Temperature Controllers

These Controllers receive sensor signals and control heaters or other devices to maintain a preset temperature. They can also be used for humidity, pressure, and flowrate control. OMRON also provides temperature and humidity sensors.

Temperature Sensor E52
Interested in this product?
Get Best Quote

Temperature Sensor E52

Get Latest Price

Specifications: 

Sheathed Platinum Resistance Thermometers

 

Element typePt100
ClassJIS class B
Sheath materialSUS316 (E52-P[]AY) 
ASTM316L (E52-P[]B-N, E52-P[]C-N)
Sheath outer diameter3.2 dia., 4.8 dia., 6.4 dia., 8 dia
Conductor type3-conductor system
Temperature range-200°C to 450°C (in dry air)

 

Standard Platinum Resistance Thermometers

 

Element typePt100
ClassJIS class B (See note 2.)
Protective tubing materialSUS316
Conductor type3-conductor system
Temperature range0°C to 450°C (in dry air)
Note: 1. Use the sheathed platinum resistance thermometer if condensation is likely to result. 
         2. Be sure that the thermometer is free of vibration or shock if high temperatures are measured.

 

Sheathed Thermocouples

 

Element typeK (CA), J(IC)
ClassJIS class 2 (0.75)
Thermal contactNon-grounded type
Sheath materialCA: ASTM316L
IC: ASTM316L
 

View Complete Details

Yes, I am interested!

Temperature Sensor  E52
Interested in this product?
Get Best Quote

Temperature Sensor E52

Get Latest Price

Specifications: 

Exclusive ModelsThermocouplesThermocouples for Molding MachinesE52-CA2GVY, E52-IC2GVY

 

Element typeK (CA), J (IC)
Element diameter1.0 mm (single wire)
ClassClass 2 (0.75)
Protective tubing materialSUS304
Thermal contactGrounded type
Temperature range0°C to 350°C
Lead wire0°C to 180°C

 

Thermocouples with Crimp TerminalsE52-CA1GTY, E52-IC1GTY

 

Element typeK (CA), J (IC)
Element diameter0.65 mm (single wire)
ClassClass 2 (0.75)
Thermal contactGrounded type
Temperature range0°C to 300°C
Lead wire0°C to 150°C
Terminal shapeY-type crimp terminal for M3.5
Note: The E52-CA1GTY is also available with double elements.

 

Platinum Resistance ThermometersPlatinum Resistance Thermometers for Surface Temperature MeasurementE52-P2GSY

 

Element typePt100
ClassClass B
Protective tubing materialSUS304 
With brass-nickel-plated bracket
Conductor type3-conductor system
Temperature range-50°C to 250°C
Lead wire-50°C to 150°C
 

View Complete Details

Yes, I am interested!

Humidity Sensor, Temperature/Humidity Sensor ES2-HB / THB
Interested in this product?
Get Best Quote
Specifications: 

Humidity Sensor sectionHigh-polymer resistive
Humidity detection range20 to 95%
Humidity detection accuracy± 3% (25 °C, 40 to 80%)
Power supply voltage24 VDC *1
Operating voltage range85% to 110% of power supply voltage
Current consumption10 mA max.
Humidity output1 to 5 V (for humidity of 0% to 100%) 
Permissible load impedance: 100 kΩ min. 
(Use a 1:1 connection when connecting to an E5CC/E5EC/E5AC.)
Temperature Sensor Section *2Platinum resistance thermometer
Temperature detection range0 to 55 °C
Temperature outputPt100: 3 wire *4
ClassJIS class B
Communications cable length5 m
Operating temperature and humidity range *30 to 55 °C, humidity of 95% max.
Storage temperature and humidity range *3-20 to 60°C, humidity of 95% max.
Degree of protectionIP 20 equivalent
WeightES2-HB: Approx. 41 g (excluding cables) 
ES2-THB: Approx. 43 g (excluding cables)
 

View Complete Details

Yes, I am interested!

Digital Temperature Controller E5GC
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageA in model number: 100 to 240 VAC, 50/60 Hz 
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption5.9 VA max. at 100 to 240 VAC, and 3.2 VA max. at 24 VAC or 1.8 W max. at 24 VDC
Sensor inputTemperature input 
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II 
Platinum resistance thermometer: Pt100 or JPt100 
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 
to 260°C 
Analog input 
Current input: 4 to 20 mA or 0 to 20 mA 
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. 
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control methodON/OFF control or 2-PID control (with auto-tuning)
Control 
output
Relay outputSPST-NO, 250 VAC, 2 A (resistive load), electrical life: 100,000 operations, minimum 
applicable load: 5 V, 10 mA (reference value)
Voltage output 
(for driving SSR)
Output voltage 12 VDC ±20% (PNP), max. Load current: 21 mA, with short-circuit 
protection circuit
Linear current 
output
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: Approx. 10,000
Auxiliary 
output
Number of outputs1 or 2 (depends on model)
Output 
specifications
SPST-NO relay outputs, 250 VAC, 2 A (resistive load), 
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference 
value)
Event 
input
Number of inputs1 or 2 (depends on model)
External contact 
input 
specifications
Contact input ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input ON: Residual voltage 1.5 V max.; OFF: Leakage current 0.1 mA max.
Current flow: approx. 7 mA per contact
Setting methodDigital setting using front panel keys
Indication method11-segment digital displays and individual indicators 
Character height: PV: 10.5 mm, SV: 5.0 mm
Multi SPUp to eight set points (SP0 to SP7) can be saved and selected using the event inputs, 
key operations, or serial communications. *
 

View Complete Details

Yes, I am interested!

Digital Temperature Controller E5CC, E5CC-U
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageA in model number: 100 to 240 VAC, 50/60 Hz 
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumptionModels with option selection of 000:5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at 
24 VAC or 1.6 W max. at 24 VDC 
All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W 
max. at 24 VDC
Sensor inputTemperature input 
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II 
Platinum resistance thermometer: Pt100 or JPt100 
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 
140 to 260°C 
Analog input 
Current input: 4 to 20 mA or 0 to 20 mA 
Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V,or 0 to 50 mV (The 0 to 50 mV range applies 
to the E5CC-U only for those manufactured in May 2014 or later.)
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. 
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control methodON/OFF control or 2-PID control (with auto-tuning)
Control 
output
Relay outputE5CC: 
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum 
applicable load: 5 V, 10 mA (reference value) 
E5CC-U: 
SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum 
applicable load: 5 V, 10 mA (reference value)
Voltage output 
(for driving SSR)
Output voltage: 12 VDC ± 20% (PNP), max. load current: 21 mA, with short-circuit 
protection circuit
Linear current 
output
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Auxiliary
output
Number of outputsE5CC: 3 
E5CC-U: 1 or 2 (depends on model)
Output 
specifications
SPST-NO relay outputs, 250 VAC, Models with 1 or 2 outputs: 3 A (resistive load), or 
Models with 3 outputs: 2 A (resistive load), Electrical life: 100,000 operations, Minimum 
applicable load: 10 mA at 5 V (reference value)
 

View Complete Details

Yes, I am interested!

Digital Temperature Controller (48 x 96 mm) E5EC
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageA in model number: 100 to 240 VAC, 50/60 Hz 
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumptionModels with option selection of 000:6.6 VA max. at 100 to 240 VAC, and 4.1 VA max. at 
24 VAC or 2.3 W max. at 24 VDC 
All other models: 8.3 VA max. at 100 to 240 VAC, and 5.5 VA max. at 24 VAC or 3.2 W 
max. at 24 VDC
Sensor inputTemperature input 
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II 
Platinum resistance thermometer: Pt100 or JPt100 
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 
to 260°C 
Analog input 
Current input: 4 to 20 mA or 0 to 20 mA 
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. 
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control methodON/OFF or 2-PID control (with auto-tuning)
Control 
output
Relay outputSPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations, 
minimum applicable load: 5 V, 10 mA (reference value)
Voltage output 
(for driving SSR)
Output voltage: 12 VDC ± 20% (PNP), max. load current: 40 mA, with short-circuit 
protection circuit (The maximum load current is 21 mA for models with two control 
outputs.)
Linear current 
output
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Auxiliary
output
Number of outputs4
Output 
specifications
SPST-NO. relay outputs, 250 VAC, Models with 4 outputs: 2 A (resistive load), 
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference 
value)
Event 
input
Number of inputs2, 4 or 6 (depends on model)
External contact 
input 
specifications
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Transfer
output
Number of outputs1 (only on models with a transfer output)
Output 
specifications
Current output: 4 to 20 mA DC, Load: 500 Ω max., Resolution: Approx. 10,000 
Linear voltage output: 1 to 5 VDC, load: 1 kΩ min., Resolution: Approx. 10,000
Remote SP inputCurrent input: 4 to 20 mA DC or 0 to 20 mA DC (input impedance: 150 Ω max.) 
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V (input impedance: 1 MΩ min.)
 

