Have a requirement?
Get Best Price
Have a requirement?
Get Best Price
Products & Services
- Compact Non-Contact Door Switch D40z
- Compact Non-Contact Door Switch D40A / G9SX-NS
- Guard Lock Safety-Door Switch D4SL-N
- Guard Lock Safety-Door Switch D4NL
- Guard Lock Safety-Door Switch/Slide key D4JL
- Safety-Door Switch D4NS
- Slim Safety Door Switch D4GS-N
- Safety-Door Hinge Switch D4NH
- Safety-Door Switch D4BS
- Guard Lock Safety-Door Switch D4BL
- Guard Lock Safety-Door Switch/Slide key D4GL
- Safety Limit Switch D4N
- Small Safety Limit Switch D4F
- Safety Limit Switch D4B-N
- Pull-Reset Safety Limit Switch D4N-R
- Emergency Stop Switch A165E
- Emergency Stop Switch A22E
- Enabling Grip Switch
- Enabling Switch
- Relays With Forcibly Guided Contacts G7SA
- Power Relays
- Relays with Forcibly Guided Contacts G7S--E
- Safety Relay Unit G9SE
- Safety CPU Unit NX-SL
- Safety Controller G9SP
- Flexible Safety Unit G9SX
- Standstill Monitoring Unit
- Low-speed Monitoring Unit G9SX-LM
- Safety Guard Switching Unit G9SX-GS
- Safety Relay Unit
- Safety Relay Unit G9SB
- Safety Network Controller NE1A-SCPU Series
- Safety Network Controller NE1A-SCPU0-EIP
- EtherNet/IP-Device Net Router NE1A-EDR01
- Safety Network Controller NE0A-SCPU01
- Safety Interlock Switches ER
Safety Door Switches
Compact Non-Contact Door Switch D40z
Get Latest Price
Ratings and Characteristics (Non-contact Door Switch)
Model | D40Z-1C[] | |
---|---|---|
Operating characteristics | Operating distance (OFF --> ON) | 5 mm min. *1 |
Operating distance (ON --> OFF) | 15 mm max. *1 | |
Differential travel | 20% or less of operating distance at 23 °C (maximum 2.5mm) | |
Influence of temperature | 20% or less of operating distance at 23 °C within temperature range of -10 to 65 °C | |
Repeat accuracy | ±10% of operating distance at 23 °C | |
Response time (ON --> OFF) *2 | 25 ms max. | |
Operating time (OFF --> ON) *2 | 100 ms max. (Distance between the switch and actuator is 5 mm) | |
Ambient operating temperature | -10 to 65 °C (with no icing or condensation) | |
Ambient operating humidity | 25% to 85% | |
Insulation resistance (between charged parts and case) | 50 MΩ max. (at 500 VDC) | |
Dielectric strength (between charged parts and case) | 1,000 VAC for 1 min | |
Degree of contamination | 3 | |
Electromagnetic compatibility | IEC/EN 60497-5-3 compliant | |
Vibration resistance | 10 to 55 to 10 Hz (single amplitude: 0.75 mm, double amplitude: 1.5 mm) | |
Shock resistance | 300 m/s2 min. | |
Degree of protection | IP67 | |
Material | PBT resin | |
Mounting method | M4 screws | |
Terminal screw tightening torque | 1 Nm | |
Power supply voltage | 24 V DC 10%/-15% | |
Power consumption *3 | 0.5 W max. | |
Auxiliary monitoring output | Photocoupler output: 24 V DC, load current: 10 mA | |
LED indicators | Actuator not detected (lights in red); error occurred (blinks in red), actuator detected (lights in yellow), actuator detected and Non- contact Door Switch input OFF (blinks in yellow) | |
Connecting cables | 2 m, 5 m | |
Number of connectable switches *4 | 30 max. (wiring length: 100 m max.) | |
Weight | Switch: approx. 175 g, actuator: approx. 20 g (D40Z-1C5) |
View Complete Details
Compact Non-Contact Door Switch D40A / G9SX-NS
Get Latest Price
Non-contact Door SwitchesRatings and Characteristics
Model | D40A-1C[] | |
---|---|---|
Operating characteristics *1 | Operating distance OFF→ON | 5 mm min. *2 |
Operating distance ON→OFF | 15 mm max. *2 | |
Differential travel | 20% or less of operating distance at 23°C (maximum 2.5 mm) | |
Influence of temperature (max.) | ±20% of operating distance at 23°C, within temperature range of -10 to 55°C | |
Repeat accuracy | ±10% or less of operating distance at 23°C | |
Ambient operating temperature | -10 to 55°C (no icing or condensation) | |
Ambient operating humidity | 25% to 85% | |
Insulation resistance (between charged parts and case) | 50 MΩ max. (at 500 VDC) | |
Dielectric strength (between charged parts and case) | 1,000 VAC for 1 min | |
Pollution degree | 3 | |
Electromagnetic compatibility | IEC/EN 60497-5-3 compliant | |
Vibration resistance | 10 to 55 to 10 Hz (single amplitude: 0.75 mm, double amplitude: 1.5 mm) | |
Shock resistance | 300 m/s2 min. | |
Degree of protection | IP67 | |
Material | PBT resin | |
Mounting method | M4 screws | |
Terminal screw tightening torque | 1 N·m | |
Power supply voltage | 24 VDC 10%/-15% | |
Power consumption | 0.6 W max. | |
Auxiliary outputs *3 | 24 VDC, 10 mA (PNP open-collector outputs) | |
LED indicators | Actuator not detected (red); actuator detected (yellow) | |
Connection cables | 2 m, 5 m, 0.15 m (Connector type) | |
Number of connectable switches | 30 max. (wiring length: 100 m max.) *4 | |
Weight | Switch: approx. 145 g, actuator: approx. 20 g (D40A-1C2) |
View Complete Details
Guard Lock Safety-Door Switch D4SL-N
Get Latest Price
Standards and EC DirectivesConforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EMC Directive
• EN ISO 14119
• EN60204-1
• GS-ET-19
Certification body | Standard | File No. |
---|---|---|
TÜV SÜD | EN60947-5-1 (certified direct opening) | Consult your OMRON representative for details. |
UL *1 | UL508, CSA C22.2 No.14 | E76675 |
CQC (CCC) | GB14048.5 | 2012010305582059 |
KOSHA *2 | EN60947-5-1 | Consult your OMRON representative for details. |
*1. Certification has been obtained for UL CSA C22.2 No. 14.
*2. Only certain models have been certified.View Complete Details
Guard Lock Safety-Door Switch D4NL
Get Latest Price
Standards and EC DirectivesConforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EN ISO 14119
• EN 60204-1
• GS-ET-19
Certification body | Standard | File No. |
---|---|---|
TÜV SÜD | EN60947-5-1 (certified direct opening) | Consult your OMRON representative for details. |
UL *1 | UL508, CSA C22.2 No.14 | E76675 |
CQC (CCC) | GB14048.5 | 2003010305064267 |
KOSHA *2 | EN60947-5-1 | Consult your OMRON representative for details. |
*1. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
*2. Only certain models have been certified.
