Pepperl & Fuchs Switch Amplifier

Producers of a wide range of products which include Pepperl & Fuchs KCD2-SR-Ex1.LB Switch Amplifier, Pepperl & Fuchs KCD2-SR-Ex2 Switch Amplifier, Pepperl & Fuchs KFD2-SR2-Ex1.W.LB Switch Amplifier, pepperl & Fuchs KFD2-SR2-Ex2.W Switch Amplifier, Pepperl & Fuchs KFD2-SOT3-Ex1.LB Switch Amplifier and Pepperl & Fuchs KFD2-SR2-Ex1.W Switch Amplifier.

Pepperl & Fuchs KCD2-SR-Ex1.LB  Switch Amplifier
  • Pepperl & Fuchs KCD2-SR-Ex1.LB  Switch Amplifier
  • Pepperl & Fuchs KCD2-SR-Ex1.LB  Switch Amplifier
Interested in this product?
Get Best Quote
Power45 mW (linear characteristic)
BrandPepperl & Fuchs
Safety Integrity LevelSIL 2
ConnectionPower Rail or terminals 9+, 10-
Rated voltage19 ... 30 V DC
Rippleless than equal 10 %
Rated currentless than equal 30 mA
Power consumptionless than equal 500 mW
Connection sidefield side
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage short circuit currentapprox. 10 V DC / approx. 8 mA
Switching point switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line Fault Detectionbreakage I less than equal 0.1 mA , short-circuit I greater than equal 6.5 mA
Pulse Pause Ratiomin. 20 ms / min. 20 ms
Output Connection sidecontrol side
Output Connectionoutput I: terminals 5, 6 ; output II: terminals 7, 8
Output Isignal ; relay
Output IIsignal or error message ; relay
Contact Loading253 V AC/2 A/cos greater tha 0.7; 126.5 V AC/4 A/cos greater than 0.7; 30 V DC/2 A resistive load
Minimum switch current2 mA / 24 V DC
Energized De Energized Delayless than equal 20 ms / greater than equal 20 ms
Mechanical Life107 switching cycles
Switching FrequencyGreater than equal 10 Hz
Input power supplyreinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
Output power supplyreinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
Display ElementsLEDs
Control ElementsDIP-switch
Configurationvia DIP switches
Labelingspace for labeling at the front
DirectiveEN 61326-1:2013 (industrial locations) 2014/30/EU
Low voltage DirectiveEN 61010-1:2010 (2014/35/EU)
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529:2001
Ambient Temperature-20 ... 60 degree C (-4 ... 140 degree F)
Massapprox. 100 g
Dimensions12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU Type Examination CertificateBASEEFA 06 ATEX 0092
Input[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Voltage10.5 V
Current17.1 mA
Maximum safe voltage253 V AC (Attention! Um is no rated voltage.)
Output I II Maximum safe voltage253 V AC (Attention! Um is no rated voltage.)
CertificatePF 06 CERT 0972 X
MarkingII 3G Ex nA nC IIC T4 Gc
Galvanic isolation Input power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformityEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010(2014/34/EU)
Control Drawing116-0419 (cFMus)
IECEx ApprovalIECEx BAS 06.0025
Approved for[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Supplementary InformationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applica
UL Approval Control drawing116-0420 (cULus)
FM Approval Control drawing116-0419 (cFMus)

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc.toIEC61508 This isolated barrier is used for intrinsic safety applications. It transfers
digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area.The proximity sensor or switch controls
a form A normally open relay contact for the safe area load.
The normal output state can be reversed using switch S1. Switch S2 allows output II to be switched between a signal output and an error message output. Switch S3 enablesdisables line faultdetection of the field circuit.During an error condition, relays revert to their de-energized state and LEDs indicate the fault according to NAMUR NE44
A unique collective error messaging feature is available when used with the Power Rail system.Due to its compact housing design and low heat dissipation, this device is useful for detecting positions, end stops, and switching states in space critical applications.

Features

  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Usable as a ignal splitter (1 input and 2 outputs)
  • Relay contact output
  • Fault relay contact output
  • Line fault detection (LFD)
  • Housing width 12.5 mm
  • Up to SIL 2 acc.toIEC61508


View Complete Details

Yes, I am interested!

Pepperl & Fuchs  KCD2-SR-Ex2 Switch Amplifier
  • Pepperl & Fuchs  KCD2-SR-Ex2 Switch Amplifier
  • Pepperl & Fuchs  KCD2-SR-Ex2 Switch Amplifier
Interested in this product?
Get Best Quote
Signal TypeDigital Input
Safety Integrity LevelSIL 2
ConnectionPower Rail or terminals 9+, 10-
Rated voltage19 ... 30 V DC
Rippleless than equal 10 %
Rated currentless than equal 30 mA
Power Dissipationless than equal 600 mW
Power consumptionless than equal 600 mW
Connection sidefield side
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage short circuit currentapprox. 10 V DC / approx. 8 mA
Switching point switching Hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line Fault Detectionbreakage I less than equal 0.1 mA , short-circuit I greater than equal 6.5 mA
Pulse Pause Ratiomin. 20 ms / min. 20 ms
Output Connection sidecontrol side
Output Connectionterminals 5, 6; 7, 8
Output IIsignal ; relay
Contact Loading253 V AC/2 A/cos less 0.7; 126.5 V AC/4 A/cos greater than equal 0.7; 30 V DC/2 A resistive load
Minimum switch current2 mA / 24 V DC
Energized De Energized Delayless than equal 20 ms / less than equal 20 ms
Mechanical Life107 switching cycles
Switching FrequencyGreater than equal 10 Hz
InputBasic insulation according to EN 50178, rated insulation voltage 300 Veff
Display ElementsLEDs
Control ElementsDIP-switch
Configurationvia DIP switches
Labelingspace for labeling at the front
DirectiveEN 61326-1:2013 (industrial locations ( 2014/30/EU)
Low voltage DirectiveEN 61010-1:2010 (2014/35/EU)
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529:2001
Ambient Temperature-20 ... 60 degree C (-4 ... 140 degreeF)
Mechanical Degree of protectionIP20
Mechanical Connectionscrew terminals
Massapprox. 100 g
Dimensions12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU Type Examination CertificateBASEEFA 06 ATEX 0092
CertificatePF 06 CERT 0972 X
MarkingEx-Hexagon II 3G Ex nA nC IIC T4 Gc
Output I II Contact Loading50 V AC/2 A/cos greater than 0.7; 30 V DC/2 A resistive load
FM Approval Control Drawing116-0419 (cFMus)
UL A pproval Control Drawing116-0420 (cULus)
IECEx A pproval Approved For[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
BrandPepperl & Fuchs
power45 mW
Current17.1 mA
Voltage10.5 V

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc.toIEC61508, This isolated barrier is used for intrinsic safety applications. It transfers
digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area. The proximity sensor or switch controls
a form A normally open relay contact for the safe area load.
The normal output state can be reversed using switch S1. Switch S2 allows output II to be switched between a signal output and an error message output. Switch S3 enablesdisables line faultdetection of the field circuit.D uring an error condition, relays revert to their de-energized state and LEDs indicate the fault according to NAMUR NE44
to its compact housing design and low heat dissipation, this device is useful for detecting positions, end stops, and switching states in space critical applications.

