X

SPB Engineers (India)

Kolkata

GST - 19**********1Z2

TrustSEAL

Mobile

Email

15 yrs

86% Response rate

View Mobile Number
Contact Supplier
Our Products
+View All

Power Engineering Smart Power System Trainer

  • Smart Power System Trainer
  • Smart Power System Generation Trainer
  • Smart Power System Synchronization Trainer
  • Smart Power System Double Bus Bar Trainer
  • Smart Power System Transmission & Distribution Trainer

  • Power Generation Smart Power System Double Bus Bar Trainer
  • Power Generation Smart Power System Double Bus Bar Trainer
  • Power Generation Smart Power System Double Bus Bar Trainer
Interested in this product?
Get Best Quote
Model Name/NumberXPO-SPS-DBB
Country of OriginMade in India
In Feeder Panel4 nos
Bus Coupler Panel2 nos.
Out Feeder Panel2 nos.
Section Coupler Panel1 no.
3 Phase Bidirectional Power cum Energy Meter Panel6 nos.
Phase Angle Meter Panel1 no.
37 Pin D (M) to 9 Pin D (F) Converter Panel1 no.
5 Pin to Shrouded Socket Converter Panel3 nos.
3 Phase Dimmer Panel1 no.
Transmission Line Panel1 no.
RLC Load Panel1 no.

Power Generation Smart Power System Double Bus Bar Trainer - XPO-SPS-DBB

Experiments:
  • Study of voltage variation & control
  • Study of voltage regulation for constant cos Φ
  • 3 bus load flow study
  • 4 bus load flow study

Features:
  • The model represents a double bus bar switching station with 9 switching bays
  • It is equipped in such a way that the requirements of both the grid and the power station operation are dealt in a practice oriented way
  • Two bus bar segments are represented
  • Here the interlocking conditions in a switching station can be learned in order to conduct safe switching operations, as the situation requires, on the grid and power plant
  • The double bus bar setup is used for 3 bus and four bus load flow study, study of voltage variation, control and voltage regulation for constant cos I
  • Can use different KVA rating grid transformer in absence of actual generation setup to simulate source of power
  • The XPO-SPS-DBB trainer can work in standalone mode with simulated grid sources as well as in conjunction with a Generation setup (XPO-SPS-GEN), a Synchronisation setup XPO-SPS-SYNC), HMI, RTU, SCADA software and panels

Specifications:
  • In feeder Panel
  • Bus Coupler Panel
  • Out Feeder Panel
  • Section Coupler Panel
  • 3 Phase Bidirectional Power cum Energy Meter Panel
  • Phase Angle Meter Panel
  • 37 pin D (M) to 9 pin D (F) Converter Panel
  • 5 Pin to Shrouded Socket Converter Panel
  • 3 Phase Dimmer Panel
  • Transmission Line Panel
  • RLC Load Panel 


Additional Information:

  • Delivery Time: 12 weeks from the date of receipt of order

View Complete Details

Yes, I am interested!

  • Power Engineering Smart Power System Trainer - XPO-SPS
  • Power Engineering Smart Power System Trainer - XPO-SPS
  • Power Engineering Smart Power System Trainer - XPO-SPS
  • Power Engineering Smart Power System Trainer - XPO-SPS
  • Power Engineering Smart Power System Trainer - XPO-SPS
  • Power Engineering Smart Power System Trainer - XPO-SPS
  • Power Engineering Smart Power System Trainer - XPO-SPS
  • Power Engineering Smart Power System Trainer - XPO-SPS
Interested in this product?
Get Best Quote

Power Engineering Smart Power System Trainer - XPO-SPS

Get Latest Price

Minimum Order Quantity: 1 Set

Product Brochure Watch Video

Model Name/NumberXPO-SPS
UsagePower Engineering Smrt Power System Trainer
Country of OriginMade in India

Smart Power System Trainer - XPO-SPS

 

Experiments:

  • Automatic as well as manual synchronisation of generator with grid supply

  • Study of V curve and inverted V curve

  • Study of generator performance chart

  • Study of generator protection for differential, over current, over / under voltage, over / under frequency, reverse power and earth faults using generator protection relay

  • Study of voltage variation and control

  • Study of voltage regulation for constant cosΦ

  • 3 bus load flow study

  • Study of no load test and Ferranti effects on transmission line

  • Load test and calculation of efficiency, regulation and power flow in pi model of TL

