Ables Flash And Fire Point Apparatus

Get Latest Price
Volume
4 L
Frequency
50 Hz
Voltage
240 V
Automation Type
Semi-Automatic
Power
800 W
Description:
Scope:
- This method of test is designed for the determination of the closed flash points of cutback bitumen’s of which the flash points do not exceed 230’ F ( 110’ C). Use is made of a modified form of the Abel apparatus.
- The results obtained by this method do not differ appreciably from the minimum flash point of the material under equilibrium conditions of temperature and vapour pressure.
Outline of Method:
The sample is place in the cup of an Abel flash point apparatus and heated at a very slow uniform rate with stirring. A small test – flame is directed into the cup at regular intervals, and the flash point is taken as the lowest temperature at which application of the test flame causes the vapour above the sample to ignite.
Apparatus:
* Flash Point Apparatus- The apparatus to be employed shall be an able flash point apparatus with stirrer, as described in IP 33, Appendix I, but provided with means for mechanical stirring.
* Provision shall also be made for maintaining a good circulation in the water-bath, e.g. by means of a gentle stream of air being introduced through a fine tube entering the bath through a hole bored for the purpose.
* Thermometers – Conforming to the specification IP 43, F or C, and IP 44, F or C.
Sample:
In view of the case with which volatile matter can be lost from some cutback bitumen’s, all possible precautions should be taken against excessive handling of the sample in order to minimize its exposure to the atmosphere. In all cases, samples for the flash point test must be submitted in closed containers and it is strongly recommended, particularly in cases of dispute, that a separate sample (at least 4 oz (100g) should be made available for this test.
Procedure:
* If the sample is too viscous for ease of pouring at laboratory temperature, warm it gently in its closed container in a water-bath taking care not to raise the temperature of the sample higher than 20’ F (11’C) below its flash point.
Calculation and Reporting:
* Correct the observed flash point to standard atmospheric pressure using the following rule:
* For each inch (25 mm) below 29.92 inches (760 mm) barometric reading, add 1.6’ F (0.9’C) to the flash point.
* For each inch (25 mm) above 29.92 inches (760 mm) barometric reading, sub tract 1.6’ F (0.9’C) from the flash point.
* Report the corrected flash point to the nearest 1’F (0.5’C) as flash point (Closed) of cutback Bitumen, IP 113.

Exports To: Bangladesh | Sri Lanka | Nepal | Tanzania | Qatar

View Complete Details
Get Latest PriceRequest a quote

Sunshine Instruments

Gopalapuram, Coimbatore, Tamil Nadu
4/5 
★★★★★
★★★★★
 (87)
GST33ADQPV5864Q1ZC
TrustSEAL Verified
Verified Exporter
Distributor / Channel Partner
Company Video
 View Mobile Number 
69% Response Rate
Contact Supplier

Product Details

Company Details

Product Specification

Volume4 L
Frequency50 Hz
Voltage240 V
Automation TypeSemi-Automatic
Power800 W
Temperature Range28C Range -6 to 400C
Country of OriginMade in India

Product Description

Description:

Scope:


  • This method of test is designed for the determination of the closed flash points of cutback bitumen's of which the flash points do not exceed 230' F ( 110' C).  Use is made of a modified form of the Abel apparatus.
  • The results obtained by this method do not differ appreciably from the minimum flash point of the material under equilibrium conditions of temperature and  vapour pressure.

Outline of Method:

The sample is place in the cup of an Abel flash point apparatus and heated at a very slow uniform rate with stirring.  A small test – flame is directed into the cup at regular intervals, and the flash point is taken as the lowest temperature at which application of the test flame causes the vapour above the sample to ignite.

Apparatus:

  • Flash Point Apparatus-  The apparatus to be employed shall be an able flash point apparatus with stirrer, as described in IP 33, Appendix I, but provided with means for mechanical stirring. 
  • Provision shall also be made for maintaining a good circulation in the water-bath, e.g.   by means of a gentle stream of air being introduced through a fine tube entering the bath through a hole bored for the purpose.
  • Thermometers – Conforming to the specification IP 43, F or C, and IP 44, F or C.

