Accuracy | +- 2.5% to 3% of actual reading |
Keeping in mind ever-evolving requirements of our respected clients, we are providing a premium quality range of Steam Flow Meter.
Introduction:
- The SFMc-150 flow meter is applicable for measuring flow rates of saturated and superheated steam, mass flow rates of Boiler feed Water in closed conduits.
- It is best suited for applications where affordability, reliability and ruggedness are of prime concerns.
* It can be used as heat energy transfer meter to measure thermal energy using various fluids which are being used as the heat transfer medium.
* In the conventional system of measurement, the differential pressure generated by orifice plate is measured by DP transmitter.
* The output from DP transmitter after square rooting is accepted as proportional to flow rate.
* This assumption is true only when the density is constant. Unfortunately, the density of the compressible fluid is never constant.
* The density of compressible fluid changes with line pressure and line temperature.
* Thus, introducing errors in flow rate measurement.
Other Details
* Designed as per ISO5167/BS1042.
* On line density compensation delivers very accurate results.
* Various Types of IBR/Non-IBR valves for isolation and drain.
* Various Sizes of Orifice Assemblies with or without IBR Certificate.
* Complete System is Engineered to suit your requirements.
* Highly Reliable and Repeatable System; No Moving Parts.
* Easy for Calibration.
Features of Steam Flow Meter
* Easy user-friendly programming.
* Password protected for all modes except display mode
* Computer/Printer Interfacing with RS 232/RS 485 port with MODBUS RTU
* Fault indication indicated by different error codes
* Overflow indicated by blinking display up to 3000 readings (for more readings consult factory)
* Data logging facility with 3450/ 6900 number of reading is available
* Linear or square root operation
* Universal power supply
* Suitable for Saturated &/or Superheated Steam
* Two-alarm setting configured on pressure input
* Steam status indication (Saturated/ Superheated)
* Pressure and temperature offsets generated by site condition can be compensated
* Mass flow calculation as per ASME algorithm
Introduction:
- The SFMc-150 flow meter is applicable for measuring flow rates of saturated and superheated steam, mass flow rates of Boiler feed Water in closed conduits.
- It is best suited for applications where affordability, reliability and ruggedness are of prime concerns.
* It can be used as heat energy transfer meter to measure thermal energy using various fluids which are being used as the heat transfer medium.
* In the conventional system of measurement, the differential pressure generated by orifice plate is measured by DP transmitter.
* The output from DP transmitter after square rooting is accepted as proportional to flow rate.
* This assumption is true only when the density is constant. Unfortunately, the density of the compressible fluid is never constant.
* The density of compressible fluid changes with line pressure and line temperature.
* Thus, introducing errors in flow rate measurement.
Other Details
* Designed as per ISO5167/BS1042.
* On line density compensation delivers very accurate results.
* Various Types of IBR/Non-IBR valves for isolation and drain.
* Various Sizes of Orifice Assemblies with or without IBR Certificate.
* Complete System is Engineered to suit your requirements.
* Highly Reliable and Repeatable System; No Moving Parts.
* Easy for Calibration.
Features of Steam Flow Meter
* Easy user-friendly programming.
* Password protected for all modes except display mode
* Computer/Printer Interfacing with RS 232/RS 485 port with MODBUS RTU
* Fault indication indicated by different error codes
* Overflow indicated by blinking display up to 3000 readings (for more readings consult factory)
* Data logging facility with 3450/ 6900 number of reading is available
* Linear or square root operation
* Universal power supply
* Suitable for Saturated &/or Superheated Steam
* Two-alarm setting configured on pressure input
* Steam status indication (Saturated/ Superheated)
* Pressure and temperature offsets generated by site condition can be compensated
* Mass flow calculation as per ASME algorithm
View Complete Details
Get Latest PriceRequest a quote
Verified Supplier
Manufacturer
View Mobile Number
30% Response RateContact Supplier
Product Details
Company Details
Product Specification
Display | Digital |
Packaging Type | Box |
Power Supply | 85 to 265 V AC @ 50 Hz |
Model Name/Number | SFMc-150 |
Accuracy | +- 2.5% to 3% of actual reading |
Brand | Manas |
Temperature | Upto 600 deg C |
Comm Protocol | MODBUS, RTU |
Comm Port | RS485, RS232 (Optional) |
Type of Flow Element | Orifice type |
Typical Turndown | 103 (Std), 101 (Contact to factory) |
Orifice Flange Assembly | WNRF class 300 |
Service | Saturated and superheated steam, Hot water, thermic fluids in closed pipes |
MOC of Flow Element | SS 316 |
End Connection | Sorf flange |
Pressure | 22 kg/cm2 Max |
Density Compensation | Online monitoring and compensation of density |
Size | 1" to 10" inch |
MOC of Flanges | MS/CS/SS |
DPT | With display |
Data Logging | 3450 readings or 6900 readings (Optional) |
Product Description
Keeping in mind ever-evolving requirements of our respected clients, we are providing a premium quality range of Steam Flow Meter.
Introduction:
Introduction:
- The SFMc-150 flow meter is applicable for measuring flow rates of saturated and superheated steam, mass flow rates of Boiler feed Water in closed conduits.
- It is best suited for applications where affordability, reliability and ruggedness are of prime concerns.
- It can be used as heat energy transfer meter to measure thermal energy using various fluids which are being used as the heat transfer medium.
- In the conventional system of measurement, the differential pressure generated by orifice plate is measured by DP transmitter.
- The output from DP transmitter after square rooting is accepted as proportional to flow rate.
- This assumption is true only when the density is constant. Unfortunately, the density of the compressible fluid is never constant.
- The density of compressible fluid changes with line pressure and line temperature.
- Thus, introducing errors in flow rate measurement.
- Designed as per ISO5167/BS1042.
- On line density compensation delivers very accurate results.
- Various Types of IBR/Non-IBR valves for isolation and drain.
- Various Sizes of Orifice Assemblies with or without IBR Certificate.
- Complete System is Engineered to suit your requirements.
- Highly Reliable and Repeatable System; No Moving Parts.
- Easy for Calibration.
- Easy user-friendly programming.
- Password protected for all modes except display mode
- Computer/Printer Interfacing with RS 232/RS 485 port with MODBUS RTU
- Fault indication indicated by different error codes
- Overflow indicated by blinking display up to 3000 readings (for more readings consult factory)
- Data logging facility with 3450/ 6900 number of reading is available
- Linear or square root operation
- Universal power supply
- Suitable for Saturated &/or Superheated Steam
- Two-alarm setting configured on pressure input
- Steam status indication (Saturated/ Superheated)
- Pressure and temperature offsets generated by site condition can be compensated
- Mass flow calculation as per ASME algorithm
Interested in this product?Get Latest Price from the seller
Contact Seller
About the Company
Year of Establishment2019
Legal Status of FirmLimited Company (Ltd./Pvt.Ltd.)
Nature of BusinessManufacturer
Number of EmployeesUpto 10 People
Annual TurnoverUpto Rs. 50 Lakh
IndiaMART Member SinceMar 2015
GST33AABCY1002A1ZC
Import Export Code (IEC)AABCY*****
Seller Contact Details
Rajkumar Jeyaraman
214, Vijay Nagar, Varadharajapuram Village, Sriperumbudur Taluk, Chennai - 600048, Tamil Nadu, India
Get DirectionsView Mobile No.
Send SMS
Send Email