Our Product Range
- Flow Through Orifice and Mouthpiece
- Pitot Tube Setup
- DISCHARGE OVER NOTCHES APPARATUS
- Impact Of Jet On Vanes
- Cavitation Apparatus
- Bernoulli''S Theorem Apparatus
- Discharge Through Venturimeter
- Reynold Apparatus
- Centre Of Pressure Apparatus
- Free Vortex Apparatus
- Free & Forced Vortex Apparatus
- Pipe Fitting Apparatus
Fluid Mechanics Lab

Brand | Reliant lab |
Automation Type | Semi-Automatic |
Sump Tank | 25 LTRS |
Capacity | 70 LTRS |
Material | Stainless Steel |
Water Handling | 0.5 HP PUMP,Crompton Make |
It consists of a tank provided with inlet supply diffuser, overflow, and provision for fitting Orifice or Mouthpiece at the outlet of tank. An arrangement is done to vary head and keep it constant at desired level. A pointer gauge arrangement for measuring X-Y co-ordinates of Jet is also fitted. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow rate of water is measured with the help of measuring tank and stop watch.
Additional Information:
- Item Code: RLFM-104
- Delivery Time: 8 DAYS
View Complete Details

Pitot Tube Setup
Rs 40,000 / PieceGet Latest Price
Brand | Reliant Lab |
Usage/Application | Lab Experiments |
Material | Stainless Steel |
Phase | Single Phase |
Model Name/Number | RLFM-114 |
A Pitot Tube is used to measure the local velocity at a given point in the flow stream. A pitot tube of standard design made of copper/SS is supplied and is fixed below vernier scale. The vernier scale is capable to measure the position of Pitot Tube in transparent section. The pipe has a flow control valve to regulate the flow. An differential water manometer is provided to determine the velocity head. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch
View Complete Details

Brand | Reliant Lab |
Model | RLFM-103 |
Material | Stainless Steel |
Usage/Application | EXPERIMENTAL |
Capacity | 70 LTRS |
Operating Voltage | 220v |
The Lab setup consists of a channel having sufficient length and width in which water is supplied from the bottom. Required Notch is fitted at one end of this channel .A hook gauge with Vernier scales fitted to measure the height of fluid in flow channel. Arrangement for fixing interchangeable notches is made. Set of three brass notches. i.e. rectangular notch . 60V notch & 45V notch provided along with the set up. Present set up is self contained water re·circulating unit provided with a sump tank and centrifugal pump Etc Flow control valve and by· pass value are fitted in water line to conduct the experiment on different flow rate, Flow rate of water is measured with the help of measuring tank and stopwatch
Additional Information:
- Item Code: RLFM-103
- Delivery Time: 8 DAYS
View Complete Details

Impact Of Jet On Vanes
Rs 35,000 / PieceGet Latest Price
Brand | Reliant Lab |
Usage/Application | For Lab Experiments |
Material | Stainless Steel |
Phase | Single Phase |
Model Name/Number | RLFM-106 |
Features | Flow Measurement : Using Measuring Tank with Piezometer |
The setup consists of a clear Acrylic fabrication section. Water is fed through a nozzle and discharged vertically to strike a target carried on a stem, which extends through the cover. A weight carrier is mounted on the upper end of the stem. The dead weight of the moving parts is counter balanced by a compression spring. The vertical force exerted on the target plate is measured for applied weights. Two targets are provided with the setup (flat plate and hemispherical cup).
View Complete Details

Cavitation Apparatus
Rs 42,000 / PieceGet Latest Price
Material | SS |
Test Section | Acrylic |
Water Circulation | By Pump |
Pressure Gauge | 0-4kg/cm2 |
Sump Tank | 60 LTRS |
The apparatus has been designed to demonstrate the phenomenon of cavitation. The present set-up consists of a test section made of Acrylic having conversion and diversion section. Pressure tapings at appropriate position are provided. This test section is having one control valve at upstream side to regulate the water flow rate. Two pressure gauges are connected to these taping which give the pressure readout at the time of flow passing through this test section. The unit is self-contained close circuit type with sump tank, measuring tank and centrifugal pump. Flow through test section can be regulated with the help provided by-pass and control valve.
Additional Information:
- Item Code: RLFM-117
- Delivery Time: 8 days
View Complete Details

