Limit Switch are basic switches that have been encased to protect them from external forces, water, oil, and dirt. Many models are available, such as those resistant to head, cold, or corrosion, as well as high-precision models.

Two-circuit Limit Switch/Long-life Two-circuit Limit Switch
Interested in this product?
Get Best Quote
Specifications:

 
General-purpose/ Environment-resistant SwitchesRatingsScrew Terminals

 

ItemRated voltage 
(V)
Non-inductive load (A)Inductive load (A)
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
BasicAC125 
250 
500
10 
10 
10


1.5
1.5 

0.8
10 
10 
3


1.5
2.5 
1.5 
0.8
DC
14 
30 
125 
250
10 
10 

0.8 
0.4



0.2 
0.1



0.2 
0.1
10 
10 

0.8 
0.4



0.2 
0.1
High-sensitivity 
High-precision
AC125 
250

5
------------
DC125 
250
0.4 
0.2
------------

 

 

Note: 1. The above figures are for steady-state currents. 
           2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 
           3. A lamp load has an inrush current of 10 times the steady-state current. 
           4. A motor load has an inrush current of 6 times the steady-state current. 
           5. For PC loads, use the microload models.

 

 

Inrush currentNC30 A max.(15 A max. *)
NO20 A max.(10 A max. *)

 

* For high-sensitivity and high-precision switches.

 

Minimum applicable load5 VDC 1 mA, resistive load, P level

View Complete Details

Yes, I am interested!

Enclosed Switch D4C
Interested in this product?
Get Best Quote

Enclosed Switch D4C

Get Latest Price

Specifications:

RatingsStandard Model

 

Rated voltageNon-inductive load (A)Inductive load (A)
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125 VAC
250 VAC
5 (0.1)
5
1.5
1
0.7
0.5
3
2
2.5
1.5
1.3
0.8
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
5 (0.1)
5 (0.1)
4 (0.1)
0.4
0.2
2
2
2
0.05
0.03
5
4
3
4
4
3
3
3
3
0.05
0.03
0.4
0.2

 

 

Inrush currentNC20 A max.
NO10 A max.

 

 

Note: 

1. The values given on the left are steady-statecurrents.

2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).

3. Lamp loads have an inrush current of 10 times the steady-state current.

4. Motor loads have an inrush current of 6 times the steady-state current.

5. The values "0.1" given in parentheses are for micro load models.

 

Pre-wired Model

 

Rated voltageNon-inductive load (A)Inductive load (A)
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125 VAC1110.71111
30 VDC11111111
 

View Complete Details

Yes, I am interested!

Miniature Limit Switch D4CC
Interested in this product?
Get Best Quote
Specifications:

Ratings

 

Rated voltageNon-inductive load (A)Inductive load (A)
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125 VAC1110.71111
30 VDC11111111
Note: 1. The above current ratings are for steady-state current. 
          2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 
          3. Lamp loads have an inrush current of 10 times the steady-state current. 
          4. Motor loads have an inrush current of 6 times the steady-state current.

 

D4CC-3, D4CC-4, 1 A at 30 VDC

 

Inrush currentNC5 A max.
NO2.5 A max.

 

Characteristics

 

Degree of protectionIP67
Durability *1Mechanical10,000,000 operations min.
Electrical200,000 operations min. (1 A at 125 VAC, resistive load)
Operating speed0.1 mm/s to 0.5 m/s (in case of plunger) 
1 mm/s to 1 m/s (in case of roller lever)
Operating 
frequency
Mechanical120 operations/min
Electrical30 operations/min
Rated frequency50/60 Hz
Insulation resistance100 MΩ min. (at 500 VDC)
Contact resistance (initial)100 mΩ max.
Dielectric 
strength
Between terminals of same polarity1,000 VAC, 50/60 Hz for 1 min
Between current-carrying metal 
parts and ground
1,500 VAC, 50/60 Hz for 1 min
Between each termi-nal and non- 
current-carrying metal part
1,500 VAC, 50/60 Hz for 1 min
Vibration 
resistance
Malfunction10 to 55 Hz, 1.5-mm double amplitude *2
Shock 
resistance
Destruction1,000 m/s2 max.
Malfunction500 m/s2 max. *2
Ambient operating temperature-10°C to 70°C (with no icing)
Ambient operating humidity35% to 95%RH
WeightApprox. 120 g (in the case of D4CC-1002)
 

View Complete Details

Yes, I am interested!