Features

  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Line fault detection (LFD)
  • Housing width 12.5 mm
  • Up to SIL 2 acc.toIEC61508


View Complete Details

Yes, I am interested!

Pepperl & Fuchs KFD2-SR2-Ex1.W.LB Switch Amplifier
  • Pepperl & Fuchs KFD2-SR2-Ex1.W.LB Switch Amplifier
  • Pepperl & Fuchs KFD2-SR2-Ex1.W.LB Switch Amplifier
Interested in this product?
Get Best Quote
Signal TypeDigital Input
Safety Integrity LevelSIL 2
ConnectionPower Rail or terminals 14+, 15-
Rated voltage20 ... 30 V DC
Rippleless than equal 10 %
Rated currentless than equal 50 mA
Power Dissipation1 W
Power consumptionless than 1.3 W
Connection sidefield side
Input Connectionterminals 1+, 2+, 3-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage short circuit currentapprox. 8 V DC / approx. 8 mA
Switching point switching Hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line Fault Detectionbreakage I less than equal 0.1 mA , short-circuit I greater than 6 mA
Pulse Pause Ratiomin. 20 ms / min. 20 ms
Output Connection sidecontrol side
Output Connectionoutput I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
Output Isignal ; relay
Output IIsignal or error message ; relay
Minimum switch current2 mA / 24 V DC
Energized De Energized Delayapprox. 20 ms / approx. 20 ms
Mechanical Life107 switching cycles
Input Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Display ElementsLEDs
Control ElementsDIP-switch
Configurationvia DIP switches
Labelingspace for labeling at the front
DirectiveEN 61326-1:2013 (industrial locations)(2014/30/EU)
Low voltage DirectiveEN 61010-1:2010 (2014/35/EU)
Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC 60529:2001
InputEN 60947-5-6:2000
Ambient Temperature-20 ... 60 degre C (-4 ... 140 degreeF)
Mechanical Degree of protectionIP20
Mechanical Connectionscrew terminals
Massapprox. 150 g
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU Type Examination CertificatePTB 00 ATEX 2080
MarkingI (1)G [Ex ia Ga] IIC Ex-Hexagon II (1)D [Ex ia Da] IIIC Ex-Hexagon I (M1) [Ex ia Ma] I
Power34 mW (linear characteristic)
Maximum safe voltage253 V AC / 125 V DC (Attention! Um is no rated voltage.)
Output Contact Loading253 V AC/2 A/cos less than 0.7; 126.5 V AC/4 A/cos less than 0.7; 40 V DC/2 A resistive load
Output Maximum safe voltage253 V AC (Attention! The rated voltage can be lower.)
Fault Indication output Maximum safe voltage40 V DC (Attention! Um is no rated voltage.)
CertificatePF 08 CERT 0803
Fault Idication output MarkingII (3)G [Ex ic Gc] IIC
Contact Loading253 V AC/2 A/cos greater th 0.7; 126.5 V AC/4 A/cos greater than 0.7; 40 V DC/2 A resistive load
Galvanic isolation Input Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Galvanic Isolation Input power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformityEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 (2014/34/EU)
FM Approval Control Drawing116-0035
CSA Approval Control Drawing116-0047
IECEx ApprovalIECEx PTB 11.0034
Approved For[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Supplementary InformationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applica
Voltage10.5 V
Current13 mA
Switching Frequencyless than equal 10 Hz
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation,This isolated barrier is used for intrinsic safety applications. It transfers
digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area.The proximity sensor or switch controls
a form A normally open relay contact for the safe area load.
The normal output state can be reversed using switch S1. Switch S2 allows output II to be switched between a signal output and an error message output. Switch S3 enables-disables line fault detection of the field circuit.During an error condition, relays revert to their de-energized state and LEDs indicate the fault according to NAMUR NE44
A unique collective error messaging feature is available when used with the Power Rail system.

Features

  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Usable as the signal splitter (1 input and 2 outputs)
  • Relay contact output
  • Fault relay contact output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc.toIEC61508/IEC61511

View Complete Details

Yes, I am interested!

pepperl  & Fuchs  KFD2-SR2-Ex2.W Switch Amplifier
  • pepperl  & Fuchs  KFD2-SR2-Ex2.W Switch Amplifier
  • pepperl  & Fuchs  KFD2-SR2-Ex2.W Switch Amplifier
Interested in this product?
Get Best Quote
Power34 mW (linear characteristic)
Signal TypeDigital Input
Input Connectionterminals 1+, 2+, 3-; 4+, 5+, 6-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage short circuit currentapprox. 8 V DC / approx. 8 mA
Switching point switching Hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line Fault Detectionbreakage I lesss than equal 0.1 mA , short-circuit I greater than 6 mA
Pulse Pause Ratiomin. 20 ms / min. 20 ms
Output Connection sidecontrol side
Output Connectionoutput I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
Output I IIsignal, relay
Contact Loading253 V AC/2 A/cos less than 0.7; 126.5 V AC/4 A/cos greater than 0.7; 40 V DC/2 A resistive load
Safety Integrity LevelSIL 2
Minimum switch current2 mA / 24 V DC
Energized De Energized Delayapprox. 20 ms / approx. 20 ms
Mechanical life107 switching cycles
Switching Frequencyless than equal 10 Hz
Galvanic Isolation Input Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Display ElementsLEDs
Control ElementsDIP-switch
ConnectionPower Rail or terminals 14+, 15-
Configurationvia DIP switches
Labelingspace for labeling at the front
DirectiveEN 61326-1:2013 (industrial locations) 2014/30/EU
Low voltage DirectiveEN 61010-1:2010 (2014/35/EU)
Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC 60529:2001
Conformity InputEN 60947-5-6:2000
Ambient Temperature-20 ... 60 degree C (-4 ... 140 degree F)
Mechanical Degree of protectionIP20
Mechanical Connectionscrew terminals
Rated voltage20 ... 30 V DC
Massapprox. 150 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU Type Examination CertificatePTB 00 ATEX 2080
Marking(1)G [Ex ia Ga] IIC Ex-Hexagon II (1)D [Ex ia Da] IIIC Ex-Hexagon I (M1) [Ex ia Ma] I
Voltage10.5 V
Current13 mA
Maximum safe voltage253 V AC / 125 V DC (Attention! Um is no rated voltage.)
Output Contact Loading253 V AC/2 A/cos greater th 0.7; 126.5 V AC/4 A/cos greater than 0.7; 40 V DC/2 A resistive load
Rippleless than equal 10 %
Output Maximum safe voltage253 V AC (Attention! The rated voltage can be lower.)
Fault Indication output Maximum safe voltage40 V DC (Attention! Um is no rated voltage.)
CertificatePF 08 CERT 0803
Fault Indication output CertificatePF 08 CERT 0803
Fault Indication output MarkingII (3)G [Ex ic Gc] IIC
InputEx ic
Galvanic Isolation Input power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformityEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 (2014/34/EU)
FM Approval Control Drawing116-0035
CSA Approval Control Drawing116-0047
Rated currentless than equal 50 mA
IECEx ApprovalIECEx PTB 11.0034
Approved for[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Supplementary InformationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applica
Power Dissipation1 W
Power consumptionless than 1.3 W
Connection sidefield side