Brand | Reliant lab |
Model | RLFM-102 |
Automation Type | Semi-Automatic |
Usage/Application | EXPERIMENTAL |
Capacity | 70 LTRS |
Material | Stainless Steel |
Stop Watch | Electronic |
Water Circulation | 0.5 Hp Pump,Crompton make |
The equipment is designed and fabricated to demonstrate the Bernoulli's theorem. It consists of a test section made of acrylic. It has convergent and divergent sections. Pressure tapings are provided at different locations in convergent and divergent section. Present set-up is self-contained water re-circulating unit, provided with a sump tank, centrifugal pump etc. An arrangement is done to conduct the experiment on different flow rates. Flow rate of water is measured with the help of Measuring tank and stopwatch.
Additional Information:
- Item Code: RLFM-102
- Delivery Time: 8 DAYS
View Complete Details

Usage/Application | Lab Experiments |
Type Of Instruments | Educational |
Material | Stainless Steel |
Color | White |
Model Name/Number | RLFM-110 |
Capacity | 50 LTRS |
Phase | SINGLE |
The apparatus consists of a pipe line contains one Veturimeter. Veturimeter is made from clear Acrylic. The pressure tapings from the Veturimeter is taken to differential manometer to measure pressure difference. A valve is provided at the downstream side of Veturimeter. The flow can be regulated by this valve. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.
Additional Information:
- Delivery Time: 7 DAYS
View Complete Details

Phase | Single Phase |
Brand | Reliant lab |
Voltage | 220VAC |
Frequency | 50Hz |
Current | 5-15 amp |
Chemical Required | Dye ( KMno4) -10gm |
Floor Area Required | 1.5mx0.75m |
With an objective to fulfill the ever-evolving demands of our clients, we are engaged in offering a wide assortment of Reynold Apparatus.
The Apparatus consists of galss tu e with one end having bell mouth entrance, Connected to a constant head water tank at the other end a vlave is provided to very the flow rate the tank is of sufficient capacity to store water. A Capillary tube is introduced centrally in the bell mouth for feeding dye from a small container placed at the top of tank, through polythene tubing. By varying the rate of flow, the Reynolds''s number is changed this also changes the type of flow visual oservation of dye ( Thread) Will indicate the type of flow, Which cna be confirmed from the Reynold''s Number computed. Present set up is self contained water re circulating unit provided with a sump tank and a centrifugal pump etc. Flow control valve and by pass valve are fitted in water line. Flow rate of water is measured with the help of measuring cylinder and stop watch.
Experimentation:
- To determine the Reynold''s number and hence the Type of flow either laminar or Turbulent .
- To study transition zone.
Utilities Required.
- Electricity supply: combined socket with earth connection. Earth voltage should be less than 5 volts.
- Water Supply ( Intial Fill)
- Floor drain required.
Technical Details:
- Tube : Material Borosilicate Glass ( ID 14mm approx Length :600mm)
- Dye Vessel: Material Stainless Steel , Capacity 1Ltrs ( approx)
- Capillary Tube : Material copper / Stainless Steel
- Constant Head Water Tank: Capacity 40 Ltrs
- Water Circulation: 1/2 HP Pump, Champion/ Standard Make
- Flow Measurement : Using measuring cylinder with electronic stop watch
- Sump Tank : Capacity 60 Ltrs
- Control Panel Comprises Of : Standard make on/off switch mains indicator,etc.
- Tanks will be mad of stainless steel
- An English instruction manual consisting of experimental procedures block diagram etc. Will be provided along with the Apparatus.
- The Whole Set up is well designed and arranged on a rigid structure painted with industrial PU Paint.
Additional Information:
- Item Code: RLFM101
- Delivery Time: 10 days
View Complete Details