Small Limit Switch D4V
Interested in this product?
Get Best Quote

Small Limit Switch D4V

Get Latest Price

Specifications:

Certified Standards

 

Certification bodyStandardFile No.
CCCGB14048.5Consult your OMRON representative for details.
UL *UL508, CSA C22.2 No. 14
TÜVIEC60947-5-1

 

* Certification equivalent to CSA C22.2 No. 14 has been obtained from UL.

Ratings

 

Rated voltage 
(V)
Non-inductive load (A)Inductive load (A)
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125 VAC 
250 VAC

5
1.5 
1
0.7 
0.5

3

1.5

0.8
12 VDC 
24 VDC

5

3

4

3
125 VDC 
250 VDC
0.4 
0.4
0.2 
0.2
--- 
---
--- 
---
--- 
---

 

 

Note: 1. The above current ratings are for steady-state current. 
           2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 
           3. Lamp load has an inrush current of 10 times the steady-state current. 
           4. Motor load has an inrush current of 6 times the steady-state current.

 

 

Inrush currentNC24 A max.
NO12 A max.
 

View Complete Details

Yes, I am interested!

General-Purpose Limit Switch HL-5000
Interested in this product?
Get Best Quote
Specifications:

Ratings

 

Rated voltageNon-inductive load (A)Inductive load (A)
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125 VAC
250 VAC
5
5
1.5
1
0.7
0.5
3
3
2
1.5
1
0.8
12 VDC
24 VDC
125 VDC
250 VDC
5
5
3
3
4
4
3
3
0.4
0.4
0.2
0.2
---

 

Note:Note: 
1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.

 

Inrush currentNC24 A max.
NO12 A max.

 

Characteristics

 

Degree of protectionIP65
Durability *Mechanical10,000,000 operations min. (under rated conditions)
ElectricalSee the following Electrical Durability.
Operating speed5 mm/s to 0.5 m/s
Operating frequencyMechanical120 operations/min
Electrical30 operations/min
Insulation resistance100 MΩ min. (at 500 VDC)
Contact resistance25 mΩ max. (initial value)
Dielectric strength1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground
1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal part
Rated frequency50/60 Hz
Vibration resistanceMalfunction10 to 55 Hz, 1.5-mm double amplitude
Shock resistanceDestruction1,000 m/s2 max.
Malfunction300 m/s2 max.
Ambient operating temperature-5°C to 65°C (with no icing)
Ambient operating humidity35% to 95%RH
WeightApprox. 130 to 190 g
 

View Complete Details

Yes, I am interested!

General-purpose Limit Switch D4A-N
Interested in this product?
Get Best Quote
Specifications:

Ratings

 

TypeRated voltageNon-inductive load (A)Inductive load (A)
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
SPDT double-break 
(with/without indicator)
125 VAC *
250 VAC *
480 VAC
600 VAC
10
10
10
3
10
10
10
1
3
2
1.5
1
1.5
1
0.8
0.5
10
10
3
1.5
5
3
1.5
1
2.5
1.5
0.8
0.5
8 VDC
14 VDC
30 VDC
125 VDC *
250 VDC *
10
10
6
0.8
0.4
6
6
4
0.2
0.1
3
3
3
0.2
0.1
10
10
6
0.8
0.4
6
6
4
0.2
0.1
DPDT double-break 
(without indicator)
125 VAC
250 VAC
480 VAC
600 VAC
5
3
1.5
1
2
1
0.5
0.4
4
2
1
0.7
3
1.5
0.8
0.5
14 VDC
30 VDC
125 VDC
250 VAC
5
3
0.4
0.2
2
1
0.1
0.05
4
2
0.4
0.2
3
1.5
0.1
0.05
DPDT double-break 
(with in-dicator)
125 VAC
250 VAC
5
3
2
1
4
2
3
1.5
12 VDC
24 VDC
48 VDC
5
3
1
------------
 

View Complete Details

Yes, I am interested!

