AC And DC High Voltage Tester
| Model Name/Number | ACDC |
| Usage/Application | Industrial |
| Brand | RE |
| Voltage | 220/230V or 380/400V,50 or 60HZ AC supply |
| Power Supply | 220/230V or 380/400V,50 or 60HZ AC supply |
| Dimension | Depends upon the Rating of the Instrument |
- Above Price of 39000/- is for low range pf 5kV ACDC and 100mA AC and 10mA for DC.
- We manufacture up to 300kV ACDC with 100mA for AC and 50mA for DC.
- Price varies as the capacity varies.
Description
AC/DC High Voltage test sets are specially designed for application where both AC as well as DC is required for testing. These test sets are specially designed for capacitor testing. During manufacturing each unit is tested at multiple stages, thus ensuring consistency and best quality. These instruments are air cooled, oil cooled or air & oil cooled combined as per design. The units have been designed and manufactured up to 300kV.
Technical Specifications
| ACDC Combined High Voltage Test Set | ||
| Sr. No. | Parameters | Description |
| 1 | I/p Voltage | 220/230V or 380/400V, 50 or 60HZ AC supply |
| 2 | O/p Voltage | Up 300KV |
| 3 | Leakage Current | Up to 100mA AC and 50mA in DC |
| 4 | Timer | 0-9999 Sec./min. Digital |
| 5 | Control | Type 1- The unit can be manual/motorized control for voltage variation and push button controlled for HT actuation. Type 2- The unit can be complete with on board digitized panel with or without computer connectivity. Type 3- The unit can be PLC based complete with computer, HMI memory, printer etc. for operation. |
| 6 | Protection | Tripping - A fast acting DC relay will isolate the circuit when the current exceeds pre-set level. Overload - This is used as a secondary protection in case the input loads exceeds the preset value Overvoltage - This is used as a secondary protection in case the output voltage exceeds the preset value |
| 7 | Interlocking | Zero Start Interlock - The unit will have zero start interlocking to avoid the transients on HV transformer and provision for cage door interlocking shall also be provided. Earth interlock- It ensures that HV will not actutae untill good earthing is not provided. |
| 8 | Termination | The HT output on suitable HT insulator and other point at earth potential will be brought out on suitable insulator |
| 9 | Control Panel | The control panel is designed for five unique purposes. 1 -Control 2- Measure 3- Protect (Active and Passive) 4- Tripping 5 -Annunciate |
| 10 | HV Transformer | The transformers are designed and manufactured as per IS /IEC guidelines. Single / Multiple stage stepup transformers are utilized for achiving the desired voltage. The units are designed and manufactured using the preeminent material from India and Abroad. The coils are vacuum impregnated and insulated with High Quality EHV Grade transformer oil as per relevant IS and IEC Standard. |