΩ between external terminals and the GR terminal (500 VDC)
Dielectric Strength2,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage 
current of 10 mA max.
Internal Current 
Consumption
90 mA 5 VDC max. 
48 mA 24 VDC max. (6 mA × No. of ON points)
Weight140 g max.
 

View Complete Details

Yes, I am interested!

CJ-Series Mixed I/O Units CJ1W-MD
Interested in this product?
Get Best Quote
Specifications:

CJ1W-MD231 DC Input/Transistor Output Unit (24 VDC, 16 Inputs/16 Outputs)

 

Name16-point DC Input/16-point Transistor Output Unit with Fujitsu Connectors (Sinking Outputs)
ModelCJ1W-MD231
Output section (CN1)Input section (CN2)
Rated Voltage12 to 24 VDCRated Input Voltage24 VDC
Operating Load 
Voltage Range
10.2 to 26.4 VDCOperating Input 
Voltage
20.4 to 26.4 VDC
Maximum Load 
Current
0.5 A/point, 2.0 A/UnitInput Impedance3.3 kΩ
Maximum Inrush 
Current
4.0 A/point, 10 ms max.Input Current7 mA typical (at 24 VDC)
Leakage Current0.1 mA max.ON Voltage/ON 
Current
14.4 VDC min./3 mA min.
Residual Voltage1.5 V max.OFF Voltage/OFF 
Current
5 VDC max./1 mA max.
ON Response 
Time
0.1 ms max.ON Response Time8.0 ms max. (Can be set 
to between 0 and 32 in 
the Setup.) *
OFF Response 
Time
0.8 ms max.
No. of Circuits16 (16 points/common, 1 circuit)OFF Response Time8.0 ms max. (Can be set 
to between 0 and 32 in 
the Setup.) *
FuseNone
External Power 
Supply
12 to 24 VDC, 20 mA min.No. of Circuits16 (16 points/common, 
1 circuit)
Number of 
Simultaneously 
ON Points
75% (at 24 VDC)
Insulation 
Resistance
20 MΩ between the external terminals and the GR terminal (at 100 VDC)
Dielectric 
Strength
1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of 
10 mA max.
Internal Current 
Consumption
5 VDC 130 mA max.
 

View Complete Details

Yes, I am interested!

CJ-Series Interrupt Input Units CJ1W-INT01
Interested in this product?
Get Best Quote
Specifications:

CJ1W-INT01 Interrupt Input Unit (16 Points)

 

Name16-point Interrupt Input Unit with Terminal Block
ModelCJ1W-INT01
Rated Input Voltage24 VDC
Rated Input Voltage Range20.4 to 26.4 VDC
Input Impedance3.3 kΩ
Input Current7 mA typical (at 24 VDC)
ON Voltage/ON Current14.4 VDC min./3 mA min.
OFF Voltage/OFF Current5 VDC max./1 mA max.
ON Response Time0.05 ms max.
OFF Response Time0.5 ms max.
Number of Circuits16 (16 points/common, 1 circuit)
Number of Simultaneously 
ON Points
100% (16 points/common) simultaneously ON (24 VDC)
Insulation Resistance20 MΩ between external terminals and GR terminal (at 100 VDC)
DielectrQic Strength1,000 VAC between external terminals and GR terminal for 1 minute at a leakage current of 10 mA max.
Internal Current 
Consumption
80 mA max.
Weight110 g max.
AccessoriesNone
 

View Complete Details

Yes, I am interested!

