X

Reliable Power Systems

Ankleshwar, Gujarat

| GST  24BCTPK7920B1ZM

| Verified Supplier

View Mobile Number 84% Response Rate
Hi
I agree to the terms and privacy policy
Verifying...
1

Have a requirement?
Get Best Price

Eapl Timer, Motor Protection Device & Controller

Our range of products include Timer IC, Digital Timer, Motor Protection Device, Temperature Controller, Power Supply and Cyclic Timer.

Timer IC
Interested in this product?
Get Best Quote

Timer IC

Rs 1 / NumberGet Latest Price

Minimum Order Quantity: 1 Number

Product Features: 
  • Din sized enclosure for Track (Din rail) / Screw mounting.
  • Front terminal protective cover for safety.
  • LED indication for timing in progress.
  • A1DA :External (zero volt / potential free) command contact for timing initiation.
Dimensions: Over-all: 22.5 X 75 X 102mm (W X H X D).Applications: AMF panels, Automation panels, HT / LT panels, MCC panels, C & R panels, RTCC panels, Transformer panels and many more

View Complete Details

Yes, I am interested!

Digital Timer
Interested in this product?
Get Best Quote

Digital Timer

Get Latest Price

Minimum Order Quantity: 1 Number

Product Features: 
  • Din Sized enclosuer for panel mounting.
  • Digital dual display for set value and process value.
  • FUNCTION (programmable): ON DELAY / INTERVAL /CYCLIC ADJUSTABLE.
  • TYPE OF START SIGNAL (programable) : NO START / PULSE / CONTINUOUS.
  • One of the relay c/o can be configured as INSTANT or DELAYED.
  • Program lock is provided for function, relay configuration, type of start signal and range selected.
  • RESET cum START facility can be achieved either through front buttons Or Rear terminals
  • HOLD/RESTART facility during power failure conditions.
  • Internal Resettable fuse for protection of device against voltage fluctuations(N.A. for H3PT-MU). Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal
Dimensions: Over-all: H3PT-MU – 48 x 48 x 115mm, C3PT-MU, CD6 - 72 x 72 x 128mm, E3PT-MU – 96 x 96 x 117mm (W x H X D)Cut-out: H3PT-MU – 46 x 46 mm, C3PT-MU, CD6 - 69 x 69mm, E3PT-MU – 92 x 92mm (W x H)Applications: Injection moulding machine panels, Granite processing machines, Packaging / Printing machines, Hot stamping machines etc

View Complete Details

Yes, I am interested!

Motor Protection Device
Interested in this product?
Get Best Quote

Motor Protection Device

Rs 1 / NumberGet Latest Price

Minimum Order Quantity: 1 Number

Product Features: 
  • Front button for resetting in manual mode
  • External potential free (zero volt /no voltage) terminal contacts for auto mode.
  • LED indication for relay status
  • Window displays the type of fault that has occurred during unhealthy condition
  • Trip delay time and limits for each parameter can be set digitally
  • All programs can be locked by removing short link across specified terminals
  • Unwanted parameters can be by-passed as per user's choice.
  • Relay can be configured to have NO or NC status during healthy condition
  • Unit will retain fault till accepted in manual mode
  • PVMD, PVMD-G : Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage or over voltage) occurs.
  • Displays all the 3 phase voltages in a scrolling fashion during healthy condition.
  • PVMD – Panel / Flush mounting, PVMD-G Din Rail mounting
  • PVIMD, PVIMD-G : Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage, over voltage, under current or over current)
  • Displays all the 3 phase voltages and 3 phase currents in a scrolling fashion during healthy condition.
  • User can program nominal current. Under current and over current limits can be set in percentage with reference to nominal current.
  • User can set the in-rush time delay.
  • Terminals to connect all the 3 phase CTs are provided.
  • CT primary can be programmed up to 2500 in steps of 5. CT secondary will be factory set for 5.
  • PVIMD – Panel / Flush mounting. PVIMD-G - Din Rail mounting
  • Din sized enclosure with Auto / manual Switch
Dimensions: Overall: PVMD, PVIMD– 96 x 96 x 97.5mm, PVMD-G, PVIMD-G,– 76 x 78 x 115mm (W x H x D) Cut-out: PVMD, PVIMD– 92 x 92mm (W x H)Applications: Any 3 phase 4wire systems like Motors, pumps, generators, Distribution panels, MCC, air conditioners, elevators, cranes, escalators, etc

View Complete Details

Yes, I am interested!

Temperature Controller
Interested in this product?
Get Best Quote

Temperature Controller

Get Latest Price

Minimum Order Quantity: 1 Number

Product Features: 
  • Universal Input (J,K,PT-100) Selectable.
  • Wide Voltage Range.
  • ON / OFF or Self-Tuned Function Selectable.
  • Single / double set point.
  • Over Voltage Protection
  • Compensation offset feature available in TX7-Ua User Friendly Programming through increment / decrement button (TX7-ua)
  • Indication for sensor, funtion and relay status.
  • Program enable / disable for sensor, function, hystersis, compensation features in TX7-Ua. Dimension 72x72x128.5
Dimensions: Overall: H3-TX Models -48 x 48 x 115mm, TX7 Models- 72 X 72 X 128mm; EX9 Models- 96 x 96 x 117mm (W x H X D)Cut-out: H3-TX Models – 46 x 46mm, TX7 Models - 69 x 69mm , EX9 Models – 92 x 92mm (W x H)

View Complete Details

Yes, I am interested!

Power Supply
Interested in this product?
Get Best Quote

Power Supply

Get Latest Price

Minimum Order Quantity: 1 Number

Product Features: 
  • Compact, light weight and SMPS design
  • Versatile and easy snap-on mounting on Din-rail
  • Very low ripple and noise
  • Regulated and adjusted output
  • Protection against over voltage, short circuit and over load
Dimensions: Overall: MS-01 - 45 x 75 x 116mm, MS-02 – 110 x 86 x 71mm , MS-03 - 155 x 88 x 79mm, MS-04 - 172x150x78mm MS-05 – 22.5 x 75 x 97mm (W x H x D) Applications: PLC, DC Panels, DC Solenoids, DC Relay boards, Battery Charging Panels, etc.

View Complete Details

Yes, I am interested!

Cyclic Timer
Interested in this product?
Get Best Quote

Cyclic Timer

Get Latest Price

Minimum Order Quantity: 1 Number

  • Din sized enclosure for Track (Din rail) / Screw mounting.
  • B1DCA-T : HOLD / RESTART facility during power fail conditions.
  • B1DCA-T : Auto / Manual switch for mode of operation
  • B1DCA-T : Program - enable / disable facility for tamper proof operation.
  • B1DCA-X, B1DCA-T : Independently selectable ON & OFF time.
  • SPP-T :Trips under phase missing, phase reversal or phase unbalance
  • In manual mode, terminals provided to connect to switch so as to manually switch ON and switch OFF load
Dimensions: Over-all: 45 X 75 X 116mm (W X H X D).Applications: Lubricating system, DG Sets, MCC panels, Pump panels and many more...

View Complete Details

Yes, I am interested!
Tell us what you
need
Receive seller
details
Seal the deal
Save time! Get Best Deal
I agree to the terms and privacy policy