Small Sealed Switch D4E-N
Interested in this product?
Get Best Quote
Specifications:

Ratings

 

Rated voltageStandard loadMicro load
Non-inductive load (A)Inductive load (A)Non-inductive load (A)
Resistive loadLamp loadInductive loadMotor loadResistive load
NCNONCNONCNONCNONCNO
125 VAC 
250 VAC
5 (1) 
5 (1)
1.5 (1) 
1.5 (1)
3 (1) 
3 (1)
2 (1) 
1
1 (1) 
0.5
0.1 
---
8 VDC 
14 VDC 
30 VDC 
125 VDC 
250 VDC
5 (1) 
5 (1) 
5 (1) 
0.5 
0.25
--- 
--- 
--- 
--- 
---
1.5 (1) 
1.5 (1) 
1.5 (1) 
0.05 
0.03
--- 
--- 
--- 
--- 
---
0.1 
0.1 
0.1 
--- 
---

 

 

Minimum applicable loadStandard loadMicro load
160 mA at 5 VDC1 mA at 5 VDC

 

 

Inrush currentNC10 A max.
NO10 A max.
 

View Complete Details

Yes, I am interested!

Enclosed Switch SHL
Interested in this product?
Get Best Quote

Enclosed Switch SHL

Get Latest Price

Specifications:

Ratings

 

Rated voltageNon-inductive load (A)Inductive load (A)
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125 VAC
250 VAC
480 VAC
10
10
2
1.5
1.5
-
3
2
-
2.5
1.5
-
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
10
10
5
0.4
0.2
2
2
1.5
0.4
0.2
5
5
1.5
0.05
0.03
2
2
1.5
0.05
0.05

 

 

Inrush currentNC15 A max.
NO15 A max.

 

Note:Note:

Note:The above figures are for steady-state currents.

Note:Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).

Note:Lamp load has an inrush current of 10 times the steady-state current.

Note:Motor load has an inrush current of 6 times the steady-state current.

Micro load models

 

Rated voltageNon-inductive load (A)
Resistive load
NCNO
125 VAC0.1
8 VDC
14 VDC
30 VDC
0.1
0.1
0.1
 

View Complete Details

Yes, I am interested!

Enclosed Switch SHL ZC-55
Interested in this product?
Get Best Quote
Specifications:

Ratings

 

Rated voltageNon-inductive load (A)Inductive load (A)
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125 VAC
250 VAC
480 VAC
10
10
2
1.5
1.5
-
3
2
-
2.5
1.5
-
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
10
10
5
0.4
0.2
2
2
1.5
0.4
0.2
5
5
1.5
0.05
0.03
2
2
1.5
0.05
0.05

 

 

Inrush currentNC15 A max.
NO15 A max.

 

Note:Note:

Note:The above figures are for steady-state currents.

Note:Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).

Note:Lamp load has an inrush current of 10 times the steady-state current.

Note:Motor load has an inrush current of 6 times the steady-state current. 

View Complete Details

Yes, I am interested!

Enclosed Switch D4MC
Interested in this product?
Get Best Quote

Enclosed Switch D4MC

Get Latest Price

Specifications:

Ratings

 

Rated voltageNon-inductive load (A)Inductive load (A)
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125 VAC
250 VAC
480 VAC
10
10
3
3
2.5
1.5
1.5
1.25
0.75
10
10
2.5
5
3
1.5
2.5
1.5
0.75
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
10
10
6
0.5
0.25
3
3
3
0.4
0.2
1.5
1.5
1.5
0.4
0.2
6
6
5
0.05
0.03
5
5
5
0.05
0.03
2.5
2.5
2.5
0.05
0.03

 

 

Inrush currentNC30 A max.
NO15 A max.

 

Note:Note:

Note:The above figures are for steady-state currents.

Note:Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).

Note:Lamp load has an inrush current of 10 times the steady-state current.

Note:Motor load has an inrush current of 6 times the steady-state current.

Note:The above ratings were tested under the following conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%RH

(3) Operating frequency: 20 operations/min 

View Complete Details

Yes, I am interested!

Enclosed Switches ZE / ZV / ZV2 / XE / XV / XV2
Interested in this product?
Get Best Quote
Specifications:

Ratings

 

ModelRated voltageNon-inductive load (A)Inductive load (A)
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
ZE-[]
ZV-[]
ZV2-[]
125 VAC
250 VAC
480 VAC
15
15
10
3
2.5
1.5
1.5
1.25
0.75
15
15
6
5
3
1.5
2.5
1.5
0.75
125 VDC
250 VDC
0.5
0.25
0.5
0.25
0.05
0.03
0.05
0.03
XE-[]
XV-[]
XV2-[]
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
10
10
10
10
3
3
3
3
3
1.5
1.5
1.5
1.5
1.5
0.75
10
10
10
7.5
2
10
10
10
6
1.5
5
5
5
2
2
2.5
2.5
2.5
2.5
1.5

 

 

Inrush currentNC30 A max.
NO15 A max.