CJ-Series Quick-response Input Units CJ1W-IDP01
Interested in this product?
Get Best Quote
Specifications:

CJ1W-IDP01 Quick-response Input Unit (16 Points)

 

Name16-point Quick-response Input Unit with Terminal Block
ModelCJ1W-IDP01
Rated Input Voltage24 VDC
Rated Input Voltage Range20.4 to 26.4 VDC
Input Impedance3.3 kΩ
Input Current7 mA typical (at 24 VDC)
ON Voltage/ON Current14.4 VDC min./3 mA min.
OFF Voltage/OFF Current5 VDC max./1 mA max.
ON Response Time0.05 ms max.
OFF Response Time0.5 ms max.
Number of Circuits16 (16 points/common, 1 circuit)
Number of Simultaneously 
ON Points
100% (16 points/common) simultaneously ON (24 VDC)
Insulation Resistance20 MΩ between external terminals and GR terminal (at 100 VDC)
Dielectric Strength1,000 VAC between external terminals and GR terminal for 1 minute at a leakage current of 
10 mA max.
Internal Current 
Consumption
80 mA max.
Weight110 g max.
AccessoriesNone
 

View Complete Details

Yes, I am interested!

CJ-Series B7A Interface Unit CJ1W-B7A
Interested in this product?
Get Best Quote
Specifications:

B7A Communications Specifications

 

ItemSpecifications
Transmission methodOne-way time-sharing multiplex transmissions
Transmission delay
(communications delay
on transmission path)
High-speed3 ms typical, 5 ms max.
Standard19.2 ms typical, 31 ms max.
Transmission pointsCJ1W-B7A1464 inputs (4 ports)
CJ1W-B7A0464 outputs (4 ports)
CJ1W-B7A2232 inputs (2 ports), 32 outputs (2 ports)
External power supply
voltage *1
12 to 24 V DC (allowable voltage range: 10.8 to 26.4 V)
External supply
current *2
CJ1W-B7A1440 mA min.
CJ1W-B7A04150 mA min.
CJ1W-B7A2280 mA min.
Minimum input time
*3
High-speed16 ms
Standard2.4 ms
Transmission distanceHigh-speedPower supply on one side
(common power supply)
10 m max.
50 m max. (with shielded cable)
Power supply on both sides
(separate power supplies)
10 m max.
100 m max. (with shielded cable)
StandardPower supply on one side
(common power supply)
100 m max.
Power supply on both sides
(separate power supplies)
500 m max.
CablesVCTF, 0.75 mm2, 3 conductors (power supply on one side (common power supply))
VCTF, 0.75 mm2, 2 conductors (power supply on both sides (separate power supplies))
Shielded cable, 0.75 mm2, 3 conductors (power supply on one side (common power supply))
Shielded cable, 0.75 mm2, 2 conductors (power supply on both sides (separate power supplies))
 

View Complete Details

Yes, I am interested!

CJ-series CompoNet Master Units CJ1W-CRM21
Interested in this product?
Get Best Quote
Specifications:

Communication Specifications

 

ItemSpecification
Communications protocolCompoNet Network protocol
Types of communicationsRemote I/O communications (programless,constant sharing of data with Slave Units)and message 
communications (explicit message communications as required with Slave Units and FINS message 
communications as required with Controllers *1)
Baud rate4 Mbps *2,3 Mbps,1.5 Mbps,93.75 kbps
ModulationBase-band
CodingManchester code
Error controlManchester code rules,CRC
Communications mediaThe following media can be used.*3 
Round cable I (JIS C 3306,2-conductor 0.75 mm2
Round cable II (JIS C3306 4-conductor 0.75 mm2
Flat Cable I (DCA4-4F10 Standard Flat Cable) 
Flat Cable II (DCA5-4F10 Sheathed Flat Cable)
Communications distance 
and wiring
Refer to Cable Types,Baud Rates,and Maximum Distances.
Connectable Master UnitsCompoNet Master Units
Connectable Slave UnitsCompoNet Slave Units
Maximum I/O capacityWord Slave Units:1,024 inputs and 1,024 outputs (2,048 I/O points total) 
Bit Slave Units:256 inputs and 256 outputs (512 I/O points total)
Maximum number of nodesWord Slave Units:64 input nodes and 64 output nodes 
Bit Slave Units:128 input nodes and 128 output nodes 
Repeater Units:64 nodes
Bits allocated per node 
address
Word Slave Units:16 bits 
Bit Slave Units:2 bits
Maximum number of nodes 
per trunk line or sub-trunk 
line
32 nodes (including Repeater Units)
 

View Complete Details

Yes, I am interested!

