Ratings and Characteristics (Non-contact Door Switch)

 

ModelD40Z-1C[]
Operating 
characteristics
Operating distance 
(OFF --> ON)
5 mm min. *1
Operating distance 
(ON --> OFF)
15 mm max. *1
Differential travel20% or less of operating distance at 23 °C (maximum 2.5mm)
Influence of 
temperature
20% or less of operating distance at 23 °C within temperature range of -10 to 65 °C
Repeat accuracy±10% of operating distance at 23 °C
Response time 
(ON --> OFF) *2
25 ms max.
Operating time 
(OFF --> ON) *2
100 ms max. (Distance between the switch and actuator is 5 mm)
Ambient operating temperature-10 to 65 °C (with no icing or condensation)
Ambient operating humidity25% to 85%
Insulation resistance (between charged 
parts and case)
50 MΩ max. (at 500 VDC)
Dielectric strength (between charged 
parts and case)
1,000 VAC for 1 min
Degree of contamination3
Electromagnetic compatibilityIEC/EN 60497-5-3 compliant
Vibration resistance10 to 55 to 10 Hz (single amplitude: 0.75 mm, double amplitude: 1.5 mm)
Shock resistance300 m/s2 min.
Degree of protectionIP67
MaterialPBT resin
Mounting methodM4 screws
Terminal screw tightening torque1 Nm
Power supply voltage24 V DC 10%/-15%
Power consumption *30.5 W max.
Auxiliary monitoring outputPhotocoupler output: 24 V DC, load current: 10 mA
LED indicatorsActuator not detected (lights in red); error occurred (blinks in red), 
actuator detected (lights in yellow), actuator detected and Non- 
contact Door Switch input OFF (blinks in yellow)
Connecting cables2 m, 5 m
Number of connectable switches *430 max. (wiring length: 100 m max.)
WeightSwitch: approx. 175 g, actuator: approx. 20 g (D40Z-1C5)

View Complete Details

Yes, I am interested!

Compact Non-Contact Door Switch D40A / G9SX-NS
Interested in this product?
Get Best Quote
Specifications:

Non-contact Door SwitchesRatings and Characteristics

 

ModelD40A-1C[]
Operating 
characteristics 
*1
Operating distance 
OFF→ON
5 mm min. *2
Operating distance 
ON→OFF
15 mm max. *2
Differential travel20% or less of operating distance at 23°C (maximum 2.5 mm)
Influence of 
temperature (max.)
±20% of operating distance at 23°C, within temperature range of -10 to 55°C
Repeat accuracy±10% or less of operating distance at 23°C
Ambient operating temperature-10 to 55°C (no icing or condensation)
Ambient operating humidity25% to 85%
Insulation resistance 
(between charged parts and case)
50 MΩ max. (at 500 VDC)
Dielectric strength 
(between charged parts and case)
1,000 VAC for 1 min
Pollution degree3
Electromagnetic compatibilityIEC/EN 60497-5-3 compliant
Vibration resistance10 to 55 to 10 Hz (single amplitude: 0.75 mm, double amplitude: 1.5 mm)
Shock resistance300 m/s2 min.
Degree of protectionIP67
MaterialPBT resin
Mounting methodM4 screws
Terminal screw tightening torque1 N·m
Power supply voltage24 VDC 10%/-15%
Power consumption0.6 W max.
Auxiliary outputs *324 VDC, 10 mA (PNP open-collector outputs)
LED indicatorsActuator not detected (red); actuator detected (yellow)
Connection cables2 m, 5 m, 0.15 m (Connector type)
Number of connectable switches30 max. (wiring length: 100 m max.) *4
WeightSwitch: approx. 145 g, actuator: approx. 20 g (D40A-1C2)
 

View Complete Details

Yes, I am interested!

Guard Lock Safety-Door Switch D4SL-N
Interested in this product?
Get Best Quote
Specifications:

Standards and EC DirectivesConforms to the following EC Directives:

• Machinery Directive 
• Low Voltage Directive 
• EMC Directive 
• EN ISO 14119 
• EN60204-1 
• GS-ET-19

Certified Standards

 

Certification bodyStandardFile No.
TÜV SÜDEN60947-5-1 (certified direct opening)Consult your OMRON representative for details.
UL *1UL508, CSA C22.2 No.14E76675
CQC (CCC)GB14048.52012010305582059
KOSHA *2EN60947-5-1Consult your OMRON representative for details.

 

*1. Certification has been obtained for UL CSA C22.2 No. 14. 

*2. Only certain models have been certified. 

View Complete Details

Yes, I am interested!

Guard Lock Safety-Door Switch D4NL
Interested in this product?
Get Best Quote
Specifications:

Standards and EC DirectivesConforms to the following EC Directives:

• Machinery Directive
• Low Voltage Directive
• EN ISO 14119
• EN 60204-1
• GS-ET-19

Certified StandardsStandard type

 

Certification bodyStandardFile No.
TÜV SÜDEN60947-5-1
(certified direct opening)
Consult your OMRON representative for details.
UL *1UL508, CSA C22.2 No.14E76675
CQC (CCC)GB14048.52003010305064267
KOSHA *2EN60947-5-1Consult your OMRON representative for details.

 

*1. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
*2. Only certain models have been certified.

Metallic release key type

 

Certification bodyStandardFile No.
TÜV SÜDEN60947-5-1
(certified direct opening)
Consult your OMRON representative for details.
KOSHAEN60947-5-1Consult your OMRON representative for details.

View Complete Details

Yes, I am interested!

Guard Lock Safety-Door Switch/Slide key D4JL
Interested in this product?
Get Best Quote
Specifications:

Standards and EC DirectivesConforms to the following EC Directives:

• Machinery Directive 
• Low Voltage Directive 
• EN ISO 14119 
• EN 60204-1 
• GS-ET-19 
• CCC

Certified Standards

 

Certification bodyStandardFile No.
TÜV SÜD *3EN 60947-5-1 
(certified direct opening)
Consult your OMRON representative for details.
UL *1 *3UL 508, CSA C22.2 No.14E76675
CQC (CCC) *GB14048.52005010305167533
KOSHA *2 *3EN60947-5-1Consult your OMRON representative for details.

 

*1. CSA C22.2 No. 14 was certified by UL. 
*2. Only certain models have been certified. 
*3. D4JL-[][]FA-[]8-01-SJ will be certificated soon.

Certified Standard RatingsTÜV (EN 60947-5-1)

 

Utilization categoryAC-15DC-13
Rated operating current (Ie)3 A0.27 A
Rated operating voltage (Ue)240 V250 V
 

View Complete Details

Yes, I am interested!

