- Rccb Residual Current Circuit Breaker 40A 2POLE
- Schneider 25A Four Pole Rccb
- 3 Pole Power Contactors - D Model
- Schneider 10A Single Pole MCB
- Schneider MCB 6 32 Amp 2 Pole
- 3 Pole 63A Schneider MCB
- Four Pole MCB-Schenider
- Schneider 25a Double Pole Rccb
- Schneider 40a Four Pole Rccb
- 32Amp 3Pole MCB
- SWITCH DISCONNECTOR 3POLE 100A
- Motor Circuit Breakers-Schneider
- Schneider Electric Mcb
- Schneider Soft Starter
- Motor Protection Circuit Breaker
- 3 Pole Power Contactors-F Model
- 3 Pole Ac Power Contactor
Schenider-MCB
Rccb Residual Current Circuit Breaker 40A 2POLE
₹ 2,650/PieceGet Latest Price
Minimum Order Quantity: 1 Piece
| Sensitivity | 30mA |
| No. of Poles | Double Pole |
| Voltage | 240V |
| Frequency | 50Hz |
| Certification | IS Certified |
| Rated Current | 40A |
| Phase | 1 Phase with neutral |
| Brand | Schneider |
| Model Name/Number | A9N |
| Network Type | AC |
| Cat Number | A9N16204 |
| Connection Type | 2POLE |
| Storage temperation | -40 TO 85 DegreeC |
| Breaking Capacity | 500 A conforming to EN/IEC 61008-1 |
| Country of Origin | Made in India |
This Acti9 RCCB-ID product is a residual current circuit breaker (RCCB). It is a 4P circuit breaker with 125A In rated current, 500mA earth leakage sensitivity and B type protection class. This product protects against electrical shock by indirect contact and fire hazards. The RCCB-ID B type residual current circuit breakers provide specific protection of three phase installations and people. The Acti9 RCCB-ID ensures protection in all industrial and tertiary buildings. This product is compliant with IEC 61008, EN 61008 and VDE 0664 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1250A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has an electrical endurance going up to 2000 cycles and a mechanical endurance going up to 5000 cycles. The Ue rated operational voltage is 230VAC or 400VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz or 60Hz. The width in 9mm pitches is 8. The product colour is light grey (RAL7035). The dimensions are (W) 72mm x (H) 86mm x (D) 76mm. The weight is 450g. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -25°C to 40°C. The storage temperature is from -40°C to 85°C. arrow2_down
Additional Information:
- Item Code: A9N16204
- Production Capacity: 40A
View Complete Details
| Sensitivity | 30mA |
| No. of Poles | Four Pole |
| Voltage | 415V |
| Frequency | 50Hz |
| Certification | EN/IEC 61008-1 |
| Rated Current | 25A |
| Ambient Air Temperature For Operation | -5 TO 40 DegreeC |
| Wire Stripping Length | 14 mm for top or bottom connection |
| Locking Options Description | Padlocking device |
| Suitability for Isolation | YES |
| Electrical Durability | 4000 cycles |
| Brand | Schneider |
| Phase | 4P |
| Model Name/Number | A9N16251 |
| ambient air temperature for storage | 40 TO 85 DegreeC |
| Breaking Capacity | 500 A conforming to EN/IEC 61008- |
| Storage Temperature | -40 TO 85 DegreeC |
| Mechanical Durability | 4000 cycles |
| Relative Humidity | 95 % at 55 DegreeC |
| Local signalling | ON, OFF, fault trip |
| Tightening Torque | 3.5 N.m top or bottom |
| Neutral position | Left |
| Net Weight | 370g |
| Operating Temperature | -5 TO 40 DegreeC |
| Country of Origin | Made in India |
Acti 9 xID and ID 125 RCCBsActi 9 xID & ID 125 Residual Current Circuit Breaker (RCCB) up to 125A
Residual Current Circuit Breaker or RCCB is a type of circuit breaker that ensures electrical protection and prevents accidents, deaths and other mishaps. This device senses current and interrupts low voltage circuits in case of faults by disconnecting the primary circuit within seconds.The Acti 9 xID and ID 125 by Schneider Electric are professional-grade RCCBs that provide optimum safety with long and reliable service.