CJ-Series Analog I/O Unit CJ1W-AD / DA / MAD
Interested in this product?
Get Best Quote
Specifications:

ItemCJ1W-AD041-V1CJ1W-AD081-V1CJ1W-AD042
Unit typeCJ-series Special I/O Unit
Isolation *1Between I/O and Controller signals: Photocoupler
(No isolation between I/O signals.)
Between I/O and Controller signals:
Digital isolator (No isolation between I/O signals.)
External terminals18-point detachable terminal block (M3 screws)
Power consumption420 mA max. at 5 VDC520 mA max. at 5 VDC
Dimensions (mm)31 × 90 × 65 mm (W × H × D)
Weight140 g max.150 g max.
General specificationsConforms to general specifications for CJ Series.
Input
specifi-
cations
Number of analog inputs484
Input signal range *21 to 5 V
0 to 5 V
0 to 10 V
- 10 to 10 V
4 to 20 mA
*3
1 to 5 V
0 to 10 V
- 5 to 5 V
- 10 to 10 V
4 to 20 mA
*4
Maximum rated input
(for 1 point) *5
Voltage Input: ± 15 V
Current Input: ± 30 mA
Input impedanceVoltage Input: 1 MΩ min. Current Input: 250 Ω (rated value)
Resolution4,000/8,000 *61 to 5 V10,000
0 to 10 V20,000
- 5 to 5 V20,000
- 10 to 10 V40,000
4 to 20 mA10,000
Converted output data16-bit binary data
Accuracy
*7
25 °C *8Voltage Input: ± 0.2% of F.S. Current Input: ± 0.4% of F.S.
0 °C to 55 °CVoltage Input: ± 0.4% of F.S. Current Input: ± 0.6% of F.S.
A/D conversion period *91 ms/250 μs per point *620 μs/1 point, 25 μs/2 points,
30 μs/3 points, 35 μs/4 points
 

View Complete Details

Yes, I am interested!

CJ-series Process Analog I/O Unit CJ1W-PDC15
Interested in this product?
Get Best Quote
Specifications:

ItemSpecifications
ModelCJ1W-PDC15
Applicable ControllerCJ/NJ Series
Unit classificationCJ-series Special I/O Unit
Mounting positionCPU Rack or Expansion Rack
Maximum number of Units40 (within the allowable current consumption and power consumption range)
Unit numbers00 to 95 (Cannot duplicate Special I/O Unit numbers.)
Areas for
data
exchange
with CPU
Unit
Special I/O Unit
Area
(Operation Data)
10 words/Unit
Direct Current Input Unit to CPU Unit:
All process values, process value alarms (LL, L, H, HH), rate-of-change values, rate-of-change alarms
(L, H), disconnection alarms, cold junction sensor errors, adjustment period end/notice
DM Area words
allocated to
Special I/O Units
(Setting parameter)
100 words/Unit
CPU Unit to Direct Current Input Unit:
Input signal type, scaling of process value in industrial units, process value alarm setting (L, H), inrush
input upper limit, inrush input upper limit time, zero/span adjustment value, Square root function.
Temperature input signal type, input range (user set), scaling of process value data to be stored in
allocated words in CIO area, rate-of-change input range, scaling of rate-of-change data, number of
items for moving average, process value alarm setting (LL, L, H, HH), rate-of-change alarm setting (L,
H), zero/span adjustment value
Expansion Control/
Monitor Area
(Expansion
Operation Data)
35 words/Unit
CPU Unit to Direct Current Input Unit:
Bits for beginning or resetting the hold function selection, adjustment period control, control bits
Direct Current Input Unit to CPU Unit:
Adjustment period notices, peak and bottom values, top and valley values, integral values
Expansion Setting
Area
(Expansion Setting
parameter)
46 words/Unit
CPU Unit to Direct Current Input Unit:
Expansion Setting Area settings, adjustment period control, peak and bottom detection, top and valley
detection, integral value calculation
 

View Complete Details

Yes, I am interested!