  • Load test and calculation of efficiency, regulation and power flow in short model of TL

  • Study of symmetrical and asymmetrical faults on transmission line

  • Study of distance protection using distance relay

  • Study of auto reclose function of distance relay

  • Study of distribution transformer protection for differential and over current faults

  • 4 bus load study


Features:

  1. The objective of Smart Power System Trainer is to develop a real time automated power system network and control test-bed at the laboratory level to enhance student understanding about power system testing and validation
  2. SPS system consists of Generation, Synchronisation, Double Bus Bar, Transmission & Distribution power engineering setups, integrated numeric protection relays for generator protection, synchronisation relay, distance protection, transformer protection, RTUs with Ethernet & RS485/MODBUS ports, touch panel HMIs, supervisory controller / touch panel PC with latest SCADA software, preformed patch cords / cables to integrate seamlessly various parts into single system, aluminum profile tables with under trolleys / drawers etc.
  3. Resources needed by respective setups are placed on trolleys below the tables
  4. The individual modular flat demo panel setups can also be worked jointly (automated SCADA) or severally (manual experiments) thereby accommodating more student capacity whenever time demands
  5. Facilitates easy and safe wiring by students due to use of 4mm sturdy Shrouded banana patch cords for high voltage circuits
  6. Student friendly Instructor Guide & Student Workbooks giving detail experiment procedures, wiring schedule & tabular results

Power Engineering Setups & Resources:
  • Generation Trainer - Model: XPO-SPS-GEN
  • Synchronisation Trainer - Model: XPO-SPS-SYNC
  • Double Bus Bar Trainer - Model: XPO-SPS-DBB
  • Transmission & Distribution Trainer - Model: XPO-SPS-TLD
  • Transformers: Generator Group, Grid Transformer, Distribution Transformer

SCADA Components:
  • PCs, supervisor's desk, HMIs as local stations, UPS
  • Multi drop SCADA Software
  • SCADA supported screens: generator control panel, synchronisation, generator differential protection relay, load selection, double bus bar, transmission line, symmetrical & asymmetrical fault, distance protection, distribution transformer differential protection, power measurement, alarm & event management
  • RTUs with PLCs, converter cum distribution panels, power topology control, fault insertion & CB control, multi function meters, phase angle measurement meters, protection relays, variable voltage variable frequency drive


Additional Information:

  • Delivery Time: 12 weeks from the date of receipt of order

View Complete Details

Yes, I am interested!

  • Power Engineering Smart Power System Generation Trainer
  • Power Engineering Smart Power System Generation Trainer
  • Power Engineering Smart Power System Generation Trainer
  • Power Engineering Smart Power System Generation Trainer
  • Power Engineering Smart Power System Generation Trainer
Interested in this product?
Get Best Quote
Usage/ApplicationLaboratory
Model Name/NumberXPO-SPS-GEN
Country of OriginMade in India
Input 3 Phase DOL Starter Panel1 no.
DC Volt meter & DC Ammeter Panel1 no.
Instrumentation Power Supply cum Multichannel DPM Panel1 no.
Variable AC & DC Supply Panel1 no.
IGBT Controlled VVVF Drive Panel1 no.
3 Phase Bidirectional Power cum Energy Meter Panel4 nos.
SCR Actuator (Variable DC) cum Sensor Signal Conditioning Panel1 no.
Generator Protection Relay Panel1 no.
CT Panel1 no.
415 / 110 V AC, 50 VA PT Panel1 no.
5 Pin to Shrouded Socket Converter Panel2 nos.
Generator Transformer Panel1 no.
3 Phase Squirrel Cage Induction Motor Panel1 no.
3 Phase Salient Pole Alternator Panel1 no.