View Complete Details

Yes, I am interested!

Digital Temperature Controller (96 x 96 mm) E5AC
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageA in model number: 100 to 240 VAC, 50/60 Hz 
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumptionModels with option selection of 000:7.0 VA max. at 100 to 240 VAC, and 4.2 VA max. at 
24 VAC or 2.4 W max. at 24 VDC 
All other models: 9.0 VA max. at 100 to 240 VAC, and 5.6 VA max. at 24 VAC or 3.4 W 
max. at 24 VDC
Sensor inputTemperature input 
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II 
Platinum resistance thermometer: Pt100 or JPt100 
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 
to 260°C 
Analog input 
Current input: 4 to 20 mA or 0 to 20 mA 
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. 
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control methodON/OFF or 2-PID control (with auto-tuning)
Control 
output
Relay outputSPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations, 
minimum applicable load: 5 V, 10 mA (reference value)
Voltage output 
(for driving SSR)
Output voltage: 12 VDC ± 20% (PNP), max. load current: 40 mA, with short-circuit 
protection circuit (The maximum load current is 21 mA for models with two control 
outputs.)
Linear current 
output
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Auxiliary
output
Number of outputs4
Output 
specifications
SPST-NO. relay outputs, 250 VAC, Models with 4 outputs: 2 A (resistive load), 
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference 
value)
Event 
input
Number of inputs2, 4 or 6 (depends on model)
External contact 
input 
specifications
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Transfer
output
Number of outputs1 (only on models with a transfer output)
Output 
specifications
Current output: 4 to 20 mA DC, Load: 500 Ω max., Resolution: Approx. 10,000 
Linear voltage output: 1 to 5 VDC, load: 1 kΩ min., Resolution: Approx. 10,000
Remote SP inputCurrent input: 4 to 20 mA DC or 0 to 20 mA DC (input impedance: 150 Ω max.) 
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V (input impedance: 1 MΩ min.)
 

View Complete Details

Yes, I am interested!

Digital Temperature Controller E5DC
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageA in model number: 100 to 240 VAC, 50/60 Hz 
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption4.9 VA max. at 100 to 240 VAC, and 2.8 VA max. at 24 VDC or 1.5 W max. at 24 VDC
Sensor inputTemperature input 
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II 
Platinum resistance thermometer: Pt100 or JPt100 
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 
to 260°C 
Analog input 
Current input: 4 to 20 mA or 0 to 20 mA 
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. 
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control methodON/OFF control or 2-PID control (with auto-tuning)
Control 
output
Relay outputSPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum 
applicable load: 5 V, 10 mA (reference value)
Voltage output 
(for driving SSR)
Output voltage 12 VDC ±20% (PNP), max. Load current: 21 mA, with short-circuit 
protection circuit
Linear current 
output
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: Approx. 10,000
Auxiliary 
output
Number of outputs2 (depends on model)
Output 
specifications
SPST-NO relay outputs: 250 VAC, 2 A (resistive load), 
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference 
value)
Event 
input
Number of inputs1 (depends on model)
External contact 
input 
specifications
Contact input ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input ON: Residual voltage 1.5 V max.; OFF: Leakage current 0.1 mA max.
Current flow: approx. 7 mA per contact
Setting methodDigital setting using front panel keys
Indication method11-segment digital displays and individual indicators 
Character height: PV: 8.5 mm, SV: 8.0 mm
Multi SPUp to eight set points (SP0 to SP7) can be saved and selected using the event inputs, 
key operations, or serial communications. *1
 

View Complete Details

Yes, I am interested!

Programmable Temperature Controller E5CC-T
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageA in model number: 100 to 240 VAC, 50/60 Hz 
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption7.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC
Sensor inputTemperature input 
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II 
Platinum resistance thermometer: Pt100 or JPt100 
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 
140 to 260°C 
Analog input 
Current input: 4 to 20 mA or 0 to 20 mA 
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. 
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control method2-PID control (with auto-tuning) or ON/OFF control
Control 
output
Relay outputSPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum 
applicable load: 5 V, 10 mA (reference value)
Voltage output 
(for driving SSR)
Output voltage: 12 VDC ± 20% (PNP), max. load current: 21 mA, with short-circuit 
protection circuit
Linear current 
output
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Auxiliary
output
Number of outputs3
Output 
specifications
SPST-NO relay outputs, 250 VAC, Models with 3 outputs: 2 A (resistive load), Electrical 
life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value)
Event 
input
Number of inputs2 or 4 (depends on model)
External contact 
input 
specifications
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
 

View Complete Details

Yes, I am interested!

Programmable Temperature Controller E5CC-T
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageA in model number: 100 to 240 VAC, 50/60 Hz 
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption7.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC
Sensor inputTemperature input 
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II 
Platinum resistance thermometer: Pt100 or JPt100 
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 
140 to 260°C 
Analog input 
Current input: 4 to 20 mA or 0 to 20 mA 
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. 
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control method2-PID control (with auto-tuning) or ON/OFF control
Control 
output
Relay outputSPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum 
applicable load: 5 V, 10 mA (reference value)
Voltage output 
(for driving SSR)
Output voltage: 12 VDC ± 20% (PNP), max. load current: 21 mA, with short-circuit 
protection circuit
Linear current 
output
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Auxiliary
output
Number of outputs3
Output 
specifications
SPST-NO relay outputs, 250 VAC, Models with 3 outputs: 2 A (resistive load), Electrical 
life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value)
Event 
input
Number of inputs2 or 4 (depends on model)
External contact 
input 
specifications
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Transfer
output
Number of outputs1 (only on models with a transfer output)
Output 
specifications
Current output: 4 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000 
Linear voltage output: 1 to 5 VDC, load: 1 kΩ min., resolution: Approx. 10,000
Setting methodDigital setting using front panel keys
Indication method11-segment digital display and individual indicators 
Character height: PV: 15.2 mm, SV: 7.1 mm
 

View Complete Details

Yes, I am interested!

Programmable Temperature Controller E5AC-T
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageA in model number: 100 to 240 VAC, 50/60 Hz 
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption9.0 VA max. at 100 to 240 VAC, and 5.6 VA max. at 24 VAC or 3.4 W max. at 24 VDC
Sensor inputTemperature input 
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II 
Platinum resistance thermometer: Pt100 or JPt100 
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 
to 260°C 
Analog input 
Current input: 4 to 20 mA or 0 to 20 mA 
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. 
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control method2-PID control (with auto-tuning) or ON/OFF control
Control 
output
Relay outputSPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations, 
minimum applicable load: 5 V, 10 mA (reference value)
Voltage output 
(for driving SSR)
Output voltage: 12 VDC ± 20% (PNP), max. load current: 40 mA, with short-circuit 
protection circuit (The maximum load current is 21 mA for models with two control 
outputs.)
Linear current 
output
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Auxiliary
output
Number of outputs4
Output 
specifications
SPST-NO. relay outputs, 250 VAC, Models with 4 outputs: 2 A (resistive load), 
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference 
value)
Event 
input
Number of inputs2, 4 or 6 (depends on model)
External contact 
input 
specifications
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
 

View Complete Details

Yes, I am interested!

