X

Perfect Sales Corporation

New Delhi, Delhi

| GST  07AAJFP1251D1ZL

| Verified Supplier

View Mobile Number 100% Response Rate
Hi
I agree to the terms and privacy policy
Verifying...
1

Have a requirement?
Get Best Price

Transformers

Get Best Quote

Current Transformer

Get Best Quote

Oil Cooled Pt

Get Best Quote

Switchgear

Get Best Quote

Ct Meter Box

Get Best Quote
Perfect was formed in the year 1990 as a L. T. C. T. manufacturers. Inspired by the overwhelming response, the manufacturing range was further upgraded up to 33 kV class backed by team of technocrats.
Today, Perfect are recognized as one of the reputed manufacturing of instrument transformers.
Our Instrument Transformers up to 33 kV Class are fully type tested form CPRI And ERDA.
Our Plant is well equipped with morden manufacturing and testing equipment.
We have the privilege of having a long list of clients both in private and public sectors including State Electricity Boards.
Business TypePrimaryCompetitiveAdvantagesYear of EstablishmentOEM Service ProvidedProduction TypeProduct RangeExporter , Manufacturer , SupplierPremium qualityCompetitive pricesTimely delivery 1990YesSemi-automatic♠  Current Transformers: Current Transformers upto 33 KV class with Oil Cooled and Epoxy Resin Cast Current Transformers.♠  Potential Transformers: Potential Transformers upto 33 KV class with Oil Cooled and Epoxy Resin Cast Potential Transformers
+ Read More

Nature of Business

Manufacturer

Total Number of Employees

51 to 100 People

Year of Establishment

1990

Legal Status of Firm

Partnership Firm

Annual Turnover

Rs. 10 - 25 Crore

GST Number

07AAJFP1251D1ZL

Electronic Equipment

Electronic Equipment

Get Latest Price

Ask for Details

Reverse Osmosis Plant

Reverse Osmosis Plant

Get Latest Price

Ask for Details

Transformers

Transformers

Get Latest Price

Ask for Details

Current Transformer

Current Transformer

Get Latest Price

Ask for Details

Potential Transformer

Potential Transformer

Get Latest Price

Ask for Details

Oil Cooled Pt

Oil Cooled Pt

Get Latest Price

Ask for Details

Switchgear

Switchgear

Get Latest Price

Ask for Details

Ct Meter Box

Ct Meter Box

Get Latest Price

Ask for Details

11 Kv Resin Cast Ct
Interested in this product?
Get Best Quote

11 Kv Resin Cast Ct

Get Latest Price

11 kv resin cast ct
A current transformer is the measuring device for metering and protection system. The primary current of the ct is transformed into the required secondary current of 5 a or 1 a.

measuring ct's have different class of accuracy i. E. 0. 1, 0. 2s, 0. 2, 0. 5s, 0. 5 and 1. 0 and protection ct's have 5p10, 5p20 and 10p10. In the case of special protection ct's(ps class), the knee point voltage(vk) of the ct is specified alongwith secondary resistance and magnetizing current.

the construction of the ct not only depends upon the ratio but also on the short time current rating, burden and class of accuracy.

View Complete Details

Yes, I am interested!

33 Kv Oil Cooled Ct
Interested in this product?
Get Best Quote

33 Kv Oil Cooled Ct

Get Latest Price

33 kv oil cooled ct
A current transformer is the measuring device for metering and protection system. The primary current of the ct is transformed into the required secondary current of 5 a or 1 a.

measuring cts have different class of accuracy i. E. 0. 1, 0. 2s, 0. 2, 0. 5s, 0. 5 and 1. 0 and protection cts have 5p10, 5p20 and 10p10. In the case of special protection cts(ps class), the knee point voltage(vk) of the ct is specified along with secondary resistance and magnetizing current.

the construction of the ct not only depends upon the ratio but also on the short time current rating. Burden and class of accuracy.

View Complete Details

Yes, I am interested!

Lt Tape Wound And Resin Cast Ct
Interested in this product?
Get Best Quote

lt tape wound and resin cast ct
a current transformer is the measuring device for metering and protection system. The primary current of the ct is transformed into the required secondary current of 5 a or 1 a.

measuring cts have different class of accuracy i. E. 0. 1, 0. 2s, 0. 2, 0. 5s, 0. 5 and 1. 0 and protection cts have 5p10, 5p20 and 10p10. In the case of special protection ct's(ps class), the knee point voltage(vk) of the ct is specified along with secondary resistance and magnetizing current.

the construction of the ct not only depends upon the ratio but also on the short time current rating. Burden and class of accuracy.

View Complete Details

Yes, I am interested!

33 Kv Oil Cooled Pt
Interested in this product?
Get Best Quote

33 Kv Oil Cooled Pt

Get Latest Price

33 kv oil cooled pt
the primary and secondary winding of potential transformer is magnetically coupled by a core. Pt is used to further step down the system voltage to measurable value up to 63. 5 v, 100 v or 110 v as per standard of the equipment.

the typical class of accuracy of metering pt are 0. 1, 0. 2, 0. 5, 1. 0 and protection pt is 3p. The pts are offered in single phase or three phase version.

View Complete Details

Yes, I am interested!