Sample:

In view of the case with which volatile matter can be lost from some cutback bitumen's, all possible precautions should be taken against excessive handling of the sample in order to minimize its exposure to the atmosphere.  In all cases, samples for the flash point test must be submitted in closed containers and it is strongly recommended, particularly in cases of dispute, that a separate sample (at least 4 oz (100g) should be made available for this test.

Procedure:

  • If the sample is too viscous for ease of pouring at laboratory temperature, warm it gently in its closed container in a water-bath taking care not to raise the temperature of the sample higher than 20' F (11'C) below its flash point.

Calculation and Reporting:

  • Correct the observed flash point to standard atmospheric pressure using the following rule:
  • For each inch (25 mm) below 29.92 inches (760 mm) barometric reading, add 1.6' F (0.9'C) to the flash point.
  • For each inch (25 mm) above 29.92 inches (760 mm) barometric reading, sub tract 1.6' F (0.9'C) from the flash point.
  • Report the corrected flash point to the nearest 1'F (0.5'C) as flash point  (Closed) of cutback Bitumen, IP 113.


                         
Interested in this product?Get Latest Price from the seller
Contact Seller

About the Company

Year of Establishment2007
Legal Status of FirmIndividual - Proprietor
Nature of BusinessDistributor / Channel Partner
Number of EmployeesUpto 10 People
IndiaMART Member SinceApr 2010
GST33ADQPV5864Q1ZC
Import Export Code (IEC)32120*****
Exports to Bangladesh | Sri Lanka | Nepal | Tanzania | Qatar
Since 2012, we, Sunshine Instruments, have been reputed supplier, importer, exporter & trader of Agricultural, Analytical, Diagnostic, Digital, Water and Weather Measuring Instruments. In our range, we offer Hand Refractometer, Soil PH Meter, Grain Moisture Meter MC 7825G, Atago Master Series Refractometer, PEN PH Meter, Anemometer Lutron AM 4201, Digital Lux Meter LX 101A, Digital Rain Gauge Oregon RGR 126 and Waterproof PH Testers. Moreover, we hold expertise in providing Fluorescence Spectrometer, Brookfield Viscometer, UV Mini 1240, Microplate Reader and Automatic Transmittance Colorimeter. We provide the products under the brand name of 1 Lab Instruments, Philips, Racer, Eutech Instruments, Blue Star, Atago, Labomed, Whatman, Barigo, Thermo and many more.These instruments are widely acknowledged in the market for their features such as trouble free performance, high accuracy and longer service life. The instruments supplied by us find wide application in petrochemical units, industrial labs, R&D labs, national test house, defense labs and universities. Our enterprise has appointed a group of skilled professionals, which keeps a watchful eye on the complete production process.
Indebted to our customer-centric approach, we have been able to gain expertise in providing a variety of scales. We have established a sprawling storage unit laced with sophisticated machines and tools. The experienced professionals engaged with us assure to thoroughly examine the entire product line for any flaw and defect. Providing customers with quality-rich products within promised time frame has been our target thus, for this, we have developed a far-reaching distribution network. Due to the unwavering efforts and tireless spirit of our enterprise towards work, we have carved a special niche for ourselves in the industry. Besides, patrons can pay us through varied convenience modes such as cash, cheque and DD as per their convenience. Our enterprise is a sole agent for different trusted manufacturer from Malaysia, German, Taiwan, Japan, USA and England.

Company Video

Ables Flash And Fire Point Apparatus
Ables Flash And Fire Point Apparatus
termsprivacy policy

Seller Contact Details

Devang Thakkar

P.b. No. 3910, No. 83, Chinny's Chamber, Dr. Nanjappa Road Near Corporation Complex, Gopalapuram Coimbatore - 641018, Tamil Nadu, India

Get Directions
View Mobile No.
Send SMS
Send Email