Advanced Digital Temperature Controller (48 x 48 mm) E5CN-H
Interested in this product?
Get Best Quote
Specifications:

Ratings

 

Power supply voltageNo D in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption100 to 240 VAC: 8.5 VA (max.) (E5CN-HR2 at 100 VAC: 3.0 VA)
24 VAC/VDC: 5.5 VA (24 VAC)/3.5 W (24 VDC) (max.) (E5CN-HR2D at 24 VAC: 2.7 VA)
Sensor inputAny of the following can be selected (i.e., fully universal input).
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 M Ω min. (Use a 1:1 connection when connecting the ES2-HB.)
Control methodON/OFF control or 2-PID control (with auto-tuning)
Control
output
Relay outputSPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
Voltage output
(for driving SSR)
Output voltage: 12 VDC ± 15% (PNP), max. load current: 21 mA, with short-circuit protection circuit
Current output4 to 20 mA DC/0 to 20 mA DC, load: 600 Ω max., resolution: approx. 10,000 *
Linear voltage output0 to 10 VDC (load: 1 k Ω min.), Resolution: Approx. 10,000
Auxiliary
output
Number of outputs2 max.
Output specificationsRelay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA

View Complete Details

Yes, I am interested!

Advanced Digital Temperature Controller E5AN-H, E5EN-H
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageNo D in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption100 to 240 VAC: 12 VA
24 VAC/VDC: 8.5 VA (24 VAC)/5.5 W (24 VDC)
Sensor inputAny of the following can be selected.
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 M Ω min. (Use a 1:1 connection when connecting the ES2-HB.)
Control methodON/OFF control or 2-PID control (with auto-tuning)
Control
output
Relay outputOutput Unit (Install the Output Unit (sold separately).)
Voltage output
(for driving SSR)
Current output
Linear voltage
output
Built-in SSR output75 to 250 VAC, 1 A (resistive load)
Relay output for
position-
proportional control
Relay output: Open and close: SPST-NO, 250 VAC, 1 A (including in-rush current), electrical life: 100,000 operations min.
Potentiometer input: Must be between 100 Ω and 2.5 k Ω for maximum open position.
Auxiliary
output
Number of outputs2 or 3 max.
Output 
specifications
Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
Event
input
Number of outputs2 or 4 (with an E53-AKB)
External contact 
input specifications
Contact input: ON: 1 k Ω max., OFF: 100 k Ω min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
 

View Complete Details

Yes, I am interested!

Digital Controller E5AR
Interested in this product?
Get Best Quote

Digital Controller E5AR

Get Latest Price

Specifications: 

Ratings

 

Supply voltage
(See note 1.)
100 to 240 VAC, 50/60 Hz24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption22 VA max. (with maximum load)15 VA/10 W max. (with maximum load)
Sensor input (See note 2.)Thermocouple: K, J, T, E, L, U, N, R, S, B, W
Platinum resistance thermometer: Pt100
Current input: 4 to 20 mA DC, 0 to 20 mA DC (including remote SP input)
Voltage input: 1 to 5 VDC, 0 to 5 VDC, 0 to 10 VDC (including remote SP input)
(Input impedance: 150 Ω for current input, approx. 1 MΩ for voltage input)
Control outputVoltage (pulse)
output
12 VDC, 40 mA max. with short-circuit protection circuit (E5AR-QQ[]WW-[]: 21 mA max.)
Current output0 to 20 mA DC, 4 to 20 mA DC; load: 500 Ω max. (including transfer output)
(Resolution: Approx. 54,000 for 0 to 20 mA DC; Approx. 43,000 for 4 to 20 mA DC)
Relay outputPosition-proportional control type (open, closed)
N.O., 250 VAC, 1 A (including inrush current)
Auxiliary outputRelay Output
N.O., 250 VAC, 1 A (resistive load)
Potentiometer input100 Ω to 2.5 kΩ
Event inputContactInput ON: 1 kΩ max.; OFF: 100 kΩ min.
No-contactInput ON: Residual voltage of 1.5 V max.; OFF: Leakage current of 0.1 mA max.
Event inputShort-circuit: Approx. 4 mA
Remote SP inputRefer to the information on sensor input.
Transfer outputRefer to the information on control output.
Control method2-PID or ON/OFF control
Setting methodDigital setting using front panel keys or setting using serial communications
Indication method7-segment digital display and single-lighting indicator
Character Height
PV: 12.8 mm; SV: 7.7 mm; MV: 7.7 mm
Other functionsDepends on model.
Ambient operating temperature-10 to 55°C (with no icing or condensation)
For 3 years of assured use: -10 to 50°C (with no icing or condensation)
Ambient operating humidity25% to 85%
Storage temperature-25 to 65°C (with no icing or condensation)
 

View Complete Details

Yes, I am interested!

Digital Controllers E5ER
Interested in this product?
Get Best Quote

Digital Controllers E5ER

Get Latest Price

Specifications

Ratings

Supply voltage
(See note 1.)
100 to 240 VAC, 50/60 Hz24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption17 VA max. (with maximum load)11 VA/7 W max. (with maximum load)
Sensor input
(See note 2.)
Thermocouple K, J, T, E, L, U, N, R, S, B, W
Platinum resistance thermometer Pt100
Current input 4 to 20 mA DC, 0 to 20 mA DC (including remote SP input)
Voltage input 1 to 5 VDC, 0 to 5 VDC, 0 to 10 VDC (including remote SP input)
(Input impedance 150 for current input, approx. 1 M for voltage input)
Control
output
Voltage (pulse)
output
12 VDC, 40 mA max. with short-circuit protection circuit
Current output0 to 20 mA DC, 4 to 20 mA DC; load 500 max. (including transfer output)
(Resolution Approx. 54,000 for 0 to 20 mA DC; Approx. 43,000 for 4 to 20 mA DC)
Relay outputPosition-proportional control type (open, closed)
N.O., 250 VAC, 1 A (including inrush current)
Auxiliary outputRelay Output
N.O., 250 VAC, 1 A (resistive load)

Transistor Output
Maximum load voltage 30 VDC; Maximum load current 50 mA; Residual voltage 1.5 V max.; Leakage current 0.4 mA max.
Potentiometer input100 to 2.5 k
Event inputContactInput ON 1 k max.; OFF 100 k min.
No-contactInput ON Residual voltage of 1.5 V max.; OFF Leakage current of 0.1 mA max.
Event inputShort-circuit Approx. 4 mA
Remote SP inputRefer to the information on sensor input.
Transfer outputRefer to the information on control output.
Control method2-PID or ON/OFF control
Setting methodDigital setting using front panel keys or setting using serial communications
Indication method7-segment digital display and single-lighting indicator
Character Height
PV 9.5 mm; SV 7.2 mm; MV 7.2 mm
Other functionsDepends on model.
Ambient operating temperature-10 to 55 DegreeC (with no icing or condensation)
For 3 years of assured use -10 to 50 DegreeC (with no icing or condensation)
Ambient operating humidity25% to 85%
Storage temperature-25 to 65 DegreeC (with no icing or condensation)

View Complete Details

Yes, I am interested!

Programmable Digital Controller E5AR-T
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Supply
voltage *2
CE marking100 to 240 VAC, 50/60 Hz24 VAC, 50/60 Hz; 24 VDC
UL certification100 to 120 VAC, 50/60 Hz
Operating voltage range85% to 110% of rated supply voltage
Power consumption22 VA max. (with maximum load)15 VA/10 W max. (with maximum load)
Sensor input *3Thermocouple: K, J, T, E, L, U, N, R, S, B, W
Platinum resistance thermometer: Pt100
Current input: 4 to 20 mA DC, 0 to 20 mA DC (including remote SP input)
Voltage input: 1 to 5 VDC, 0 to 5 VDC, 0 to 10 VDC (including remote SP input)
(Input impedance: 150 Ω for current input, approx. 1 MΩ for voltage input)
Control
output
Voltage (pulse)
output
12 VDC, 40 mA max. with short-circuit protection circuit (E5AR-TQQE3MW-FLK: 21 mA max.)
Current output0 to 20 mA DC, 4 to 20 mA DC; load: 500 Ω max. (including transfer output)
(Resolution: Approx. 54,000 for 0 to 20 mA DC; Approx. 43,000 for 4 to 20 mA DC)
Relay outputPosition-proportional control type (open, closed)
N.O., 250 VAC, 1 A (including inrush current)
Auxiliary outputRelay Output
N.O., 250 VAC, 1 A (resistive load)
Transistor Output
Maximum load voltage: 30 VDC; Maximum load current: 50 mA; Residual voltage: 1.5
V max.; Leakage current: 0.4 mA max.
Potentiometer input100 Ω to 2.5 kΩ
Event inputContactInput ON: 1 kΩ max.; OFF: 100 kΩ min.
No-contactInput ON: Residual voltage of 1.5 V max.; OFF: Leakage current of 0.1 mA max.
Event inputShort-circuit: Approx. 4 mA
Remote SP inputRefer to the information on sensor input.
Transfer outputRefer to the information on control output.
Control method2-PID or ON/OFF control
Setting methodDigital setting using front panel keys or setting using serial communications
Indication method7-segment digital display and single-lighting indicator
Character Height
PV display: 12.8 mm; SV display: 7.7 mm; MV display: 7.7 mm
Other functionsDepends on model.
Ambient operating temperature-10 to 55°C (with no icing or condensation)
For 3 years of assured use: -10 to 50°C (with no icing or condensation)
Ambient operating humidity25% to 85%
Storage temperature-25 to 65°C (with no icing or condensation)
 

View Complete Details

Yes, I am interested!