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, This isolated barrier is used for intrinsic safety applications. It
transfers digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area.The proximity sensor or switch
controls a form C changeover relay contact for the safe area load. The normal output state can be reversed using switches
S1 and S2. Switch S3 is used to enable or disable line fault
detection of the field circuit.During an error condition, the relays revert to their de-energized state and the LEDs indicate the fault according to dicate the fault according to A unique collective error messaging feature is available when used with the Power Rail system.


Features
  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc.toIEC61508

View Complete Details

Yes, I am interested!

Pepperl & Fuchs KFD2-SOT3-Ex1.LB Switch Amplifier
  • Pepperl & Fuchs KFD2-SOT3-Ex1.LB Switch Amplifier
  • Pepperl & Fuchs KFD2-SOT3-Ex1.LB Switch Amplifier
Interested in this product?
Get Best Quote
Brandpepperl & Fuchs
Signal TypeDigital Input
Output Rated current100 mA , short-circuit protected
Response Timeless than equal 200
Safety Integrity LevelSIL 2
Signal Level1-signal: (external voltage) - 3 V max. for 100 mA 0-signal: blocked output (off-state current l 10
Output Isignal ; Transistor
Output IIsignal or error message ; Transistor
Switching Frequencyless than equal 5 kHz
Display ElementsLEDs
Control ElementsDIP-switch
Rated valuesacc. to EN 60947-5-6 (NAMUR), see system description for electrical data
Configurationvia DIP switches
Labelingspace for labeling at the front
DirectiveEN 61326-1:2013 (industrial locations)( 2014/30/EU)
ConnectionPower Rail or terminals 14+, 15-
Electromagnetic compatibilityNE 21:2012 , EN 61326-3-2:2008
Degree of protectionIEC 60529:2001
Ambient Temperature-20 ... 60 degreeC (-4 ... 140 degree F)
Mechanical Degree of protectionIP20
Mechanical Connectionscrew terminals
Massapprox. 150 g
Open circuit voltage short circuit currentapprox. 10 V DC / approx. 8 mA
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU Type Examination CertificateEXA 16 ATEX 0016 X
MarkingII 3(1)G Ex nA [ia Ga] IIC T4 Gc Ex-Hexagon II (1)D [Ex ia Da] IIIC Ex-Hexagon I (M1) [Ex ia Ma] I
Rated voltage19 ... 30 V DC
Directive conformityEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010(2014/34/EU)
IECEx ApprovalIECEx EXA 16.0009X
Approved ForEx nA [ia Ga] IIC T4 Gc , [Ex ia Da] IIIC , [Ex ia Ma] I
Optional Accessoriespower feed module KFD2-EB2 Universal Power Rail UPR-03 Universal Power Rail UPR-03-S profile rail K-
Rippleless than equal 10 %
Switching point switching Hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Rated current20 ... 15 mA
Power Dissipationless than equal 1 W including maximum power dissipation in the output
Input Connection sidefield side
Input Connectionterminals 1+, 2+, 3-
Line Fault Detectionbreakage I less than equal 0.1 mA , short-circuit I greater than equal6.5 mA
Pulse Pause Ratiomin. 100 / min. 100
Output Connection sidecontrol side
Output Connectionoutput I: terminals 7, 8 ; output II: terminals 8, 9
Output Rated voltage30 V DC

channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc.toIEC61508 This isolated barrier is used for intrinsic safety applications. It transfers
digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area. The input controls two passive transistor outputs.Via switches the mode of operation can be reversed and the line fault detection can be switched off.Via switches the function of the second output can be defined as a signal output or a fault indication output.A fault is signalized by LEDs acc. to NAMUR NE44 and a separate collective error message output.

Features
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Passive transistor output, non-polarized
  • Passive fault output, non-polarized
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc.toIEC61508

View Complete Details

Yes, I am interested!