 

Note:Note:

Note:The above figures are for standard currents.

Note:Inductive loads have a power factor of 0.4 min.(AC) and a time constant of 7 ms max. (DC).

Note:Lamp load has an inrush current of 10 times the steadystate current.

Note:Motor load has an inrush current of 6 times the steady-state current 

View Complete Details

Yes, I am interested!

High-Precision Switch D5A
Interested in this product?
Get Best Quote
Specifications:

Ratings

 

ItemElectrical ratings
Contact output modelsM5, M8, M16 Type: 10 mA at 24 VAC, 10 mA at 12 VDC
Solid-state output models100 mA at 5 to 24 VDC ± 10%
Leakage current: 0.15 mA max.
Residual voltage: 3 V max.
Power consumption: 3 mW max.

 

Characteristics

 

Degree of protectionD5A-1[], D5A-2[]: IP40
Other than the above models: IP67
Repeat accuracy *1M5 (D5A-1[][][] series), M8, slim type:1 μm max.
M5 (D5A-2[][][] series), M16, limit type:3 μm max.
Durability *2Mechanical10,000,000 operations min.
Electrical1,000,000 operation min. (Contact output models: 24 VAC, 10 mA, resistive load,
Solid-state output models: 24 VAC, 100 mA, resistive load)
Deviation in electrical durability
after 1,000,000 operations
M5, M8, M16, slim type: 10 μm max.
Limit type: 20 μm max.
Operating speed1 μm/s to 0.5 m/s
Rated frequency50/60 Hz
Insulation resistance100 MΩ min. (at 250 VDC) between each terminal and non-current-carrying metal part
Contact resistance
(Initial value) *4
800 mΩ max. (initial) with 1 m cable,
2.4 Ω max. (initial) with 3 m cable,
4 Ω max. (initial) with 5 m cable
Dielectric strength1,000 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal part
Vibration
resistance
Malfunction10 to 55 Hz, 1.5-mm double amplitude
Shock
resistance
Mechanical1,000 m/s2 max.
Malfunction300 m/s2 max.
Temperature coefficient *3M5, M8, slim type: ± 20 × 10-6/ ° C max.
M16 type: ± 40 × 10-6/ ° C max.
Limit type: ± 50 × 10-6/ ° C max.
Ambient operating temperature-20°C to 75°C (with no icing)
Ambient operating humidity35% to 85% RH (35% to 95% RH with the seal rubber)
 

View Complete Details

Yes, I am interested!

High-Precision Optical Switch D5F
Interested in this product?
Get Best Quote
Specifications:

 
Ratings

 

Power supply voltage12 to 24 VDC ± 10%, ripple (p-p): 10% max.
Output current100 mA max.
Power consumption30 mA max.
Leakage current0.15 mA max.
Residual voltage2 V max.

 


Degree of protectionIP67
Durability *1Mechanical5,000,000 operations min.
Electrical
Operating speed1 μm/s to 0.5 m/s
Max. operating frequency60 operations/minute max.
Insulation resistance100 MΩ min. (at 500 VDC) between each terminal and non-current-carrying metal part
Dielectric strength (50/60Hz 1min)1,100 VAC between each terminal and non-current-carrying metal part
Vibration resistanceMalfunction10 to 500 Hz, 1.3-mm double amplitude
Shock resistanceMalfunction300 m/s2 max.
Repeat accuracy1 μm max. *2
Ambient temperature *3Operating: -10 ° C to 60 ° C (with no icing)
Ambient humidityOperating: 35% to 95%RH
WeightSwitch body: Approx. 50 g; Cord: Approx. 23 g/m
Characteristics

 

View Complete Details

Yes, I am interested!