Certification body | Standard | File No. |
---|---|---|
TÜV SÜD | EN60947-5-1 (certified direct opening) | Consult your OMRON representative for details. |
KOSHA | EN60947-5-1 | Consult your OMRON representative for details. |
View Complete Details
Guard Lock Safety-Door Switch/Slide key D4JL
Get Latest Price
Standards and EC DirectivesConforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EN ISO 14119
• EN 60204-1
• GS-ET-19
• CCC
Certification body | Standard | File No. |
---|---|---|
TÜV SÜD *3 | EN 60947-5-1 (certified direct opening) | Consult your OMRON representative for details. |
UL *1 *3 | UL 508, CSA C22.2 No.14 | E76675 |
CQC (CCC) * | GB14048.5 | 2005010305167533 |
KOSHA *2 *3 | EN60947-5-1 | Consult your OMRON representative for details. |
*1. CSA C22.2 No. 14 was certified by UL.
*2. Only certain models have been certified.
*3. D4JL-[][]FA-[]8-01-SJ will be certificated soon.
Utilization category | AC-15 | DC-13 |
---|---|---|
Rated operating current (Ie) | 3 A | 0.27 A |
Rated operating voltage (Ue) | 240 V | 250 V |
View Complete Details
Safety-Door Switch D4NS
Get Latest Price
Standards and EC DirectivesConforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EN50047
• EN60204-1
• EN ISO 14119
• GS-ET-15
Certification body | Standard | File No. |
---|---|---|
TÜV SÜD | EN60947-5-1 (certified direct opening) | Consult your OMRON representative for details. |
UL *1 | UL508, CSA C22.2 No.14 | E76675 |
CQC (CCC) | GB14048.5 | 2003010305077330 |
KOSHA *2 | EN60947-5-1 | Consult your OMRON representative for details. |
*1. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
*2. Only certain models have been certified.
Utilization category | AC-15 | DC-13 |
---|---|---|
Rated operating current (Ie) | 3 A | 0.27 A |
Rated operating voltage (Ue) | 240 V | 250 V |
View Complete Details
Slim Safety Door Switch D4GS-N
Get Latest Price
Standards and EC DirectivesConforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EN ISO 14119
• EN60204-1
• GS-ET-15
Certification body | Standard | File No. |
---|---|---|
TÜV SÜD | EN60947-5-1 (certified direct opening) | Consult your OMRON representative for details. |
UL * | UL508 CSA C22.2 No. 14 | E76675 |
CQC (CCC) | GB14048.5 | 2003010305064262 |
* Certification for CSA C22.2 No. 14 is authorized by the UL mark.
Certified Standard RatingsTÜV (EN60947-5-1), CCC (GB14048.5)
Utilization category | AC-15 | DC-13 |
---|---|---|
Rated operating current (Ie) | 0.75 A | 0.27 A |
Rated operating voltage (Ue) | 240 V | 250 V |
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device.
UL/CSA (UL508, CSA C22.2 No. 14)C300
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC | 2.5 A | 15 | 1.5 | 1,800 | 180 |
240 VAC | 7.5 | 0.75 |
View Complete Details
Safety-Door Hinge Switch D4NH
Get Latest Price
Standards and EC DirectivesConforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EN50047
• EN60204-1
• EN ISO 14119
• GS-ET-15
Certification body | Standard | File No. |
---|---|---|
TÜV SÜD | EN60947-5-1 (certified direct opening) | Ask your OMRON representative for information on certified models. |
UL * | UL508, CSA C22.2 No.14 | E76675 |
CCC (CQC) | GB14048.5 | 2004010305105973 |
* Certification for CSA C22.2 No. 14 is authorized by the UL mark.
Certified Standard RatingsTÜV (EN60947-5-1)
Utilization category | AC-15 | DC-13 |
---|---|---|
Rated operating current (Ie) | 3 A | 0.27 A |
Rated operating voltage (Ue) | 240 V | 250 V |
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built
into the Switch.
UL/CSA (UL508, CSA C22.2 No. 14)A300
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC | 10 A | 60 | 6 | 7,200 | 720 |
240 VAC | 30 | 3 |
View Complete Details
Safety-Door Switch D4BS
Get Latest Price
Standards and EC DirectivesConforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN50041
EN ISO 14119
Certification body | Standard | File No. |
---|---|---|
TÜV Rheinland | EN60947-5-1 (certified direct opening) GS-ET-15 | Consult your OMRON representative for details. |
UL | UL508 | E76675 |
CSA | CSA C22.2 No. 14 | LR45746 |
CQC (CCC) | GB14048.5 | 2003010305073833 |
Certified Standard RatingsTÜV (EN60947-5-1), CCC (GB14048.5)
Utilization category | AC-15 |
---|---|
Rated operating current (Ie) | 0.75 A |
Rated operating voltage (Ue) | 240 V |
Note: Use a 10 A fuse type a gI or gG that conforms to IEC60269 as a short-circuit protection device.
UL/CSA (UL508, CSA C22.2 No. 14) (A600)
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC 240 VAC 480 VAC 600 VAC | 10 A | 60 30 15 12 | 6 3 1.5 1.2 | 7,200 | 720 |
View Complete Details
Guard Lock Safety-Door Switch D4BL
Get Latest Price
Standards and EC DirectivesConforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN ISO 14119
Certification body | Standard | File No. |
---|---|---|
TÜV Rheinland | EN60947-5-1 (certified direct opening) GS-ET-19 | Consult your OMRON representative for details. |
UL | UL508 | E76675 |
CSA | CSA C22.2, No.14 | LR45746 |
CQC (CCC) | GB14048.5 | 2003010305073836 |
Certified Standard RatingsTÜV (EN60947-5-1), CCC (GB14048.5)
Type | Standard model | Indicator model |
---|---|---|
Utilization category | AC-15 | AC-15 |
Rated operating current (Ie) | 3 A | 6 A |
Rated operating voltage (Ue) | 250 V | 115 V |
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device.
UL/CSA (UL508, CSA C22.2 No. 14)A300
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC 240 VAC | 10 A | 60 30 | 6 3 | 7,200 | 720 |
View Complete Details
Guard Lock Safety-Door Switch/Slide key D4GL
Get Latest Price
Standards and EC DirectivesConforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EN1088
• EN60204-1
• GS-ET-19
Certification body | Standard | File No. |
---|---|---|
TÜV SÜD | EN60947-5-1 (certified direct opening) | Consult your OMRON representative for details. |
UL *1 | UL508, CSA C22.2 No.14 | E76675 |
CQC (CCC) | GB14048.5 | 2003010305064264 |
KOSHA *2 | EN 60947-5-1 | Consult your OMRON representative for details. |
*2. Only certain models have been certified.