Pepperl & Fuchs KFD2-SR2-Ex1.W Switch Amplifier
  • Pepperl & Fuchs KFD2-SR2-Ex1.W Switch Amplifier
  • Pepperl & Fuchs KFD2-SR2-Ex1.W Switch Amplifier
Interested in this product?
Get Best Quote
Power34 mW (linear characteristic)
Signal TypeDigital Input
Input Connectionterminals 1+, 2+, 3-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage short circuit currentapprox. 8 V DC / approx. 8 mA
Switching point switching Hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line Fault Detectionbreakage I less than equal 0.1 mA , short-circuit I greater than 6 mA
Pulse Pause Ratiomin. 20 ms / min. 20 ms
Output Connection sidecontrol side
Output Connectionterminals 7, 8, 9
Output Contact loading253 V AC/2 A/cos greater th 0.7; 126.5 V AC/4 A/cos greater than 0.7; 40 V DC/2 A resistive load
Outputsignal ; relay
Safety Integrity LevelSIL 2
Minimum switch current2 mA / 24 V DC
Energize De Energized Delayapprox. 20 ms / approx. 20 ms
Mechanical Life107 switching cycles
Switching Frequencyless than 10 Hz
Galvanic Isolation Input Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Galvanic Isolation Input power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Galvanic Isolation Output power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Display ElementsLEDs
Control ElementsDIP-switch
Low voltage DirectiveEN 61010-1:2010 (2014/35/EU)
ConnectionPower Rail or terminals 14+, 15-
Conformity InputEN 60947-5-6:2000
Voltage10.5 V
Current13 mA
Maximum safe voltage253 V AC / 125 V DC (Attention! Um is no rated voltage.)
Fault Indication output Maximum safe voltage40 V DC (Attention! Um is no rated voltage.)
CertificatePF 08 CERT 0803
InputEx ic
Input power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformityEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 (2014/34/EU)
FM Approval Control Drawing116-0035
Rated voltage20 ... 30 V DC
CSA Approval Control Drawing116-0047
IECEx ApprovalIECEx PTB 11.0034
Approved For[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Supplementary InformationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applica
Configurationvia DIP switches
Labelingspace for labeling at the front
DirectiveEN 61326-1:2013 (industrial locations) 2014/30/EU
Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC 60529:2001
Ambient Temperature-20 ... 60 degreeC (-4 ... 140 degreeF)
Rippleless than equal 10 %
Mechanical Degree of protectionIP20
Mechanical Connectionscrew terminals
Massapprox. 150 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU Type Examination CertificatePTB 00 ATEX 2080
MarkingI (1)G [Ex ia Ga] IIC Ex-Hexagon II (1)D [Ex ia Da] IIIC Ex-Hexagon I (M1) [Ex ia Ma] I
Rated currentless than equal 30 mA
Power Dissipation0.7 W
Power consumptionless than 0.9 W
Input Connection sidefield side

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation,This isolated barrier is used for intrinsic safety applications. It
transfers digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area.The The proximity sensor or switch
controls a form C changeover relay contact for the safe area load. The barrier output changes state when the input signal changes state. normal output state can be reversed using switch S1. Switch S3 is used to enable or disable line fault detection of the field circuit.During an error condition, the relay reverts to its de-energized state and the LEDs indicate the fault according to NAMUR NE44.A unique collective error messaging feature is available when used with the Power Rail system.

Features
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc.toIEC61508/IEC61511

View Complete Details

Yes, I am interested!

Pepperl & Fuchs  KFA5-SR2-Ex1.W Switch Amplifier
  • Pepperl & Fuchs  KFA5-SR2-Ex1.W Switch Amplifier
  • Pepperl & Fuchs  KFA5-SR2-Ex1.W Switch Amplifier
Interested in this product?
Get Best Quote
Power51 mW (linear characteristic)
Brandpepperl & Fuchs
Signal TypeDigital Input
Switching point switching Hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line Fault Detectionbreakage I less than equal 0.1 mA , short-circuit I greater than 6 mA
Pulse Pause Ratiomin. 20 ms / min. 20 ms
Output Connection sidecontrol side
Output Connectionterminals 7, 8, 9
Outputsignal, relay
Contact Loading253 V AC/2 A/cos greater th 0.7; 126.5 V AC/4 A/cos greater than 0.7; 40 V DC/2 A resistive load
Energized De Energized Delayapprox. 20 ms / approx. 20 ms
Mechanical Life107 switching cycles
Switching Frequencyless than 10 Hz
Safety Integrity LevelSIL 2
Galvanic Isolation Input Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Galvanic Isolation Input power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Galvanic Isolation Output power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Display ElementsLEDs
Control ElementsDIP-switch
Configurationvia DIP switches
Labelingspace for labeling at the front
Electromagnetic compatibility DirectiveEN 61326-1:2013 (industrial locations)( 2014/30/EU)
Low voltage DirectiveEN 61010-1:2010 (2014/35/EU)
Electromagnetic compatibilityNE 21:2006
Connectionterminals 14, 15
Degree of protectionIEC 60529:2001
InputEN 60947-5-6:2000
Ambient Temperature-20 ... 60 degreeC (-4 ... 140 degreeF)
Mechanical Degree of protectionIP20
Mechanical Connectionscrew terminals
Massapprox. 150 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU Type Examination CertificatePTB 00 ATEX 2081
MarkingII (1)G [Ex ia Ga] IIC Ex-Hexagon II (1)D [Ex ia Da] IIIC Ex-Hexagon I (M1) [Ex ia Ma] I Input
Rated voltage103.5 ... 126 V AC , 45 ... 65 Hz
Voltage10.6 V
Current19.1 mA
Supply Maximum safe voltage126.5 V AC (Attention! Um is no rated voltage.)
Output Contact loading253 V AC/2 A/cos greater th 0.7; 126.5 V AC/4 A/cos greater than 0.7; 40 V DC/2 A resistive load
Output Maximum safe voltage253 V AC (Attention! The rated voltage can be lower.)
Input power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
DirectiveEN 60079-0:2012+A11:2013 , EN 60079-11:2012 (2014/34/EU)
FM Approval Control Drawing116-0035
UL Approval Control Drawing116-0145
Power consumption1 W
CSA Approval Control Drawing116-0047
IECEx ApprovalIECEx PTB 11.0031
Approved for[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Supplementary InformationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applica
Input Connection sidefield side
Input Connectionterminals 1+, 2+, 3-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage short circuit currentapprox. 8 V DC / approx. 8 mA

-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc.This isolated barrier is used for intrinsic safety applications. It
transfers digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area.The The proximity sensor or switch
controls a form C changeover relay contact for the safe area load. The barrier output changes state when the input signal changes state. normal output state can be reversed using switch S1. Switch S3 is used to enable or disable line fault detection of the field circuit.During an error condition, the relay reverts to its de-energized state and the LEDs indicate the fault according to NAMUR NE44.A unique

Features
  • 1-channel isolated barrier
  • 115 V AC supply
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc.toIEC61508/IEC61511

View Complete Details

Yes, I am interested!