Programmable Digital Controller E5ER-T
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Supply
voltage *2
CE Marking100 to 240 VAC, 50/60 Hz24 VAC, 50/60 Hz; 24 VDC
UL certification100 to 120 VAC, 50/60 Hz
Operating voltage range85% to 110% of rated supply voltage
Power consumption17 VA max. (with maximum load)11 VA/7 W max. (with maximum load)
Sensor input *3Thermocouple: K, J, T, E, L, U, N, R, S, B, W
Platinum resistance thermometer: Pt100
Current input: 4 to 20 mA DC, 0 to 20 mA DC (including remote SP input)
Voltage input: 1 to 5 VDC, 0 to 5 VDC, 0 to 10 VDC (including remote SP input)
(Input impedance: 150 Ω for current input, approx. 1 MΩ for voltage input)
Control
output
Voltage (pulse)
output
12 VDC, 40 mA max. with short-circuit protection circuit
Current output0 to 20 mA DC, 4 to 20 mA DC; load: 500 Ω max. (including transfer output)
(Resolution: Approx. 54,000 for 0 to 20 mA DC; Approx. 43,000 for 4 to 20 mA DC)
Relay outputPosition-proportional control type (open, closed)
N.O., 250 VAC, 1 A (including inrush current)
Auxiliary outputRelay Output
N.O., 250 VAC, 1 A (resistive load)
Transistor Output
Maximum load voltage: 30 VDC; Maximum load current: 50 mA; Residual voltage: 1.5
V max.; Leakage current: 0.4 mA max.
Potentiometer input100 Ω to 2.5 kΩ
Event inputContactInput ON: 1 kΩ max.; OFF: 100 kΩ min.
No-contactInput ON: Residual voltage of 1.5 V max.; OFF: Leakage current of 0.1 mA max.
Event inputShort-circuit: Approx. 4 mA
Remote SP inputRefer to the information on sensor input.
Transfer outputRefer to the information on control output.
Control method2-PID or ON/OFF control
Setting methodDigital setting using front panel keys or setting using serial communications
Indication method7-segment digital display and single-lighting indicator
Character Height
PV display: 9.5 mm; SV display: 7.2 mm; MV display: 7.2 mm
Other functionsDepends on model.
Ambient operating temperature-10 to 55°C (with no icing or condensation)
For 3 years of assured use: -10 to 50°C (with no icing or condensation)
Ambient operating humidity25% to 85%
Storage temperature-25 to 65°C (with no icing or condensation)
 

View Complete Details

Yes, I am interested!

Temperature Controllers E5CS
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Supply voltage100 to 240 VAC, 50/60 Hz 
24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption100 to 240 VAC: 5 VA 
24 VAC: 3 VA, 24 VDC: 2 W
Sensor inputThermocouple: K, J, L 
Platinum resistance thermometer: Pt100, JPt100 
Thermistor: E52-THE[][] 
Universal-input (thermocouple/platinum resistance thermometer): K, J, L, T, U, N, 
R, Pt100, JPt100
Control 
output
Relay outputSPDT, 250 VAC, 3 A (resistive load)
Voltage output 
(for driving the SSR)
12 VDC, 21 mA (with short-circuit protection circuit)
Control methodON/OFF or 2-PID (with automatic PID parameter setting function)
Alarm outputSPST-NO, 250 VAC, 1A (resistive load)
Setting methodDigital setting using front panel keys
Indication method7-segment digital display (character height: 13.5 mm) and deviation indicators
Other functionsSetting change prohibit (key protection) 
Input shift 
Temperature unit change (°C/°F) 
Direct/reverse operation 
Temperature range, Sensor switching (K/J/L, Pt100/JPt100) 
Switching is performed between a thermocouple and platinum resistance 
thermometer for universal-input models. 
Control period switching 
8-mode alarm output 
Sensor error detection (excluding thermistor models)
Ambient operating temperature-10 to 55°C (with no condensation or icing); with 3-year guarantee: -10 to 50°C
Ambient operating humidity25% to 85%
Storage temperature-25 to 65°C (with no condensation or icing)
 

View Complete Details

Yes, I am interested!

Basic-Type Digital Temperature Controller (48 x 24 mm) E5GN
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageNo D in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power
consump-
tion
E5GN
Screw terminal
block
100 to 240 VAC: 5.5 VA (max.)
24 VAC/VDC: 3 VA/2 W (max.)
E5GN-[]-C
Screwless clamp
terminal block
100 to 240 VAC: 5.5 VA (max.)
24 VAC/VDC: 3 VA/2 W (max.)
Sensor inputModels with temperature inputs
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
Voltage input: 0 to 50 mV
Models with analog inputs
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB.)
Control methodON/OFF control or 2-PID control (with auto-tuning)
Control
outputs
Relay outputSPST-NO, 250 VAC, 2 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V,
10 mA
Voltage output
(for driving SSR)
Output voltage: 12 VDC ± 15% (PNP), max. load current: 21 mA, with short-circuit protection circuit
Current output4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Auxiliary
outputs
Number of outputs1 or 2 max. (Depends on the model.)
Output
specifications
Relay output: SPST-NO, 250 VAC, 2 A (resistive load), electrical life: 100,000 operations, minimum
applicable load: 5 V, 10 mA
 

View Complete Details

Yes, I am interested!

Basic-Type Digital Temperature Controller (48 x 48 mm)E5CN
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageNo D in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power
consumption
E5CN100 to 240 VAC: 7.5 VA (max.) (E5CN-R2T at 100 VAC: 3.0 VA)
24 VAC/VDC: 5 VA/3 W (max.) (E5CN-R2TD at 24 VAC: 2.7 VA)
E5CN-U100 to 240 VAC: 6 VA (max.)
24 VAC/VDC: 3 VA/2 W (max.) (models with current output: 4 VA/2 W)
Sensor inputModels with temperature inputs
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
Voltage input: 0 to 50 mV
Models with analog inputs
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB.)
Control methodON/OFF control or 2-PID control (with auto-tuning)
Control
outputs
Relay outputE5CNSPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum
applicable load: 5 V, 10 mA
E5CN-USPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable
load: 5 V, 10 mA
Voltage output
(for driving SSR)
E5CN
E5CN-U
Output voltage: 12 VDC ± 15% (PNP), max. load current: 21 mA, with short-circuit protection
circuit
Current outputE5CN4 to 20 mA DC/0 to 20 mA DC, load: 600 Ω max., resolution: approx. 10,000
Long-life relay
output
E5CNSPST-NO, 250 VAC, 3 A (resistive load), electrical life: 1,000,000 operations, load power
supply voltage: 75 to 250 VAC (DC loads cannot be connected.), minimum applicable load: 5 V,
10 mA, leakage current: 5 mA max. (250 VAC, 60 Hz)
 

View Complete Details

Yes, I am interested!

