Marposs TCI-8 Transducer Conditioning Interface To PLC

Get Latest Price
Brand
Marposs
Measuring Range
(1 mm, 2mm, 3 mm, 5 mm, 10 mm)
Tension Mode
-+5V,-+10V, 0-10V, Maximum output current -+1 mA
Typical Consume With Transducer Connected Voltage
Voltage output: -+ 270 mA max. Current output: -+450 mA max.
If Configured With A Tension Output Signal
(-+12 V)-+12 Vdc -+5% Max. ripple allowed at 100/120 Hz: 50 mVpp
TCI is a line of signal conditioning interfaces consisting of three models with either one, four or eight channels.
It has been developed with technical and functional specifications particularly suited to convert a position or a dimensional measurement, performed by LVDT or HBT transducers, in a signal compatible with most of the analogue data acquisition cards. The unit output provides a direct electric signal (voltage or current), proportional to the measurement value of the sensor connected in input. The output signal can be acquired by PLC analogue cards to control and manage process automations and for further processing by SCADA supervision systems.The TCI interfaces are PLUG&PLAY units and therefore are supplied already calibrated for the model of sensor being used. This ensures that the machine down times are drastically reduced as the installation and maintenance operations are simplified.Features
- easy to install as it is calibrated during the production based on the model of sensor being used
- compatible with most of the sensors available on the market
* highly customisable
* reliable and sturdy
* one channel
* four channels
* eight channels
View Complete Details
Get Latest PriceRequest a quote

Marposs India Private Limited

Gurgaon, Gurugram, Haryana
3.4/5 
★★★★★
★★★★★
 (5)
GST06AAFCM1601B1ZA
Verified Supplier
Manufacturer
 View Mobile Number 
77% Response Rate
Contact Supplier

Product Details

Company Details

Product Specification

BrandMarposs
Measuring Range(1 mm, 2mm, 3 mm, 5 mm, 10 mm)
Tension Mode-+5V,-+10V, 0-10V, Maximum output current -+1 mA
Typical Consume With Transducer Connected VoltageVoltage output: -+ 270 mA max. Current output: -+450 mA max.
If Configured With A Tension Output Signal(-+12 V)-+12 Vdc -+5% Max. ripple allowed at 100/120 Hz: 50 mVpp
BandwidthTypical 500 Hz
Dual Filtered And Stabilised(-+15 V)-+15 Vdc -+5% Max. ripple allowed at 100/120 Hz: 50 mVpp
Current Mode(4/20 mA) Load impedance max. 250 ohm, min. 100 ohm
Type Of Power Supply(-+ 15Vdc -+ 5%, -+ 12Vdc -+ 5%, 24Vdc -+ 10%)
Gain Driftmax 0.04% degree C of the end scale
Offset Driftmax 0.01% degree C of the end scale
Linearity Errormax 0.1% of the end scale
Relative Operating Humidity(without condensation): 20% / 80%
Operating Temperature0 degree / + 50 degree C
Transducer Voltage SupplyTypical 3.4 Vrms
Transducer FrequencyTypical 5.0 KHz
Power Supply Voltage-+ 15Vdc -+ 5%, -+ 12Vdc -+ 5%, 24Vdc -+ 10%
Tension Output Signal-+ 5V, -+ 10V, 0-10V (maximum output current -+ 1 mA)
Mechanical Bandwidthtypical 500 Hz
Transducer Power Supply Currentmax 30 mA
Power Supply Rejection Ratio(gain+offset) max 0.04% / V of the end of scale (voltage: -+ 15V)
Output Ripple AF Spike Excludedmax 10 mV for voltage output (20 micro A rms for current output for the 1 channel version;
Current Output Signal4/20 mA (load impedance max. 250 ohm, min. 100ohm)
Protection Degree(with connectors plugged in) IP54
Operating Relative Humidity(not condensing) 20% - 80%
Storing Relative Humidity10% - 95%
Channels(1, 4, 8) Number
Storing Temperature-25 Degree /+ 75 Degree C
Weight0,8 kg
Type Of Transducer(LVDT/HBT)

Product Description

TCI is a line of signal conditioning interfaces consisting of three models with either one, four or eight channels.

It has been developed with technical and functional specifications particularly suited to convert a position or a dimensional measurement, performed by LVDT or HBT transducers, in a signal compatible with most of the analogue data acquisition cards. The unit output provides a direct electric signal (voltage or current), proportional to the measurement value of the sensor connected in input.

The output signal can be acquired by PLC analogue cards to control and manage process automations and for further processing by SCADA supervision systems.

The TCI interfaces are PLUG&PLAY units and therefore are supplied already calibrated for the model of sensor being used. This ensures that the machine down times are drastically reduced as the installation and maintenance operations are simplified.

Features

  • easy to install as it is calibrated during the production based on the model of sensor being used
  • compatible with most of the sensors available on the market
  • highly customisable
  • reliable and sturdy
  • one channel
  • four channels
  • eight channels

Interested in this product?Get Latest Price from the seller
Contact Seller

About the Company

Year of Establishment1952
Legal Status of FirmLimited Company (Ltd./Pvt.Ltd.)
Nature of BusinessManufacturer
Number of Employees1001 To 2000 People
Annual TurnoverRs. 100 - 500 Crore
IndiaMART Member SinceDec 2011
GST06AAFCM1601B1ZA
Inspection, measurement and process control solutions include gauges and compensation systems for grinders and other machine tools; manual gauges, sensors, probes and other gauge components; automatic and semi-automatic measurement and inspection systems; leak test and assembly solutions; hardware and software for data collection and process analysis; equipment for non-destructive testing