pepperl & Fuchs KFA6-SR2-Ex1.W Switch Amplifier
  • pepperl & Fuchs KFA6-SR2-Ex1.W Switch Amplifier
  • pepperl & Fuchs KFA6-SR2-Ex1.W Switch Amplifier
Interested in this product?
Get Best Quote
Power51 mW (linear characteristic)
Brandpepperl & Fuchs
Signal TypeDigital Input
Open circuit voltage short circuit currentapprox. 8 V DC / approx. 8 mA
Switching point switching Hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line Fault Detectionbreakage I less than equal 0.1 mA , short-circuit I greater than 6 mA
Pulse Pause Ratiomin. 20 ms / min. 20 ms
Output Connectionterminals 7, 8, 9
Output Connection sideConnection side
Outputsignal ; relay
Output Contact Loading253 V AC/2 A/cos greater th 0.7; 126.5 V AC/4 A/cos greater than 0.7; 40 V DC/2 A resistive load
Energized De Energized Delayapprox. 20 ms / approx. 20 ms
Mechanical Life107 switching cycles
Safety Integrity LevelSIL 2
Switching Frequencyless than 10 Hz
Galvanic isolation Input Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Display ElementsLEDs
Labelingspace for labeling at the front
Electromagnetic compatibility DirectiveEN 61326-1:2013 (industrial locations)(2014/30/EU)
Low voltage DirectiveEN 61010-1:2010 (2014/35/EU)
Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC 60529:2001
Connectionterminals 14, 15
InputEN 60947-5-6:2000
Ambient Temperature-20 ... 60 degreeC (-4 ... 140 degree F)
Mechanical Degree of protectionIP20
Mechanical Connectionscrew terminals
Massapprox. 150 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU Type Examination CertificatePTB 00 ATEX 2081
MarkingII (1)G [Ex ia Ga] IIC Ex-Hexagon II (1)D [Ex ia Da] IIIC Ex-Hexagon I (M1) [Ex ia Ma] I
Voltage10.6 V
Rated voltage207 ... 253 V AC, 45 ... 65 Hz
Current19.1 mA
Supply Maximum safe voltage253 V AC (Attention! Um is no rated voltage.)
Output Maximum safe voltage253 V AC (Attention! The rated voltage can be lower.)
Galvanic Isolation Input power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
DirectiveEN 60079-0:2012+A11:2013 , EN 60079-11:2012(2014/34/EU)
FM Approval Control Drawing116-0035
UL Approval Control Drawing116-0145
CSA Approval Control Drawing116-0047
IECEx ApprovalIECEx PTB 11.0031
Power Dissipation1 W
Approved for[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Supplementary InformationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applica
Power consumptionmax. 1 W
Input Connectionterminals 1+, 2+, 3-
Input Connection sidefield side
Input Rated valuesacc. to EN 60947-5-6 (NAMUR)

-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. This isolated barrier is used for intrinsic safety applications. It
transfers digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area.The The proximity sensor or switch
controls a form C changeover relay contact for the safe area load. The barrier output changes state when the input signal changes state. normal output state can be reversed using switch S1. Switch S3 is used to enable or disable line fault detection of the field circuit.During an error condition, the relay reverts to its de-energized state and the LEDs indicate the fault according to NAMUR NE44.

Features
  • 1-channel isolated barrier
  • 230 V AC supply
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc.toIEC61508/IEC61511

View Complete Details

Yes, I am interested!

Pepperl & Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier
  • Pepperl & Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier
  • Pepperl & Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier
Interested in this product?
Get Best Quote
Power51 mW (linear characteristic)
Brandpepperl & Fuchs
Signal TypeDigital Input
Switching point switching Hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line Fault Detectionbreakage I less than equal 0.1 mA , short-circuit I greater than 6 mA
Pulse Pause Ratiomin. 20 ms / min. 20 ms
Output Connection sidecontrol side
control Connectionoutput I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
Output Isignal ; relay
Output IIsignal or error message ; relay
Contact Loading253 V AC/2 A/cos greater th 0.7; 126.5 V AC/4 A/cos greater than 0.7; 40 V DC/2 A resistive load
Energize De Energized Delayapprox. 20 ms / approx. 20 ms
Mechanical Life107 switching cycles
Safety Integrity LevelSIL 2
Switching Frequencyless than 10 Hz
Galvanic Isolation Input power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Galvanic isolation Input Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Galvanic Isolation Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Display ElementsLEDs
Labelingspace for labeling at the front
Electromagnetic compatibility DirectiveEN 61326-1:2013 (industrial locations)( 2014/30/EU)
Low voltage DirectiveEN 61010-1:2010 (2014/35/EU)
Degree of protectionIEC 60529:2001
Conformity InputEN 60947-5-6:2000
Connectionterminals 14, 15
Ambient Temperature-20 ... 60 degree C (-4 ... 140 degreeF)
Mechanical Degree of protectionIP20
Mechanical Connectionscrew terminals
Massapprox. 150 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU Type Examination CertificatePTB 00 ATEX 2081
MarkingII (1)G [Ex ia Ga] IIC Ex-Hexagon II (1)D [Ex ia Da] IIIC Ex-Hexagon I (M1) [Ex ia Ma] I
Voltage10.6 V
Current19.1 mA
Rated voltage207 ... 253 V AC, 45 ... 65 Hz
Supply Maximum safe voltage253 V AC (Attention! Um is no rated voltage.)
Output Contact loading253 V AC/2 A/cos greater th 0.7; 126.5 V AC/4 A/cos greater than 0.7; 40 V DC/2 A resistive load
Output Maximum safe voltage253 V AC (Attention! The rated voltage can be lower.)
Input power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
DirectiveEN 60079-0:2012+A11:2013 , EN 60079-11:2012(2014/34/EU)
FM Approval Control Drawing116-0035
UL Approval Control Drawing116-0145
CSA Approval Control Drawing116-0047
IECEx ApprovalIECEx PTB 11.0031
Power Dissipation1.2 W
Approved For[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Supplementary InformationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applica
Input Connection sidefield side
Input Connectionterminals 1+, 2+, 3-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage short circuit currentapprox. 8 V DC / approx. 8 mA

-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc.This isolated barrier is used for intrinsic safety applications. It
transfers digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area.The The proximity sensor or switch
controls a form C changeover relay contact for the safe area load. The barrier output changes state when the input signal changes state. normal output state can be reversed using switch S1. Switch S3 is used to enable or disable line fault detection of the field circuit.During an error condition, the relay reverts to its de-energized state and the LEDs indicate the fault according to NAMUR NE44.

