RTPFC Panels

₹ 6,500/ PieceGet Latest Price
Usage/Application
Chemical Industry, Cement Plant, Sugar Plant, Textile, Hospital, Automatic
Rated Reactive Power
5kVAR-4000kVAR
Capacity
5kW-4000kW
Phase Type
Three Phase
Condition
New
RTPFC panel is an integration of CRCA powder coated MS Sheet enclosure , fully wired with Self healing MPP capacitor & Reactor , capacitor duty Thyristor, fan, APFCR, all switchgears, with IP protection , busbar AL/CU, with IEC STD, a) The thyristor switched contactor shall be capable of handling the continuous current of 130% of the rated capacitor current at rated voltage of 415V. The blocking voltage of the thyristor switch during off Condition should be minimum 1800 Volt peak. Every thyristor switch should be capable of handling the dv/dt of 2000 Volts/ S. b) The thyristor switched contactor used shall turn on at zero differential voltage across it. This zero differential voltage tolerance shall not exceed 6 Volts peak value around zero. c) The time delay between turn off and subsequent turn on should be as minimum as possible and in the range of milliseconds. There should not be any discharge devices across capacitor that can exceed the watt loss of more than 30 watt.
View Complete Details
Get Latest PriceRequest a quote

Accu-Panels Energy Private Limited

Odhav, Ahmedabad, Gujarat
4.3/5 
★★★★★
★★★★★
 (11)
GST24AAOCA0780G1ZR
Verified Plus Supplier
Manufacturer
View Mobile Number
83% Response Rate
Contact Supplier

Product Details

Company Details

Product Specification

Usage/ApplicationChemical Industry, Cement Plant, Sugar Plant, Textile, Hospital, Automatic
Rated Reactive Power5kVAR-4000kVAR
Capacity5kW-4000kW
Phase TypeThree Phase
ConditionNew
Voltage415V-525Vac
Thickness2-3 mm
Minimum Order Quantity 1 Piece

Product Description

RTPFC panel is an integration of CRCA powder coated MS Sheet enclosure , fully wired with Self healing MPP capacitor & Reactor , capacitor duty Thyristor, fan,APFCR, all switchgears, with IP protection , busbar AL/CU, with IEC STD, a) The thyristor switched contactor shall be capable of handling the continuous current of 130% of the rated capacitor current at rated voltage of 415V. The blocking voltage of the thyristor switch during off Condition should be minimum 1800 Volt peak. Every thyristor switch should be capable of handling the dv/dt of 2000 Volts/ S. b) The thyristor switched contactor used shall turn on at zero differential voltage across it. This zero differential voltage tolerance shall not exceed 6 Volts peak value around zero. c) The time delay between turn off and subsequent turn on should be as minimum as possible and in the range of milliseconds. There should not be any discharge devices across capacitor that can exceed the watt loss of more than 30 watt.

Additional Information

Item Code RTPFCPanel
Delivery Time 15 days
Production Capacity 1-500
Packaging Details Wooden and corrugated plastic
Interested in this product?Get Latest Price from the seller
Contact Seller

About the Company

Year of Establishment2015
Legal Status of FirmLimited Company (Ltd./Pvt.Ltd.)
Nature of BusinessManufacturer
Number of Employees11 To 25 People
Annual TurnoverRs. 5 - 10 Crore
IndiaMART Member SinceSept 2010
GST24AAOCA0780G1ZR
Import Export Code (IEC)AAOCA*****

We at ACCU-PANEL ENERGY PRIVATE LIMITED that what is best for our customer is best for our company. We put Quality first in every decision which we take. We are committed to serve our customers with honesty and transparency. Operating from Ahmadabad, Gujarat India), we Accu-Panels Energy Private Limited, have been offering high quality advanced Electrical Control Panels since 2009. As a renowned player in the industry, we have taken care of overall infrastructural facility and therefore we have created high-end production unit along with quality control unit and a few other inspection stage. Due to our proper segregation of manufacturing works, we can stress on each individual aspect of the accurate products. Moreover, all the manufacturing stage are finely coordinated with each other for streamline functioning. Our quality consciousness keeps us in tab with recent happenings with quality standards.

Accu-Panels is the Prominent and Well-known Panel Manufacturer of LT Electrical Power & Control Panels.We Offering All type LT Panels, Solar Products ACDB DCDB, Motor Control Centre Panel (MCC), Intelligent MCC Panel (IMCC), Change over Panel, Power control Panel (PCC) , Automatic Power Factor Correction Panel (APFC), Bus duct up to 6500A Aluminium & Copper, Auto transfer Switch Panel (ATS), Junction Boxes, Feeder Pillar, Distribution Board, Lighting Distribution Panel, Fully Auto and Manual Dg Synchronizing Panel, PLC based Motor Control Centre, Automatic Mains Failure Control Panel (AMF), AC Drive and Soft Starter Control Panel, DOL Starter Panel, Star-delta Starter Control Panel, Customized & Challenging Design as per requirements.

Accu-Panels have developed new products of ACDB DCDB, Feeder Pillar & Junction Box, APFC Panel, MCC Panel, PCC Panel, AMF Panel, Solar Synchronizing Panel, IMCC panel, Lightning Distribution Board Etc. we are supplying to all Ministry of New and Renewable Energy (MNRE) and Gujarat Energy Development Agency (GEDA) approved Solar Product and leading Providers with best Quality and Services

We are manufacturing and supplying a wide range of Electrical Control Panels, some of which are named below:

· ACDB (AC DISTRIBUTION BOARD)

· DCDB (DC DISTRIBUTION BOARD)

· SOLAR ACDB CUM DCDB

· FEEDER PILLERS

· JUNCTION BOXES

· AC COMBINER BOX

· PCC (POWER CONTROL CENTER)

· MCC (MOTOR CONTROL CENTER)

· APFCR PANEL IMCC (INTELLIGENT MCC PANEL)

· VFD AND SOF STARTERS PANEL

· SYNCHRONIZING PANEL

· AUTO CHANGEOVER

· AMF PANEL

· BUSDUCT Up To 6300A

· PLC SCADA AND AUTOMATION PANEL

· ALL TYPE STARTERS PANEL

· LIGHTING & POWER DISTRIBUTION BOARD

RTPFC Panels
RTPFC Panels
termsprivacy policy

Seller Contact Details

Ritesh Jani

Plot No. 303, Road No. 4 A, Odhav Ahmedabad - 382430, Gujarat, India

Get Directions
View Mobile No.
Send SMS
Send Email