K-System Signal Conditioners

K-System signal conditioners are optimized for applications, where signals occur from hazardous areas and safe areas. The modules are equipped with all system features of the K-System isolated barriers. This includes the power supply and collective error message via Power Rail.

Switch Amplifiers
Interested in this product?
Get Best Quote

Switch Amplifiers

Get Latest Price

Switch Amplifier
KCD2-SOT-1.LB
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508
Switch Amplifier
KCD2-SOT-1.LB.SP
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508
Switch Amplifier
KCD2-SOT-2
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508
Switch Amplifier
KCD2-SOT-2.SP
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508
Switch Amplifier
KCD2-SR-1.LB
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508
Switch Amplifier
KCD2-SR-1.LB.SP
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508
Switch Amplifier
KCD2-SR-2
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508

View Complete Details

Yes, I am interested!

Relay Modules
Interested in this product?
Get Best Quote

Relay Modules

Get Latest Price

Relay Module
KFD0-RO-2
2-channel signal conditioner, 24 V DC supply (loop powered), Relay contact output, Logic input 15 V DC ... 30 V DC, non-polarized, Up to SIL3 acc. to IEC 61508
Relay Module
KFD0-RSH-1
1-channel signal conditioner, 24 V DC supply (loop powered), Fail-safe relay contact output, Logic input 16 V DC ... 30 V DC, non-polarized, Up to SIL3 acc. to IEC 61508
Relay Module
KFD0-RSH-1-Y2
1-channel signal conditioner, 24 V DC supply (loop powered), Fail-safe relay contact output, Logic input 20 V DC ... 30 V DC, non-polarized, Test pulse immunity, Up to SIL3 acc. to IEC 61508
Relay Module
KFD0-RSH-1.4S.PS2
1-channel signal conditioner, 24 V DC supply (loop powered), Fail-safe relay contact output for de-energized and energized to safe function , Logic input 20 V DC ... 26.5 V DC, non-polarized, Test pulse immunity, Up to SIL3 acc. to IEC 61508

View Complete Details

Yes, I am interested!

Transmitter Power Supplies
Interested in this product?
Get Best Quote
SMART Transmitter Power Supply
KCD2-STC-1
1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Housing width 12.5 mm, Up to SIL2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 19 ... 30 V DC, SIL/IEC 61508
SMART Transmitter Power Supply
KCD2-STC-1.SP
1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Housing width 12.5 mm, Connection via spring terminals, Up to SIL2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 19 ... 30 V DC, SIL/IEC 61508
Transmitter Power Supply
KFD2-CR4-1
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, Accuracy 0.1 %, Up to SIL2 acc. to IEC 61508, Input: 3-wire transmitter, Rated voltage: 20 ... 35 V DC, SIL/IEC 61508
Transmitter Power Supply
KFD2-CR4-1.2O
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, Accuracy 0.1 %, Up to SIL3 acc. to IEC 61508, Input: 3-wire transmitter, Rated voltage: 20 ... 32 V DC, SIL/IEC 61508

View Complete Details

Yes, I am interested!

SC-System
Interested in this product?
Get Best Quote

SC-System

Get Latest Price

SC-System signal conditioners are suitable for applications where only safe area signals occur. The SC-System offers galvanic isolation in very compact design optimized for requirements of the safe area.

View Complete Details

Yes, I am interested!

Solenoid Drivers

Get Latest Price

Solenoid Driver, Power Amplifier
KFD2-SL-4
4-channel signal conditioner, 24 V DC supply (Power Rail), Output 600 mA per channel, Logic inputs, Common safety-oriented disable input, Line fault detection (LFD), Up to SIL2 acc. to IEC 61508

View Complete Details

Yes, I am interested!

Frequency Converters

Get Latest Price

Over speed/Under speed Monitor
KFD2-DWB-1.D
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 12 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL2 acc. to IEC 61508/IEC 61511, Function (P2P): Limit value, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact, SIL/IEC 61508
Standstill and Rotational Direction Monitor
KFD2-SR2-2.W.SM
2-channel signal conditioner, 24 V DC supply, PNP/push-pull, dry contacts or NAMUR inputs, Selectable frequency trip values, 2 relay contact outputs, Start-up override, Selectable mode of operation, Up to SIL2 acc. to IEC 61508, Function (P2P): Limit value+rotation direction/slip, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact, SIL/IEC 61508
Frequency Converter with Trip Values
KFD2-UFC-1.D
1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input frequency 1 mHz ... 12 kHz, Current output 0/4 mA ... 20 mA, Relay and transistor output, Start-up override, Line fault detection (LFD), Up to SIL2 acc. to IEC 61508/IEC 61511, Function (P2P): Frequency current converter + trip value, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508

View Complete Details

Yes, I am interested!

Trip Amplifiers

Trip Amplifiers

Get Latest Price

Ask for Details
Tell us what you need, and we’ll help you get quotes
Tell us what you
need
Receive seller
details
Seal the deal
Pay with IndiaMART
Tell us what you need, and we’ll help you get quotes
I agree to the terms and privacy policy