Safety-Door Switch D4NS
Interested in this product?
Get Best Quote

Safety-Door Switch D4NS

Get Latest Price

Specifications:

Standards and EC DirectivesConforms to the following EC Directives:

• Machinery Directive 
• Low Voltage Directive 
• EN50047 
• EN60204-1 
• EN ISO 14119 
• GS-ET-15

Certified Standards

 

Certification bodyStandardFile No.
TÜV SÜDEN60947-5-1 
(certified direct opening)
Consult your OMRON representative for details.
UL *1UL508, CSA C22.2 No.14E76675
CQC (CCC)GB14048.52003010305077330
KOSHA *2EN60947-5-1Consult your OMRON representative for details.

 

*1. Certification for CSA C22.2 No. 14 is authorized by the UL mark. 
*2. Only certain models have been certified.

Certified Standard RatingsTÜV (EN60947-5-1), CCC (GB14048.5)

 

Utilization categoryAC-15DC-13
Rated operating current (Ie)3 A0.27 A
Rated operating voltage (Ue)240 V250 V
 

View Complete Details

Yes, I am interested!

Slim Safety Door Switch D4GS-N
Interested in this product?
Get Best Quote
Specifications:

Standards and EC DirectivesConforms to the following EC Directives:

• Machinery Directive 
• Low Voltage Directive 
• EN ISO 14119 
• EN60204-1 
• GS-ET-15

Certified Standards

 

Certification bodyStandardFile No.
TÜV SÜDEN60947-5-1 
(certified direct opening)
Consult your OMRON 
representative for details.
UL *UL508 
CSA C22.2 No. 14
E76675
CQC (CCC)GB14048.52003010305064262

 

* Certification for CSA C22.2 No. 14 is authorized by the UL mark.

Certified Standard RatingsTÜV (EN60947-5-1), CCC (GB14048.5)

 

Utilization categoryAC-15DC-13
Rated operating current (Ie)0.75 A0.27 A
Rated operating voltage (Ue)240 V250 V

 

Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device.

UL/CSA (UL508, CSA C22.2 No. 14)C300

 

Rated voltageCarry currentCurrent (A)Volt-amperes (VA)
MakeBreakMakeBreak
120 VAC2.5 A151.51,800180
240 VAC7.50.75
 

View Complete Details

Yes, I am interested!

Safety-Door Hinge Switch D4NH
Interested in this product?
Get Best Quote
Specifications:

Standards and EC DirectivesConforms to the following EC Directives:

• Machinery Directive 
• Low Voltage Directive 
• EN50047 
• EN60204-1 
• EN ISO 14119 
• GS-ET-15

Certified Standards

 

Certification bodyStandardFile No.
TÜV SÜDEN60947-5-1 
(certified direct opening)
Ask your OMRON representative for information on certified models.
UL *UL508, CSA C22.2 No.14E76675
CCC (CQC)GB14048.52004010305105973

 

* Certification for CSA C22.2 No. 14 is authorized by the UL mark.

Certified Standard RatingsTÜV (EN60947-5-1)

 

Utilization categoryAC-15DC-13
Rated operating current (Ie)3 A0.27 A
Rated operating voltage (Ue)240 V250 V

 

 

Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built 
           into the Switch.

 

UL/CSA (UL508, CSA C22.2 No. 14)A300

 

Rated voltageCarry currentCurrent (A)Volt-amperes (VA)
MakeBreakMakeBreak
120 VAC10 A6067,200720
240 VAC303
 

View Complete Details

Yes, I am interested!

Safety-Door Switch D4BS
Interested in this product?
Get Best Quote

Safety-Door Switch D4BS

Get Latest Price

Specifications:

Standards and EC DirectivesConforms to the following EC Directives:

Machinery Directive 
Low Voltage Directive 
EN50041 
EN ISO 14119

Certified Standards

 

Certification bodyStandardFile No.
TÜV RheinlandEN60947-5-1 
(certified direct opening) 
GS-ET-15
Consult your OMRON 
representative for details.
ULUL508E76675
CSACSA C22.2 No. 14LR45746
CQC (CCC)GB14048.52003010305073833

 

Certified Standard RatingsTÜV (EN60947-5-1), CCC (GB14048.5)

 

Utilization categoryAC-15
Rated operating current (Ie)0.75 A
Rated operating voltage (Ue)240 V

 

Note: Use a 10 A fuse type a gI or gG that conforms to IEC60269 as a short-circuit protection device.

UL/CSA (UL508, CSA C22.2 No. 14) (A600)

 

Rated voltageCarry currentCurrent (A)Volt-amperes (VA)
MakeBreakMakeBreak
120 VAC 
240 VAC 
480 VAC 
600 VAC
10 A60 
30 
15 
12


1.5 
1.2
7,200720
 

View Complete Details

Yes, I am interested!

Guard Lock Safety-Door Switch D4BL
Interested in this product?
Get Best Quote
Specifications:

Standards and EC DirectivesConforms to the following EC Directives:

Machinery Directive 
Low Voltage Directive 
EN ISO 14119

Certified Standards

 

Certification bodyStandardFile No.
TÜV RheinlandEN60947-5-1 
(certified direct opening) 
GS-ET-19
Consult your OMRON 
representative for details.
ULUL508E76675
CSACSA C22.2, No.14LR45746
CQC (CCC)GB14048.52003010305073836

 

Certified Standard RatingsTÜV (EN60947-5-1), CCC (GB14048.5)

 

TypeStandard modelIndicator model
Utilization categoryAC-15AC-15
Rated operating current (Ie)3 A6 A
Rated operating voltage (Ue)250 V115 V

 

Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device.

UL/CSA (UL508, CSA C22.2 No. 14)A300

 

Rated voltageCarry currentCurrent (A)Volt-amperes (VA)
MakeBreakMakeBreak
120 VAC 
240 VAC
10 A60 
30

3
7,200720
 

View Complete Details

Yes, I am interested!

Guard Lock Safety-Door Switch/Slide key D4GL
Interested in this product?
Get Best Quote
Specifications:

Standards and EC DirectivesConforms to the following EC Directives:

• Machinery Directive
• Low Voltage Directive
• EN1088
• EN60204-1
• GS-ET-19

Certified StandardsStandard type

 

Certification bodyStandardFile No.
TÜV SÜDEN60947-5-1 (certified direct opening)Consult your OMRON representative for details.
UL *1UL508, CSA C22.2 No.14E76675
CQC (CCC)GB14048.52003010305064264
KOSHA *2EN 60947-5-1Consult your OMRON representative for details.
*1. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
*2. Only certain models have been certified.

 

Metallic release key type

 

Certification bodyStandardFile No.
TÜV SÜDEN60947-5-1 (certified direct opening)Consult your OMRON representative for details.
KOSHAEN 60947-5-1Consult your OMRON representative for details.

 

Certified Standard RatingsTÜV (EN60947-5-1), CCC (GB14048.5)

 

Utilization categoryAC-15DC-13
Rated operating current (Ie)0.75 A0.27 A
Rated operating voltage (Ue)240 V250 V

View Complete Details

Yes, I am interested!