CJ Series Temperature Control Unit CJ1W-TC
Interested in this product?
Get Best Quote
Specifications:

ItemSpecification
Unit classificationCJ-series Special I/O Unit
Compatible RacksCJ-series CPU Rack or CJ-series Expansion Rack
Max. number of
Units
10 Units/Rack max. (CPU Rack or Expansion Rack)
CPU Unit data
areas for data
storage/exchange
Special I/O Unit Area
(960 words)
CIO 2000 to CIO 2959
20 words/Unit for
constant data
exchange (6 output
words and 14
input words)
CPU Unit to
Temperature
Control Unit
Set point (SP)
Operating commands
RUN/STOP control
Start/Stop AT
Write commands
Heater burnout set value
Temperature
Control Unit
to CPU Unit
Process value (PV)
Set point (SP)
Status
Heater current monitor
DM words allocated to
Special I/O Units
(9,600 words)
D20000 to D29599
10 words/Unit
transferred when
power is turned ON or
Unit is restarted
CPU Unit to
Temperature
Control Unit
Alarm mode
Alarm hysteresis
90 words/Unit for regular
data exchange
Two-way
transfer
between CPU
Unit and
Temperature
Control Unit
Alarm value
Input compensation value
Control period
Hysteresis
Proportional band
Integral time
Derivative time
Output monitor
Insulation
resistance
20 M Ω min. (at 500 VDC) between the following points:
All output and NC terminals and external AC terminals (Power Supply Unit)
All input terminals and external AC terminals (Power Supply Unit)
All input terminals and all output terminals
All external DC terminals (inputs, outputs, and NC) and the FG plate
Between input terminals (sensor and CT inputs)
I/O terminals and NC terminals
Dielectric strength2,000 VAC 50/60 Hz for 1 min., detected current: 1 mA
The output terminals/NC terminals and external AC terminals (Power Supply Unit)
1,000 VAC 50/60 Hz for 1 min., detected current: 1 mA
Input terminals and external AC terminals (Power Supply Unit)
Input terminals and output terminals
External DC terminals (inputs, outputs, and NC) and the FG plate
500 VAC 50/60 Hz for 1 min., detected current: 1 mA
Between input terminals (sensor and CT inputs)
I/O terminals and NC terminals
 

View Complete Details

Yes, I am interested!

CJ-Series High-Speed Counter Unit CJ1W-CT021
Interested in this product?
Get Best Quote
Specifications:

ItemCJ1W-CT021
Unit typeCJ-series Special I/O Unit
General SpecificationsConform to general specifications for CJ/NJ-series
Ambient Operating Temperature0 to 55 °C
Ambient Storage Temperature-20 to 75 °C
Ambient Operating Humidity10% to 90% without condensation
Internal Current Consumption280 mA (at 5 V)
Dimensions31 × 90 × 65 mm (W × H × D)
Weight100 g
Mounting PositionCJ-series CPU Rack or CJ-series Expansion Rack *1, NJ-series CPU Rack or NJ-series Expansion Rack
Maximum Number of CT021 
Units per Rack
Equal to the number of slots of the Rack *2
Maximum Number of CT021 
Units per basic CJ/NJ system
24
Data Exchange with CPU UnitI/O Refresh Data Area (CIO-bits 200000 to 255915, CIO-words 2000 to 2959): *3 
Special I/O Unit DM-Area (D-words 20000 to 29599): 400 DM-words per Unit are transmitted form 
the CPU to the Unit at Power Up or when the Unit is restarted *4
 

View Complete Details

Yes, I am interested!