Metallic release key type
Certification body | Standard | File No. |
---|---|---|
TÜV SÜD | EN60947-5-1 (certified direct opening) | Consult your OMRON representative for details. |
KOSHA | EN 60947-5-1 | Consult your OMRON representative for details. |
Certified Standard RatingsTÜV (EN60947-5-1), CCC (GB14048.5)
Utilization category | AC-15 | DC-13 |
---|---|---|
Rated operating current (Ie) | 0.75 A | 0.27 A |
Rated operating voltage (Ue) | 240 V | 250 V |
View Complete Details
Safety Limit Switch D4N
Get Latest Price
Characteristics
Degree of protection *1 | IP67 (EN60947-5-1) | |
---|---|---|
Durability *2 | Mechanical | 15,000,000 operations min. *5 |
Electrical | 500,000 operations min. (3 A resistive load at 250 VAC) *3 300,000 operations min. (10 A resistive load at 250 VAC) | |
Operating speed | 1 to 500 mm/s (D4N-1120) | |
Operating frequency | 30 operations/minute max. | |
Contact resistance | 25 mΩ max. | |
Minimum applicable load *4 | 1 mA resistive load at 5 VDC (N-level reference value) | |
Rated insulation voltage (Ui) | 300 V | |
Rated frequency | 50/60 Hz | |
Protection against electric shock | Class II (double insulation) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Impulse withstand voltage (EN60947-5-1) | Between terminals of same polarity | 2.5 kV |
Between terminals of different polarity | 4 kV | |
Between each terminal and non- current carrying metallic parts | 6 kV | |
Insulation resistance | 100 MΩ min. | |
Contact gap | Snap-action: 2 × 0.5 mm min. Slow-action: 2 × 2 mm min. | |
Vibration resistance | Malfunction | 10 to 55 Hz, 0.75 mm single amplitude |
Shock resistance | Destruction | 1,000 m/s2 min. |
Malfunction | 300 m/s2 min. | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional free air thermal current (Ith) | 10 A (EN60947-5-1) | |
Ambient operating temperature | -30 to 70°C (with no icing) | |
Ambient operating humidity | 95% max. | |
Weight | Approx. 82 g (D4N-1120) Approx. 99 g (D4N-6120) |
View Complete Details
Small Safety Limit Switch D4F
Get Latest Price
Characteristics
Degree of protection *1 | IP67 (EN60947-5-1) | |
---|---|---|
Durability *2 | Mechanical | 10,000,000 times min. |
Electrical | 1,000,000 times min. (4 mA resistive load at 24 VDC, 4 circuits) 150,000 times min. (1 A resistive load at 125 VAC, 2 circuits/4 mA resistive load at 24 VDC, 2 circuits) *3 | |
Operating speed | 1 mm/s to 0.5 m/s | |
Operating frequency | Mechanical | 120 operations/minute |
Electrical | 30 operations/minute | |
Contact resistance *5 | 300 mΩ max. (with 1 m cable), 500 mΩ max. (with 3 m cable), 700 m Ωmax. (with 5 m cable) | |
Minimum applicable load *4 | 4 mA resistive load at 24 VDC, 4 circuits (N-level reference value) | |
Rated insulation voltage (Ui) | 250 V | |
Rated frequency | 50/60 Hz | |
Protection against electric shock | Class I (with a ground wire) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Impulse withstand voltage (EN60947-5-1) | Between terminals of same polarity | 2.5 kV |
Between terminals of different polarity | 4 kV | |
Between each terminal and ground | 4 kV | |
Insulation resistance | 100 MΩ min. (at 500 VDC) between terminals of the same polarities, between terminals of different polarities, between current-carrying metal parts and grounds, and between each terminal and non-current carrying metal parts | |
Contact gap | 2 × 2 mm min. | |
Vibration resistance | Malfunction | 10 to 55 Hz, 0.75 mm single amplitude |
Shock resistance | Destruction | 1,000 m/s2 min. |
Malfunction | 300 m/s2 min. | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional free air thermal current (Ith) | 2.5 A (EN60947-5-1) | |
Ambient operating temperature | - 30 to 70°C (with no icing) |
View Complete Details
Safety Limit Switch D4B-N
Get Latest Price
Standards and EC DirectivesConforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EN50041
• EN60204-1
• EN ISO 14119
Certification body | Standard | File No. |
---|---|---|
TÜV Rheinland | EN60947-5-1 (certified direct opening mechanism) GS-ET-15 | Consult your OMRON representative for details. |
EN60947-5-1 (uncertified direct opening mechanism) | J50005477 * | |
UL | UL508 | E76675 |
CSA | C22.2 No. 14 | LR45746 |
CQC (CCC) | GB14048.5 | 2003010305077612 |
* Adjustable roller lever, adjustable rod lever only.
Slow-action Mode
Certification body | Standard | File No. |
---|---|---|
TÜV Rheinland | EN60947-5-1 (certified direct opening mechanism) GS-ET-15 | Consult your OMRON representative for details. |
EN60947-5-1 (uncertified direct opening mechanism) | J50005477 * | |
UL | UL508 | E76675 |
CSA | C22.2 No. 14 | LR45746 |
CQC (CCC) | GB14048.5 | 2003010305077612 |
* Adjustable roller lever, adjustable rod lever only.