Safety Limit Switch D4N
Interested in this product?
Get Best Quote

Safety Limit Switch D4N

Get Latest Price

Specifications:

Characteristics

 

Degree of protection *1IP67 (EN60947-5-1)
Durability *2Mechanical15,000,000 operations min. *5
Electrical500,000 operations min. (3 A resistive load at 250 VAC) *3
300,000 operations min. (10 A resistive load at 250 VAC)
Operating speed1 to 500 mm/s (D4N-1120)
Operating frequency30 operations/minute max.
Contact resistance25 mΩ max.
Minimum applicable load *41 mA resistive load at 5 VDC (N-level reference value)
Rated insulation voltage (Ui)300 V
Rated frequency50/60 Hz
Protection against electric shockClass II (double insulation)
Pollution degree (operating environment)3 (EN60947-5-1)
Impulse withstand 
voltage
(EN60947-5-1)
Between terminals of same polarity2.5 kV
Between terminals of different
polarity
4 kV
Between each terminal and non-
current carrying metallic parts
6 kV
Insulation resistance100 MΩ min.
Contact gapSnap-action: 2 × 0.5 mm min.
Slow-action: 2 × 2 mm min.
Vibration resistanceMalfunction10 to 55 Hz, 0.75 mm single amplitude
Shock resistanceDestruction1,000 m/s2 min.
Malfunction300 m/s2 min.
Conditional short-circuit current100 A (EN60947-5-1)
Conventional free air thermal current (Ith)10 A (EN60947-5-1)
Ambient operating temperature-30 to 70°C (with no icing)
Ambient operating humidity95% max.
WeightApprox. 82 g (D4N-1120)
Approx. 99 g (D4N-6120)
 

View Complete Details

Yes, I am interested!

Small Safety Limit Switch D4F
Interested in this product?
Get Best Quote
Specifications:

Characteristics

 

Degree of protection *1IP67 (EN60947-5-1)
Durability *2Mechanical10,000,000 times min.
Electrical1,000,000 times min. (4 mA resistive load at 24 VDC, 4 circuits)
150,000 times min. (1 A resistive load at 125 VAC, 2 circuits/4 mA resistive load at 24
VDC, 2 circuits) *3
Operating speed1 mm/s to 0.5 m/s
Operating frequencyMechanical120 operations/minute
Electrical30 operations/minute
Contact resistance *5300 mΩ max. (with 1 m cable), 500 mΩ max. (with 3 m cable), 700 m Ωmax. (with 5 m
cable)
Minimum applicable load *44 mA resistive load at 24 VDC, 4 circuits (N-level reference value)
Rated insulation voltage (Ui)250 V
Rated frequency50/60 Hz
Protection against electric shockClass I (with a ground wire)
Pollution degree (operating environment)3 (EN60947-5-1)
Impulse withstand
voltage
(EN60947-5-1)
Between terminals
of same polarity
2.5 kV
Between terminals
of different polarity
4 kV
Between each
terminal and ground
4 kV
Insulation resistance100 MΩ min. (at 500 VDC) between terminals of the same polarities, between terminals
of different polarities, between current-carrying metal parts and grounds, and between
each terminal and non-current carrying metal parts
Contact gap2 × 2 mm min.
Vibration resistanceMalfunction10 to 55 Hz, 0.75 mm single amplitude
Shock resistanceDestruction1,000 m/s2 min.
Malfunction300 m/s2 min.
Conditional short-circuit current100 A (EN60947-5-1)
Conventional free air thermal current (Ith)2.5 A (EN60947-5-1)
Ambient operating temperature- 30 to 70°C (with no icing)
 

View Complete Details

Yes, I am interested!

Safety Limit Switch D4B-N
Interested in this product?
Get Best Quote
Specifications:

Standards and EC DirectivesConforms to the following EC Directives:

• Machinery Directive 
• Low Voltage Directive 
• EN50041 
• EN60204-1 
• EN ISO 14119

Certified StandardsSnap-action Models

 

Certification bodyStandardFile No.
TÜV RheinlandEN60947-5-1 
(certified direct opening mechanism) 
GS-ET-15
Consult your OMRON 
representative for details.
EN60947-5-1 
(uncertified direct opening mechanism)
J50005477 *
ULUL508E76675
CSAC22.2 No. 14LR45746
CQC (CCC)GB14048.52003010305077612

 

* Adjustable roller lever, adjustable rod lever only.

Slow-action Mode

 

Certification bodyStandardFile No.
TÜV RheinlandEN60947-5-1 
(certified direct opening mechanism) 
GS-ET-15
Consult your OMRON 
representative for details.
EN60947-5-1 
(uncertified direct opening mechanism)
J50005477 *
ULUL508E76675
CSAC22.2 No. 14LR45746
CQC (CCC)GB14048.52003010305077612

 

* Adjustable roller lever, adjustable rod lever only.

Certified Standard RatingsTÜV (EN60947-5-1), CCC (GB14048.5)

 

Utilization categoryAC-15
Rated operating current (Ie)2 A
Rated operating voltage (Ue)400 V
 

View Complete Details

Yes, I am interested!

Pull-Reset Safety Limit Switch D4N-R
Interested in this product?
Get Best Quote
Specifications:

Characteristics

 

Degree of protection *1IP67 (EN60947-5-1)
Durability *2Mechanical1,000,000 operations min.
Electrical500,000 operations min. (3 A resistive load at 250 VAC) *3
300,000 operations min. (10 A resistive load at 250 VAC)
Operating speed1 to 500 mm/s (D4N-1A20R)
Operating frequency30 operations/minute max.
Contact resistance25 mΩ max.
Minimum applicable load *41 mA resistive load at 5 VDC (N-level reference value)
Rated insulation voltage (Ui)300 V
Rated frequency50/60 Hz
Protection against electric shockClass II (double insulation)
Pollution degree (operating environment)3 (EN60947-5-1)
Impulse withstand
voltage
(EN60947-5-1)
Between terminals of same polarity2.5 kV
Between terminals of different polarity4 kV
Between each terminal and non-current
carrying metallic parts
6 kV
Insulation resistance100 MΩ min.
Contact gap2 × 2 mm min.
Vibration resistanceMalfunction10 to 55 Hz, 0.75 mm single amplitude
Shock resistanceDestruction1,000 m/s2
Malfunction300 m/s2
Conditional short-circuit current100 A (EN60947-5-1)
Conventional free air thermal current (Ith)10 A (EN60947-5-1)
Ambient operating temperature-30 to 70°C (with no icing)
Ambient operating humidity95% max.
WeightApprox. 92 g (D4N-1A20R)
 

View Complete Details

Yes, I am interested!