11 Kv Resin Cast Pt
Interested in this product?
Get Best Quote

11 Kv Resin Cast Pt

Get Latest Price

11 kv resin cast pt
the primary and secondary winding of potential transformer is magnetically coupled by a core. Pt is used to further step down the system voltage to measurable value up to 63. 5 v, 100 v or 110 v as per standard of the equipment.

the typical class of accuracy of metering pt are 0. 1, 0. 2, 0. 5, 1. 0 and protection pt is 3p. The pts are offered in single phase or three phase version.

View Complete Details

Yes, I am interested!

11 Kv Ct-pt Combined Unit (oil Cooled / Dry Type)
Interested in this product?
Get Best Quote

11 kv ct-pt combined unit (oil cooled / dry type)
ct - pt combined unit are also called metering units. These units can be offered as dry type or oil immersed.

the metering unit consists of:

  • 02 nos. Single phase cts and 01 no. Three phase pt
  • 03 nos. Single phase cts and 01 no. Three phase pt
  • 02 nos. Ot 03 nos. Single phase ct's and 03 nos. Single phase pts.

ct - pt combined units are used for both indoor / outdoor application.

 

View Complete Details

Yes, I am interested!

22 Or 33 Kv Ct-pt Combined Unit (oil Cooled)
Interested in this product?
Get Best Quote

22 or 33 kv ct-pt combined unit (oil cooled)
ct-pt combined unit are also called metering units. These units can be offered as dry type or oil immersed.

the metering unit consists of:

  • 02 nos. Single phase ct's and 01 no. Three phase pt
  • 03 nos. Single phase ct's and 01 no. Three phase pt
  • 02 nos. Ot 03 nos. Single phase ct's and 03 nos. Single phase pts.

ct - pt combined units are used for both indoor / outdoor application.

 

View Complete Details

Yes, I am interested!

Oil Cooled Current Transformer
Interested in this product?
Get Best Quote

A Current Transformer is the measuring device for metering and protection system. The primary current of the CT is transformed into the required secondary current of 5 A or 1 A.

Measuring CT's have different class of accuracy I.e. 0.1, 0.2S, 0.2, 0.5S, 0.5 and 1.0 and protection CT's have 5P10, 5P20 and 10P10. In the case of special protection CT's(PS class), the Knee Point Voltage(KV) of the CT is specified along with secondary resistance and magnetizing current.

The construction of the CT not only depends upon the ratio but also on the Short Time Current Rating. Burden and Class of Accuracy.

View Complete Details

Yes, I am interested!

P.G. Clamp For Acsr Conductor
Ask for Details

T-connector For Acsr Conductor
Ask for Details

Lt Bushing Rod For Dist. Transformer
Ask for Details

Brass Lug For Dist. Transformer
Ask for Details

Current Transformers

Current Transformers

Get Latest Price

Ask for Details

11 kV Metering Cubicle With Bottom Cable Panel
Ask for Details

Pad Clamp

Pad Clamp

Get Latest Price

Ask for Details

Single Phase Energy Meter Box
Ask for Details

LT Tape Wound Current Transformer
Ask for Details

Resin Cast CT

Resin Cast CT

Get Latest Price

Ask for Details

Oil Cooled

Oil Cooled

Get Latest Price

Ask for Details

11 Kv Oil Cooled Ct

11 Kv Oil Cooled Ct

Get Latest Price

Ask for Details

33 Kv Oil Cooled Ct

33 Kv Oil Cooled Ct

Get Latest Price

Ask for Details

Current Transformer

Current Transformer

Get Latest Price

Ask for Details

Current Transformer Copper Wire
Ask for Details

Transformers Copper Wire

Transformers Copper Wire

Get Latest Price

Ask for Details

Sectional Current Transformer
Ask for Details

11 Kv Metering Cubicle With Side Cable Entry
Interested in this product?
Get Best Quote

11 kv metering cubicle with side cable entry
metering cubicle is a combination of ct - pt unit and metering chamber.

the ct - pt chamber consists

  • 02 nos. Single phase ct's and 01 no. Three phase pt
  • 03 nos. Single phase ct's and 01 no. Three phase pt
  • 02 or 03 nos. Single phase ct's and 03 nos. Single phase pts.

 

 

View Complete Details

Yes, I am interested!

11 Kv Metering Cubicle With Bottom Cable Entry
Interested in this product?
Get Best Quote

11 kv metering cubicle with bottom cable entry
metering cubicle is a combination of ct - pt unit and metering chamber.

the ct - pt chamber consists of:

  • 02 nos. Single phase cts and 01 no. Three phase pt
  • 03 nos. Single phase cts and 01 no. Three phase pt
  • 02 or 03 nos. Single phase ct's and 03 nos. Single phase pts.

 

View Complete Details

Yes, I am interested!

Turbulator

Turbulator

Get Latest Price

Ask for Details

Bus Bar Spout for 11kV Switchgears
Ask for Details

Trolley Isolator Bushing

Trolley Isolator Bushing

Get Latest Price

Ask for Details

Current Transformer Measuring Device
Ask for Details

Get Price & Details

Get Price & Details

Get Price & Details

Get Price & Details

Get Price & Details

Get Price & Details

Get Price & Details

Get Price & Details

Get Price & Details

Get Price & Details
Tell us what you
need
Receive seller
details
Seal the deal
Pay with IndiaMART
Save time! Get Best Deal
I agree to the terms and privacy policy