X
View Mobile Number 70% Response Rate
Hi
I agree to the terms and privacy policy
Verifying...
1

Have a requirement?
Get Best Price

Hi
I agree to the terms and privacy policy
Verifying...
1

Have a requirement?
Get Best Price

Industrial Cables

Providing you the best range of Ratnaflex Cable, Control Cables, Ratnaflex-M Cables, Braided Cables, Shielded Cables and Armoured & Unarmoured Cables with effective & timely delivery.
Rs 80/ Meter(s)
Rs 50/ Piece(s)
Rs 50/ Meter(s)
Rs 50/ Meter(s)
Rs 55/ Meter(s)

Ratnaflex Cable
Interested in this product?
Get Best Quote

Ratnaflex Cable

Rs 80 / Meter(s)Get Latest Price

Brandshensen
Usage/ApplicationIndustrial
Length100 m
SizeAs per requirement
Protection TypeShielded
Country of OriginMade in India

Conductor: Compactly bunched, electrolytic grade, annealed copper with high flexibility according to class 5 conductor as per IS 8130.
Available in various sizes from 0.5 sq. mm to 300 sq. mm.

Colours: Red, Blue, Green, Yellow, Grey & Black

Packing: 100 mtrs. Coils. Longer lengths can be made available on request




* The above data is indicative and may be revised without prior intimation. The above dimensions are not applicable for UL 1007 & 1569. Conductor as per IS 8130: 84, Class 5

View Complete Details

Yes, I am interested!

Control Cables
Interested in this product?
Get Best Quote

Control Cables

Rs 50 / Piece(s)Get Latest Price

Applications: These cables are used for flexible use for medium mechanical stresses with Free Movement without tensile stress in dry & moist condition for measuring and control cables in tool machines, conveyor belts, production lines in machinery production and in steelproduction.

Conductor: Annealed Bare Copper as per IS 8130, Class 5

Insulation PVC: Type A conforming to IS 5831

Sheath Colour: Black / Grey

PVC Sheath: Type ST-1 conforming to IS 5831.HR, FR and FRLS sheathing can be provided as per requirement.

Core Colours: Black with white numbering + Green / Yellow (earth core)

Rated Voltage: 300/500 V

Test Voltage: 2000 V A.C

Min. Bending Radius: Flexing 7.5 x the overall dia.of cable

Fixed Installation: 4 x the overall dia. of cable 105 C

Max Short Circuit Temperature: 160 C

Minimum Laying Temperature: Upto -15O C

These cables comply with the requirements of DIN VDE 0245, 0281, 0293, 295


View Complete Details

Yes, I am interested!

Ratnaflex-M Cables
Interested in this product?
Get Best Quote

Ratnaflex-M Cables

Rs 50 / Meter(s)Get Latest Price

Conductor: Compactly bunched, electrolytic grade, annealed copper with high flexibility according to class 5 conductor as per IS 8130 sizes from 0.5 sq. mm to 50.0 sq. mm.

Colours: Black & Grey. White available on request.

Packing: 100 mtr. coils. Longer lengths can be made available on request.





* The above data is indicative and may be revised without prior intimation. The above dimensions are not applicable for UL 1007 & 1569. Conductor as per IS 8130: 84, Class 5

View Complete Details

Yes, I am interested!

Braided Cables
Interested in this product?
Get Best Quote

Braided Cables

Rs 50 / Meter(s)Get Latest Price

Applications: Is suitable for interconnection of electrical measuring devices to Instrument panel or instrument. Measuring, monitoring and control in machine tool manufacturing, in plant engineering, in all places where electrical interference fields can distort a signal transmission or where Interference pulses arising in the mains must be confined.

Technical Data: Special PVC data cables, adapted to DIN VDE 0245
The material used in manufacture is cadmium free and contains no silicone and free of substances harmful to the wetting properties of Lacquers.

Coupling Resistance: < 250 ohm

Temperature Range: Flexing -5 C to +80 C

Nominal Voltage: Uo / 500 V

Test Voltage: 3000 V.