Certified Standard RatingsTÜV (EN60947-5-1), CCC (GB14048.5)
Utilization category | AC-15 |
---|---|
Rated operating current (Ie) | 2 A |
Rated operating voltage (Ue) | 400 V |
View Complete Details
Pull-Reset Safety Limit Switch D4N-R
Get Latest Price
Characteristics
Degree of protection *1 | IP67 (EN60947-5-1) | |
---|---|---|
Durability *2 | Mechanical | 1,000,000 operations min. |
Electrical | 500,000 operations min. (3 A resistive load at 250 VAC) *3 300,000 operations min. (10 A resistive load at 250 VAC) | |
Operating speed | 1 to 500 mm/s (D4N-1A20R) | |
Operating frequency | 30 operations/minute max. | |
Contact resistance | 25 mΩ max. | |
Minimum applicable load *4 | 1 mA resistive load at 5 VDC (N-level reference value) | |
Rated insulation voltage (Ui) | 300 V | |
Rated frequency | 50/60 Hz | |
Protection against electric shock | Class II (double insulation) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Impulse withstand voltage (EN60947-5-1) | Between terminals of same polarity | 2.5 kV |
Between terminals of different polarity | 4 kV | |
Between each terminal and non-current carrying metallic parts | 6 kV | |
Insulation resistance | 100 MΩ min. | |
Contact gap | 2 × 2 mm min. | |
Vibration resistance | Malfunction | 10 to 55 Hz, 0.75 mm single amplitude |
Shock resistance | Destruction | 1,000 m/s2 |
Malfunction | 300 m/s2 | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional free air thermal current (Ith) | 10 A (EN60947-5-1) | |
Ambient operating temperature | -30 to 70°C (with no icing) | |
Ambient operating humidity | 95% max. | |
Weight | Approx. 92 g (D4N-1A20R) |
View Complete Details
Emergency Stop Switch A165E
Get Latest Price
Switch RatingsModels with Separate Construction
Rated voltage | Resistive load |
---|---|
125 VAC 250 VAC 30 VDC | 5A 3A 3A |
Note: Minimum applicable load: 5 VDC, 150 mA
Models with One-piece Construction
Rated voltage | Resistive load |
---|---|
125 VAC 250 VAC 30 VDC | 1A 0.5A 1A |
Note: Minimum applicable load: 5 VDC, 1 mA
LED Ratings(Only for Models with LEDs)
Rated voltage | Rated current | Operation voltage |
---|---|---|
24 VAC/VDC | 8 mA | 24 VAC/VDC±5% |
Characteristics
Type | Emergency Stop Switch | |||
---|---|---|---|---|
Non-lighted A165E-S/A165E-M | Lighted A165E-LS/A165-LM | Non-lighted, One-piece construction A165E-U | ||
Allowable operating frequency | Mechanical | 20 operations/minute max. | ||
Electrical | 10 operations/minute max. | |||
Insulation resistance | 100 MΩ min. (at 500 VDC) | |||
Dielectric strength | Between terminals of same polarity | 1,000 VAC, 50/60 Hz for 1 min | ||
Between terminals of different polarity | 2,000 VAC 50/60 Hz for 1 min | |||
Between each terminal and ground | 2,000 VAC 50/60 Hz for 1 min | |||
Between lamp terminals | 1,000 VAC, 50/60 Hz for 1 min *1 | --- | ||
Vibration resistance | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms) |
View Complete Details
Emergency Stop Switch A22E
Get Latest Price
RatingsContacts (Standard Load)
Rated carry current (A) | Rated voltage (V) | Rated current (A) | |||
---|---|---|---|---|---|
AC15 (inductive load) | AC12 (resistive load) | DC13 (inductive load) | DC12 (resistive load) | ||
10 | 24 VAC | 10 | 10 | --- | --- |
110 VAC | 5 | 10 | |||
220 VAC | 3 | 6 | |||
380 VAC | 2 | 3 | |||
440 VAC | 1 | 2 | |||
24 VDC | --- | --- | 1.5 | 10 | |
110 VDC | 0.5 | 2 | |||
220 VDC | 0.2 | 0.6 | |||
380 VDC | 0.1 | 0.2 |
conducting tests under the following conditions.
(1) Ambient temperature: 20°±2°C
(2) Ambient humidity: 65±5%
(3)Operating frequency: 20 operations/minute
2. Minimum applicable load: 10 mA at 5 VDC
LED Indicators without Voltage Reduction Unit
Rated voltage | Rated current | Operating voltage |
---|---|---|
6 VAC/VDC | 8 mA | 6 VAC/VDC±5% |
12 VAC/VDC | 12 VAC/VDC±5% | |
24 VAC/VDC | 24 VAC/VDC±5% |
Characteristics
Type | Emergency Stop Switches | ||
---|---|---|---|
Non-lighted model: A22E | Lighted model: A22EL | ||
Allowable operating frequency | Mechanical | 30 operations/minute *3 | |
Electrical | 30 operations/minute *3 | ||
Insulation resistance | 100 MΩ min. (at 500 VDC) | ||
Dielectric strength | Between terminals of same polarity | 2,500 VAC, 50/60 Hz for 1 min | |
Between each terminal and ground | 2,500 VAC, 50/60 Hz for 1 min | ||
Vibration resistance *2 | 10 to 55 Hz, 1.5-mm double amplitude (within 1 ms) | ||
Shock resistance | Destruction | 1,000 m/s2 | |
Malfunction *2 | 250 m/s2 max. | ||
Durability | Mechanical | 300,000 operations min. *3 | |
Electrical | 300,000 operations min. *3 | ||
Ambient operating temperature *1 | -20 to 70°C | -20 to 55°C | |
Ambient operating humidity | 35% to 85% | ||
Ambient storage temperature | -40 to 70°C | ||
Degree of protection | IP65 (oil-resistant) *4 | IP65 *4 | |
Electric shock protection class | Class II | ||
PTI (tracking characteristic) | 175 | ||
Degree of contamination | 3 (EN60947-5-1) |
View Complete Details
Enabling Grip Switch
Get Latest Price
Ratings
Section | Enabling switch | Emergency stop switch (A4EG-BE2R041 only) | Pushbutton (A4EG-BM2B041 only) |
---|---|---|---|
Rated insulation voltage | 250 V | ||
Rated ON current | 2.5 A | 5 A | 0.1 A |
Rated load | 24 VDC, 0.3 A (inductive load) 125 VAC, 1 A (resistive load) EN certification rating: AC-15 0.75 A/240 V DC-13 0.55 A/125 V | General rating: 125 VAC, 5 A (resistive load) 250 VAC, 3 A (resistive load) 30 VDC, 3 A (resistive load) UL and cUL rating: 125 VAC, 5A (inductive load, power factor: 0.75 to 0.8) 250 VAC, 3 A (inductive load, power factor: 0.75 to 0.8) 30 VDC, 3 A (resistive load) EN certification rating: AC-12 3 A/250 V DC-12 3 A/30 V | General rating: 125 VAC, 0.1 A (resistive load) 8 VDC, 0.1 A (resistive load) 14 VDC, 0.1 A (resistive load) 30 VDC, 0.1 A (resistive load) UL and cUL rating: 125 VAC, 0.1 A (resistive load) 30 VDC, 0.1 A (resistive load) EN certification rating: AC-12 0.1 A/125 V DC-12 0.1 A/30 V |
Minimum applicable load | 24 VDC, 4 mA | 5 VDC, 1 mA |
View Complete Details
Enabling Switch
Get Latest Price
Ratings
Rated insulation voltage | 250 V |
---|---|
Rated ON current | 2.5 A |
Rated load | 24 VDC, 300 mA (inductive load) 125 VAC, 1 A (resistive load) |
Minimum applicable load | 24 VDC, 4 mA |
Impulse withstand voltage | 4.0 kV between terminals of different polarity, 2.5 kV between terminals of same polarity |
Ambient operating temperature | -10 to 55°C (with no icing) |
Ambient operating humidity | 35% to 85% (with no condensation) |
Ambient storage temperature | -25 to 65°C |
Characteristics
Insulation resistance | 100 MΩ min. (at 500 VDC) |
---|---|
Contact resistance | 100 mΩ max. (initial value) |
Vibration resistance | 10 to 55 Hz, 0.75-mm single amplitude min. |
Shock resistance | 150 m/s2 |
Mechanical durability | OFF-ON: 1,000,000 operations min. OFF-ON-OFF (direct opening): 100,000 operations min. |
Electrical durability | 100,000 operations min. |
Degree of protection | IP65 (rubber seal type only) |
View Complete Details
Relays With Forcibly Guided Contacts G7SA
Get Latest Price
RatingsCoil (4 poles)
Item | Rated current (mA) | Coil resistance (Ω) | Max. voltage (V) | Power consumption (mW) |
---|---|---|---|---|
Rated voltage | ||||
12 VDC | 30 | 400 | 110% | Approx. 360 |
18 VDC | 20 | 900 | ||
21 VDC | 17.1 | 1,225 | ||
24 VDC | 15 | 1,600 | ||
48 VDC | 7.5 | 6,400 |
Coil (6 poles)
Item | Rated current (mA) | Coil resistance (Ω) | Max. voltage (V) | Power consumption (mW) |
---|---|---|---|---|
Rated voltage | ||||
12 VDC | 41.7 | 288 | 110% | Approx. 500 |
18 VDC | 27.8 | 648 | ||
21 VDC | 23.8 | 882 | ||
24 VDC | 20.8 | 1,152 | ||
48 VDC | 10.4 | 4,606 |
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.