Emergency Stop Switch A165E
Interested in this product?
Get Best Quote
Specifications:

Switch RatingsModels with Separate Construction

 

Rated voltageResistive load
125 VAC 
250 VAC 
30 VDC
5A 
3A 
3A

 

Note: Minimum applicable load: 5 VDC, 150 mA

Models with One-piece Construction

 

Rated voltageResistive load
125 VAC 
250 VAC 
30 VDC
1A 
0.5A 
1A

 

Note: Minimum applicable load: 5 VDC, 1 mA

LED Ratings(Only for Models with LEDs)

 

Rated voltageRated currentOperation voltage
24 VAC/VDC8 mA24 VAC/VDC±5%

 

Characteristics

 

TypeEmergency Stop Switch
Non-lighted
A165E-S/A165E-M
Lighted
A165E-LS/A165-LM
Non-lighted,
One-piece construction
A165E-U
Allowable 
operating 
frequency
Mechanical20 operations/minute max.
Electrical10 operations/minute max.
Insulation resistance100 MΩ min. (at 500 VDC)
Dielectric 
strength
Between terminals 
of same polarity
1,000 VAC, 50/60 Hz for 1 min
Between terminals 
of different polarity
2,000 VAC 50/60 Hz for 1 min
Between each 
terminal and ground
2,000 VAC 50/60 Hz for 1 min
Between lamp 
terminals
1,000 VAC, 50/60 Hz for 1 min *1---
Vibration 
resistance
Malfunction10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms)
 

View Complete Details

Yes, I am interested!

Emergency Stop Switch A22E
Interested in this product?
Get Best Quote
Specifications:

RatingsContacts (Standard Load)

 

Rated carry 
current (A)
Rated voltage 
(V)
Rated current (A)
AC15 
(inductive load)
AC12 
(resistive load)
DC13 
(inductive load)
DC12 
(resistive load)
1024 VAC1010------
110 VAC510
220 VAC36
380 VAC23
440 VAC12
24 VDC------1.510
110 VDC0.52
220 VDC0.20.6
380 VDC0.10.2
Note: 1. Rated current values are determined according to the testing conditions. The above ratings were obtained by 
             conducting tests under the following conditions. 
              (1) Ambient temperature: 20°±2°C 
              (2) Ambient humidity: 65±5% 
              (3)Operating frequency: 20 operations/minute 
         2. Minimum applicable load: 10 mA at 5 VDC

 

LED Indicators without Voltage Reduction Unit

 

Rated voltageRated currentOperating voltage
6 VAC/VDC8 mA6 VAC/VDC±5%
12 VAC/VDC12 VAC/VDC±5%
24 VAC/VDC24 VAC/VDC±5%

 

Characteristics

 

TypeEmergency Stop Switches
Non-lighted model: A22ELighted model: A22EL
Allowable operating 
frequency
Mechanical30 operations/minute *3
Electrical30 operations/minute *3
Insulation resistance100 MΩ min. (at 500 VDC)
Dielectric 
strength
Between terminals 
of same polarity
2,500 VAC, 50/60 Hz for 1 min
Between each terminal 
and ground
2,500 VAC, 50/60 Hz for 1 min
Vibration resistance *210 to 55 Hz, 1.5-mm double amplitude (within 1 ms)
Shock resistanceDestruction1,000 m/s2
Malfunction *2250 m/s2 max.
DurabilityMechanical300,000 operations min. *3
Electrical300,000 operations min. *3
Ambient operating temperature *1-20 to 70°C-20 to 55°C
Ambient operating humidity35% to 85%
Ambient storage temperature-40 to 70°C
Degree of protectionIP65 (oil-resistant) *4IP65 *4
Electric shock protection classClass II
PTI (tracking characteristic)175
Degree of contamination3 (EN60947-5-1)
 

View Complete Details

Yes, I am interested!

Enabling Grip Switch
Interested in this product?
Get Best Quote

Enabling Grip Switch

Get Latest Price

Specifications:

Ratings

 

SectionEnabling switchEmergency stop switch
(A4EG-BE2R041 only)
Pushbutton
(A4EG-BM2B041 only)
Rated insulation voltage250 V
Rated ON current2.5 A5 A0.1 A
Rated load24 VDC, 0.3 A (inductive load)
125 VAC, 1 A (resistive load)

EN certification rating:
AC-15 0.75 A/240 V
DC-13 0.55 A/125 V
General rating:
125 VAC, 5 A (resistive load)
250 VAC, 3 A (resistive load)
30 VDC, 3 A (resistive load)

UL and cUL rating:
125 VAC, 5A
(inductive load, power factor: 0.75 to 0.8)
250 VAC, 3 A
(inductive load, power factor: 0.75 to 0.8)
30 VDC, 3 A (resistive load)

EN certification rating:
AC-12 3 A/250 V
DC-12 3 A/30 V
General rating:
125 VAC, 0.1 A (resistive load)
8 VDC, 0.1 A (resistive load)
14 VDC, 0.1 A (resistive load)
30 VDC, 0.1 A (resistive load)

UL and cUL rating:
125 VAC, 0.1 A (resistive load)
30 VDC, 0.1 A (resistive load)

EN certification rating:
AC-12 0.1 A/125 V
DC-12 0.1 A/30 V
Minimum applicable load24 VDC, 4 mA5 VDC, 1 mA
 

View Complete Details

Yes, I am interested!

Enabling Switch
Interested in this product?
Get Best Quote

Enabling Switch

Get Latest Price

Specifications:

Ratings

 

Rated insulation voltage250 V
Rated ON current2.5 A
Rated load24 VDC, 300 mA (inductive load)
125 VAC, 1 A (resistive load)
Minimum applicable load24 VDC, 4 mA
Impulse withstand voltage4.0 kV between terminals of different polarity, 2.5 kV between terminals of same polarity
Ambient operating temperature-10 to 55°C (with no icing)
Ambient operating humidity35% to 85% (with no condensation)
Ambient storage temperature-25 to 65°C

 

Characteristics

 

Insulation resistance100 MΩ min. (at 500 VDC)
Contact resistance100 mΩ max. (initial value)
Vibration resistance10 to 55 Hz, 0.75-mm single amplitude min.
Shock resistance150 m/s2
Mechanical durabilityOFF-ON: 1,000,000 operations min.
OFF-ON-OFF (direct opening): 100,000 operations min.
Electrical durability100,000 operations min.
Degree of protectionIP65 (rubber seal type only)
 

View Complete Details

Yes, I am interested!