Additional Information:
- Item Code: A9N16251
- Production Capacity: 25A ,30mA
- Packaging Details: Unit Type of Package 1 PC
View Complete Details
| Model Name/Number | LC1E |
| Number Of Poles | 3 |
| Brand | Schneider |
| Voltage | 415 |
| Phase | Three Phase |
| Electricity Type | AC |
| Usage/Application | Industrial |
Conformance to IEC 60947-4-1, CE MarkingCurrent Rating: 6A to 630A, AC-3 Rating.Type 2 RSC available with Fuse, MPCB and MCCB
View Complete Details
| No.of Poles | Single Pole |
| Voltage | 220...240 V AC 50/60 Hz 12...48 V DC 60 V DC |
| Type | C Curve |
| Breaking Capacity | 10000 A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1 15 kA Icu at 220...240 V AC 50/60 Hz c |
| Curve Type | C |
| Number of Poles | Single Pole |
| Poles Number | 1 Pole |
| Brand | Schneider |
| Classification | Type C, Type D |
| Frequency | 50/60 Hz |
| Material | Porcelain |
| Certification | IS/IEC 60898-1 |
| Rated Shortcircuit Breaking Capacity | 5 kA conforming to EN/IEC 60947-2 - 12...48 V DC 6 kA conforming to EN/IEC 60947-2 - 60 V DC 7.5 kA |
| Applicable Standard | Category A conforming to EN/IEC 60947-2 |
| Range | Acti 9 |
| Mounting Type | Clip-on |
| Condition | New |
| Country of Origin | Made in India |
| Rated Current | 6A,10A, 16A, 20A, 25A, 32A |
Miniature circuit breaker - Acti 9 xC60 MCBsIndustrial Miniature Circuit Breaker (MCB) up to 63 AFor secure and sound operations in an industry, one requires a foolproof system powered by latest technology and modern infrastructure. To back the entire system and protect it from unwanted breakdown, heavy duty Miniature circuit breaker is required. Industrial MCBs are much more reliable than the domestic ones. Schneider Electric India caters the industrial segment by delivering best in class industrial Miniature circuit breaker(MCBs).
View Complete Details
| No.of Poles | Double Pole |
| Brand | Schneider |
| Voltage | 240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC |
| Type | C Curve |
| Breaking Capacity | 15kA |
| Curve Type | C |
| Number of Poles | 2 Pole |
| Poles Number | 2 Pole |
| Classification | Type C |
| Frequency | 50/60 Hz |
| Material | Porcelain |
| Ambient air temperature for Operation | -30 to 70 DegreeC |
| Certification | IS/IEC60947-2 |
| Weight | 0.236KGS |
| Part Number | A9N2P10C |
| Cat Number | Acti9 |
| Condition | New |
| Ambient Air Temperature for Storage | -40 to 85 DegreeC |
| Magnetic Tripping Limit | 8 x In +/- 20 % |
| Wire stripping length | 13 mm for top or bottom connection |
| Control Type | Toggle |
| Poles Description | 2Pole |
| Mounting Mode | Clip-on |
| Country of Origin | Made in India |
| Rated Current | 6A,10A, 16A, 20A, 25A, 32A |
Miniature circuit breaker - Acti 9 xC60 MCBsIndustrial Miniature Circuit Breaker (MCB) up to 63 AFor secure and sound operations in an industry, one requires a foolproof system powered by latest technology and modern infrastructure. To back the entire system and protect it from unwanted breakdown, heavy duty Miniature circuit breaker is required. Industrial MCBs are much more reliable than the domestic ones. Schneider Electric India caters the industrial segment by delivering best in class industrial Miniature circuit breaker(MCBs).