2. The maximum voltage is based on an ambient operating temperature of 23°C maximum.
Load | Resistive load |
---|---|
Rated load | 6 A at 250 VAC, 6 A at 30 VDC |
Rated carry current | 6 A |
Max. switching voltage | 250 VAC, 125 VDC |
Max. switching current | 6 A |
View Complete Details
Power Relays
Get Latest Price
RatingsCoil Ratings
Item | Rated current (mA) | Coil resistance (Ω) | Must operate voltage | Must release voltage | Maximum voltage | Power consumption (W) |
---|---|---|---|---|---|---|
Rated voltage | Percentage of rated voltage | |||||
12 VDC | 308 | 39 | 75% max. | 10% min. | 110% | Approx. 3.7 |
24 VDC | 154 | 156 |
Note: 1. Rated current and coil resistance were measured at a coil temperature of 23°C with coil resistance of ±15%.
2. Operating characteristics were measured at a coil temperature of 23°C.
3. The maximum allowable voltage is the maximum value of the fluctuation range for the Relay coil operating
power supply and was measured at an ambient temperature of 23°C.
There is, however, no continuous allowance.
Contact RatingsRelay
Model | G7Z-4A-[]Z, G7Z-3A1B-[]Z, G7Z-2A2B-[]Z | |||
---|---|---|---|---|
Load | Resistive load | Inductive load cosφ = 0.3 | Resistive load L/R = 1 ms | |
Contact structure | Double break | |||
Contact material | Ag alloy | |||
Rated load | NO | 40 A at 440 VAC | 22 A at 440 VAC | 5 A at 110 VDC |
NC | 25 A at 440 VAC | 10 A at 440 VAC | 5 A at 110 VDC | |
Rated carry current | NO | 40 A * | ||
NC | 25 A | |||
Maximum contact voltage | 480 VAC | 125 VDC | ||
Maximum contact current | NO | 40 A | 22 A | 5 A |
NC | 25 A | 10 A | 5 A | |
Maximum switching capacity | NO | 17,600 VA | 9,680 VA | 550 W |
NC | 11,000 VA | 4,400 VA | 550 W | |
Failure rate P value (reference value) | 2 A at 24 VDC |
View Complete Details
Relays with Forcibly Guided Contacts G7S--E
Get Latest Price
RatingsCoil
Rated voltage | Rated current (mA) | Coil resistance (Ω) | Max. voltage (V) | Power consumption (W) |
---|---|---|---|---|
24 VDC | 30 | 800 | 110% | Approx. 0.8 |
2. The maximum voltage is based on an ambient operating temperature of 23°C maximum.
Contacts
Load | Resistive load | |
---|---|---|
Rated load | NO contact | 10 A at 250 VAC 10 A at 30 VDC |
NC contact | 6 A at 250 VAC 6 A at 30 VDC | |
Rated carry current | NO contact | 10 A |
NC contact | 6 A | |
Maximum switching voltage | 250 VAC, 30 VDC | |
Maximum switching current | NO contact | 10 A |
NC contact | 6 A |
G7S-[]-E Characteristics of Sockets
Model | P7S-14F-END | P7S-14P-E |
---|---|---|
Continuous current | P7S-14P-E | |
Dielectric strength | 2000 VAC for 1 min. between terminals | |
Insulation resistance | 1000 MΩ min. * | |
Weight | Approx. 110g | Approx. 25g |
* Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC.
View Complete Details
Safety Relay Unit G9SE
Get Latest Price
RatingsPower Input
Model | G9SE-201 | G9SE-401 | G9SE-221-T[] |
---|---|---|---|
Rated supply voltage | 24 VDC | ||
Operating voltage range | -15% to 10% of rated supply voltage | ||
Rated power consumption *1 | 3 W max. | 4 W max. |
Outputs
Model | G9SE-201 | G9SE-401 | G9SE-221-T[] |
---|---|---|---|
Safety output OFF-delayed Safety output | Contact output 250 VAC 5 A 30 VDC 5 A (resistive load) | ||
Auxiliary output | PNP transistor output Load current: 100 mA DC max. |
Characteristics
Model | G9SE-201 | G9SE-401 | G9SE-221-T[] | ||
---|---|---|---|---|---|
Operating time (OFF to ON state) *2 | 100 ms Max. *3 | ||||
Response time (ON to OFF state) *4 | 15 ms Max. | ||||
Accuracy of OFF-delay time | - | Within plus or minus 10% of the set value | |||
Inputs | Input current | 5 mA Min. | |||
ON voltage | 11 VDC Min. | ||||
OFF voltage | 5 VDC Max. | ||||
OFF current | 1 mA Max. | ||||
Maximum cable length | 100 m Max. | ||||
Reset input time | 250 ms Min. | ||||
Contact outputs | Contact resistance *5 | 100 mΩ | |||
Mechanical durability | 5,000,000 operations Min. | ||||
Electrical durability | 50,000 operations Min. | ||||
Switching specification Inductive load (IEC/EN60947-5-1) | AC15: 240 VAC 2 A DC13: 24 VDC 1.5 A | ||||
Minimum applicable load | 24 VDC 4 mA | ||||
Conditional short-circuit current (IEC/EN60947-5-1) | 100A *6 | ||||
Pollution degree | 2 | ||||
Over voltage category (IEC/EN60664-1) | Safety output: Class III, the others: Class II | ||||
Insulation specification | Impulse withstand voltage (IEC/ EN60947-5-1) | Between input and output | 6 kV | ||
Between different poles of output | 6 kV (between 13-14/23-24 and 33-34/43-44 (37-38/47-48)) 4 kV (between 13-14 and 23-24, between 33-34 (37-38) and 43-44 (47-48)) | ||||
Dielectric strength | Between input and output | 2,200 VDC | |||
Between different poles of output | 1,500 VAC | ||||
Insulation resistance | 100 MΩ | ||||
Vibration resistance *7 | Frequency: 10 to 55 to 10 Hz Amplitude: 0.35 mm half amplitude (0.7 mm double amplitude) |
View Complete Details
Safety CPU Unit NX-SL
Get Latest Price
Regulations and Standards
Certification body | Standards |
---|---|
TÜV Rheinland * | EN ISO 13849-1: 2008 AC: 2009 EN ISO 13849-2: 2012 IEC 61508 parts 1-7: 2010 EN 62061: 2005 EN 61131-2: 2007 EN ISO 13850: 2008 EN 60204-1: 2006 A1: 2009 AC: 2010 EN 61000-6-2: 2005 EN 61000-6-4: 2007 NFPA 79: 2012 ANSI RIA 15.06-1999 ANSI B11.19-2010 UL1998 IEC 61326-3-1: 2008 |
UL | cULus: Listed (UL508) and ANSI/ISA 12.12.01 |
* Certification was received for applications in which OMRON FSoE devices are connected to each other.