Relays With Forcibly Guided Contacts G7SA
Interested in this product?
Get Best Quote
Specifications:

RatingsCoil (4 poles)

 

ItemRated current (mA)Coil resistance (Ω)Max. voltage (V)Power consumption (mW)
Rated voltage
12 VDC30400110%Approx. 360
18 VDC20900
21 VDC17.11,225
24 VDC151,600
48 VDC7.56,400

 

Coil (6 poles)

 

ItemRated current (mA)Coil resistance (Ω)Max. voltage (V)Power consumption (mW)
Rated voltage
12 VDC41.7288110%Approx. 500
18 VDC27.8648
21 VDC23.8882
24 VDC20.81,152
48 VDC10.44,606

 

Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%. 
           2. The maximum voltage is based on an ambient operating temperature of 23°C maximum.

Contacts

 

LoadResistive load
Rated load6 A at 250 VAC, 6 A at 30 VDC
Rated carry current6 A
Max. switching voltage250 VAC, 125 VDC
Max. switching current6 A
 

View Complete Details

Yes, I am interested!

Power Relays
Interested in this product?
Get Best Quote

Power Relays

Get Latest Price

Specifications:

RatingsCoil Ratings

 

ItemRated 
current
(mA)
Coil 
resistance
(Ω)
Must operate 
voltage
Must release 
voltage
Maximum 
voltage
Power 
consumption
(W)
Rated voltagePercentage of rated voltage
12 VDC3083975% max.10% min.110%Approx. 3.7
24 VDC154156

 

 

Note: 1. Rated current and coil resistance were measured at a coil temperature of 23°C with coil resistance of ±15%. 
           2. Operating characteristics were measured at a coil temperature of 23°C. 
           3. The maximum allowable voltage is the maximum value of the fluctuation range for the Relay coil operating 
                power supply and was measured at an ambient temperature of 23°C. 
                There is, however, no continuous allowance.

 

Contact RatingsRelay

 

ModelG7Z-4A-[]Z, G7Z-3A1B-[]Z, G7Z-2A2B-[]Z
LoadResistive loadInductive load cosφ = 0.3Resistive load L/R = 1 ms
Contact structureDouble break
Contact materialAg alloy
Rated loadNO40 A at 440 VAC22 A at 440 VAC5 A at 110 VDC
NC25 A at 440 VAC10 A at 440 VAC5 A at 110 VDC
Rated carry currentNO40 A *
NC25 A
Maximum contact voltage480 VAC125 VDC
Maximum contact currentNO40 A22 A5 A
NC25 A10 A5 A
Maximum switching capacityNO17,600 VA9,680 VA550 W
NC11,000 VA4,400 VA550 W
Failure rate P value (reference value)2 A at 24 VDC
 

View Complete Details

Yes, I am interested!

Relays with Forcibly Guided Contacts G7S--E
Interested in this product?
Get Best Quote
Specifications:

RatingsCoil

 

Rated voltageRated current (mA)Coil resistance (Ω)Max. voltage (V)Power consumption (W)
24 VDC30800110%Approx. 0.8
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%. 
           2. The maximum voltage is based on an ambient operating temperature of 23°C maximum.

 

Contacts

 

LoadResistive load
Rated loadNO contact10 A at 250 VAC 
10 A at 30 VDC
NC contact6 A at 250 VAC 
6 A at 30 VDC
Rated carry currentNO contact10 A
NC contact6 A
Maximum switching voltage250 VAC, 30 VDC
Maximum switching currentNO contact10 A
NC contact6 A

 

G7S-[]-E Characteristics of Sockets

 

ModelP7S-14F-ENDP7S-14P-E
Continuous currentP7S-14P-E
Dielectric strength2000 VAC for 1 min. between terminals
Insulation resistance1000 MΩ min. *
WeightApprox. 110gApprox. 25g
Note: Use the P7S-14F-END in the ambient humidity range of 35 to 85%. 
* Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC. 

View Complete Details

Yes, I am interested!

Safety Relay Unit G9SE
Interested in this product?
Get Best Quote

Safety Relay Unit G9SE

Get Latest Price

Specifications:

RatingsPower Input

 

ModelG9SE-201G9SE-401G9SE-221-T[]
Rated supply voltage24 VDC
Operating voltage range-15% to 10% of rated supply voltage
Rated power consumption *13 W max.4 W max.

 

Outputs

 

ModelG9SE-201G9SE-401G9SE-221-T[]
Safety output 
OFF-delayed Safety output
Contact output 
250 VAC 5 A 30 VDC 5 A (resistive load)
Auxiliary outputPNP transistor output Load current: 100 mA DC max.

 

Characteristics

 

ModelG9SE-201G9SE-401G9SE-221-T[]
Operating time (OFF to ON state) *2100 ms Max. *3
Response time (ON to OFF state) *415 ms Max.
Accuracy of OFF-delay time-Within plus or minus 
10% of the set value
InputsInput current5 mA Min.
ON voltage11 VDC Min.
OFF voltage5 VDC Max.
OFF current1 mA Max.
Maximum cable length100 m Max.
Reset input time250 ms Min.
Contact 
outputs
Contact resistance *5100 mΩ
Mechanical durability5,000,000 operations Min.
Electrical durability50,000 operations Min.
Switching specification Inductive 
load (IEC/EN60947-5-1)
AC15: 240 VAC 2 A 
DC13: 24 VDC 1.5 A
Minimum applicable load24 VDC 4 mA
Conditional short-circuit current 
(IEC/EN60947-5-1)
100A *6
Pollution degree2
Over voltage category (IEC/EN60664-1)Safety output: Class III, the others: Class II
Insulation 
specification
Impulse 
withstand 
voltage 
(IEC/ 
EN60947-5-1)
Between input and 
output
6 kV
Between different 
poles of output
6 kV (between 13-14/23-24 and 33-34/43-44 (37-38/47-48)) 
4 kV (between 13-14 and 23-24, between 33-34 (37-38) and 
43-44 (47-48))
Dielectric 
strength
Between input and 
output
2,200 VDC
Between different 
poles of output
1,500 VAC
Insulation resistance100 MΩ
Vibration resistance *7Frequency: 10 to 55 to 10 Hz 
Amplitude: 0.35 mm half amplitude (0.7 mm double amplitude)
 

View Complete Details

Yes, I am interested!

Safety CPU Unit NX-SL
Interested in this product?
Get Best Quote

Safety CPU Unit NX-SL

Get Latest Price

Specifications:

Regulations and Standards

 

Certification bodyStandards
TÜV Rheinland *EN ISO 13849-1: 2008 AC: 2009 
EN ISO 13849-2: 2012 
IEC 61508 parts 1-7: 2010 
EN 62061: 2005 
EN 61131-2: 2007 
EN ISO 13850: 2008 
EN 60204-1: 2006 A1: 2009 AC: 2010 
EN 61000-6-2: 2005 
EN 61000-6-4: 2007 
NFPA 79: 2012 
ANSI RIA 15.06-1999 
ANSI B11.19-2010 
UL1998 
IEC 61326-3-1: 2008
ULcULus: Listed (UL508) and ANSI/ISA 12.12.01

 

* Certification was received for applications in which OMRON FSoE devices are connected to each other.

