ImageSlid1
ImageSlid2
Product Video

Bruker Instrument Diffusible Hydrogen Analyzer G4 Phoenix, 230V

Get Latest Price
Model Name/Number
G4 Phoenix
Brand
Bruker
Machine Type
Instrument
Usage/Application
Measurement of Diffusible Hydrogen
Power Supply
230V
High Performance Analyzer for diffusible Hydrogen The G4 PHOENIX DH hot extraction analyzer is the right solution for accurate and rapid diffusible hydrogen measurement to avoid embrittlement, hydrogen-induced cracking and other costly failures. Hydrogen-induced damage is a wide-spread and dreaded phenomenon. It manifests in such a manner that a component fails under the influence of mechanical stress - even without visible indication. Thus, hydrogen in steel or welds is critical to assess because of embrittlement, hydrogen induced or assisted cracking (HIC/HAC) or hydrogen delayed fracture among other damaging effects. Obtaining precise information about the hydrogen concentration in the material is crucial for quality control and the development of new materials. The G4 PHOENIX DH, utilizing the carrier gas hot extraction method, enables a rapid and automatic determination of diffusible hydrogen in a wide variety of matrices. The evolved diffusible hydrogen is detected with a sensitive and long-term stable thermal conductivity detector (TCD). Simple and reliable calibration is guaranteed by the integrated, automatic gas dosing unit with 10 different volumes. The analyzer is equipped with a rapid heating (and cooling) infrared-heated clamshell furnace (up to 900C). The quartz tube diameter of 30 mm enables the analysis of large samples like steel sheet strips as well as weld coupons according to ISO 3690 and AWS A4.3. The versatile infrared furnace also enables the use of temperature programs and ramping to assess information about different forms of trapped hydrogen. For higher temperatures, especially for the determination of diffusible and residual Hydrogen, e.g. in steel, the G4 PHOENIX DH can be equipped with an additional wire-heated tube furnace, which can be operated at temperatures up to about 1100C. The revolutionary new technique of coupling a mass spectrometer to the carrier gas hot extraction analyzer G4 PHOENIX DH leads to a substantially improved detection limit for the determination of ultra-low hydrogen concentrations e.g., in high strength steels. This Thermal Desorption Mass Spectrometry (TDMS) technique improves the detection limit by more than one order of magnitude compared to a TCD. Software The intuitive analysis software of the G4 ICARUS HF provides a clear user interface. Different tasks from the users workflow like measurement, method setup, calibration and data evaluation are clearly divided into different views. Features & Benefits Rapid heating (and cooling) infrared tube furnace offers extensive analytical functionality in temperature programming (ramps and steps) Quartz tube diameter of 30 mm enables the analysis of large samples such as steel sheet strips and weld coupons according to AWS A4.3 and ISO 3690 Automatic and reliable gas calibration with hydrogen or helium by means of the integrated gas dosing unit with 10 different volumes Optional quadrupole mass spectrometer improves the detection limit by more than one order of magnitude, thus enabling evaluation of ultra-low hydrogen concentrations and the study and characterization of hydrogen traps in steel
View Complete Details
Get Latest PriceRequest a quote

Dynamic Technology Systems

Mahim, Mumbai, Maharashtra
3.7/5 
★★★★★
★★★★★
 (9)
GST27AAGFD4809C1ZQ
TrustSEAL Verified
Distributor / Channel Partner
 View Mobile Number 
52% Response Rate
Contact Supplier

Product Details

Company Details

Product Specification

Model Name/NumberG4 Phoenix
BrandBruker
Machine TypeInstrument
Usage/ApplicationMeasurement of Diffusible Hydrogen
Power Supply230V
FeaturesDetection of diffusible Hydrogen in Weldments
Warranty1
Analysis Time1 minute
Minimum Order Quantity 1 Piece

