Emergency Tripping Systems

Get Latest Price

Emergency Tripping System (ETS) is used to achieve an electrical tripping scheme to de-energise the OCS section during emergency conditions. ETS will cover the entire underground portion of Line-3.
Emergency Tripping System consists of ETS stations (ETS Boxes) and the PLC/RTU which is a part of the SCADA System. Upon activation , ETS will proceed through a pre-determined programme of operation of Circuit Breakers and relevant interrupters to de-energise the OSC Sections. Further, it will interface with signalling and the essential interlocking to prevent any train coming on directly or through a cross over leading to the affected OCS section where ETS has been activated. SYSTEM OPERATIONThe main features of the ETS are :a) Electrical Trippingb) Communication through HotlineThe Emergency Tripping System enables electrical tripping of power supply of the traction time in case of emergency. This is achieved by breakage of the glass fitted on the front cover of the ETS Box, opening of the front cover using the handle provided inside and pressing of the Emergency Push Button (EPB). This action will trip the 25KV Traction time through a pre-determined operation of circuit breakers and relevant interrupters to de-energise the corresponding section.IN CASE OF EMERGENCYBreak Glass with Hammer.Press the handle downward to open Door.Press the Push Button Switch to Trip off 25KV traction Line.Lift telephone receiver to communicate.

View Complete Details
Get Latest PriceRequest a quote

Southern Electronics (Bangalore) Private Limited

Bengaluru, Karnataka
GST29AADCS1905Q1ZW
Verified Supplier
Manufacturer
 View Mobile Number 
Contact Supplier

Product Details

Company Details

Product Description

Emergency Tripping System (ETS) is used to achieve an electrical tripping scheme to de-energise the OCS section during emergency conditions. ETS will cover the entire underground portion of Line-3.

Emergency Tripping System consists of ETS stations (ETS Boxes) and the PLC/RTU which is a part of the SCADA System. Upon activation , ETS will proceed through a pre-determined programme of operation of Circuit Breakers and relevant interrupters to de-energise the OSC Sections. Further, it will interface with signalling and the essential interlocking to prevent any train coming on directly or through a cross over leading to the affected OCS section where ETS has been activated.

SYSTEM OPERATION

The main features of the ETS are :

a) Electrical Tripping

b) Communication through Hotline

The Emergency Tripping System enables electrical tripping of power supply of the traction time in case of emergency. This is achieved by breakage of the glass fitted on the front cover of the ETS Box, opening of the front cover using the handle provided inside and pressing of the Emergency Push Button (EPB). This action will trip the 25KV Traction time through a pre-determined operation of circuit breakers and relevant interrupters to de-energise the corresponding section.

IN CASE OF EMERGENCY

Break Glass with Hammer.

Press the handle downward to open Door.

Press the Push Button Switch to Trip off 25KV traction Line.

Lift telephone receiver to communicate.



Interested in this product?Get Latest Price from the seller
Contact Seller

About the Company

Year of Establishment1971
Legal Status of FirmLimited Company (Ltd./Pvt.Ltd.)
Nature of BusinessManufacturer
Number of Employees101 To 500 People
Annual TurnoverRs. 50 - 100 Crore
IndiaMART Member SinceSept 2012
GST29AADCS1905Q1ZW
Import Export Code (IEC)07890*****
Emergency Tripping Systems
Emergency Tripping Systems
termsprivacy policy

Seller Contact Details

Jackson James

16-a, Peenya Industrial Area, Phase-1, Bengaluru - 560058, Karnataka, India

Get Directions
View Mobile No.
Send SMS
Send Email