Features
  • 1-channel isolated barrier
  • 230 V AC supply
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Fault relay contact output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc.toIEC61508/IEC61511

View Complete Details

Yes, I am interested!

pepperl & Fuchs KFA6-SR2-Ex2.W Switch Amplifier
  • pepperl & Fuchs KFA6-SR2-Ex2.W Switch Amplifier
  • pepperl & Fuchs KFA6-SR2-Ex2.W Switch Amplifier
Interested in this product?
Get Best Quote
Power51 mW (linear characteristic)
Brandpepperl & Fuchs
Signal TypeDigital Input
Open circuit voltage short circuit currentapprox. 8 V DC / approx. 8 mA
Switching point switching Hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line Fault Detectionbreakage I less than 0.1 mA , short-circuit I greater than 6 mA
Pulse Pause Ratiomin. 20 ms / min. 20 ms
Output Connection sidecontrol side
Output Connectionoutput I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
Output I IIsignal ; relay
Contact Loading253 V AC/2 A/cos greater th 0.7; 126.5 V AC/4 A/cos greater than 0.7; 40 V DC/2 A resistive load
Energized De Energized Delayapprox. 20 ms / approx. 20 ms
Mechanical Life107 switching cycles
Safety Integrity LevelSIL 2
Switching Frequencyless than 10 Hz
Galvanic Isolation Input power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Galvanic Isolation Output power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Display ElementsLEDs
Labelingspace for labeling at the front
DirectiveEN 61326-1:2013 (industrial locations) 2014/30/EU
Low voltage DirectiveEN 61010-1:2010 (2014/35/EU)
Electromagnetic compatibilityNE 21:2006
Supply Connectionterminals 14, 15
Degree of protectionIEC 60529:2001
Conformity InputEN 60947-5-6:2000
Ambient Temperature-20 ... 60 degreeC (-4 ... 140 degreeF)
Mechanical Degree of protectionIP20
Mechanical Connectionscrew terminals
Massapprox. 150 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU Type Examination CertificatePTB 00 ATEX 2081
MarkingII (1)G [Ex ia Ga] IIC Ex-Hexagon II (1)D [Ex ia Da] IIIC Ex-Hexagon I (M1) [Ex ia Ma] I
Rated voltage207 ... 253 V AC, 45 ... 65 Hz
Voltage10.6 V
Current19.1 mA
Supply Maximum safe voltage253 V AC (Attention! Um is no rated voltage.)
Output Contact Loading253 V AC/2 A/cos greater th 0.7; 126.5 V AC/4 A/cos greater than 0.7; 40 V DC/2 A resistive load
Galvanic Isolation Inputnot available
Galvanic Isolation Input Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Input power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
FM Approval Control Drawing116-0035
UL Approval Control Drawing116-0145
Power Dissipation1.2 W
CSA Approval Control Drawing116-0047
IECEx ApprovalIECEx PTB 11.0031
Approved For[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Supplementary InformationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applica
Power consumptionmax. 1.3 W
Input Connection sidefield side
Input Connectionterminals 1+, 2+, 3-; 4+, 5+, 6-
Rated valuesacc. to EN 60947-5-6 (NAMUR)

channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc.toIEC61508/IEC61511This isolated barrier is used for intrinsic safety applications. It transfers
digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area.The The proximity sensor or switch controls
a form C changeover relay contact for the safe area load. The barrier output changes state when the input signal changes state. normal output state can be reversed using switch S1. Switch S3 is used to enable or disable line fault detection of the field circuit.During an error condition, the relay reverts to its de-energized state and the LEDs indicate the fault according to NAMUR NE44.

Features
  • 2-channel isolated barrier
  • 230 V AC supply
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc.toIEC61508/IEC61511

View Complete Details

Yes, I am interested!

Pepperl & Fuchs KCD2-SON-Ex1  Switch Amplifier
  • Pepperl & Fuchs KCD2-SON-Ex1  Switch Amplifier
  • Pepperl & Fuchs KCD2-SON-Ex1  Switch Amplifier
Interested in this product?
Get Best Quote
Rated Current18 ... 14 mA
Dimensions12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2
Brandpepperl& Fuchs
Signal TypeDigital Input
Line Fault Detectionbreakage I less than 0.1 mA , short-circuit I greater than 6.5 mA
Pulse Pause Ratiomin. 100 / min. 100
Output Connectionoutput I: terminals 5, 6 ; output II: terminals 7, 8
Output Connection sidecontrol side
Rated voltagetyp. 8 V max. 20 V DC
Response Timeless than equal 200
Power Dissipationless than equal 500 mW
Switching Frequencyless than equal 5 kHz
Display ElementsLEDs
Safety Integrity LevelSIL 2
Control ElementsDIP-switch
Configurationvia DIP switches
Labelingspace for labeling at the front
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529:2001
Ambient Temperature-20 ... 60 degreeC (-4 ... 140 degreeF)
Mechanical Degree of protectionIP20
Mechanical Connectionscrew terminals
Massapprox. 100 g
ConnectionPower Rail or terminals 9+, 10-
Rippleless than equal 10 %
Input Connectionterminals 1+, 2-
Input Connection sidefield side
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage short circuit currentapprox. 10 V DC / approx. 8 mA
Switching point switching Hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU Type Examination CertificateBASEEFA 13 ATEX 0080
MarkingII (1)G [Ex ia Ga] IIC Ex-Hexagon II (1)D [Ex ia Da] IIIC Ex-Hexagon I (M1) [Ex ia Ma] I
CertificatePF 13 CERT 2760 X
DirectiveEN 61326-1:2013 (industrial locations) (2014/30/EU)
UL Approval Control Drawing116-0374 (cULus)
IECEx ApprovalIECEx BAS 13.0046
Approved For[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I

channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc.toIEC61508This isolated barrier is used for intrinsic safety applications. It transfers
digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area.The input controls two passiv
e transistor outputs with a resistive output characteristic (acc. to EN60947-5-6).The outputs have three defined states 1-Signal = 1.8 signal = 14 k and fault > 100 k This output characteristic offers line fault transparency on the signal lines.Via switches the mode of operation can be reversed and the line fault detection can be switched off. A fault is signalized by LEDs acc. to NAMUR NE44 and a separate collective error message output.

.Features
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR input
  • 2 passive transistor outputs (resistive acc. to EN60947-5-6)
  • Line fault transparency (LFT)
  • Housing width 12.5 mm
  • Up to SIL 2 acc.toIEC61508

View Complete Details

Yes, I am interested!