The NX-series Safety Control Units allow you to build a safety control system that meets the following standards.
- Requirements for SIL 3 (Safety Integrity Level 3) in IEC 61508, EN 62061, Safety Standard for Safety Instrumented Systems (Functional Safety of Electrical/Electronic/Programmable Electronic Safety-related Systems)
- Requirements for PLe (Performance Level e) and for safety category 4 in EN ISO13849-1
General Specification
Item | Specification | |
---|---|---|
Enclosure | Mounted in a panel (open) | |
Grounding method | Ground to 100 Ω or less. | |
Operating environment | Ambient operating temperature | 0 to 55°C (The upper limit of the ambient operating temperature is restricted by the installation orientation.) |
Ambient operating humidity | 10% to 95% (with no condensation or icing) | |
Atmosphere | Must be free from corrosive gases. | |
Ambient storage temperature | -25 to 70°C (with no condensation or icing) | |
Altitude | 2,000 m max. | |
Pollution degree | 2 or less: Conforms to JIS B3502 and IEC 61131-2. | |
Noise immunity | Conforms to IEC 61131-2. 2 kV on power supply line (Conforms to IEC 61000-4-4.) | |
Insulation class | Class III (SELV) | |
Overvoltage category | Category II: Conforms to JIS B3502 and IEC 61131-2. | |
EMC immunity level | Zone B | |
Vibration resistance | Conforms to IEC 60068-2-6. 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m/s2, 100 minutes each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) | |
Shock resistance | Conforms to IEC 60068-2-27. 147 m/s2, 3 times each in X, Y, and Z directions | |
Insulation resistance | 20 MΩ between isolated circuits (at 100 VDC) |
View Complete Details
Safety Controller G9SP
Get Latest Price
G9SP SeriesGeneral Specifications
Power supply voltage | 24 VDC (20.4 to 26.4 VDC -15% 10%) |
---|---|
Current consumption * | G9SP-N10S: 400 mA (V1: 300 mA, V2: 100 mA) G9SP-N10D: 500 mA (V1: 300 mA, V2: 200 mA) G9SP-N20S: 500 mA (V1: 400 mA, V2: 100 mA) |
Isolation class | Class III (SELV) |
Overvoltage category | II |
Noise immunity | Conforms to IEC61131-2 |
Vibration resistance | 5 to 8.4 Hz: 3.5 mm, 8.4 to 150 Hz: 9.8 m/s2 |
Shock resistance | 147 m/s2: 11 ms |
Mounting | DIN track mounting (IEC60715 TH35-7.5/TH35-15) or M4 screws |
Ambient operating temperature | 0 to 55°C |
Ambient operating humidity | 10% to 90% (with no condensation) |
Ambient storage temperature | -20°C to 75°C |
Atmosphere | No corrosive gas |
Operating altitude | 2,000 m max. |
Pollution degree | Pollution degree 2 |
Degree of protection | IP20 except terminal blocks |
Terminal screws | M3 self-rising screws |
View Complete Details
Flexible Safety Unit G9SX
Get Latest Price
Ratings Power input
Model | G9SX-AD322-[]/ADA222-[] | G9SX-BC202-[] | G9SX-EX-[] |
---|---|---|---|
Rated supply voltage | 24 VDC | ||
Operating voltage range | -15% to 10% of rated supply voltage | ||
Rated power consumption * | 4 W max. | 3 W max. | 2 W max. |
Inputs
Model | G9SX-AD322-[]/ADA222-[] | G9SX-BC202-[] |
---|---|---|
Safety input | Operating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8 kΩ * | |
Feedback/reset input |
Outputs
Model | G9SX-AD322-[]/ADA222-[] | G9SX-BC202-[] |
---|---|---|
Instantaneous safety output *1 OFF-delayed safety output *1 | P channel MOS-FET output Load current: 0.8 A DC max./output *2 *3 | P channel MOS-FET output Load current: 0.8 A DC max./output *2 *3 |
Auxiliary output | PNP transistor output Load current: 100 mA max./output |
using the safety outputs as input signals to control devices (i.e. Programmable Controllers), consider the OFF pulse
shown below.
*2. The following derating is required when Units are mounted side-by-side.
G9SX-AD322-[]/G9SX-ADA222-[]/G9SX-BC202-[]: 0.4 A max. load current/output
*3. A load current below 1 A DC/output can be used when the following outputs are used.
G9SX-AD322-[]/G9SX-ADA222-[]: 2 outputs or less
G9SX-BC202-[]: 1 output
Expansion Unit Ratings
Model | G9SX-EX-[] |
---|---|
Rated load | 250 VAC, 3 A/30 VDC, 3 A (resistive load) |
Rated carry current | 3 A |
Maximum switching voltage | 250 VAC, 125 VDC |
View Complete Details
Standstill Monitoring Unit
Get Latest Price
RatingsPower input
Model | G9SX-SM032-[] |
---|---|
Rated supply voltage | 24 VDC |
Operating voltage range | -15% to 10% of rated supply voltage |
Power consumption * | 4 W max. |
* Power consumption of loads not included.
Inputs
Model | G9SX-SM032-[] |
---|---|
Rated Input voltage | Standstill detection input (between Z1 and Z2 and between Z3 and Z4) *1 480 VAC max. (120Hz max.) *2 |
Internal impedance | Standstill detection input: Approx. 660 kΩ EDM input: Approx. 2.8 kΩ *3 |
*1. Input the motor phase-to-phase voltage between Z1 and Z2 and between Z3 and Z4.
*2. When a motor with AC240V or more is used, connect neutral point of the power supply to earth.
*3. Use a contact that is applicable to microloads (24 VDC, 5 mA) for connection to the EDM input.
Model | G9SX-SM032-[] |
---|---|
Safety standstill detection output * 1 | Source output (PNP), load current: 0.3 A DC max. * 2 |
Auxiliary output (output monitor/error) | Source output (PNP), load current: 100 mA DC max. |
*1. While safety standstill detection outputs are in the ON state, the following pulse signal is output continuously for output
circuit diagnosis.
When using the safety standstill detection outputs as input signals to control devices (i.e. Programmable Controllers),
consider the pulse signal shown below.