Mechanical Touch Switch D5B
Interested in this product?
Get Best Quote
Specifications:

Ratings

 

Electrical ratings1 mA at 5 VDC to 30 mA at 30 VDC (resistive load)

 

Characteristics

 

Degree of protectionIP67
Durability *1Mechanical10,000,000 operations min.
Electrical5,000,000 operations min. (at 30 mA 30 VDC resistive load)
Operating speed5 to 500 mm/s
Operating
frequency
Mechanical120 operations/min.
Electrical60 operations/min.
Insulation resistance100 MΩ min. at 250 VDC between each terminal and non-current-carrying metal parts
Contact resistanceWith 1 m cable:700 mΩ max. (initial value)
With 3 m cable:1.9 Ω max. (initial value)
With 5 m cable:3.1 Ω max. (initial value)
Dielectric
strength
(50/60 Hz
1 min)
Between terminals of
same polarity
250 VAC (at TTP)
Between each terminal
and non-current-
carrying metal parts
1,000 VAC (600 VAC for M5 model)
Vibration
resistance
Malfunction10 to 55 Hz, 1.5-mm double amplitude *2
Shock
resistance
Mechanical1,000 m/s2 max.
Malfunction300 m/s2 max. *3
Ambient operating temperature-10°C to 70°C (with no icing)
Ambient operating humidity35% to 95% RH
Actuator strength14.7 N *4
WeightSwitchM5: Approx. 14 g, M8: Approx. 20 g, M10: Approx. 21 g
CableApprox. 10 g/m
 

View Complete Details

Yes, I am interested!

Touch Switch D5C
Interested in this product?
Get Best Quote

Touch Switch D5C

Get Latest Price

Specifications:

Ratings and Specifications

 

TypeDCAC
ModelD5C-1D[]0D5C-1A[]0
Degree of protectionEquivalent to IP67
Mechanical durability10,000,000 operations min. (at rated overtravel value)
Supply voltage 
(operating voltage)
12 to 24 VDC (10 to 30 VDC), (ripple: 
10% max.)
100 to 240 VAC (45 to 264 VAC), 
50/60 Hz
Rated frequency---50/60 Hz
Sensitivity setting range30 to 100 pF
Current consumption17 mA max.---
Leakage 
current
Circuit---2 mA max.
Antenna1 mA max.1 mA max.
Response time2 ms max.8 ms max.
Output current200 mA max. (resistive load)
Insulation resistance50 MΩ min. (at 500 VDC) between lead wires and case
Dielectric strength1,000 VAC, 50/60 Hz for 1 min between 
current-carrying metal parts and non- 
current-carrying metal parts
2,000 VAC, 50/60 Hz for 1 min between 
current-carrying metal parts and non- 
current-carrying metal parts
Rated insulation voltage (Ui)1,000 VAC
Pollution degree 
(operating environment)
3 (IEC947-5-1)
Protection against electric 
shock
Class II
Proof tracking index (PTI)175
Switch categoryD (IEC335)
Vibration resistance10 to 55 Hz, 1.5-mm double amplitude
Shock resistance1,000 m/s2 max.
Ambient temperatureOperating: -25°C to 70°C (with no icing)
Ambient humidity35% to 95% RH
WeightApprox. 110 g (in case of D5C-1DS0)Approx. 120 g (in case of D5C-1AS0)
 

View Complete Details

Yes, I am interested!

Limit Touch Switch NL
Interested in this product?
Get Best Quote

Limit Touch Switch NL

Get Latest Price

Specifications:

ModelNL1NL2NL3
Degree of protectionIP60
Supply voltage12 VDC24 VDC100 VAC or 200 VAC
Rated frequency---50/60 Hz
SensitivityGrounded object: Contact resistance of 3 kΩ max. 
Non-grounded object: Antenna-to-ground capacitance of 100 pF min.
Current consumption8 mA15 mA---
Leakage current---Circuit: 2 mA; Antenna: 1 mA *1
Response time5 ms max.20 ms max.
Output signalVoltage output model: 30 
mA at 12 VDC with output 
impedance of 4.7 kΩ
Current output model: 
24 VDC (directly 
switching resistive load 
of 170 mA max.)
Thyristor output model: 100 or 200 
VAC (directly switching resistive load 
of 30 to 300 mA) *2
Insulation resistance0 V (blue lead wire) is connected to casing100 MΩ min. at 500 VDC *3
Dielectric strength0 V (blue lead wire) is connected to casing1,500 VAC at 50/60 Hz for 1 min *3
Pollution degree 
(operating environment)
3 (IEC947-5-1)
Protection against 
electric shock
Class II
Proof tracking index 
(PTI)
175
Switch categoryD (IEC335)
Vibration resistance10 to 55 Hz, 1.5-mm double amplitude
Shock resistance200 m/s2 max.
Ambient temperature-10°C to 60°C (with no icing)
Ambient humidity35% to 95%RH
WeightApprox. 370 g (NL[]-C, -P) Approx. 550 g (NL[]-S) Approx. 680 g (NL[]-SP, -SC)
 

View Complete Details

Yes, I am interested!

