Our Product Range
- Stefan Boltzman''s Apparatus
- Heat Transfer Through Composite Wall
- Heat Transfer Through Lagged Pipe
- Parallel Flow Counter Flow Heat Exchanger
- Two Phase Heat Transfer Unit
- Heat Transfer Apparatus
- Shell and Tube Heat Exchanger
- Helical Coil Heat Exchanger
- Heat Transfer In Natural Convection
- Pool Boiling Apparatus
Heat Transfer Lab
Heat Transfer Lab Equipments, Heat Transfer Equipments Suppliers, Heat Transfer Lab Instruments India, Heat Transfer Lab Equipments Manufacturers, Heat Transfer Lab Equipments Exporters India, Heat Transfer Labs Equipments, Reliant Lab
| Country of Origin | Made in India |
| Application | Laboratory |
| Temperature Range | 5700 K |
| Base Material | Mild Steel |
| Current | 10 Amp |
| Hemisphere | 200mm |
We are successfully meeting the varied needs of our patrons by offering a wide gamut of Stefan Boltzman's Apparatus as per their precise needs.
Other Details:
The apparatus is designed to determine the Stefan Boltzmann constant.
The apparatus consists of a hemisphere fixed to a Bakelite plate, the outer
surface of which forms the jacket to heat it.
Hot water to heat the hemisphere is obtained form a hot water tank, which
is fixed above the hemisphere. The copper test disc is introduced at the
center of hemisphere. The temperatures of hemisphere and test disc are
measured with the help of temperature sensors.
Additional Information:
- Item Code: RLHT115
- Pay Mode Terms: T/T (Bank Transfer),Other
View Complete Details
| Flow Type | Parallel Flow |
| Usage/Application | For Pharma Industry |
| Medium Used | Air |
| Automation Grade | Semi Automatic |
| Brand | Reliant Lab |
| Current | 2 Amp |
The setup consists of a heater sandwiched between two
sets of slabs. Three types of slabs are provided on either
sides of heater, which forms a composite structure. A
small hand press frame is provided to ensure the perfect
contact between the slabs. A PID Controller is provided
for controlling the heat input. Electronic energymeter will
be provided to measure the heat input. Heat produced by
heater flows axially on both the sides. Temperature Sensors are embedded at the interfaces of slabs to
determine the temperature gradient. The experiment can be conducted at various values of heat input and
calculation can be made accordingly.
Additional Information:
- Item Code: RLHT-101
- Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),Other
- Delivery Time: 8 DAYS
View Complete Details
| Power Source | Electric |
| Voltage | 220-440V |
| Frequency | 50-60Hz |
| Material | Mild Steel |
| Finish | Paint Coated |
| Automation Grade | Automatic |
With the valuable assistance of skilled team of professionals, we are engaged in offering an extensive range of high-quality Heat Transfer Through Lagged Pipe.
Other Details:
The setup is designed and fabricated to study lagging phenomenon in case of pipes. It consists of three concentric pipes of small thickness as compared to diameter and are arranged concentrically, and closed with the help of two discs. Two different insulating materials fill the annuli between the cylinders. Temperature Sensors are fitted to measure the temperature of pipe walls for radial outward heat flow measurement. Inside the inner pipe, a Nichrome wire heater is placed axially. A PID Controller is provided for controlling the heat input. Electronic energymeter will be provided to measure
the heat input.
Additional Information:
- Item Code: RLHT102
- Pay Mode Terms: Other
View Complete Details
| Primary Exchanger Material | Brass, Copper |
| Tube Material | Brass, Copper, Steel |
| Voltage | 220-440V |
| Frequency | 50-60Hz |
| Power Source | Electric |
| Finish | Paint Coated |
Heat exchanger is a device in which heat is transferred from one fluid to another. The apparatus consists of a concentric tube heat exchanger. Hot water flows through inner tube in one direction only and cold water flows through the outer tubes. Direction of cold fluid flow can be changed from parallel or counter to hot water so that unit can be operated as parallel or counter flow heat exchanger. Flow rates of hot and cold water are measured using Rotameters. A magnetic drive pump is used to circulate the hot water from a re-cycled type water tank, which is fitted with heaters and Digital
Temperature Controller.
EXPERIMENTATION-
-To calculate the Rate of Heat Transfer
-To calculate the LMTD.
-To calculate the Overall heat transfer co-efficient.
-To compare the performance of Parallel and Counter flow heat exchanger
Additional Information:
- Item Code: RLHT-109
- Pay Mode Terms: T/T (Bank Transfer),Other
View Complete Details
| Medium Used | Water |
| Material | Mild Steel |
| Voltage | 220-440V |
| Frequency | 50-60Hz |
| Finish | Paint Coated |
The Unit consists of a strong cylinder containing fluid. A water cooled coil in the upper part of the
cylinder condenses the vapour and returns it to the boiling liquid. The condenser cooling water rate can
be measured and controlled also.
EXPERIMENTATION-
- To plot graph of heat flux & temperature difference between metal & liquid
-To calculate amount heat taken away by water from condensing vapour.