CJ Series ID Sensor Unit CJ1W-V680C11 / V680C12
Interested in this product?
Get Best Quote
Specifications:

ModelCJ1W-V680C11CJ1W-V680C12
Current 
consumption
Internal: 5 V0.26 A0.32 A
Internal: 24 V/26 V0.13 A *0.26 A
External: 24 V--
Ambient operating temperature0 to 55°C
Ambient storage temperature-20°C to 75°C
Ambient operating humidity10% to 90% (with no condensation)
Insulation resistance20 mΩ min. at 500 VDC
Dielectric strength1,000 VAC for 1 minute
Degree of protectionMounted in panel (IP30)
Vibration resistance10 to 57 Hz variable vibration, 0.075-mm double amplitude and 57 to 150 Hz 
variable vibration at 9.8 m/s2 acceleration, with 10 sweeps in X, Y, and Z 
directions for 8 minutes each
Shock resistance147 m/s2 in X, Y, and Z directions 3 times each
Appearance31 × 65 × 90 mm (excluding protrusions)
Weight120 g max.130 g max.
 

View Complete Details

Yes, I am interested!

CJ-Series Process Analog I/O Unit CJ1W-PH41U / AD04U
Interested in this product?
Get Best Quote
Specifications:

ItemSpecifications
ModelCJ1W-AD04U
Applicable ControllerCJ/NJ Series
Type of UnitCJ-series Special I/O Unit
Mounting positionCPU Rack or Expansion Rack
Maximum number of Units40 (within the allowable current consumption and power consumption range)
Unit numbers00 to 95 (Cannot duplicate Special I/O Unit numbers.)
Areas for 
exchanging
data with the 
CPU Unit
Special I/O Unit 
Area words in 
the CIO Area 
(Operation Data)
10 words/Unit
IIsolated-type Universal Input Unit to CPU Unit: 
All process values, process value alarms (L, H), conversion data enabled flag, input errors, cold 
junction sensor errors
Special I/O Unit 
words in the DM 
Area 
(Setting parameter)
100 words/Unit
CPU Unit to Isolated-type Universal Input Unit: 
Input type, scaling upper and lower limits, process value alarm setting (L, H), zero/span adjustment 
value, alarm ON delay time, alarm hysteresis, Expansion Setting Area settings
Expansion Setting 
Area 
(Expansion Setting 
parameter)
1 word/Unit
CPU Unit to Isolated-type Universal Input Unit: Process value alarm output
Number of inputs4
Input typePlatinum resistance thermometer: Pt100 (JIS, IEC), Pt1000, or JPt100 
Thermocouple: K, J, T, L, R, S, or B 
Current: 4 to 20 mA, or 0 to 20 mA 
Voltage: 1 to 5 V, 0 to 5 V, or 0 to 10 V 
Each input can be set independently.Each input can be set independently.
 

View Complete Details

Yes, I am interested!

CJ-Series EtherCAT Slave Unit CJ1W-ECT21
Interested in this product?
Get Best Quote
Specifications:

EtherCAT Slave Unit CJ1W-ECT21

 

ItemSpecification
Model numberCJ1W-ECT21
Applicable PLCsNJ-series, CJ-series, CP-series, NSJ-series
Unit classificationCPU Bus Unit
Applicable unit numbers0 to F
Mounting positionCPU Rack or Expansion Rack
Number of Units that can be mounted16 Units max. (you must allocate unique words)
CPU Unit 
words used
Allocated CIO Area words 
(CPU Bus Unit words) *1
25 words/Unit (one unit number’s words)
Unit Status 1, Unit Status 2, Slave Status 1, Slave Status 2
Allocated DM Area words 
(CPU Bus Unit words) *2
100 words/Unit (one unit number’s words)
I/O Communication Area Setting Table, I/O Communication Area Reference Table
Other I/O memory *3I/O communication area in any area *4
CPU Bus Unit setting areaNot used
Transmission
specifications
Communications protocolEtherCAT protocol
ModulationBaseband
Baud rate100 Mbps
Physical layer100BASE-TX (IEEE 802.3)
TopologyDepends on the specifications of the EtherCAT master
Transmission mediaCategory 5 or higher twisted-pair cable (Recommended cable: double-shielded cable with aluminum tape and braiding)
Transmission distanceDistance between nodes: 100 m or less
 

View Complete Details

Yes, I am interested!