Insulation Resistance: Min. 20 Mohm x km

Mutual Capacitance: According to different cross sections Core / Core approx, 150 nF / km. Core / Screen approx, 270 nF / km

Minimum Bending Radius: Approx. 10 x cable

Cable Structure: Bare copper, fine wire conductors, bunch 0 0 Fixed Installation -20 C to +80 C stranded to IS 8130 class 5 and IEC 60228 class 5. Core insulation of special PVC Type A IS 5831, TI 1 DIN VDE 0207 Part 4. Coloured cores upto 4 cores only. Continuous numbering in white and one green / yellow core from 5 core onwards. Cores stranded in layers with optimal lay-length. Core Wrapping withcopper mylartape. Tinned copper braided screen, Approx. 85% coverage. Special PVC outer sheath TYPE ST1 of IS 5831, TM2 DIN VDE 0281 Part 1 and HD 21.1, sheath colour grey. Extensively Oil Resistant, Chemical Resistant. PVC self- extinguishing and flame retardant, test according to IS 694, DINVDE 0472 Part 804 and IEC 60332-1



* The above data is indicative and may be revised without prior intimation. The above dimensions are not applicable for UL 1007 & 1569. Conductor as per IS 8130: 84, Class 5

 

View Complete Details

Yes, I am interested!

Shielded Cables
Interested in this product?
Get Best Quote

Shielded Cables

Rs 55 / Meter(s)Get Latest Price

Core Colours :upto 4 cores,
  Black with white numbering + yellow/green
Sheath Colour:Grey, Black and White
Conductor:Annealed Bare Copper as per IS 8130
Insulating PVC:Type A conforming to IS 5831
Shield :Aluminium Mylar taped wrapped, over all laid up cores alongwith annealed tinned copper drain wire. In case of multipairs / multitriads individual pair/triad is wrapped with Aluminium Mylar tape alongwith drain wire and identification of pair/triad is done by numbered black core.
 
PVC Sheath:Type ST-1 conforming to IS 5831.
HR, FR and FRLS sheathing can be provided as per requirement.
 
Rated Voltage:300/500 V
Test Voltage :1000 V A.C. for 1 minutes.
Min. Bending Radius:6 times the overall diameter of cable
Tensile Strength:12.50 N per sq. mm of PVC insulation and sheath
Max. Working Temp.:700C, also available for 850C and 1050C as per requirement.
Max. Short Circuit Temp.:160°C
Minimum Laying Temp.:-15°C
Application :Is suitable for interconnection of electrical measuring devices to instrument panel or instrument. Measuring, monitoring and control in machine tool manufacturing, in plant engineering, in all places where electrical interference fields can distort a signal transmission or where interference pulses arising in the mains must be confined.
 

View Complete Details

Yes, I am interested!

Armoured & Unarmoured Cables
Interested in this product?
Get Best Quote
Applications: Heavy Duty Power and Control Cables are used for Underground power supply by utility provider for Street Lights, Industrial Automation with mechanical strength for protection on insulated cores and other industrial applications.

Specifications: IS 1554 (P-1)
ConstructionIS Specifications
Conductor : ETP Grade Copper8130
Insulation : PVC Type A or C5831
Inner Sheath : PVC Type ST1 or ST25831
Armour : Galvanised Steel Wire Strip3975
Outer Sheath : PVC Type ST1 or ST25831


The sheath is also provided in with FR and FRLSH PVC

Core Identification: For power cable and control cable upto 4 cores, the cores are identified by different colours as per IS 1554: (Part1)

Single Core : Red, Yellow, Blue, Black, etc. (only unarmoured).
2 Core : Red and Black.
3 core : Red, Yellow and Blue.
4 Core : Red, Yellow, Blue and Black.
5 Core : Red, Yellow, Blue, Black and Grey.