Additional Information:
- Item Code: RLHT-108
- Pay Mode Terms: T/T (Bank Transfer),Other
View Complete Details
Heat Transfer Apparatus
₹ 55,000/PieceGet Latest Price
| Material | Aluminium |
| Heat Transfer Type | Evaporators/Boilers |
| Usage/Application | For HVAC and Refrigerator |
| Flow Type | Cross Flow |
| Country of Origin | Made in India |
At Reliant Lab, we specialize in providing high-quality precision instruments and equipment to meet the diverse needs of scientific, industrial, and educational institutions. With a deep commitment to excellence, our product range includes advanced Binocular Research Microscopes, state-of-the-art Testing Machines, efficient Rotary Vacuum Drum Filters, and precision-engineered Telescopes.
Our Binocular Research Microscopes are designed for clarity and accuracy, making them ideal for detailed scientific studies and research applications. We offer a variety of models to suit different levels of magnification and functionality, ensuring reliable results for researchers and professionals.
Our Testing Machines are built to withstand rigorous use, providing precise measurements and data for a wide range of materials and products. Whether for quality control, research, or educational purposes, our machines deliver accurate, repeatable results.
Our Rotary Vacuum Drum Filters are engineered for efficiency and durability, serving industries where filtration of liquids and solids is essential. They are designed to optimize the filtration process, saving time and resources.
Additionally, we offer high-performance Telescopes for both amateur astronomers and professionals, providing clear and detailed views of the cosmos. At [Your Company Name], we are dedicated to innovation, quality, and customer satisfaction, supporting our clients in achieving their goals with the best tools and technologies.
View Complete Details
| Medium Used | Water |
| Material of Construction | Mild Steel |
| Voltage | 220-440V |
| Brand | Reliant Lab |
| Finish Type | Paint Coated |
| Power Source | Electric |
| Frequency | 50-60Hz |
| Automation Grade | Automatic |
We are among the reputed organizations, deeply engaged in offering an optimum quality range of Shell and Tube Heat Exchanger.
Other Details:
Shell and Tube Heat Exchanger are popular in process industries
because they occupy less space and offer reasonable temperature
drop. The apparatus consists of fabricated shell, inside which tubes
with baffles on outer side are fitted. The present set up is a 1-2 heat
exchangers, with cold water flows through shell. Valves are
provided to control the flow rates of hot and cold water. Flow rates
of hot and cold water are measured using Rotameters. A magnetic
drive pump is used to circulate the hot water from a re-cycled type
water tank, which is fitted with heaters and Digital Temperature
Controller.
Additional Information:
- Item Code: RLHT-110
- Pay Mode Terms: T/T (Bank Transfer),Other
View Complete Details
| Power Source | Electric |
| Voltage | 220-440V |
| Frequency | 50-60Hz |
| Brand | Reliant Lab |
| Material | Mild Steel |
Being a leading firm in this industry, we are deeply engaged in offering a high-quality range of Helical Coil Heat Exchanger.
Other Details:
The apparatus consists of fabricated shell, inside which coil tubes
on outer side are fitted. The present set up is a heat exchanger, with
cold water flows through shell. Valves are provided to control the
flow rates of hot and cold water. Flow rates of hot and cold water
are measured using Rotameters. A magnetic drive pump is used to
circulate the hot water from a re-cycled type water tank, which is
fitted with heaters and Digital Temperature Controller.
Additional Information:
- Item Code: RLHT113
- Pay Mode Terms: T/T (Bank Transfer),Other
View Complete Details
| Usage/Application | Lab Testing |
| Brand | Reliant Lab |
| Material | Stainless Steel |
| Shape | Rectangular |
| Automation Type | Automatic |
| Country of Origin | Made in India |
Natural Convection Apparatus:
The unit consists of a vertical brass pipe heated by a cartridge heater inside it. The pipe looses heat to atmosphere by natural convection. It is fitted in an enclosure to provide undisturbed natural convection currents. Thermocouples are attached on the pipe to measure local temperatures. Heater input is measured on voltmeter and ammeter. Thus students can determine overall heat transfer coefficient and local transfer coefficients in natural convection at various heat transfer rates.
Additional Information:
- Delivery Time: Ready Stock
View Complete Details
| Application | Industrial |
| Brand | Reliant Lab |
| Country of Origin | Made in India |
| Material | Mild Steel |
| Finish Type | Paint Coated |
| Power Source | Electric |
| Voltage | 220-440V |
| Frequency | 50-60Hz |
| Automation Grade | Automatic |
The present setup is designed to study the critical heat flux of a given nichrome wire. The setup consists of temperature controlled water bath with controller. Temperature of the water bath can be varied from ambient to 80C to achieve different environment for nichrome wire. Test heater wire is placed in the bath & voltage is varied by variac provided. The system is complete with digital temperature controller, voltmeter, ammerter & voltage control facility.
EXPERIMENTATION :
- To determine the critical heat flux of given wire.
- To study the pool boiling phenomenon upto Critical Heat flux point
Additional Information:
- Item Code: RLHT-107
- Pay Mode Terms: T/T (Bank Transfer),Other
View Complete Details
- Developed and Managed by IndiaMART InterMESH Limited
















































