IndiaMART > Surgical & Medical Consumables > Guide Wire
300 Cm DURASTEEL(Core Material) Abbott Pilot 150 Guide Wire

300 Cm DURASTEEL(Core Material) Abbott Pilot 150 Guide Wire

Rs 2,600/Piece Get Latest Price
Model Name/Number Hi Torque Pilot 150
Material DURASTEEL(Core Material)
Guide Wire Yes
Length 300 cm
Packaging Type Box
Coating Hydrophilic
Contact SellerAsk for best deal
Get Latest PriceRequest a quote

Advit Medlife

Rohini, New Delhi
Company Video
View Mobile Number
Call +91-8048742294
Star Supplier
TrustSEAL Verified
Wholesale Trader
67% Response Rate
Ask for more details from the seller
Contact Seller

Product Details

Product Specification

Model Name/Number Hi Torque Pilot 150
Material DURASTEEL(Core Material)
Guide Wire Yes
Length 300 cm
Packaging Type Box
Coating Hydrophilic
Usage/Application Hospital
Disposables Yes
Brand Abbott
Certified By CE
Cover Type or Coils Full Polymer
Tip Style Core-To-Tip
Tip Load 2.7 g
Width 0.014 inch
Minimum Order Quantity 10 Piece

Product Description

INDICATIONS FOR USE

Intended to facilitate the delivery of catheter-based interventional devices during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA). This guide wire may be used with compatible stent devices during therapeutic procedures. The guide wire may be used to reach and cross a target lesion, provide a pathway within the vessel structure, facilitate the substitution of one diagnostic or interventional device for another, and to distinguish the vasculature. This guide wire may also be used to cross or assist in crossing de novo chronic total coronary occlusions (CTO).

CONTRAINDICATIONS

Not intended for use in the cerebral vasculature or with atherectomy devices.

WARNINGS

This device is designed and intended for ONE-TIME USE ONLY. Do not resterilize and / or reuse.

Carefully observe the instructions under “Do Not” and “Do” below. Failure to do so may result in vessel trauma, guide wire damage, guide wire tip separation, or stent damage. If resistance is observed at any time, determine the cause under fluoroscopy and take remedial action as needed. Use the most suitable guide wire for the lesion being treated.

Do Not:

  • Push, auger, withdraw, or torque a guide wire that meets resistance.
  • Torque a guide wire if the tip becomes entrapped within the vasculature.
  • Allow the guide wire tip to remain in a prolapsed condition.

Do:

  • Advance or withdraw the guide wire slowly.
  • Use the radiopaque marker of the interventional device to confirm position.
  • Examine the tip movement under fluoroscopy before manipulating, moving, or torquing the guide wire.
  • Observe the wire under fluoroscopy for tip buckling, which is a sign of resistance.
  • Maintain continuous flush while removing and reinserting the guide wire to prevent air from entering the catheter system. Perform exchanges slowly to prevent air entry and / or trauma.
  • When reintroducing the guide wire, confirm that the interventional device tip is free within the vessel lumen and that the tip is parallel to the vessel wall.
  • Use extreme caution when moving a guide wire through a non-endothelialized stent, or through stent struts, into a bifurcated vessel. Use of this technique involves additional patient risks, including the risk that the wire may become caught on the stent strut.
  • Consider that if a secondary wire is placed in a bifurcation branch, this wire may need to be retracted prior to stent deployment, because there is additional risk that the secondary wire may become entrapped between the vessel wall and the stent.

 

For the PROGRESS family only: The PROGRESS family of guide wires has distal ends of varying stiffness. Operate these guide wires carefully so as to not injure the blood vessel, observing the information in these instructions. The higher torque performance, stiffer distal ends, and / or higher advancement force may present a higher risk of perforation or injury than a guide wire with a more pliable distal end. Therefore, use the guide wire with the least stiff distal end that will treat the lesion, and use extreme care to minimize the risk of perforation or other damage to blood vessels.


PRECAUTIONS

Guide wires are delicate instruments and should be handled carefully. Prior to use and when possible during the procedure, inspect the guide wire carefully for bends, kinks, or other damage. Do not use damaged guide wires. Using a damaged guide wire may result in vessel damage and / or inaccurate torque response.

Confirm the compatibility of the guide wire diameter with the interventional device before actual use.


Interested in this product?Get Latest Price from the seller
Contact Seller

Product Image

300 Cm DURASTEEL(Core Material) Abbott Pilot 150 Guide Wire

Company Details


About the Company

Year of Establishment2018
Legal Status of FirmIndividual - Proprietor
Nature of BusinessWholesale Trader
Number of EmployeesUpto 10 People
Annual TurnoverRs. 5 - 10 Crore
IndiaMART Member SinceAug 2015

Advit Medlife is one of the renowned traders of a wide range of Diagnostic Catheter, Guide Wire, Inflation Device etc. These products are designed and manufactured in line with the latest trends and standards of the industry. The entire range of products offered by us is very popular in the markets for their afford ability and high durability nature.

Company Video

Send your enquiry to this supplier
I agree to the terms and privacy policy

Seller Contact Details

Abhinay Mishra

Shop No. 14, Ground Floor, CSC No. 03, Pocket H-17, Sector 7
Rohini
New Delhi - 110085, India

Get Directions
View Mobile No.
Call +91-8048742294
Send SMS
Send Email
Tell us what you
need
Receive seller
details
Seal the deal
Save time! Get Best Deal
I agree to the terms and privacy policy




X
Hi
I agree to the terms and privacy policy
Verifying...
1

Have a requirement?
Get Best Price

Hi
I agree to the terms and privacy policy
Verifying...
1

Have a requirement?
Get Best Price