pepperl & Fuchs   KCD2-SON-Ex1.R1 Switch Amplifier
  • pepperl & Fuchs   KCD2-SON-Ex1.R1 Switch Amplifier
  • pepperl & Fuchs   KCD2-SON-Ex1.R1 Switch Amplifier
Interested in this product?
Get Best Quote
Brandpepperl& Fuchs
Signal TypeDigital Input
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage short circuit currentapprox. 10 V DC / approx. 8 mA
Switching point switching Hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line Fault Detectionbreakage I less than equal 0.1 mA , short-circuit I greater than equal6.5 mA
Pulse Pause Ratiomin. 100 / min. 100
Output Connection sidecontrol side
Output Connectionoutput I: terminals 5, 6 ; output II: terminals 7, 8
Output Rated voltage19 ... 30 V DC with external resistance gr 2 k, e. g. 16-channel ProSafe DI card SDV144 from Yokogaw
Response Timeless than equal 200
Safety Integrity LevelSIL 2
Switching Frequencyless than equal 5 kHz
Display ElementsLEDs
Control ElementsDIP-switch
Configurationvia DIP switches
Labelingspace for labeling at the front
Electromagnetic compatibility DirectiveEN 61326-1:2013 (industrial locations) 2014/30/EU
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529:2001
Ambient Temperature-20 ... 60 degreeC (-4 ... 140 degreeF)
Mechanical Degree of protectionIP20
ConnectionPower Rail or terminals 9+, 10-
Mechanical Connectionscrew terminals
Massapprox. 100 g
Dimensions12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU Type Examination CertificateBASEEFA 13 ATEX 0080
MarkingII (1)G [Ex ia Ga] IIC Ex-Hexagon II (1)D [Ex ia Da] IIIC Ex-Hexagon I (M1) [Ex ia Ma]
CertificatePF 13 CERT 2760 X
Directive conformityEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
UL Approval Control Drawing116-0374 (cULus)
IECEx ApprovalIECEx BAS 13.0046
Rated voltage19 ... 30 V DC
Approved For[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Rippleless than equal 10 %
Rated current18 ... 14 mA
Power Dissipationless than equal 500 mW
Input Connection sidefield side
Input Connectionterminals 1+, 2-

-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive), Application-specific outputs, Line fault transparency (LFT), Usable as signal splitter (1 input and 2 outputs), Housing width 12.5 mm,This isolated barrier is used for intrinsic safety applications.
The device transfers digital signals (NAMUR sensors or dry contacts) from a hazardous area to a safe area.The input controls two passive transistor outputs with a resistive output characteristic.The outputs have three defined states 1-Signal = 6.5 V voltage drop, 0-Signal = 33 k and 6.5 V voltage drop and fault > 100 k This output characteristic offers line fault transparency on the signal lines.Via switches the mode of operation can be reversed and the line fault detection can be switched off.A fault is signalizthe ed by LEDs acc. to NAMUR NE44 and a separate collective error message output.

Features
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR input
  • 2 passive transistor outputs (resistive)
  • Application-specific outputs
  • Line fault transparency (LFT)
  • Usable as signal splitter (1 input and 2 outputs)
  • Housing width 12.5 mm
  • Up to SIL 2 acc.toIEC61508
  • Yokogawa ProSafe DI card SDV144

View Complete Details

Yes, I am interested!

Pepperl & Fuchs  KCD2-SOT-Ex1.LB Switch Amplifier
  • Pepperl & Fuchs  KCD2-SOT-Ex1.LB Switch Amplifier
  • Pepperl & Fuchs  KCD2-SOT-Ex1.LB Switch Amplifier
Interested in this product?
Get Best Quote
Brandpepperl& Fuchs
Signal TypeDigital Input
Safety Integrity LevelSIL 2
ConnectionPower Rail or terminals 9+, 10-
Rated voltage19 ... 30 V DC
Rippleless than equal 10 %
Rated current20 ... 15 mA
Power Dissipationless than equal 700 mW including maximum power dissipation in the output
Input Connection sidefield side
Input Connectionterminals 1+, 2-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage short circuit currentapprox. 10 V DC / approx. 8 mA
Switching point switching Hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line Fault Detectionbreakage I less than equal 0.1 mA , short-circuit I greater than equal 6.5 mA
Pulse Pause Ratiomin. 100 / min. 100
Output Connection sidecontrol side
Output Connectionoutput I: terminals 5, 6 ; output II: terminals 7, 8
Output Rated voltage30 V DC
Output Rated current50 mA
Response Timeless than equal 200
Signal Level1-signal: (external voltage) - 3 V max. for 50 mA ,0-signal: blocked output (off-state current g 10
Output Isignal ; Transistor
Output IIsignal or error message ; Transistor
Switching Frequencyless than equal 5 kHz
Display ElementsLEDs
Control ElementsDIP-switch
Configurationvia DIP switches
Labelingspace for labeling at the front
DirectiveEN 61326-1:2013 (industrial locations) 2014/30/EU
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529:2001
Ambient Temperature-20 ... 60 degreeC (-4 ... 140 degree F)
Mechanical Degree of protectionIP20
Mechanical Connectionscrew terminals
Massapprox. 100 g
Dimensions12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU Type Examination CertificateBASEEFA 13 ATEX 0080
MarkingII (1)G [Ex ia Ga] IIC Ex-Hexagon II (1)D [Ex ia Da] IIIC Ex-Hexagon I (M1) [Ex ia Ma] I
CertificatePF 13 CERT 2760 X
UL Approval Control Drawing116-0374 (cULus)
IECEx ApprovalIECEx BAS 13.0046
Approved For[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Protection Against Electrical ShockIEC 61010-1:2010

-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc.toIEC61508 This isolated barrier is used for intrinsic safety applications.The device transfers digital signals (NAMUR sensors or dry contacts) from a hazardous area to a safe area.The input controls two passive transistor outputs.Via switches the mode of operation can be reversed and the line fault detection can be switched off.Via switch the function of the second output can be defined as a signal output or an error output.A fault is signalized by LEDs acc. to NAMUR NE44 and a separate collective error message output.

Features
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR input
  • 2 passive transistor outputs
  • Usable as signal splitter (1 input and 2 outputs)
  • Reversible mode of operation
  • Line fault detection (LFD)
  • Housing width 12.5 mm
  • Up to SIL 2 acc.toIEC61508

View Complete Details

Yes, I am interested!