*2. The following derating is required when Units are mounted side-by-side.
G9SX-SM032-[]: 0.2 A max. load current
View Complete Details
Low-speed Monitoring Unit G9SX-LM
Get Latest Price
RatingsPower input
Model | G9SX-LM224-[] | G9SX-EX401-[] |
---|---|---|
Rated supply voltage | 24 VDC | |
Operating voltage range | -15% to 10% of rated supply voltage | |
Power consumption * | 5 W max. | 2 W max. |
* Power consumption of loads not included.
Inputs
Model | G9SX-LM224-[] |
---|---|
Safety input Enabling input Feedback/reset input Mode selector input | Operating voltage: 20.4 VDC to 26.4 VDC Internal impedance: Approx. 2.8 kΩ * |
Rotation detection input | Operating voltage: 20.4 VDC to 26.4 VDC Internal impedance: Approx. 2.8 kΩ * Frequency input range: 1 kHz max. |
* Provide a current equal to or higher than that of the minimum applicable load of the connected input control device.
Outputs
Model | G9SX-LM224-[] |
---|---|
Safety instantaneous output *1 | Source output (PNP compatible) Load current: 0.8 A DC max. * 2 |
Safety speed detection output *1 | Source output (PNP compatible) Load current: 0.3 A DC max. |
Auxiliary output | Source output (PNP compatible) Load current: 100 mA DC max. |
*1. While safety instantaneous outputs and safety speed detection outputs are in the ON state, the following pulse signal
is output continuously for output circuit diagnosis.
When using these safety outputs as input signals to control devices (i.e. Programmable Controllers), consider the
pulse signal shown below.
View Complete Details
Safety Guard Switching Unit G9SX-GS
Get Latest Price
RatingsPower Input
Model | G9SX-GS226-T15-[] | G9SX-EX-[] |
---|---|---|
Rated supply voltage | 24 VDC | |
Operating voltage range | -15% to 10% of rated supply voltage | |
Rated power consumption * | 5 W max. | 2 W max. |
Inputs
Model | G9SX-GS226-T15-[] |
---|---|
Safety inputs | Operating voltage: 20.4 VDC to 26.4 VDC, Internal impedance: Approx. 2.8 kΩ * |
Mode selector input | |
Feedback/reset input |
Outputs
Model | G9SX-GS226-T15-[] |
---|---|
Instantaneous safety outputs *1 OFF-delayed safety outputs *1 | P channel MOS-FET outputs Load current: 0.8 A DC max./output *2 |
Auxiliary outputs (for input, output, and error monitoring) | PNP transistor outputs Load current: 0.8 A DC max./output *2 |
External indicator outputs | P channel MOS-FET outputs Connectable indicators • Incandescent lamp: 24 VDC, 3 to 7 W • LED lamp: 10 to 300 mA DC/output |
When using the safety outputs as input signals to control devices (i.e. Programmable Controllers), consider the OFF
pulse shown below.
View Complete Details
Safety Relay Unit
Get Latest Price
RatingsPower Input
Model | G9SA-301/TH301 | G9SA-501 | G9SA-321-T[] |
---|---|---|---|
Power supply voltage | 24 VAC/VDC: 24 VAC, 50/60 Hz, or 24 VDC 100 to 240 VAC: 100 to 240 VAC, 50/60 Hz | ||
Operating voltage range | 85% to 110% of rated power supply voltage | ||
Power consumption* | 24 VAC/VDC: 1.8 VA/1.7 W max. 100 to 240 VAC: 9 VA max. | 24 VAC/VDC: 2.8 VA/2.6 W max. 100 to 240 VAC: 11 VA max. | 24 VAC/VDC: 3.5 VA/3.3 W max. 100 to 240 VAC: 12.5 VA max. |
* When an Expansion Unit is connected, the power consumption is increased by 2 VA/2 W max.
Inputs
Model | G9SA-301/321-T[]/TH301 | G9SA-501 |
---|---|---|
Input current * | 40 mA max. | 60 mA max |
* When an Expansion Unit is connected, the input current is increased by 30 mA max.
Contacts
Model Load | G9SA-301/501/321-T[]/TH301/EX301/EX031-T[] |
---|---|
Resistive load | |
Rated load | 250 VAC, 5 A 30 VDC, 5 A |
Rated carry current | 5 A |
View Complete Details
Safety Relay Unit G9SB
Get Latest Price
RatingsPower Input
Model | G9SB-200[]-[] | G9SB-3010 | G9SB-301[]-[] |
---|---|---|---|
Power supply voltage | 24 VAC/VDC: 24 VAC, 50/60 Hz, or 24 VDC 24 VDC: 24 VDC | ||
Operating voltage range | 85% to 110% of rated power supply voltage | ||
Power consumption | 1.6 VA/1.4 W max. | 1.7 W max. | 2.0 VA/1.7 W max. |
Inputs
Model | G9SB-200[]-[] | G9SB-3010 | G9SB-301[]-[] |
---|---|---|---|
Input current | 25 mA max. | 60 mA max. * | 30 mA max. |
Contacts
Model Load | G9SB-200[]-[] | G9SB-3010 | G9SB-301[]-[] |
---|---|---|---|
Resistive load | |||
Rated load | 250 VAC, 5 A 30 VDC, 5 A | ||
Rated carry current | 5 A |
Characteristics
Model | G9SB-200[]-[] | G9SB-3010 | G9SB-301[]-[] | |
---|---|---|---|---|
Contact resistance *1 | 100 mΩ | |||
Operating time *2 | 30 ms max. | |||
Response time *3 | 10 ms max. | |||
Insulation resistance *4 | 100 MΩ min. (at 500 VDC) | |||
Dielectric strength | Between different outputs | 2,500 VAC, 50/60 Hz for 1 min | ||
Between inputs and outputs | ||||
Between power inputs and outputs | ||||
Vibration resistance | 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) | |||
Shock resistance | Destruction | 300 m/s2 | ||
Malfunction | 100 m/s2 | |||
Durability *5 | Mechanical | 5,000,000 operations min. (at approx. 7,200 operations/hr) | ||
Electrical | 100,000 operations min. (at approx. 1,800 operations/hr) | |||
Failure rate (P level) (reference value) | 5 VDC, 1 mA |
View Complete Details
Safety Network Controller NE1A-SCPU Series
Get Latest Price
Certified Standards
Certification body | Standard |
---|---|
TÜV Rheinland | NFPA 79-2012 EN ISO13849-1: 2006 IEC61508 part1-7: 2010 IEC61131-2:2007 EN ISO13849-2:2003 EN ISO 13850:2006 (EN418: 1992) EN61000-6-4:2007 EN61000-6-2:2005 EN60204-1:2006 ANSI RIA15.06-1999 ANSI B11.19-2010 |