Model | RLFM-116 |
Brand | Reliant Lab |
The Centre of Pressure Apparatus has been designed to determine the static thrust exerted by a fluid on a submerged surface and allow comparison of the measured magnitude and position of this force with simple theory.
Additional Information:
- Item Code: RLFM-116
- Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
- Delivery Time: 8 DAYS
View Complete Details

Country of Origin | Made in India |
Brand | Reliant Lab |
Material | Stainless Steel |
Application | Laboratory |
Power Source | Electric Motor |
Flow Measurement | Using Rotameter. |
Riding on unfathomable volumes of industrial expertise, we are providing a broad array of Free Vortex Apparatus.
Other Details:
The experimental set up consist of a circular transparent cylindrical tank in which four circumferential jets are placed along the circumference of the cylinder near its bottom which helps in the formation of free vortex. It is assumed that the torque exerted by these jets is negligible. A pointer can be transversed horizontally & vertically across full diameter of the vessel so that water surface profile can be measure. Both axes contain graduations so that exact position of the pointer is known. The experimental procedure involves measurement of the resulting free surface that represents the variation of the sum of the pressure head and datum head. An arrangement is provided to drain the vessel.
Experimentation-To plot the surface profile of a free vortex by measurement of the surface profile coordinates and to show that total energy is constant throughout vortex.
Additional Information:
- Item Code: RLFM-118
- Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
View Complete Details

Brand | Reliant Lab |
Material | Stainless Steel |
Backed by rich industry experience and market understanding, we are involved in offering a wide array of Free & Forced Vortex Apparatus to our valued patrons.
Other Details:
The free vortex experimental set up consist of a circular transparent cylindrical tank in which four circumferential jets are placed along the circumference of the cylinder near its bottom which helps in the formation of free vortex. It is assumed that the torque exerted by these jets is negligible. A pointer can be transversed horizontally & vertically across full diameter of the vessel so that water surface profile can be measure.
Both axes contain graduations so that exact position of the pointer is known. The experimental procedure involves measurement of the resulting free surface that represents the variation of the sum of the pressure head and datum head. An arrangement is provided to drain the vessel.
The forced vortex experimental set up consist of a circular transparent cylindrical tank in which plate is rotated with the help of a variable speed motor so that the cylinder rotates about its vertical axis with the help of a V belt and forced vortex is formed. An upper probe can be transversed horizontally & vertically across full diameter of the vessel so that water surface profile can be measure. Both axes contain graduations so that exact position of the probe is known. The experimental procedure involves measurement of the resulting free surface that represents the variation of the sum of the pressure head and datum head. An arrangement is provided to drain the vessel
Additional Information:
- Item Code: RLFM-119
- Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
View Complete Details

Pipe Fitting Apparatus
Rs 42,000 / PieceGet Latest Price
Brand | Reliant Lab |
Voltage | 220V AC |
Phase | Single Phase |
Power | 0.5 kW |
Pitot Tube Material | Copper/SS of compatible size |
Hook Pointer Gauge | With Vernier Scale |
Test Section | Material Clear Acrylic, compatible |
Features:
The set up consists of a ½” bend and elbow, a sudden expansion & sudden contraction
fitting from 15mm to 25mm, ball valve and gate valve. Pressure tapings are provided at
inlet and outlet of these fittings under test. A differential manometer fitted in the line
gives pressure loss of individual fittings. Present set-up is self-contained water re-circulating
unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pas
s valve are fitted in water line to conduct the experiment on different flow rates.
Flow rate of water is measured with the help of measuring tank and stop watch.
Additional Information:
- Item Code: RLFM-107
- Pay Mode Terms: T/T (Bank Transfer),Other
View Complete Details
- Developed and Managed by IndiaMART InterMESH Limited