Basic-Type Digital Temperature Controller E5AN, E5EN
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageNo D in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption100 to 240 VAC: 10 VA
24 VAC/VDC: 5.5 VA (24 VAC)/4 W (24 VDC)
Sensor inputModels with temperature inputs
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
Voltage input: 0 to 50 mV
Models with analog inputs
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB.)
Control methodON/OFF control or 2-PID control (with auto-tuning)
Control
output
Relay outputSPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V,
10 mA
Voltage output
(for driving SSR)
Output voltage: 12 VDC ± 15% (PNP), max. load current: 40 mA,
With short-circuit protection circuit: Max. load current of 21 mA for control output 2
Current output4 to 20 mA DC/0 to 20 mA DC, load: 600 Ω max., resolution: approx. 10,000
Long-life relay 
output
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 1,000,000 operations, load power supply voltage:
75 to 250 VAC (DC loads cannot be connected.), minimum applicable load: 5 V, 10 mA, leakage current:
5 mA max. (250 VAC, 60 Hz)
Auxiliary
output
Number of outputs3
Output 
specifications
Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum
applicable load: 5 V, 10 mA
 

View Complete Details

Yes, I am interested!

Programmable Temperature Controller E5CN-HT
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageNo D in model number: 100 to 240 VAC, 50/60 Hz 
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption100 to 240 VAC: 8.5 VA (max.) (E5CN-HTR2 at 100 VAC: 3.0 VA) 
24 VAC/VDC: 5.5 VA (24 VAC)/3.5 W (24 VDC) (max.) (E5CN-HTR2D at 24 VAC: 2.7 VA)
Sensor inputAny of the following can be selected (i.e., fully universal input). 
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II 
Platinum resistance thermometer: Pt100 or JPt100 
Current input: 4 to 20 mA or 0 to 20 mA 
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the 
ES2-HB.)
Control methodON/OFF control or 2-PID control (with auto-tuning)
Control 
output
Relay outputSPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, 
minimum applicable load: 5 V, 10 mA
Voltage output 
(for driving SSR)
Output voltage: 12 VDC ± 15% (PNP), max. load current: 21 mA, with short-circuit protection circuit
Current output4 to 20 mA DC/0 to 20 mA DC, load: 600 Ω max., resolution: approx. 10,000 *
Linear voltage output0 to 10 VDC (load: 1 kΩ min.), Resolution: Approx. 10,000
Auxiliary 
output
Number of outputs2 max.
Output specificationsRelay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum 
applicable load: 5 V, 10 mA
Event 
input
Number of outputs2
External contact 
input specifications
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
 

View Complete Details

Yes, I am interested!

Digital Temperature Controllers
Interested in this product?
Get Best Quote
Specifications: 

E5CZ/E5CZ-U Digital Temperature ControllersRatings

 

Power supply voltage100 to 240 VAC, 50/60 Hz24 VAC, 50/60 Hz or 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power 
con- 
sumption
E5CZ7.5 VA5.5 VA (24 VAC)/3.5 W (24 VDC)
E5CZ-U6 VA4.5 VA (24 VAC)/2.5 W (24 VDC)
Sensor inputModels with temperature inputs 
Thermocouple: K, J, T, E, L, U, N, R, S, or B 
Platinum resistance thermometer: Pt100 or JPt100 
Infrared temperature sensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C 
Voltage input: 0 to 50 mV
Models with analog inputs 
Current input: 4 to 20 mA or 0 to 20 mA 
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω, Voltage input: 1 MΩ (Use a 1:1 connection when connecting the 
ES2-HB.)
Control 
output
Relay outputE5CZ: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, 
minimum applicable load: 5 V, 10 mA
E5CZ-U: SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, 
minimum applicable load: 5 V, 10 mA
Voltage output 
(for driving SSR)
E5CZ/E5CZ-U: Output voltage: 12 VDC ±15% (PNP), max. load current: 21 mA, with 
short-circuit protection circuit
Current outputE5CZ: 4 to 20 mA DC/0 to 20 mA DC, load: 600 Ω max., resolution: approx. 2,700
Alarm outputSPST-NO, 250 VAC, 1 A (resistive load), electrical life: 100,000 operations, minimum 
applicable load: 5 V, 10 mA
Event 
input
Contact inputON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact inputON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Event inputOutflow current: Approx. 7 mA per point
Control methodON/OFF control or 2-PID control (with auto-tuning)
Setting methodDigital setting using front panel keys
Indication method11-segment digital display and individual indicators (7-segments displays also 
possible) 
Character height: PV: 11 mm, SV: 6.5 mm
Other functionsManual output, heating/cooling control, transfer output (on some models), loop break 
alarm, multi SP, MV limiter, input digital filter, self-tuning, temperature input shift, 
run/stop, protection functions, etc.
Ambient operating 
temperature
-10 to 55°C (with no icing or condensation)
Ambient operating humidity25% to 85%
Storage temperature-25 to 65°C (with no icing or condensation)
 

View Complete Details

Yes, I am interested!

Temperature Controllers E5CSV
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Supply voltage100 to 240 VAC, 50/60 Hz 
24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption100 to 240 VAC: 5 VA 
24 VAC: 3 VA, 24 VDC: 2 W
Sensor inputThermocouple input type: K, J, L 
Platinum resistance thermometer input type: Pt100, JPt100 
Universal-input (thermocouple/platinum resistance thermometer) type: K, J, L, T, U, N, R, Pt100, JPt100
Control
output
Relay outputSPST-NO, 250 VAC, 3A (resistive load)
Voltage output 
(for driving the SSR)
12 VDC, 21 mA (with short-circuit protection circuit)
Control methodON/OFF or 2-PID (with auto-tuning)
Alarm outputSPST-NO, 250 VAC, 1A (resistive load)
Setting methodDigital setting using front panel keys
Indication method7-segment digital display (character height: 13.5 mm) and deviation indicators
Other functionsSetting change prohibit (key protection) 
Input shift 
Temperature unit change (°C/°F) 
Direct/reverse operation 
Temperature range, Sensor switching (K/J/L, Pt100/JPt100) 
Switching is performed between a thermocouple and platinum resistance thermometer for universal-input models. 
Control period switching 
8-mode alarm output 
Sensor error detection
Ambient operating 
temperature
-10 to 55°C (with no condensation or icing); with 3-year guarantee: -10 to 50°C
Ambient operating humidity25% to 85%
Storage temperature-25 to 65°C (with no condensation or icing)

 

View Complete Details

Yes, I am interested!

Digital Temperature Controller E5AC-800
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageA in model number: 100 to 240 VAC, 50/60 Hz 
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption7.0 VA max. at 100 to 240 VAC, and 4.2 VA max. at 24 VAC or 2.4 W max. at 24 VDC
Sensor inputTemperature input 
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II 
Platinum resistance thermometer: Pt100 or JPt100 
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 
to 260°C 
Analog input 
Current input: 4 to 20 mA or 0 to 20 mA 
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. 
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control methodON/OFF control or 2-PID control (with auto-tuning)
Control 
output
Relay outputSPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations, 
minimum applicable load: 5 V, 10 mA
Voltage output 
(for driving SSR)
Output voltage: 12 VDC ± 20% (PNP), max. load current: 40 mA, with short-circuit 
protection circuit (The maximum load current is 21 mA for models with two control 
outputs.)
Linear current 
output
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Auxiliary
output
Number of outputs1, 2, or 3 (depends on model)
Output 
specifications
SPST-NO relay outputs, 250 VAC, Models with 2 outputs: 3 A (resistive load), 
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V
Event 
input
Number of inputs2 or 4 (depends on model)
External contact 
input 
specifications
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Potentiometer input100 Ω to 10 kΩ
Setting methodDigital setting using front panel keys
Indication method11-segment digital display and individual indicators 
Character height: PV: 25.0 mm, SV: 15.0 mm
 

View Complete Details

Yes, I am interested!