Multiple Limit Switch VB
Interested in this product?
Get Best Quote

Multiple Limit Switch VB

Get Latest Price

Specifications:

Characteristics

 

Degree of protectionIP67
Durability *Mechanical5,000,000 operations min.
Electrical300,000 operations min. (10 A at 250 VAC, resistive load)
Operating speed0.1 mm to 0.5 m/s
Operating
frequency
Mechanical120 operations min.
Electrical30 operations min.
Rated frequency50/60 Hz (AC)
Insulation resistance100 MΩ min. (at 500 VDC)
Contact resistance15 mΩ max. (initial value)
Dielectric
strength
Between terminals of same polarity1,000 VAC/Uimp 4,000 VAC
Between current-carrying metal parts
and ground
1,500 VAC/Uimp 4,000 VAC
Between each terminal and non-
current-carrying metal part
1,500 VAC/Uimp 4,000 VAC
Between terminals of different polarityUimp 4 kV (EN60947-5-1)
Rated insulation voltage (Ui)300 VAC (EN60947-5-1)
Switching overvoltage1,000 V max. (EN60947-5-1)
Pollution degree (operating environment)3 (EN60947-5-1)
Short-circuit protective device (SCPD)10 A fuse type gG or gI (IEC269)
Conditional short-circuit current100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe)5 A, 0.5 A (EN60947-5-1)
Protection against electric shockInsulation class I (Use the grounding terminal or ground on the machine side.)
Vibration
resistance
Malfunction10 to 55 Hz, 1.5-mm double amplitude
Shock
resistance
Destruction1,000 m/s2 min.
Malfunction200 m/s2 min.
Ambient operating temperature-10°C to 80°C (with no icing)
Ambient operating humidity35% to 95%
WeightApprox. 580 g (in the case of VB-4211)
 

View Complete Details

Yes, I am interested!

Limit Switch Connectors SC
Interested in this product?
Get Best Quote
Connectors (SC Series)

Cabtire cables and flexible tubes with various diameters are used to connect machine tools and controllers with Limit Switches. To ensure the watertightness of the edges of the conduits, use an SC Connector that is suitable for the external diameter of cable and model of Limit Switch.

SC-[]F[] FA Connectors

The SC-[]F[] is a snap-on connecting model that greatly reduces the time-consuming effort for wiring the Limit Switch. The SC-[]F[] is easily and quickly connected or disconnected and its degree of protection is IP67.

View Complete Details

Yes, I am interested!

On-Site Flexible Rod Switch TP70
Interested in this product?
Get Best Quote
Specifications:

Approved Standards

 

AgencyStandardFile No.
CCC (CQC)GB14048.52013010305630190

 

Approved Standard RatingsCCC (GB14048.5)

 

Applicable category and ratings
AC-15 3A/240V
DC-13 0.27A/250V

 

Ratings

 

Rated voltageCarry currentCurrent (A)Volt-amperes (V)
MakeBreakMakeBreak
120 VAC
240 VAC
10 A60
30
6
3
7,200720
125 VDC
250 VDC
2.5 A0.55
0.27
0.55
0.27
6969

 

Characteristics

 

Degree of protection *1IP65
Vibration resistanceMalfunction: 10 to 55 Hz, 0.65-mm single amplitude, 100 m/s2 max.
Shock
resistance
Destruction1,000 m/s2 max.
Malfunction20 m/s2 max.
Operating
environment
Ambient operating temperature-10 ° C to 70 ° C
Ambient operating humidity35% to 95%RH
Built-in
switch
specifications
Switch modelD4N-2187
Allowable operating speed1 mm/s to 0.5 m/s
Allowable
operating
frequency
Mechanical60 operations/min
Electrical30 operations/min (with resistive load)
Durability *2Mechanical1,000,000 operations min.
Electrical200,000 operations min. (for a resistive load of 10 A at 125 VAC)
Contact typeSPST-NO SPST-NC
Terminal typeScrew terminals
Emergency-
stop switch
specifications
Switch modelA165E-M-02
Operating methodSlow action, Direct-opening mechanism
Operating functionsPush to lock, turn to reset
Contact is opened by pushing in switch and closed by returning switch to original position.
Contact typeDPST-NC
Operating partSize: 40 dia. Color: red, non-illuminated
Terminal typeSoldered terminals

View Complete Details