The NX-series Safety Control Units allow you to build a safety control system that meets the following standards. 

  • Requirements for SIL 3 (Safety Integrity Level 3) in IEC 61508, EN 62061, Safety Standard for Safety Instrumented Systems (Functional Safety of Electrical/Electronic/Programmable Electronic Safety-related Systems)
  • Requirements for PLe (Performance Level e) and for safety category 4 in EN ISO13849-1
The NX-series Safety Control Units are also registered for C-Tick and KC compliance.

 

General Specification

 

ItemSpecification
EnclosureMounted in a panel (open)
Grounding methodGround to 100 Ω or less.
Operating 
environment
Ambient operating 
temperature
0 to 55°C (The upper limit of the ambient operating temperature is 
restricted by the installation orientation.)
Ambient operating 
humidity
10% to 95% (with no condensation or icing)
AtmosphereMust be free from corrosive gases.
Ambient storage 
temperature
-25 to 70°C (with no condensation or icing)
Altitude2,000 m max.
Pollution degree2 or less: Conforms to JIS B3502 and IEC 61131-2.
Noise immunityConforms to IEC 61131-2. 
2 kV on power supply line (Conforms to IEC 61000-4-4.)
Insulation classClass III (SELV)
Overvoltage categoryCategory II: Conforms to JIS B3502 and IEC 61131-2.
EMC immunity levelZone B
Vibration resistanceConforms to IEC 60068-2-6. 
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m/s2
100 minutes each in X, Y, and Z directions (10 sweeps of 10 min each = 100 
min total)
Shock resistanceConforms to IEC 60068-2-27. 
147 m/s2, 3 times each in X, Y, and Z directions
Insulation resistance20 MΩ between isolated circuits (at 100 VDC)
 

View Complete Details

Yes, I am interested!

Safety Controller G9SP
Interested in this product?
Get Best Quote

Safety Controller G9SP

Get Latest Price

Specifications:

G9SP SeriesGeneral Specifications

 

Power supply voltage24 VDC (20.4 to 26.4 VDC -15% 10%)
Current consumption *G9SP-N10S: 400 mA (V1: 300 mA, V2: 100 mA) 
G9SP-N10D: 500 mA (V1: 300 mA, V2: 200 mA) 
G9SP-N20S: 500 mA (V1: 400 mA, V2: 100 mA)
Isolation classClass III (SELV)
Overvoltage categoryII
Noise immunityConforms to IEC61131-2
Vibration resistance5 to 8.4 Hz: 3.5 mm, 8.4 to 150 Hz: 9.8 m/s2
Shock resistance147 m/s2: 11 ms
MountingDIN track mounting (IEC60715 TH35-7.5/TH35-15) or M4 screws
Ambient operating temperature0 to 55°C
Ambient operating humidity10% to 90% (with no condensation)
Ambient storage temperature-20°C to 75°C
AtmosphereNo corrosive gas
Operating altitude2,000 m max.
Pollution degreePollution degree 2
Degree of protectionIP20 except terminal blocks
Terminal screwsM3 self-rising screws
 

View Complete Details

Yes, I am interested!

Flexible Safety Unit G9SX
Interested in this product?
Get Best Quote
Specifications:

Ratings Power input

 

ModelG9SX-AD322-[]/ADA222-[]G9SX-BC202-[]G9SX-EX-[]
Rated supply voltage24 VDC
Operating voltage range-15% to 10% of rated supply voltage
Rated power consumption *4 W max.3 W max.2 W max.
* Power consumption of loads not included.

 

Inputs

 

ModelG9SX-AD322-[]/ADA222-[]G9SX-BC202-[]
Safety inputOperating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8 kΩ *
Feedback/reset input
* Provide a current equal to or higher than that of the minimum applicable load of the connected input control device.

 

Outputs

 

ModelG9SX-AD322-[]/ADA222-[]G9SX-BC202-[]
Instantaneous safety output *1 
OFF-delayed safety output *1
P channel MOS-FET output 
Load current: 
0.8 A DC max./output *2 *3
P channel MOS-FET output 
Load current: 
0.8 A DC max./output *2 *3
Auxiliary outputPNP transistor output 
Load current: 100 mA max./output
*1. While safety outputs are in the ON state, the following signal sequence is output continuously for diagnosis. When 
       using the safety outputs as input signals to control devices (i.e. Programmable Controllers), consider the OFF pulse 
       shown below.

 

 

*2. The following derating is required when Units are mounted side-by-side. 
       G9SX-AD322-[]/G9SX-ADA222-[]/G9SX-BC202-[]: 0.4 A max. load current/output 
*3. A load current below 1 A DC/output can be used when the following outputs are used. 
       G9SX-AD322-[]/G9SX-ADA222-[]: 2 outputs or less 
       G9SX-BC202-[]: 1 output

 

Expansion Unit Ratings

 

ModelG9SX-EX-[]
Rated load250 VAC, 3 A/30 VDC, 3 A (resistive load)
Rated carry current3 A
Maximum switching voltage250 VAC, 125 VDC
 

View Complete Details

Yes, I am interested!

Standstill Monitoring Unit
Interested in this product?
Get Best Quote
Specifications:

RatingsPower input

 

ModelG9SX-SM032-[]
Rated supply voltage24 VDC
Operating voltage range-15% to 10% of rated supply voltage
Power consumption *4 W max.

 

* Power consumption of loads not included.

Inputs

 

ModelG9SX-SM032-[]
Rated Input voltageStandstill detection input (between Z1 and Z2 and between Z3 and Z4) *1
480 VAC max. (120Hz max.) *2
Internal impedanceStandstill detection input: Approx. 660 kΩ
EDM input: Approx. 2.8 kΩ *3

 

*1. Input the motor phase-to-phase voltage between Z1 and Z2 and between Z3 and Z4. 
*2. When a motor with AC240V or more is used, connect neutral point of the power supply to earth. 
*3. Use a contact that is applicable to microloads (24 VDC, 5 mA) for connection to the EDM input.

Outputs

 

ModelG9SX-SM032-[]
Safety standstill detection output * 1Source output (PNP), load current: 0.3 A DC max. * 2
Auxiliary output (output monitor/error)Source output (PNP), load current: 100 mA DC max.

 

 

*1. While safety standstill detection outputs are in the ON state, the following pulse signal is output continuously for output 
       circuit diagnosis. 
       When using the safety standstill detection outputs as input signals to control devices (i.e. Programmable Controllers), 
       consider the pulse signal shown below.

 

 

*2. The following derating is required when Units are mounted side-by-side. 
       G9SX-SM032-[]: 0.2 A max. load current 

View Complete Details

Yes, I am interested!