Digital Temperature Controller E5CC-800
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageA in model number: 100 to 240 VAC, 50/60 Hz 
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumptionModels with option selection of 000:5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at 
24 VAC or 1.6 W max. at 24 VDC 
All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W 
max. at 24 VDC
Sensor inputTemperature input 
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II 
Platinum resistance thermometer: Pt100 or JPt100 
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 
140 to 260°C 
Analog input 
Current input: 4 to 20 mA or 0 to 20 mA 
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. 
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control methodON/OFF control or 2-PID control (with auto-tuning)
Control 
output
Relay outputE5CC-800: 
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum 
applicable load: 5 V, 10 mA 
E5CC-U-800: 
SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum 
applicable load: 5 V, 10 mA
Voltage output 
(for driving SSR)
Output voltage: 12 VDC ± 20% (PNP), max. load current: 21 mA, with short-circuit 
protection circuit
Linear current 
output
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Auxiliary
output
Number of outputs2
Output 
specifications
SPST-NO relay outputs, 250 VAC, Models with 2 outputs: 3 A (resistive load), 
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V
Event 
input
Number of inputs2 or 4 (depends on model)
External contact 
input 
specifications
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Setting methodDigital setting using front panel keys
 

View Complete Details

Yes, I am interested!

Digital Temperature Controller E5EC-800
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageA in model number: 100 to 240 VAC, 50/60 Hz 
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption6.6 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC
Sensor inputTemperature input 
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II 
Platinum resistance thermometer: Pt100 or JPt100 
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 
260°C 
Analog input 
Current input: 4 to 20 mA or 0 to 20 mA 
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. 
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control methodON/OFF control or 2-PID control (with auto-tuning)
Control 
output
Relay outputSPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations, 
minimum applicable load: 5 V, 10 mA
Voltage output 
(for driving SSR)
Output voltage: 12 VDC ± 20% (PNP), max. load current: 40 mA, with short-circuit 
protection circuit (The maximum load current is 21 mA for models with two control 
outputs.)
Linear current 
output
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Auxiliary
output
Number of outputs1, 2, or 3 (depends on model)
Output 
specifications
SPST-NO relay outputs, 250 VAC, Models with 2 outputs: 3 A (resistive load), 
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V
Event 
input
Number of inputs2 or 4 (depends on model)
External contact 
input 
specifications
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Potentiometer input100 Ω to 10 kΩ
Setting methodDigital setting using front panel keys
Indication method11-segment digital display and individual indicators 
Character height: PV: 18.0 mm, SV: 11.0 mm
Multi SPUp to eight set points (SP0 to SP7) can be saved and selected using event inputs, key 
operations, or serial communications.
Bank switchingNone
Other functionsManual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm 
functions, heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 
100% AT, MV limiter, input digital filter, self tuning, PV input shift, run/stop, protection 
functions, temperature status display, moving average of input value, FB moving 
average
 

View Complete Details

Yes, I am interested!

Programmable Temperature Controller E5AN-HT, E5EN-HT
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageNo D in model number: 100 to 240 VAC, 50/60 Hz 
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption100 to 240 VAC: 12 VA 
24 VAC/VDC: 8.5 VA (24 VAC)/5.5 W (24 VDC)
Sensor inputAny of the following can be selected. 
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II 
Platinum resistance thermometer: Pt100 or JPt100 
Current input: 4 to 20 mA or 0 to 20 mA 
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection 
when connecting the ES2-HB.)
Control methodON/OFF control or 2-PID control (with auto-tuning)
Control 
output
Relay outputOutput Unit (Install the Output Unit (sold separately).)
Voltage output 
(for driving SSR)
Current output
Linear voltage output
Relay output for 
position-proportional 
control
Relay output: Open and close: SPST-NO, 250 VAC, 1 A (including in-rush 
current), electrical life: 100,000 operations min. 
Potentiometer input: Must be between 100 Ω and 2.5 kΩ for maximum open 
position.
Auxiliary 
output
Number of outputs2 or 3 max.
Output specificationsRelay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 
operations, minimum applicable load: 5 V, 10 mA
Event 
input
Number of outputs2 or 4 (with an E53-AKB)
External contact 
input specifications
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 
mA max.
Current flow: Approx. 7 mA per contact
Logic 
operations
Number of operations8 max.
OperationsLogic operation: 
Any of the following four patterns can be selected. The input status may be 
inverted. (A and B) or (C and D), (A or C) and (B or D), A or B or C or D, A and B 
and C and D (A, B, C, and D are four inputs.) 
Delay: 
ON delay or OFF delay for the results of the logic operation given above. 
Setting time: 0 to 9999 s or 0 to 9999 min 
Output inversion: Possible
OutputOne work bit per operation
Work bit 
assignment
Any of The following can be assigned to up to eight work bits (logic operation 
results): operation commands (assigned to event inputs)* , auxiliary outputs, or 
control outputs. 
* Application is possible with models that do not have event inputs by using an 
internal assignment.
 

View Complete Details

Yes, I am interested!

Temperature Controller E5C2
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Supply voltage100 to 240 VAC 50/60 Hz
Operating voltage range90% to 110% of rated supply voltage
Power consumptionApprox. 3.6 VA
InputThermocouple (with sensor burnout detection circuit), 
platinum resistance thermometer, or thermistor with replaceable element
Control modeON/OFF or proportional control
Setting methodAnalog setting
Indication methodNo indication
Control outputRelay output: SPDT, 3 A at 250 VAC, resistive load (switching capacity: 330 VA)
Ambient operating temperature- 10°C to 55°C (with no icing or condensation)
Ambient operating humidity45% to 85%

 

Note: Do not use an inverter output as the power supply. (Refer to Safety Precautions for All Temperature Controllers.)

Characteristics

 

Setting accuracy±2% FS max.
HysteresisApprox. 0.5% FS (fixed)
Proportional band3% FS (fixed)
Control periodApprox. 20 s
Reset range5 ±1% FS min. *1
Insulation resistance20 MΩ min. (at 500 VDC)
Dielectric strength2,000 VAC, 50/60 Hz for 1 min between charged terminals and uncharged metallic parts
Vibration resistanceMalfunction: 10 to 55 Hz, 0.15-mm single amplitude for 10 min each in X, Y, and Z directions 
Destruction: 16.7 Hz, 2-mm double amplitude for 2 hrs each in X, Y, and Z directions
Shock resistanceMalfunction: 147 m/s2, 3 times each in 6 directions 
Destruction: 294 m/s2, 3 times each in 6 directions
Life expectancyElectrical: 100,000 operations min. (3 A at 110 VAC, resistive load)
WeightApprox. 100 g (with flush-mounting adapter)
Degree of protectionFront panel: IEC standard IP40 *2 
Terminals: IEC standard IP00
Applicable SocketP2CF-08 (order separately), 
P3G-08 (order separately)
Applicable Protective 
Cover
Y92A-48B (order separately)
 

View Complete Details

Yes, I am interested!

Electronic Thermostat E5L
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

ModelE5L-A[]E5L-C[]
Power supply voltage100 to 240 VAC, 50/60 Hz
Operating voltage range85% to 110% of the rated supply voltage
Power consumptionApprox. 3 VA
InputsElement-interchangeable thermistor
Control methodON/OFF control
Control outputSPDT contacts, 250 VAC, 10 A, cosΦ = 1
(resistive load)
SPST-NO contacts, 250 VAC, 10 A, cosΦ = 1
(resistive load)
Setting methodAnalog settingDigital settings using keys on front panel
Indication methodNo displayLCD digital display (character height: 12 mm)
Other functionsSetting protection (key protection)
Input shift
Direct/reverse operation
Ambient temperature-10 to 55°C (with no icing or condensation)
Ambient humidity25% to 85%
Storage temperature-25°C to 65°C (with no icing or condensation)

 

Note: Do not use the output from an Inverter as the power supply.

Characteristics

 

ModelE5L-A[]E5L-C[]
Indication accuracy---±(1°C 1 digit) max.*
Setting accuracy---±(1°C 1 digit) max.*
Hysteresis-30 to 20°C models: Approx. 0.5 to 2.5°C 
(variable) 
0 to 50°C models: Approx. 0.5 to 4°C 
(variable) 
0 to 100°C models: Approx. 0.5 to 4°C 
(variable) 
100 to 200°C models: Approx. 0.7 to 4°C 
(variable)
1 to 9°C (in increments of 1°C)
Repeat accuracy1% FS max.---
Minimum scale 
(standard scale)
-30 to 20°C models and 0 to 50°C models: 
5°C 
0 to 100°C models and 100 to 200°C 
models: 10°C
---
Influence of 
temperature
---±((1% of PV or 2°C, whichever is greater) 
1 digit) max.
Influence of voltage---
Sampling period---2 s
Insulation resistance100 MΩ max. (at 500 VDC)
Dielectric strength2,300 VAC, 50/60 Hz for 1 min (between charged terminals and uncharged metallic parts, 
between power supply terminals and input terminals, between power supply terminals and 
output terminals, and between input terminals and output terminals)
 

View Complete Details

Yes, I am interested!