Table - B Current ratings

The current rating given in tables are based on normal conditions of installation described below:

  1. Maximum Conductor temperature 70O C for PVC insulation & 80O C for HRPVC insulation.
  2. Thermal Resistivity of soil 150O C cm/w
  3. Thermal Resistivity of PVC 650O C cm/w
  4. Ground temperature 40O C
    (To the highest point of cable laid direct in the ground)
  5. Depth of laying 75cms



Note: For cables in air , no reduction in current rating is necessary provided that

  1. The horizontal clearance between circuits is (a) not less than six times the overall diameter of an individual cable, and (b) not less than the overall width of an individual circuit, except that the horizontal clearance may need not in any case exceed 150mm.
  2. If the number of circuits exceeds 4, they are installed in a horizontal plane. However, for installation conditions other above, current rating factors incorporated in IS 3961 Part II please be applied.

The following points should be taken in to consideration before selecting any particular size and type of cable:

  1. The system of power & voltage source where the cables are being used.
  2. Conditions of installation at site.
  3. Current carrying capacity of cable.
  4. Voltage drop of cable.
  5. Short circuit capacity of cable.
  6. Availability of the selected size of cable.

* The above data is indicative and may be revised without prior intimation.

View Complete Details

Yes, I am interested!

RR Kabel Shramik Cables
Interested in this product?
Get Best Quote

RR Kabel Shramik Cables

Get Latest Price

USP

  1. High Flexibilty.
  2. Water Resitant PVC for underwater applications.

Conductor : Compactly bunched, electrolytic grade, annealed copper with superb flexibility according to harmonized grades HO5V-K and HO7V-K available in various sizes from 0.5 sq. mm to 300 sq. mm. Unilay conductor will be provided on special order from 1 to 4 sq. mm.

Insulation : Generally available with Standard PVC insulation and PVC sheathing. Choice of insulation and sheathing is available against specific need.

Standard Sheath Colours : GREY & BLACK

Packing : 100 mtr. Coils. Longer lengths supplied on order.

Submersible File Cable (Three Core) voltage grade 1100V, conforming to IS: 694- 1990

 

Nominal area of
conductor
Sq. mm
Construction
Size & item
mm
Thickness of PVC
insulation (Nom)
mm
PVC outer e
Sheath (Nom)
mm
Max Resistance
per km at 20°C
Ohms
Approx
Overall Dimension
(WXT) mm
Current Carrying
Capacity at 40°C
amp.
1.5
2.5
4
6
10
16
25
22/0.3
36/0.3
56/0.3
84/0.3
140/0.3
126/0.4
196/0.4
0.8
0.9
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4
2.0
12.10
7.41
4.95
3.30
1.91
1.21
0.78
11.8 x 5.8
14.1 x 6.75
16.4 x 7.5
18.1 x 8.3
22.5 x 9.5
25.3 x 11.3
32 x 14.0
18
24
32
42
55
75
100


SEVLECTION GUIDE FOR CORE FLAT CABLES HP Vs Current : The full load current for submersible pump motors, 3 phase, 50 hertz, 415-440

 

HP5.07.510.012.515.517.520.025.030.0

Amps.
7.511.015.019.022.825.825.535.843.0


NOTE : Current derating factors as per IS 3961 part 5 shall be applicable for different usage conditions.

View Complete Details

Yes, I am interested!
4.7/5★★★★★★★★★★

Reviewed by 3 Users

5 star2

4 star1

3 star0

2 star0

1 star0

Most Relevant Reviews

S

Sharib Ansari | Irshad Electronic| Meerut, Uttar Pradesh

★★★★★ ★★★★★

13-June-21

K

Krishna Ganapumane | Shrikrishna Electrical & Service| Uttara Kannada, Karnataka

★★★★★ ★★★★★

24-July-20

super

Tell us what you need, and we’ll help you get quotes
Tell us what you
need
Receive seller
details
Seal the deal
Pay with IndiaMART
Tell us what you need, and we’ll help you get quotes
I agree to the terms and privacy policy