ASICO Analog CRO 20MHz, Dual Channel, 2 Trace, For laboratory, Model Name/Number: AE 472
Model Name/Number | AE 472 |
Brand | ASICO |
Bandwidth | 20 MHZ |
Usage/Application | laboratory |
Warranty | no warranty |
Cathode Ray Oscilloscopes :-
a) Screen: Diameter 5, green phosphor
b) Vertical Frequency Response:
1) + 3db 4 Hz 1.2 MHz.
2) + 6db 3 Hz 2 MHz.
c) Sensitivity : 0.09 RMS volts per inch at 1 KHz
d) Input Impendence at 1 MHz :
1) 2.6 Meg ohms at x 1
2) 3.3 Meg ohms at x 10 and x 100
e) Horizontal Frequency :
+ db 2 to 245 KHz
f) Response : + 6 bd 1 650 KHz.
g) Sensitivity : 0.275 RMS volts per inch at 1 Khz Input Impedance 25 Mfd shunting 10 Meg ohms Sweep Generator Multivariate 20 hz to over 150 Khz
h) Input : 230 volts A.C. 50 hz.
Cathode Ray Oscilloscope :-
a) Screen :Diameter 3 green Phosphor
b) Sensitivity :10 mv RMS / cm
c) Band width : 5 hz. to 50 Khz (3 db)
d) Input Impedance : 5M / 20 PF Normal
e) Distortion : 1% Max 3 cm trace
f) Time Base : 20 Hz to 75 Khz
g) Beam Shift : Full width of screen on X & Y axis
h) X - axis : Linear time base 50 Hz sine
i) Attenuation : In Y Amplifier
j) Test Signals :50 Hz. 1V and 10 V R.M.S. full filtered
k) Input :230 volts A C/50 hz
Product Details
Company Details
Product Specification
Model Name/Number | AE 472 |
Brand | ASICO |
Bandwidth | 20 MHZ |
Usage/Application | laboratory |
Warranty | no warranty |
Channels | Dual |
Type | Analog |
Material | Metal |
Minimum Order Quantity | 1 Piece |
Product Description
Cathode Ray Oscilloscopes :-
a) Screen: Diameter 5, green phosphor
b) Vertical Frequency Response:
1) + 3db 4 Hz 1.2 MHz.
2) + 6db 3 Hz 2 MHz.
c) Sensitivity : 0.09 RMS volts per inch at 1 KHz
d) Input Impendence at 1 MHz :
1) 2.6 Meg ohms at x 1
2) 3.3 Meg ohms at x 10 and x 100
e) Horizontal Frequency :
+ db 2 to 245 KHz
f) Response : + 6 bd 1 650 KHz.
g) Sensitivity : 0.275 RMS volts per inch at 1 Khz Input Impedance 25 Mfd shunting 10 Meg ohms Sweep Generator Multivariate 20 hz to over 150 Khz
h) Input : 230 volts A.C. 50 hz.
Cathode Ray Oscilloscope :-
a) Screen :Diameter 3 green Phosphor
b) Sensitivity :10 mv RMS / cm
c) Band width : 5 hz. to 50 Khz (3 db)
d) Input Impedance : 5M / 20 PF Normal
e) Distortion : 1% Max 3 cm trace
f) Time Base : 20 Hz to 75 Khz
g) Beam Shift : Full width of screen on X & Y axis
h) X - axis : Linear time base 50 Hz sine
i) Attenuation : In Y Amplifier
j) Test Signals :50 Hz. 1V and 10 V R.M.S. full filtered
k) Input :230 volts A C/50 hz
Additional Information
Delivery Time | ready stock |
Packaging Details | 1 box |
About the Company
We are one of the foremost Manufacturers, Exporters and Suppliers of Amplifiers, Analog Lab Training Modules, Communication Lab Training Modules, Digital Lab Training Modules, E/M Experiments & Oscillators, Electrical Bridges and Power Supplies. In our product range, we provideEngineering college apparatus,Engineering lab apparatus,I.T.I lab apparatus,I.T.I college apparatus, ploytechnic lab apparatus,ploytechnic college apparatus,scientific instruments,electronics apparatus,physics Instruments,control system lab,PCB Lab,Instrumentation Lab,Network Theorems,Microwave Lab,Electrical Bridges,Portable Meters,Function Generators, Communication Lab,Filter circuits,digital electronics, multivibrators,oscillators, E/M Experiments, Operational amplifier kits,amplifiers,power supply,Dynamic Demonstrator.
?
With the support of our team of professionals and our well established manufacturing unit, we are capable to manufacture and supply a high quality product range to our valuable clients. These products are manufactured from high grade raw material in our well developed manufacturing division as per the international quality standards. Our product range is valued for its Quality standards, high Efficiency, Corrosion resistance and Tensile strength that enable us to create a huge client base across the Indian subcontinent.?