UL | UL508 ANSI/ISA 12.12.01 UL1998 NFPA79 IEC61508 CSA22.2 No.142 CSA22.2 No.213 |
Specifications
Model | NE1A-SCPU01-V1 | NE1A-SCPU02 | |
---|---|---|---|
Communications power supply voltage | 11 to 25 VDC supplied via communications connector | ||
Internal circuit power supply voltage (V0) *1 | 20.4 to 26.4 VDC (24 VDC -15%/ 10%) | ||
I/O power supply voltage (V1, V2) *1 | |||
Current consumption | Communications power supply | 24 VDC, 15 mA | |
Internal circuit power supply | 24 VDC, 230 mA | 24 VDC, 280 mA | |
I/O power supply *2 | 24 VDC, 40 mA (Input) 120 mA (Output) | 24 VDC, 80 mA (Input) 150 mA (Output) | |
Overvoltage category | II | ||
Noise immunity | Conforms to IEC61131-2. | ||
Vibration resistance | 10 to 57 Hz: 0.35 mm, 57 to 150 Hz: 50 m/s2 | ||
Shock resistance | 150 m/s2: 11 ms | ||
Mounting method | DIN Track (IEC 60715 TH35-7.5/TH35-15) | ||
Ambient operating temperature | -10 to 55°C | ||
Ambient operating humidity | 10% to 95% (with no condensation) | ||
Ambient storage temperature | -40 to 70°C | ||
Degree of protection | IP20 | ||
Serial interface | USB version 1.1 | ||
Weight | 460 g max. | 690 g max. |
View Complete Details
Safety Network Controller NE1A-SCPU0-EIP
Get Latest Price
Certified Standards
Certification body | Standards |
---|---|
TÜV Rheinland | NFPA 79-2012 ISO13849-1: 2008 IEC61508 part1-7: 2010 IEC61131-2: 2007 EN ISO13849-2: 2012 EN61000-6-4: 2007 EN61000-6-2: 2005 EN60204-1: 2006 EN ISO13850: 2006 (EN418: 1992) ANSI RIA15.06-1999 ANSI B11.19-2012 |
UL | UL508 ANSI/ISA 12.12.01 UL1998 NFPA79 IEC61508 CSA22.2 No.142 CSA22.2 No.213 |
Specifications
Model | NE1A-SCPU01-EIP | NE1A-SCPU02-EIP | |
---|---|---|---|
DeviceNet communications power supply voltage | 11 to 25 VDC (Supplied via communications connector.) | ||
Unit power supply voltage (V0) *1 | 20.4 to 26.4 VDC (24 VDC -15%/ 10%) | ||
I/O power supply voltage (V1, V2) *1 | |||
Current consumption | Communications power supply | 24 VDC, 15 mA | |
Internal circuit power supply | 24 VDC, 280 mA | 24 VDC, 330 mA | |
I/O power supply *2 | 24 VDC, 40 mA (Input) 120 mA (Output) | 24 VDC, 80 mA (Input) 150 mA (Output) | |
Overvoltage category | II | ||
Noise immunity | Conforms to IEC61131-2. | ||
Vibration resistance | 10 to 57 Hz: 0.35 mm, 57 to 150 Hz: m/s2 | ||
Shock resistance | 150 m/s2: 11 ms | ||
Mounting method | DIN track mounting (IEC60715 TH35-7.5/TH35-15) | ||
Ambient operating temperature | -10 to 55°C | ||
Ambient operating humidity | 10% to 95% (with no condensation) | ||
Ambient storage temperature | -40 to 70°C | ||
Degree of protection | IP20 | ||
Serial interface | USB version 1.1 | ||
Weight | 570 g max. | 800 g max. |
*1. V0-G0: Internal control circuit
V1-G1 (G): For external input device, test output
V2-G2 (G): For external output device
*2. Not including power consumption for external devices.
View Complete Details
EtherNet/IP-Device Net Router NE1A-EDR01
Get Latest Price
Certified Standards
Certification body | Standard |
---|---|
UL | UL508, ANSI/ISA 12.12.01 CSA22.2 No.142, CSA22.2 No.213 |
Specifications
DeviceNet communications power supply voltage | 11 to 25 VDC (supplied via DeviceNet communications connector) | |
---|---|---|
Internal circuit power supply voltage | 20.4 to 26.4 VDC (24 VDC - 15%/ 10%) | |
Current consumption | DeviceNet communications power supply | 24 VDC, 15 mA |
Internal circuit power supply | 24 VDC, 230 mA | |
Overvoltage category | II | |
Noise immunity | Conforms to IEC 61131-2. | |
Vibration resistance | 10 to 57 Hz: 0.35 mm, 57 to 150 Hz: 50 m/s2 | |
Shock resistance | 150 m/s2: 11 ms | |
Mounting method | 35-mm DIN Track (IEC 60715 TH35-7.5/TH35-15) | |
Ambient operating temperature | - 10 to 55 ° C | |
Ambient operating humidity | 10 to 95% (with no condensation) | |
Ambient storage temperature | - 40 to 70 ° C | |
Degree of protection | IP20 | |
Weight | 220 g max. |
View Complete Details
Safety Network Controller NE0A-SCPU01
Get Latest Price
Certified Standards
Certification body | Standard |
---|---|
TÜV Rheinland | NFPA 79-2012 EN ISO13849-1: 2006 IEC61508 part1-7: 2010 IEC61131-2:2007 EN ISO13849-2:2003 EN ISO 13850:2006 (EN418: 1992) EN61000-6-4:2007 EN61000-6-2:2005 EN60204-1:2006 ANSI RIA15.06-1999 ANSI B11.19-2010 |
UL | UL508 ANSI/ISA 12.12.01 UL1998 NFPA79 IEC61508 CSA22.2 No.142 CSA22.2 No.213 |
Specifications
Communications power supply voltage | 11 to 25 VDC supplied via communications connector | |
---|---|---|
Internal circuit power supply voltage (V0) *1 | 20.4 to 26.4 VDC (24 VDC - 15%/ 10%) | |
I/O power supply voltage (V1, V2) *1 | ||
Current consumption | Communications power supply | 24 VDC, 15 mA |
Internal circuit power supply | 24 VDC, 110 mA | |
I/O power supply * 2 | 24 VDC, 80 mA (Input) 80 mA (Output) | |
Overvoltage category | II | |
Noise immunity | Conforms to IEC61131-2. | |
Vibration resistance | 10 to 57 Hz: 0.35 mm, 57 to 150 Hz: 50 m/s2 | |
Shock resistance | 150 m/s2 : 11 ms | |
Mounting method | DIN Track (IEC 60715 TH35-7.5/TH35-15) | |
Ambient operating temperature | - 10 to 55 ° C | |
Ambient operating humidity | 10% to 95% (with no condensation) | |
Ambient storage temperature | - 40 to 70 ° C | |
Degree of protection | IP20 | |
Serial I/F | USB version 1.1 | |
Weight | 440 g max. |
*1. V0-G0: Internal control circuit
V1-G1: For external input device, test output
V2-G2: For external output device
*2. Not including power consumption for external devices.
View Complete Details