CJ-series EtherNet/IP Unit CJ1W-SCU
Interested in this product?
Get Best Quote
Specifications:

ItemDescription
Device nameSerial Communications Unit
ClassificationCPU Bus Unit
Model numberCJ1W-SCU22CJ1W-SCU32CJ1W-SCU42CJ1W-SCU21-V1CJ1W-SCU31-V1CJ1W-SCU41-V1
Serial
ports
Port 1RS-232CRS-422A/485RS-422A/485RS-232CRS-422A/485RS-422A/485
Port 2RS-232CRS-422A/485RS-232CRS-232CRS-422A/485RS-232C
ProtocolPort 1Host Link, protocol macro, Serial Gateway, No-
protocol, NT Link, Modbus-RTU Slave, loopback
test , or 1:1 Host Link can be selected for each
port. *1, *2
Host Link, protocol macro, NT Link, or loopback test can be
selected for each port.
Unit Ver. 1.2 or later also supports Serial Gateway, no-
protocol, and 1:1 Host Link modes. (Note: The Serial Gateway
can also be executed in protocol macro mode.) *1
Unit Ver. 1.3 or later also supports Modbus-RTU slave mode.
Port 2
Number
of
mountable
Units
CPU UnitNone
CPU RackA total of up to 16 Units, including all other
CPU Bus Units. No
restrictions on the mounting location.
However, if an external interrupt task is used,
the Unit must be mounted in one of the
following slots on the CPU Rack.
CJ2H-CPU6[]-EIP CPU Unit: Slots 0 to 3
CJ2H-CPU6[], CJ2M-CPU[][] or CJ1G/H-
CPU[][]H CPU Unit: Slots 0 to 4
CJ1M-CPU[][] CPU Unit: Slots 0 to 2
External interrupt tasks will not be started if
the Unit is mounted to any other slot.
A total of up to 16 Units, including all other CPU Bus Units.
No restrictions on the mounting location.
Expansion
Rack
Data
exchange
with the
CPU Unit
Ordinary
refreshing
of software
switches
and status
Allocated 25 words of the 25 words in the CPU Bus Unit CIO Area (constant data exchange with the CPU Unit)
Transfer
from the
CPU Unit
set by the
system
Of the CPU Bus Unit DM Area, each serial port is allocated 10 words (total 20 words).
Data is transferred from the CPU Unit at the following times:
Startup or restart
Ladder instruction: STUP (237)
Port Settings Changing Flag turns ON (Auxiliary Area)
 

View Complete Details

Yes, I am interested!

CJ-series EtherNet/IP Unit CJ1W-EIP21
Interested in this product?
Get Best Quote
Specifications:

ItemSpecifications
Model numberCJ1W-EIP21
Type100Base-TX *1
Applicable PLCsNJ-series, CJ (CJ1, CJ2) series, CP1H, and NSJ series PLCs.
Unit classificationCJ-series CPU Bus Unit
Mounting locationCPU Rack or Expansion Rack
Number of Units that can be 
mounted
NJ-series System: 4 max. (including Expansion Racks) 
CJ series System and NSJ series System: 8 max. (including Expansion Racks) *2 
CP1H System: 2 max.
CPU 
Unit 
words 
used
Allocated CIO Area 
words (CPU Bus 
Unit words)
25 words/Unit (one unit number's words)
These words contain control bits and flags, the target node PLC's operating and error
information, Unit status, communications status, registered/normal target node 
information, and FINS/TCP connection status.
Allocated DM Area 
words (CPU Bus 
Unit words)
100 words/Unit (one unit number's words)
These words contain the IP address display/setting area.
User-set areaAny usable data area words
Target node PLC's operating and error information, and registered/normal target 
node information
CPU Bus Unit 
System Setup
Not used.
Non-volatile memory within 
EtherNet/IP Unit 
(See note.)
The following settings are stored in the EtherNet/IP Unit's non-volatile memory. 
Note: Unlike the regular Ethernet Units, the CPU Bus Unit Setup Area in the CPU 
Unit is not used for these settings. 
1. Unit Setup (communications settings for the EtherNet/IP Unit, such as the IP 
address, DNS server settings, host name, baud rate, FINS/UDP settings, and FINS/ 
TCP settings) 
2. Tag data link settings (device parameters)
 

View Complete Details

Yes, I am interested!