Low-speed Monitoring Unit G9SX-LM
Interested in this product?
Get Best Quote
Specifications:

RatingsPower input

 

ModelG9SX-LM224-[]G9SX-EX401-[]
Rated supply voltage24 VDC
Operating voltage range-15% to 10% of rated supply voltage
Power consumption *5 W max.2 W max.

 

* Power consumption of loads not included.

Inputs

 

ModelG9SX-LM224-[]
Safety input
Enabling input
Feedback/reset input
Mode selector input
Operating voltage: 20.4 VDC to 26.4 VDC
Internal impedance: Approx. 2.8 kΩ *
Rotation detection inputOperating voltage: 20.4 VDC to 26.4 VDC
Internal impedance: Approx. 2.8 kΩ *
Frequency input range: 1 kHz max.

 

* Provide a current equal to or higher than that of the minimum applicable load of the connected input control device.

Outputs

 

ModelG9SX-LM224-[]
Safety instantaneous output *1Source output (PNP compatible)
Load current: 0.8 A DC max. * 2
Safety speed detection output *1Source output (PNP compatible)
Load current: 0.3 A DC max.
Auxiliary outputSource output (PNP compatible)
Load current: 100 mA DC max.

 

 

*1. While safety instantaneous outputs and safety speed detection outputs are in the ON state, the following pulse signal 
       is output continuously for output circuit diagnosis. 
       When using these safety outputs as input signals to control devices (i.e. Programmable Controllers), consider the 
       pulse signal shown below. 

View Complete Details

Yes, I am interested!

Safety Guard Switching Unit G9SX-GS
Interested in this product?
Get Best Quote
Specifications:

RatingsPower Input

 

ModelG9SX-GS226-T15-[]G9SX-EX-[]
Rated supply voltage24 VDC
Operating voltage range-15% to 10% of rated supply voltage
Rated power consumption *5 W max.2 W max.
* Power consumption of loads not included.

 

Inputs

 

ModelG9SX-GS226-T15-[]
Safety inputsOperating voltage: 20.4 VDC to 26.4 VDC, Internal impedance: Approx. 2.8 kΩ *
Mode selector input
Feedback/reset input
* Provide a current equal to or higher than that of the minimum applicable load of the connected input control device.

 

Outputs

 

ModelG9SX-GS226-T15-[]
Instantaneous safety outputs *1 
OFF-delayed safety outputs *1
P channel MOS-FET outputs 
Load current: 0.8 A DC max./output *2
Auxiliary outputs 
(for input, output, and error monitoring)
PNP transistor outputs 
Load current: 0.8 A DC max./output *2
External indicator outputsP channel MOS-FET outputs 
Connectable indicators 
• Incandescent lamp: 24 VDC, 3 to 7 W 
• LED lamp: 10 to 300 mA DC/output
*1. While safety outputs are in the ON state, the following signal sequence is output continuously for diagnosis. 
       When using the safety outputs as input signals to control devices (i.e. Programmable Controllers), consider the OFF 
       pulse shown below. 

View Complete Details

Yes, I am interested!

Safety Relay Unit
Interested in this product?
Get Best Quote

Safety Relay Unit

Get Latest Price

Specifications:

RatingsPower Input

 

ModelG9SA-301/TH301G9SA-501G9SA-321-T[]
Power supply 
voltage
24 VAC/VDC: 24 VAC, 50/60 Hz, or 24 VDC
100 to 240 VAC: 100 to 240 VAC, 50/60 Hz
Operating 
voltage range
85% to 110% of rated power supply voltage
Power 
consumption*
24 VAC/VDC: 1.8 VA/1.7 W max.
100 to 240 VAC: 9 VA max.
24 VAC/VDC: 2.8 VA/2.6 W max.
100 to 240 VAC: 11 VA max.
24 VAC/VDC: 3.5 VA/3.3 W max.
100 to 240 VAC: 12.5 VA max.

 

* When an Expansion Unit is connected, the power consumption is increased by 2 VA/2 W max.

Inputs

 

ModelG9SA-301/321-T[]/TH301G9SA-501
Input current *40 mA max.60 mA max

 

* When an Expansion Unit is connected, the input current is increased by 30 mA max.

Contacts

 

Model
Load
G9SA-301/501/321-T[]/TH301/EX301/EX031-T[]
Resistive load
Rated load250 VAC, 5 A
30 VDC, 5 A
Rated carry current5 A
 

View Complete Details

Yes, I am interested!

Safety Relay Unit G9SB
Interested in this product?
Get Best Quote

Safety Relay Unit G9SB

Get Latest Price

Specifications:

RatingsPower Input

 

ModelG9SB-200[]-[]G9SB-3010G9SB-301[]-[]
Power supply voltage24 VAC/VDC: 24 VAC, 50/60 Hz, or 24 VDC
24 VDC: 24 VDC
Operating voltage range85% to 110% of rated power supply voltage
Power consumption1.6 VA/1.4 W max.1.7 W max.2.0 VA/1.7 W max.

 

Inputs

 

ModelG9SB-200[]-[]G9SB-3010G9SB-301[]-[]
Input current25 mA max.60 mA max. *30 mA max.
* Indicates the current between terminals A1 and A2.

 

Contacts

 

Model
Load
G9SB-200[]-[]G9SB-3010G9SB-301[]-[]
Resistive load
Rated load250 VAC, 5 A
30 VDC, 5 A
Rated carry current5 A

 

Characteristics

 

ModelG9SB-200[]-[]G9SB-3010G9SB-301[]-[]
Contact resistance *1100 mΩ
Operating time *230 ms max.
Response time *310 ms max.
Insulation resistance *4100 MΩ min. (at 500 VDC)
Dielectric
strength
Between different
outputs
2,500 VAC, 50/60 Hz for 1 min
Between inputs
and outputs
Between power
inputs and outputs
Vibration resistance10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Shock
resistance
Destruction300 m/s2
Malfunction100 m/s2
Durability *5Mechanical5,000,000 operations min. (at approx. 7,200 operations/hr)
Electrical100,000 operations min. (at approx. 1,800 operations/hr)
Failure rate (P level)
(reference value)
5 VDC, 1 mA

View Complete Details

Yes, I am interested!