Additional Information:
- Item Code: Acti9N
- Production Capacity: 10A
View Complete Details
| No.of Poles | Triple Pole |
| Brand | Schneider |
| Type | C Curve |
| Breaking Capacity | 15 kA |
| Certification | IS/IEC 60898-1 |
| Poles Number | 3 Pole |
| Rated Current | 63A |
| Classification | Type C |
| Voltage | 240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC |
| Frequency | 50/60 Hz |
| Rated Shortcircuit Breaking Capacity | 10000 A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz confo |
| Rated Impulse Withstand Voltage | 6 kV conforming to EN/IEC 60947-2 |
| Applicable Standard | Category A conforming to EN/IEC 60947-2.Category A conforming to EN/IEC 60947-2 |
| Condition | New |
| Country of Origin | Made in India |
Miniature circuit breaker - Acti 9 xC60 MCBsIndustrial Miniature Circuit Breaker (MCB) up to 63 AFor secure and sound operations in an industry, one requires a foolproof system powered by latest technology and modern infrastructure. To back the entire system and protect it from unwanted breakdown, heavy duty Miniature circuit breaker is required. Industrial MCBs are much more reliable than the domestic ones. Schneider Electric India caters the industrial segment by delivering best in class industrial Miniature circuit breaker(MCBs).
Additional Information:
- Item Code: A9N3P63C
- Production Capacity: 63A
View Complete Details
| Number of Poles | 4 Pole |
| No.of Poles | 4 Pole |
| Brand | Schneider |
| Breaking Capacity | 10000 A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz confo |
| Poles Number | 4 Pole |
| Classification | Type B |
| Voltage | 240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 220...250 V DC |
| Frequency | 50/60 Hz |
| Rated Shortcircuit Breaking Capacity | 7.5 kA conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 6 kA conforming to EN/IEC 60947-2 - 22 |
| Rated Impulse Withstand Voltage | 6 kV conforming to EN/IEC 60947-2 |
| Color | White |
| Dimension | Height 85cm, Width 72mm, Depth 77.5mm |
| Weight | 0.415 Kgs |
| Condition | New |
| Rated Current | 6A, 16A, 20A, 25A, 32A, 40A, 50A, 63A |
Breaking Capacity as per IEC 60898 and IS/IEC 60898-1, Icn = 10kA .Breaking Capacity as per IEC 60947-2, Icn = 15kA, upto 40A .Can be used for DC application upto 60V per pole .Higher system performance with optimized cost: Cascading* .Increased System Continuity: Discrimination* .Higher Installation Life: Energy Limitation Class 3, Fast Closure Mechanism .Ease, Speed and Flexibility of installation - Biconnect, Line-Load Reversible .Field-fittable auxiliaries for advance protection and monitoring .Positive Contact Indication for assurance of disconnection
View Complete Details
| Current Rating | 25A |
| Brand | Schneider |
| Number Of Poles | 2 |
| No. of Poles | Double Pole |
| Senstivity | 30 mA |
| Certification | IS Certified |
| Type | AC |
| Sensitivity | 30mA |
| Rated Insulation Voltage | 440 V AC 50 Hz |
| Poles Number | 2 Pole |
| Rated Current | 25A |
| Voltage | 230...240 V AC 50 Hz |
| Frequency | 50 Hz |
| Material | Porcelain |
| Condition | New |
| Country of Origin | Made in India |
Acti 9 xID and ID 125 RCCBsActi 9 xID & ID 125 Residual Current Circuit Breaker (RCCB) up to 125A
Residual Current Circuit Breaker or RCCB is a type of circuit breaker that ensures electrical protection and prevents accidents, deaths and other mishaps. This device senses current and interrupts low voltage circuits in case of faults by disconnecting the primary circuit within seconds.The Acti 9 xID and ID 125 by Schneider Electric are professional-grade RCCBs that provide optimum safety with long and reliable service.