Product Description

High Performance Analyzer for diffusible Hydrogen The G4 PHOENIX DH hot extraction analyzer is the right solution for accurate and rapid diffusible hydrogen measurement to avoid embrittlement, hydrogen-induced cracking and other costly failures. Hydrogen-induced damage is a wide-spread and dreaded phenomenon. It manifests in such a manner that a component fails under the influence of mechanical stress - even without visible indication. Thus, hydrogen in steel or welds is critical to assess because of embrittlement, hydrogen induced or assisted cracking (HIC/HAC) or hydrogen delayed fracture among other damaging effects. Obtaining precise information about the hydrogen concentration in the material is crucial for quality control and the development of new materials. The G4 PHOENIX DH, utilizing the carrier gas hot extraction method, enables a rapid and automatic determination of diffusible hydrogen in a wide variety of matrices. The evolved diffusible hydrogen is detected with a sensitive and long-term stable thermal conductivity detector (TCD). Simple and reliable calibration is guaranteed by the integrated, automatic gas dosing unit with 10 different volumes. The analyzer is equipped with a rapid heating (and cooling) infrared-heated clamshell furnace (up to 900C). The quartz tube diameter of 30 mm enables the analysis of large samples like steel sheet strips as well as weld coupons according to ISO 3690 and AWS A4.3. The versatile infrared furnace also enables the use of temperature programs and ramping to assess information about different forms of trapped hydrogen. For higher temperatures, especially for the determination of diffusible and residual Hydrogen, e.g. in steel, the G4 PHOENIX DH can be equipped with an additional wire-heated tube furnace, which can be operated at temperatures up to about 1100C. The revolutionary new technique of coupling a mass spectrometer to the carrier gas hot extraction analyzer G4 PHOENIX DH leads to a substantially improved detection limit for the determination of ultra-low hydrogen concentrations e.g., in high strength steels. This Thermal Desorption Mass Spectrometry (TDMS) technique improves the detection limit by more than one order of magnitude compared to a TCD. Software The intuitive analysis software of the G4 ICARUS HF provides a clear user interface. Different tasks from the users workflow like measurement, method setup, calibration and data evaluation are clearly divided into different views. Features & Benefits Rapid heating (and cooling) infrared tube furnace offers extensive analytical functionality in temperature programming (ramps and steps) Quartz tube diameter of 30 mm enables the analysis of large samples such as steel sheet strips and weld coupons according to AWS A4.3 and ISO 3690 Automatic and reliable gas calibration with hydrogen or helium by means of the integrated gas dosing unit with 10 different volumes Optional quadrupole mass spectrometer improves the detection limit by more than one order of magnitude, thus enabling evaluation of ultra-low hydrogen concentrations and the study and characterization of hydrogen traps in steel

Additional Information

Item Code G4-PHOENIX-DH
Interested in this product?Get Latest Price from the seller
Contact Seller

Product Video


About the Company

Year of Establishment2008
Legal Status of FirmPartnership Firm
Nature of BusinessDistributor / Channel Partner
Number of Employees11 To 25 People
Annual TurnoverRs. 5 - 10 Crore
IndiaMART Member SinceMar 2013
GST27AAGFD4809C1ZQ
Import Export Code (IEC)03080*****
Dynamic Technology System (DTS) is engaged in pre-sales, sales and support of advanced technology systems for Material Research, Testing, Analysis & Inspection, serving the needs of the scientists and engineers in Analytical fields, QA/QC, R&D, Process, Test & Measurement etc. The products offered cover a range user friendly but niche and hi-tech equipment from reputed manufacturers across Europe, USA, Japan etc. Our principal's have competency of more 25- 40 years in their respective areas and have been active in their world market for many years. Our headquarters is in center of Mumbai, the financial capital of India. It provides excellent business environment and is well connected to every major industrial city in India. Our pan India coverage is complete with offices in Delhi, Kolkata, Chennai, Pune, Rajkot, Ahmedabad, Nagpur, Bangalore and Coimbatore. Our International network: Nepal, Bangladesh, Sri-Lanka. Russia, Dubai & Nigeria.
Bruker Instrument Diffusible Hydrogen Analyzer G4 Phoenix, 230V
Bruker Instrument Diffusible Hydrogen ...
termsprivacy policy

Seller Contact Details

Suyash Nadkarni

101, New Udyog Mandir- 2, Mogul Lane, Mahim West, Mahim Mumbai - 400016, Maharashtra, India

Get Directions
View Mobile No.
Send SMS
Send Email