Pepperl & Fuchs  KCD2-SR-Ex1.LB.SP Switch Amplifier
  • Pepperl & Fuchs  KCD2-SR-Ex1.LB.SP Switch Amplifier
  • Pepperl & Fuchs  KCD2-SR-Ex1.LB.SP Switch Amplifier
Interested in this product?
Get Best Quote
Power45 mW (linear characteristic)
Brandpepperl& Fuchs
Safety Integrity LevelSIL 2
ConnectionPower Rail or terminals 9+, 10-
Rated voltage19 ... 30 V DC
Rippleless than equal to 10 %
Rated currentless than equal to 30 mA
Power Dissipationless than equal to 500 mW
Power consumptionless than equal to 500 mW
Input Connection sidefield side
Input Connectionterminals 1+, 2-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage short circuit currentapprox. 10 V DC / approx. 8 mA
Switching point switching Hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line Fault Detectionbreakage I less than equal to 0.1 mA , short-circuit I greater than equal to 6.5 mA
Pulse Pause Ratiomin. 20 ms / min. 20 ms
Output Safety NoteIf load voltage greater than 50 V, de-energize before removing the terminals.
Output Connection sidecontrol side
Output Connectionoutput I: terminals 5, 6 ; output II: terminals 7, 8
Output Isignal ; relay
Output IIsignal or error message ; relay
Energized De Energized Delayless than equal 20 ms / less than equal 20 ms
Mechanical Life107 switching cycles
Output power supplyreinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
Display ElementsLEDs
Control ElementsDIP-switch
Configurationvia DIP switches
Labelingspace for labeling at the front
DirectiveEN 61326-1:2013 (industrial locations) 2014/30/EU
Low voltage DirectiveEN 61010-1:2010 (2014/35/EU)
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529:2001
Ambient Temperature-20 ... 60 degreeC (-4 ... 140 degree F)
Mechanical Degree of protectionIP20
Mechanical Connectionspring terminals
Massapprox. 100 g
Dimensions12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU Type Examination CertificateBASEEFA 06 ATEX 0092
MarkingEx-Hexagon II (1)G [Ex ia Ga] IIC , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma
Input[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Voltage10.5 V
Current17.1 mA
Maximum safe voltage253 V AC (Attention! Um is no rated voltage.)
Output I II Maximum safe voltage253 V AC (Attention! Um is no rated voltage.)
Contact Loading253 V AC/2 A/cos greater th 0.7; 126.5 V AC/4 A/cos greater than 0.7; 30 V DC/2 A resistive load
CertificatePF 06 CERT 0972 X
Output I IIContact Loading50 V AC/2 A/cos greater than 0.7; 30 V DC/2 A resistive load
Input Outputreinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
Galvanic Isolation Input power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
FM Approval Control Drawing116-0419 (cFMus)
UL Approval Control Drawing116-0420 (cULus)
IECEx ApprovalIECEx BAS 06.0025
Approved For[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Supplementary InformationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applica
Safety noteIf load voltage greater than 50 V, de-energize before removing the terminals.
Minimum switch current2 mA / 24 V DC

channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, This isolated barrier is used for intrinsic safety applications.The device transfers digital signals (NAMUR sensors or dry contacts) from a hazardous area to a safe area.The proximity sensor or switch
controls a form A normally open relay contact for the safe
area load. The normal output state can be reversed using switch S1. Switch S2 allows output II to be switched between a signal output and an error message output. Switch S3 enab
les or disables line fault detection of the field circuit.During an error condition, relays revert to their de-energized state and LEDs indicate the fault according to NAMUR NE44.A unique collective error messaging feature is available when used with the Power Rail system.Due to its compact housing design and low heat dissipation, this device is useful for detecting positions, end stops, and switching states in space-critical applications.

Features
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Usable as signal splitter (1 input and 2 outputs)
  • Relay contact output
  • Fault relay contact output
  • Line fault detection (LFD)
  • Housing width 12.5 mm
  • Connection via spring terminals
  • Up to SIL 2 acc.toIEC61508


View Complete Details

Yes, I am interested!

Pepperl & Fuchs  KCD2-SR-Ex2.SP Switch Amplifier
  • Pepperl & Fuchs  KCD2-SR-Ex2.SP Switch Amplifier
  • Pepperl & Fuchs  KCD2-SR-Ex2.SP Switch Amplifier
Interested in this product?
Get Best Quote
Signal TypeDigital Input
Safety Integrity LevelSIL 2
ConnectionPower Rail or terminals 9+, 10-
Rated voltage19 ... 30 V DC
Rippleless than equal to 10 %
Rated currentless than equal to 30 mA
Power consumptionless than equal to 600 mW
Input Connection sidefield side
Input Connectionterminals 1+, 2-; 3+, 4-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage short circuit currentapprox. 10 V DC / approx. 8 mA
Switching point switching Hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line Fault Detectionbreakage I less than equal to 0.1 mA , short-circuit I greater than equal to 6.5 mA
Pulse Pause Ratiomin. 20 ms / min. 20 ms
Output Safety NoteIf load voltage greater than equal to 50 V, de-energize before removing the terminals.
Output Connection sidecontrol side
Output Connectionterminals 5, 6; 7, 8
Output IIsignal ; relay
Contact Loading253 V AC/2 A/cos greater th 0.7; 126.5 V AC/4 A/cos greater than 0.7; 30 V DC/2 A resistive load
Minimum switch current2 mA / 24 V DC
Energized De Energized Delayless than equal to 20 ms
Mechanical Life107 switching cycles
Switching Frequencyless than equal to 10 Hz
Galvanic Isolation InputBasic insulation according to EN 50178, rated insulation voltage 300 Veff
Display ElementsLEDs
Control ElementsDIP-switch
Configurationvia DIP switches
Labelingspace for labeling at the front
Low voltage DirectiveEN 61010-1:2010 (2014/35/EU)
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529:2001
Ambient Temperature-20 ... 60 degree C (-4 ... 140 degreeF)
Mechanical Degree of protectionIP20
Mechanical Connectionspring terminals
Massapprox. 100 g
Dimensions12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU Type Examination CertificateBASEEFA 06 ATEX 0092
MarkingEx-Hexagon II (1)G [Ex ia Ga] IIC , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma
CertificatePF 06 CERT 0972 X
Output I II Contact Loading50 V AC/2 A/cos greater than 0.7; 30 V DC/2 A resistive load
DirectiveEN 61326-1:2013 (industrial locations) ( 2014/30/EU)
FM Approval Control Drawing116-0419 (cFMus)
UL Approval Control Drawing116-0420 (cULus)
IECEx ApprovalIECEx BAS 06.0025
Approved For[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I

-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL 2 acc.toIEC61508, This isolated barrier is used for intrinsic safety applications.The device transfers digital signals (NAMUR sensors or dry contacts) from a hazardous area to a safe area.The proximity sensor or switch
controls a form A normally open relay contact for the safe
area load. The normal output state can be reversed using switch S1. Switch S2 allows output II to be switched between a signal output and an error message output. Switch S3 enab
les or disables line fault detection of the field circuit.During an error condition, relays revert to their de-energized state and LEDs indicate the fault according to NAMUR NE44.A unique collective error messaging feature is available when used with the Power Rail system.Due to its compact housing design and low heat dissipation, this device is useful for detecting positions, end stops, and switching states in space-critical applications.

Features
  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Line fault detection (LFD)
  • Housing width 12.5 mm
  • Connection via spring terminals
  • Up to SIL 2 acc.toIEC61508