Additional Information:
- Item Code: A9N16201
- Production Capacity: 25A
- Packaging Details: Unit Type of Package 1 PCE
View Complete Details
| Current Rating | 40A |
| Number Of Poles | 4 |
| Senstivity | 30mA |
| Type | AC |
| Rated Insulation Voltage | 400...415 V AC 50 Hz |
| Poles Number | 4 Pole |
| Rated Current | 40A |
| Brand | Schneider |
| Voltage | 400...415 V AC 50 Hz |
| Rated Frequency | 50Hz |
| Protection Degree | IP20 |
| Reference Standard | EN 61008-2-1 EN/IEC 61008-1 IEC 61008-2-1 |
| Condition | New |
| Country of Origin | Made in India |
Acti 9 xID and ID 125 RCCBsActi 9 xID & ID 125 Residual Current Circuit Breaker (RCCB) up to 125A
Residual Current Circuit Breaker or RCCB is a type of circuit breaker that ensures electrical protection and prevents accidents, deaths and other mishaps. This device senses current and interrupts low voltage circuits in case of faults by disconnecting the primary circuit within seconds.The Acti 9 xID and ID 125 by Schneider Electric are professional-grade RCCBs that provide optimum safety with long and reliable service.
Additional Information:
- Item Code: A9N16254
- Production Capacity: 40A
- Packaging Details: Unit Type of Package 1 PCE
View Complete Details
| No.of Poles | Triple Pole |
| Type | C Curve |
| Voltage | 240V |
| Breaking Capacity | 15 kA |
| Rated Current | 32A |
| Number of Poles | 3 Pole |
| Model No. | A9N3P32C |
| Phase | 3 |
| Frequency | 50 Hz |
| Certification | IS/IEC60947-2 |
| Brand | Schneider |
| Country of Origin | Made in India |
Breaking Capacity as per IEC 60898 and IS/IEC 60898-1, Icn = 10kA .Breaking Capacity as per IEC 60947-2, Icn = 15kA, upto 40A .Can be used for DC application upto 60V per pole .Higher system performance with optimized cost: Cascading* .Increased System Continuity: Discrimination* .Higher Installation Life: Energy Limitation Class 3, Fast Closure Mechanism .Ease, Speed and Flexibility of installation - Biconnect, Line-Load Reversible .Field-fittable auxiliaries for advance protection and monitoring .Positive Contact Indication for assurance of disconnection
Additional Information:
- Item Code: A9N3P32C
- Production Capacity: 32A
View Complete Details
| Rated Current | AC-22A: 100 A AC 50/60 Hz 220/240 V AC-22A: 100 A AC 50/60 Hz 380/415 V AC-22A: 100 A AC 50/60 Hz 4 |
| Product Type | Distribution Box |
| Poles Number | 3 Pole |
| Brand | Schneider |
| Frequency | 50/60 Hz |
| Condition | New |
| Country of Origin | Made in India |
MCCB with adjustable settings, rated for 100 to 800 A, ideal for applications in small to medium sized buildings
Part of Easy Series
Molded-case circuit breakers (MCCB) with adjustable settings, rated from 16 to 630 A, ideal for applications in small to medium-sized buildings.