Temperature Controllers E5CSL / E5CWL / E5EWL
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltage100 to 240 VAC, 50/60 Hz
Operating voltage range85% to 110% of rated supply voltage
Power consumption3.5 VA
Sensor inputModels with thermocouple inputs 
Thermocouple: K, J, T, R, or S
Models with platinum resistance thermometer inputs 
Platinum resistance thermometer: Pt100
Control 
output
Relay outputSPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, 
minimum load: 5 V, 10 mA
Voltage output 
(for driving SSR)
Output voltage: 12 VDC 25%/-15% (PNP), max. load current: 21 mA, with short- 
circuit protection circuit
Alarm output *SPST-NO, 250 VAC, 1 A (resistive load), electrical life: 100,000 operations, minimum load: 5 V, 10 mA
Control methodON/OFF control or 2-PID control (with auto-tuning)
Setting methodDigital setting using front panel keys
Indication method7-segment digital display and individual indicators 
Character height: E5CSL: 21.7 mm, E5CWL: 16.2 mm (PV), E5EWL: 20 mm (PV)
Other functionsTemperature input shift, run/stop, protection functions, etc.
Ambient operating temperature-10 to 55°C (with no icing or condensation)
Ambient operating humidity25% to 85%
Storage temperature-25 to 65°C (with no icing or condensation)
 

View Complete Details

Yes, I am interested!

Modular Temperature Controller EJ1
Interested in this product?
Get Best Quote
Specifications: 

Basic Unit/EJ1N-TCRatings

 

TypeEJ1N-TC4EJ1N-TC2
Power supply voltage24 VDC
Operating voltage range85% to 110% of rated voltage
Power consumption5 W max. (at maximum load)4 W max. (at maximum load)
Input *Thermocouple: K, J, T, E, L, U, N, R, S, B, W, PLII 
ES1B Infrared Thermosensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, 140 to 260°C 
Analog input: 4 to 20 mA, 0 to 20 mA, 1 to 5 V, 0 to 5 V, 0 to 10 V 
Platinum resistance thermometer: Pt100, JPt100
Input impedanceCurrent input: 150 Ω max., voltage input: 1 MΩ min.
Control 
outputs
Voltage 
output
Output voltage: 12 VDC ±15%, max. load current: 21 mA (PNP models with short-circuit 
protection circuit)
Transistor 
output
---Max. operating voltage: 30 V, max. load current: 100 mA
Current 
output
---Current output range: 4 to 20 mA or 0 to 20 mA DC 
Load: 500 Ω max. (including transfer output) 
(Resolution: Approx. 2,800 for 4 to 20 mA DC, approx. 
3,500 for 0 to 20 mA DC)
Event 
inputs
Input points---2
Contact input---ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact 
input
---ON: Residual voltage: 1.5 V max., 
OFF: Leakage current: 0.1 mA max.
Event inputs---Outflow current: Approx. 4 mA per point
Number of input and 
control points
Input points: 4, Control points: 4Input points: 2, Control points: 2
Setting methodVia communications
Control methodON/OFF control or 2-PID (with autotuning, self-tuning) [V1.2]
Other functionsTwo-point input shift, digital input filter, remote SP, SP ramp, manual manipulated variable, 
manipulated variable limiter, interference overshoot adjustment, loop burnout alarm, RUN/ 
STOP, banks, I/O allocations, etc.
Ambient 
temperature range
Operating: -10°C to 55°C, Storage: -25°C to 65°C (with no icing or condensation)
Ambient humidity rangeOperating: 25% to 85% (with no condensation)
 

View Complete Details

Yes, I am interested!

Modular Temperature Controller E5ZN
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltage24 VDC
Allowable voltage range85% to 110% of the rated power supply voltage
Power consumptionApprox. 3 W
Sensor inputThermocouple: K, J, T, E, L, U, N, R, S, B
Infrared temperature sensor (ES1B series): 10 to 70℃, 60 to 120℃, 115 to 165℃, 140 to 260℃
Voltage input: 0 to 50 Mv
Platinum resistance thermometer: Pt100, JPt100
Control outputVoltage output
(for driving SSR)
Output voltage: 12 VDC ±15% (PNP);
Maximum load current: 21 mA;
Equipped with short-circuit protection circuit
Transistor outputMaximum operational voltage: 30 VDC;
Maximum load current: 100 mA; 
Residual voltage: 1.5 V max.; 
Leakage current: 0.4 mA max.
Current outputCurrent output range: 4 to 20/0 to 20 mA DC;
Load: 350 Ω max. (See note 2.)
Auxiliary outputTransistor outputSourcingMaximum operating voltage: 30 VDC;
Maximum load current: 50 mA;
Residual voltage: 1.5 V max.;
Leakage current: 0.4 mA max.
Sinking
Linear voltage outputVoltage output range: 1 to 5/0 to 5 VDC;
Load: 10 kΩ min.
Event inputContact outputON: 1 kΩ max., OFF: 100 kΩ min. 
Discharge current: Approx. 7 mA
Non-contact outputON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. 
Discharge current: Approx. 7 mA
Number of input and control
points
Input points: 2, Control points: 2
Setting methodVia communications or using the Setting Display Unit (E5ZN-SDL)
Control method2-PID or ON/OFF control
Other functionsHeater burnout detection function, transfer output function 
Multi-SP and RUN/STOP switching using event input
Ambient operating temperature-10 to 55℃ (with no icing or condensation) 
For 3 years of assured use: -10 to 50℃
Ambient operating humidity25% to 85%
Storage temperature-25 to 65℃ (with no icing or condensation)
 

View Complete Details

Yes, I am interested!

Device Net Communications Unit E5ZN-DRT
Interested in this product?
Get Best Quote
Specifications: 

Ratings

 

Power supply voltageDeviceNet24 VDC (for internal circuits)
External input power supply24 VDC (for RS-485 communications circuits and Temperature Controllers)
Allowable voltage rangeDeviceNet11 to 25 VDC
External input power supply20.4 to 26.4 VDC
Power consumption
(See note 2.)
DeviceNetApprox. 1.1 W (for a current of 45 mA at 24 VDC)
External input power supplyApprox. 0.5 W (for a current of 20 mA at 24 VDC)
Connectable Temperature ControllersE5ZN Series
Maximum number of connectable Temperature Controllers16
Ambient operating temperature-10 to 55°C (with no icing or condensation)
Ambient operating humidity25% to 85%
Ambient storage temperature-25 to 65°C (with no icing or condensation)
 

View Complete Details

Yes, I am interested!