Safety Network Controller NE1A-SCPU Series
Interested in this product?
Get Best Quote
Specifications:

Certified Standards

 

Certification bodyStandard
TÜV RheinlandNFPA 79-2012 
EN ISO13849-1: 2006 
IEC61508 part1-7: 2010 
IEC61131-2:2007 
EN ISO13849-2:2003 
EN ISO 13850:2006 (EN418: 1992) 
EN61000-6-4:2007 
EN61000-6-2:2005 
EN60204-1:2006 
ANSI RIA15.06-1999 
ANSI B11.19-2010
ULUL508 
ANSI/ISA 12.12.01 
UL1998 
NFPA79 
IEC61508 
CSA22.2 No.142 
CSA22.2 No.213

 

Specifications

 

ModelNE1A-SCPU01-V1NE1A-SCPU02
Communications power supply voltage11 to 25 VDC supplied via communications connector
Internal circuit power supply voltage (V0) *120.4 to 26.4 VDC (24 VDC -15%/ 10%)
I/O power supply voltage (V1, V2) *1
Current
consumption
Communications power supply24 VDC, 15 mA
Internal circuit power supply24 VDC, 230 mA24 VDC, 280 mA
I/O power supply *224 VDC, 40 mA (Input)
120 mA (Output)
24 VDC, 80 mA (Input)
150 mA (Output)
Overvoltage categoryII
Noise immunityConforms to IEC61131-2.
Vibration resistance10 to 57 Hz: 0.35 mm, 57 to 150 Hz: 50 m/s2
Shock resistance150 m/s2: 11 ms
Mounting methodDIN Track (IEC 60715 TH35-7.5/TH35-15)
Ambient operating temperature-10 to 55°C
Ambient operating humidity10% to 95% (with no condensation)
Ambient storage temperature-40 to 70°C
Degree of protectionIP20
Serial interfaceUSB version 1.1
Weight460 g max.690 g max.
 

View Complete Details

Yes, I am interested!

Safety Network Controller NE1A-SCPU0-EIP
Interested in this product?
Get Best Quote
Specifications:

Certified Standards

 

Certification bodyStandards
TÜV RheinlandNFPA 79-2012 
ISO13849-1: 2008 
IEC61508 part1-7: 2010 
IEC61131-2: 2007 
EN ISO13849-2: 2012 
EN61000-6-4: 2007 
EN61000-6-2: 2005 
EN60204-1: 2006 
EN ISO13850: 2006 (EN418: 1992) 
ANSI RIA15.06-1999 
ANSI B11.19-2012
ULUL508 
ANSI/ISA 12.12.01 
UL1998 
NFPA79 
IEC61508 
CSA22.2 No.142 
CSA22.2 No.213

 

Specifications

 

ModelNE1A-SCPU01-EIPNE1A-SCPU02-EIP
DeviceNet communications power supply voltage11 to 25 VDC (Supplied via communications connector.)
Unit power supply voltage (V0) *120.4 to 26.4 VDC (24 VDC -15%/ 10%)
I/O power supply voltage (V1, V2) *1
Current consumptionCommunications power supply24 VDC, 15 mA
Internal circuit power supply24 VDC, 280 mA24 VDC, 330 mA
I/O power supply *224 VDC, 40 mA (Input)
120 mA (Output)
24 VDC, 80 mA (Input)
150 mA (Output)
Overvoltage categoryII
Noise immunityConforms to IEC61131-2.
Vibration resistance10 to 57 Hz: 0.35 mm, 57 to 150 Hz: m/s2
Shock resistance150 m/s2: 11 ms
Mounting methodDIN track mounting (IEC60715 TH35-7.5/TH35-15)
Ambient operating temperature-10 to 55°C
Ambient operating humidity10% to 95% (with no condensation)
Ambient storage temperature-40 to 70°C
Degree of protectionIP20
Serial interfaceUSB version 1.1
Weight570 g max.800 g max.

 

 

*1. V0-G0: Internal control circuit 
       V1-G1 (G): For external input device, test output 
       V2-G2 (G): For external output device 
*2. Not including power consumption for external devices. 

View Complete Details

Yes, I am interested!

EtherNet/IP-Device Net Router NE1A-EDR01
Interested in this product?
Get Best Quote
Specifications:

Certified Standards

 

Certification bodyStandard
ULUL508, ANSI/ISA 12.12.01 
CSA22.2 No.142, CSA22.2 No.213

 

Specifications

 

DeviceNet communications power supply voltage11 to 25 VDC (supplied via DeviceNet communications connector)
Internal circuit power supply voltage20.4 to 26.4 VDC (24 VDC - 15%/ 10%)
Current consumptionDeviceNet communications
power supply
24 VDC, 15 mA
Internal circuit power supply24 VDC, 230 mA
Overvoltage categoryII
Noise immunityConforms to IEC 61131-2.
Vibration resistance10 to 57 Hz: 0.35 mm, 57 to 150 Hz: 50 m/s2
Shock resistance150 m/s2: 11 ms
Mounting method35-mm DIN Track (IEC 60715 TH35-7.5/TH35-15)
Ambient operating temperature- 10 to 55 ° C
Ambient operating humidity10 to 95% (with no condensation)
Ambient storage temperature- 40 to 70 ° C
Degree of protectionIP20
Weight220 g max.
 

View Complete Details

Yes, I am interested!

Safety Network Controller NE0A-SCPU01
Interested in this product?
Get Best Quote
Specifications:

Certified Standards

 

Certification bodyStandard
TÜV RheinlandNFPA 79-2012 
EN ISO13849-1: 2006 
IEC61508 part1-7: 2010 
IEC61131-2:2007 
EN ISO13849-2:2003 
EN ISO 13850:2006 (EN418: 1992) 
EN61000-6-4:2007 
EN61000-6-2:2005 
EN60204-1:2006 
ANSI RIA15.06-1999 
ANSI B11.19-2010
ULUL508 
ANSI/ISA 12.12.01 
UL1998 
NFPA79 
IEC61508 
CSA22.2 No.142 
CSA22.2 No.213

 

Specifications

 

Communications power supply voltage11 to 25 VDC supplied via communications connector
Internal circuit power supply voltage (V0) *120.4 to 26.4 VDC (24 VDC - 15%/ 10%)
I/O power supply voltage (V1, V2) *1
Current consumptionCommunications power supply24 VDC, 15 mA
Internal circuit power supply24 VDC, 110 mA
I/O power supply * 224 VDC, 80 mA (Input) 80 mA (Output)
Overvoltage categoryII
Noise immunityConforms to IEC61131-2.
Vibration resistance10 to 57 Hz: 0.35 mm, 57 to 150 Hz: 50 m/s2
Shock resistance150 m/s2 : 11 ms
Mounting methodDIN Track (IEC 60715 TH35-7.5/TH35-15)
Ambient operating temperature- 10 to 55 ° C
Ambient operating humidity10% to 95% (with no condensation)
Ambient storage temperature- 40 to 70 ° C
Degree of protectionIP20
Serial I/FUSB version 1.1
Weight440 g max.

 

 

*1. V0-G0: Internal control circuit 
       V1-G1: For external input device, test output 
       V2-G2: For external output device 
*2. Not including power consumption for external devices. 

View Complete Details

Yes, I am interested!

Safety Interlock Switches ER
Ask for Details
Tell us what you need, and we’ll help you get quotes
Tell us what you
need
Receive seller
details
Seal the deal
Pay with IndiaMART
Tell us what you need, and we’ll help you get quotes
I agree to the terms and privacy policy