CJ-series Serial Communications Units CJ1W-SCU
Interested in this product?
Get Best Quote
Specifications:

ItemDescription
Device nameSerial Communications Unit
ClassificationCPU Bus Unit
Model numberCJ1W-SCU22CJ1W-SCU32CJ1W-SCU42CJ1W-SCU21-V1CJ1W-SCU31-V1CJ1W-SCU41-V1
Serial
ports
Port 1RS-232CRS-422A/485RS-422A/485RS-232CRS-422A/485RS-422A/485
Port 2RS-232CRS-422A/485RS-232CRS-232CRS-422A/485RS-232C
ProtocolPort 1Host Link, protocol macro, Serial Gateway, No-
protocol, NT Link, Modbus-RTU Slave, loopback
test , or 1:1 Host Link can be selected for each
port. *1, *2
Host Link, protocol macro, NT Link, or loopback test can be
selected for each port.
Unit Ver. 1.2 or later also supports Serial Gateway, no-
protocol, and 1:1 Host Link modes. (Note: The Serial Gateway
can also be executed in protocol macro mode.) *1
Unit Ver. 1.3 or later also supports Modbus-RTU slave mode.
Port 2
Number
of
mountable
Units
CPU UnitNone
CPU RackA total of up to 16 Units, including all other
CPU Bus Units. No
restrictions on the mounting location.
However, if an external interrupt task is used,
the Unit must be mounted in one of the
following slots on the CPU Rack.
CJ2H-CPU6[]-EIP CPU Unit: Slots 0 to 3
CJ2H-CPU6[], CJ2M-CPU[][] or CJ1G/H-
CPU[][]H CPU Unit: Slots 0 to 4
CJ1M-CPU[][] CPU Unit: Slots 0 to 2
External interrupt tasks will not be started if
the Unit is mounted to any other slot.
A total of up to 16 Units, including all other CPU Bus Units.
No restrictions on the mounting location.
Expansion
Rack
 

View Complete Details

Yes, I am interested!

CJ-series DeviceNet Unit CJ1W-DRM21
Interested in this product?
Get Best Quote
Specifications:

ItemSpecifications
Communications protocolDeviceNet
Connection methodsMulti-drop and T-branch connections can be combined (for trunk and branch lines) *1
Baud rate500 Kbps, 250 Kbps, or 125 Kbps
Communications mediaSpecial 5-wire cables (2 signal lines, 2 power lines, 1 shield line)
Special 4-wire flat cables (2 signal lines, 2 power lines)
Communications distances for
special 5-wire cables
Baud rateNetwork lengthBranch line lengthTotal branch line length
500 kbps100 m max.6 m max.39 m max.
250 kbps250 m max. *26 m max.78 m max.
125 kbps500 m max. *26 m max.156 m max.
Communications distances for
special 4-wire flat cables
Baud rateNetwork lengthBranch line lengthTotal branch line length
500 kbps75 m max.6 m max.35 m max.
250 kbps150 m max.6 m max.48 m max.
125 kbps265 m max.6 m max.135 m max.
Communications power supply24 V DC supplied externally
Max. number of nodes64 nodes (including Masters, Slaves, and Configurator)
 

View Complete Details

Yes, I am interested!

CJ-series I/O Control Unit / I/O Interface Unit
Interested in this product?
Get Best Quote
  • Rack-mountable Units enable expanding Controller capacity even when space is limited.
  • Easy-to-use connectors enable quick expansion without any settings

View Complete Details