CJ Series Temperature Control Unit CJ1W-TC
Interested in this product?
Get Best Quote
Specifications: 

General Specifications

 

ItemSpecification
Unit classificationCJ-series Special I/O Unit
Compatible RacksCJ-series CPU Rack or CJ-series Expansion Rack
Max. number of
Units
10 Units/Rack max. (CPU Rack or Expansion Rack)
CPU Unit data
areas for data
storage/exchange
Special I/O Unit Area
(960 words)
CIO 2000 to CIO 2959
20 words/Unit for
constant data
exchange (6 output
words and 14
input words)
CPU Unit to
Temperature
Control Unit
Set point (SP)
Operating commands
RUN/STOP control
Start/Stop AT
Write commands
Heater burnout set value
Temperature
Control Unit
to CPU Unit
Process value (PV)
Set point (SP)
Status
Heater current monitor
DM words allocated to
Special I/O Units
(9,600 words)
D20000 to D29599
10 words/Unit
transferred when
power is turned ON or
Unit is restarted
CPU Unit to
Temperature
Control Unit
Alarm mode
Alarm hysteresis
90 words/Unit for regular
data exchange
Two-way
transfer
between CPU
Unit and
Temperature
Control Unit
Alarm value
Input compensation value
Control period
Hysteresis
Proportional band
Integral time
Derivative time
Output monitor
Insulation
resistance
20 M Ω min. (at 500 VDC) between the following points:
All output and NC terminals and external AC terminals (Power Supply Unit)
All input terminals and external AC terminals (Power Supply Unit)
All input terminals and all output terminals
All external DC terminals (inputs, outputs, and NC) and the FG plate
Between input terminals (sensor and CT inputs)
I/O terminals and NC terminals
Dielectric strength2,000 VAC 50/60 Hz for 1 min., detected current: 1 mA
The output terminals/NC terminals and external AC terminals (Power Supply Unit)
1,000 VAC 50/60 Hz for 1 min., detected current: 1 mA
Input terminals and external AC terminals (Power Supply Unit)
Input terminals and output terminals
External DC terminals (inputs, outputs, and NC) and the FG plate
500 VAC 50/60 Hz for 1 min., detected current: 1 mA
Between input terminals (sensor and CT inputs)
I/O terminals and NC terminals
 

View Complete Details

Yes, I am interested!

CX-Thermo Support Software EST2-2C-MV4
Interested in this product?
Get Best Quote
Specifications: 

mpatible 
devices
Temperature 
Controllers
E5GN * (available from Sep. 2009) 
E5CN (available from April 2004) 
E5EN,E5AN(available from February 2005), 
E5CN-H, E5EN-H, E5AN-H 
E5CN-HT, E5EN-HT, E5AN-HT 
E5ER, E5AR 
E5ER-T, E5AR-T 
E5CC, E5EC, E5AC, E5DC 
E5CC-T, E5EC-T, E5AC-T 
E5ZN 
EJ1N-TC4, EJ1N-TC2, EJ1N-HFU 
EJ1G-TC4, EJ1G-TC2, EJ1G-HFU 
G3ZA (only when connected to EJ1N-TC4, EJ1N-TC2, EJ1G-TC4, EJ1G-TC2) 
G3PW (only when connected to EJ1N-TC4, EJ1N-TC2) 
Note: Models with DeviceNet communications are not supported.
Personal 
computer 
system 
requirements
OSOS: Microsoft Windows XP (Service Pack 3 or higher), Vista, 7 or 8 
CPU: A processor recommended by Microsoft 
Memory: A memory recommended by Microsoft
CPU300 MHz min.
Memory128 MB min.
Harddisk300 MB min. available space
CD-ROMOne CD-ROM drive min.
MonitorXGA (1024 × 768), High Color 16 bit min.
Communications 
ports
RS-232C port, or USB port, 1 port min.
Connection methodAn E58-CIFQ1 USB-Serial Conversion Cable is required to connect a computer 
to the setup tool port the E5[]N, E5[]N-H, E5[]N-HT, or EJ1. 
An E58-CIFQ2 USB-Serial Conversion Cable is required to connect a computer 
to the setup tool port the E5CC, E5EC, E5AC, E5DC, E5CC-T, E5EC-T, or 
E5AC-T 
A K3SC Interface Converter is used to connect a computer to models with RS- 
422/RS-485 communications. 
An E58-CIFIR USB-Infrared Conversion Cable is required to wirelessly connect a 
computer to models with infrared communications (E5EN-H/EN-HT or E5AN-H/ 
AN-HT).
 

View Complete Details

Yes, I am interested!

ThermoTools Support Software ESTT
Interested in this product?
Get Best Quote
Specifications: 

Basic functionsOfflineCreating, changing, and saving parameters
(Some parameters must be set on the Temperature Controller. Use the switches and keys on the Temperature Controller to set those parameters.)
OnlineUploading and downloading parameters. Editing parameters during operation, data log viewer, and simple data logging.
Compatible modelsTemperature ControllersE5[]R, E5[]K, E5ZN, and E5ZE Series (models with communications)
Digital Panel MetersK3N[]and K3GN Series (models with communications)
Personal computer system requirementsCPUPentium, 133 MHz or higher
OSWindows 2000
Memory64 MB min.
Hard disk650 MB min. available space
CD-ROMOne CD-ROM drive
Communications portsRS-232C ports COM1 to COM4 (A USB port can be used if the OMRON K3SC Communications Adapter is used.)
MonitorSVGA (800 × 600). Recommended: XGA (1024 × 768), high color (16 bits) min.
 

View Complete Details

Yes, I am interested!

Temperature Sensor E52-THE5A / 6D / 6F
Interested in this product?
Get Best Quote
Specifications: 

Temperature Ranges

 

Temperature rangeColor 
code
Nominal 
resistance
Thermistor
constant
Lead wire
-50°C to 50°CBlue6 kΩ (0°C)3390KA pair of 0.12 dia. 7 Fluororesin-insulated stranded wires
with 0.86 outer dia. each
0°C to 100°CBlack6 kΩ (0°C)3390K
50°C to 150°CRed30 kΩ (0°C)3450K
100°C to 200°CYellow0.55 kΩ (200°C)4300K
150°C to 300°CGreen4 kΩ (200°C)5133KFlat glass-wool-shielded lead cable with 0.12 dia. 10 
conductors and external dimensions of 2.5 × 1.55

 

Specifications

 

ItemE52-THE[][]
Coupling methodElement interchangeable thermistor
ClassJIS class 1
Protective tubing materialSUS304
Time constant8 to 15 s in still water
Dissipation factor2.4 to 2.8 mW/°C in still air
Lead wire heat resistive temperature180°C
 

View Complete Details

Yes, I am interested!

Infrared Thermosensor ES1B
Interested in this product?
Get Best Quote
Specifications: 

ItemES1B
Power supply voltage12/24 VDC
Operating voltage range90% to 110% of the power supply voltage
Current consumption20 mA max.
Measuring temperature range10 to 70°C, 60 to 120°C, 115 to 165°C, 140 to 260°C
Accuracy 
*1
±5°C *2±2% PV or ±2°C, whichever is larger
±10°C *2±4% PV or ±4°C, whichever is larger
±30°C *2±6% PV or ±6°C, whichever is larger
±40°C *2±8% PV or ±8°C, whichever is larger
Reproducibility±1% PV or ±1°C, whichever is larger
Temperature drift0.4°C/°C max.
Sensing distance vs. sensing diameter1:1 typ.
Measurement wavelength6.5 to 14.0 μm
Receiver elementThermopile
Response speedApproximately 300 ms at response rate of 63%
Output impedance1 to 4 kΩ
Operating temperature-25°C to 70°C (with no icing or condensation)
Allowable ambient humidity35% to 85%
Vibration resistance (destruction)98 m/s2 for 2 hours each in X, Y, and Z directions at 10 to 55 Hz
Shock resistance (destruction)300 m/s2 for 3 times each in X, Y, and Z directions
Casing materialABS resin
Degree of protectionIP65
Applicable safety standardsCE Marking
WeightApprox. 120 g
CableCompensating conductor: 3 m
PVC-covered cable with a shield wire resisting 70°C
 

View Complete Details

Yes, I am interested!

Infrared Thermo Sensors ES1C
Interested in this product?
Get Best Quote
Specifications: 
ModelES1C
Power supply voltage12 to 24 VDC
Operating voltage range90% to 110% of rated voltage
Current consumption70 mA max.
Measuring temperature range0 to 400°C
Measurement accuracy0 to 200°C: ±2°C, 201 to 400°C: ±1% PV (emissivity: 0.95)
Response time100 ms/90%
Reproducibility±1% of reading value
Measurement wavelength8 to 14 μm
Light-receiving elementThermopile
Emissivity0.95 fixed
Current output4 to 20 mA DC, Load: 250 Ω max.
Ambient temperature rangeOperating: 0 to 70°C, Storage: -20 to 70°C (with no icing or condensation)
Ambient humidity rangeOperating and storage: 35% to 85%
Vibration resistance (destruction)1.5-mm amplitude at 10 to 55 Hz for 2 hours each in the X, Y, and Z directions
Weight180 g
Degree of protectionEquivalent to IP67
Applicable safety standardsCE Marking

View Complete Details

Yes, I am interested!