View Complete Details
| Current Rating | 80A |
| No.of Poles | 3 Pole |
| Rated Current | 690 V AC 50/60 Hz conforming to IEC 60947-2 -1.6 A |
| Brand | Schneider |
| Breaking Capacity | 100 KA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 KA Icu at 400/415 V AC 50/60 Hz co |
| Model Name/Number | GV2ME06 |
| Usage/Application | Circuit Breaker |
| Voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Rated Shortcircuit Breaking Capacity | 100 KA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 KA Icu at 400/415 V AC 50/60 Hz co |
| Applicable Standard | AC-3 conforming to IEC 60947-4-1 Category A conforming to IEC 60947-2 |
| Frequency | 50/60 Hz conforming to IEC 60947-4-1 |
| Country of Origin | Made in India |
Space saving in compact enclosures: the total volume is reduced to that of the motor starter assemblies. Wide adaptability: 6 busbar lengths from 344 to 1100 mm, 12 models of sockets, 23 mounting plates for motor starters up to 25 or 50 A
View Complete Details
| Number of Poles | 4 Pole |
| Rated Current | 10, 16, 20, 32, 40, 50 & 63 |
| Brand | Schneider |
| Product Type | Circuit Breaker, Molded Case |
| Poles Number | 2 Pole, 1 Pole, 3 Pole, 4 Pole |
| Classification | Type B, Type C, Type D |
| Voltage | 230V , 415V |
| Frequency | 50Hz |
| Material | Porcelain |
| Condition | New |
| Country of Origin | Made in India |
MCCB with adjustable settings, rated for 100 to 800 A, ideal for applications in small to medium sized buildings
View Complete Details
| Phase | Three Phase |
| Usage/Application | Crushers |
| Current | 17 Amps -590 Amps |
| Voltage | 415V |
| Model Name/Number | ATS0 |
| Brand | Schneider Electric |
| Condition | New |
Altivar Soft Starter ATS480Soft starters for Process & Infrastructures from 3 to 900 kW
Part of Altivar
The Altivar™ Soft Starter ATS480 is the next evolution of soft starters for digitization optimized to meet cybersecurity standard. Designed to address process and infrastructures, ATS480 simplifies project execution and maximizes the availability of your applications, even in the most demanding environments. ATS480 builds on the proven robustness and start/stop performance extending the lifetime of the ATS48 equipment and preserving your initial investment by reusing current design.View Complete Details
| Current Rating | 100A |
| Number of Poles | Double Pole |
| Brand | Schneider |
| Country of Origin | Made in India |
TeSys GV motor circuit breaker, 3 poles (3P), 4A/690V, for 3-phase motor applications 1.1-1.5kW@400V. It provides a thermal-magnetic protection with a thermal setting range 2.5-4A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control by push-button guaranteed for 100 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View Complete Details
| Model Name/Number | LC1F150 |
| Number of Poles | 3 Poles |
| Brand | Schneider |
| Switching Current | 250 |
| Phase | Three Phase |
| Electricity Type | AC |
| Usage/Application | Industrial |
TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 400A 250kW@440V. It provides a 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View Complete Details
| Model Number | LC1E0910 |
| Number of Poles | 3 |
| Brand | Schneider |
| Voltage | 415v |
| Phase | Three Phase |
| Usage/Application | Industrial |
High power contactor, TeSys Giga, 4 pole (4NO), AC-1 <=440V 700A, standard version, 100…250V wide band AC/DC coil
Contactors and Protection RelaysA power contactor is an electrical device used to turn an electrical circuit on and off. It's a multi-pole switch, which means it can control numerous power circuits with a single contactor. Regarded as a unique kind of relay, the main difference between the contractors and the relay is that the contactor relay is utilized in applications that require a larger current carrying capacity, whereas the relay is used in conditions that require a lower current carrying capacity.
Importance of Power Contractor Relays
It goes without saying that motor protection relays are vital cogs of any machinery system. They perform the important task of safeguarding the motor from burnout caused by overload. Schneider Electric's flagship line of contractors, TeSys provides top-quality performance along with a notable mechanical and electric life. Buyers even have the choice of purchasing an extensive range of accessories for motor & load control.
The TeSys Contactors can be bought with either of the IEC and NEMA applications and follows the global standardization grades. When a relay is utilised in order to switch a significant amount of electrical power through its contacts, it is designated a specific name: contactor relay. Contactors generally consist of multiple contacts, and those contacts in most cases normally-open, in order to guarantee that power to the load is shut off when the coil is in the de-energized state. Probably the most popular industrial use for Schneider Electric India’s contactors is in the regulation of electric motors.
Applications of Power Contactor Relays
In simple terms, contactor relays are electrically operated switches deployed for effectively controlling electric circuits. There are several types of contactor relays like 4-pole contactors, vacuum contactors, AC contactors, DC contactors, etc that are deployed in a variety of applications like automation circuits, protection circuits, control circuits, and more.
View Complete Details
- Developed and Managed by IndiaMART InterMESH Limited