Smart Power System Generation Trainer - XPO-SPS-GEN

Experiments:
  •  Automatic as well as manual synchronization of generator with grid supply 
  •  Study of V curve & inverted V curve 
  • Study of Generator performance chart 
  • Study of generator protection for differential, over current, over / under voltage, over / under frequency, reverse power and earth faults using generator protection relay

Features:
  • VFD drive is used to control brushless prime mover’s speed in manual using RTU / SCADA as well as in auto mode using synchronization relay
  • Multi function meters read the input voltage & frequency of generator output along with power analyser data
  • The generator / alternator coupled with prime mover have brought out six terminals from three phase 3 windings (RYBs). Every alternate terminal of RYB is shorted and connected together to form star connection (neutral) at the output of generator
  • The relay panel carries shrouded sockets to connect generator protection relay mounted below. The CT panel and PT panel provide necessary interface between real world & relay
  • Emergency stop mushroom switch is provided with security key lock on the profile rack


Technical Specifications:
  • Input 3 phase DOL Starter panel
  • DC Voltmeter & DC Ammeter Panel
  • Instrumentation Power Supply cum Multichannel DPM Panel
  • Variable AC and DC Supply Panel
  • IGBT Controlled VVVF Drive Panel
  • 3 Phase Bidirectional Power cum Energy Meter Panel
  • SCR Actuator (Variable DC) cum Sensor Signal Conditioning Panel
  • Generator Protection Relay Panel
  • CT Panel
  • 415 / 110 V AC, 50 VA PT Panel
  • 5 Pin to Shrouded Socket Converter Panel
  • Generator Transformer Panel
  • 3 Phase Squirrel Cage Induction Motor Panel
  • 3 Phase Salient Pole Alternator Panel


Additional Information:

  • Delivery Time: 12 weeks from the date of receipt of order

View Complete Details

Yes, I am interested!

  • Power Engineering Smart Power System Synchronization Trainer
  • Power Engineering Smart Power System Synchronization Trainer
  • Power Engineering Smart Power System Synchronization Trainer
  • Power Engineering Smart Power System Synchronization Trainer
Interested in this product?
Get Best Quote
Model Name/NumberXPO-SPS-SYNC
Usage/ApplicationPower Generation Smart Power System Synchronization Trainer
Country of OriginMade in India
Input 3 Phase DOL Starter Panel1 no.
Synchronization Panel1 no.
3 Phase Bidirectional Power cum Energy Meter Panel2 nos.
Mesh Bus Generator Panel1 no.
Mesh Bus Grid Panel1 no.
Synchronization Bus Switch Panel1 no.
415 / 110 V AC, 50 VA PT Panelnel2 nos.
Phase Angle Meter Panel1 no.
Synchronization Relay Panel1 no.
Transmission Line Panel1 no.
R Load Panel1 no.
Grid Transformer Panel1 no.

Power Engineering Smart Power System Synchronization Trainer - XPO-SPS-SYNC

Experiments:
  • Automatic as well as manual synchronization of generator with grid supply
  •  Study of V curve & inverted V curve
  •  Study of Generator performance chart

Features:
  • XPO-SPS-SYNC Trainer works only in conjunction with the Generation setup (XPO-SPS-GEN), HMI, RTU SCADA software and various panels
  • To synchronize the generator with the grid, this synchronization setup is used
  • Automatic operation can be performed in two ways, namely, from screen based generator control panel using increment and decrement screen buttons or using synchronization relay whose 4 contacts (increment and decrement) are read by  a RTU through 9 pin D (M) connector on synchronising relay panel & outputs two AO’s through 9 pin D connector on VFD panel and patch cording, one for excitation (V) control and the second for speed (f) control
  • Emergency stop mushroom switch is provided with security key lock on the vertical profile member

Specifications:
  • Input 3 phase DOL Starter Panel
  • Synchronization Panel
  • 3 Phase Bidirectional Power cum Energy Meter Panel 
  • Mesh Bus Generator Panel
  • Mesh Bus Grid Panel 
  • Synchronization Bus Switch Panel
  • 415 / 110 V AC, 50 VA PT Panel
  • Phase Angle Meter Panel
  • 37 pin D (M) to 9 pin D (F) Converter Panel
  • 5 pin to Shrouded Socket Converter Panel
  • Synchronization Relay Panel
  • Transmission Line Panel
  • R Load Panel
  • Grid Transformer Panel


Additional Information:

  • Delivery Time: 12 weeks from the date of receipt of order

View Complete Details

Yes, I am interested!

  • Power Engineering Smart Power System Transmission & Distribution Trainer
  • Power Engineering Smart Power System Transmission & Distribution Trainer
  • Power Engineering Smart Power System Transmission & Distribution Trainer
Interested in this product?
Get Best Quote
Model Name/NumberXPO-SPS-TLD
Usage/ApplicationPower Transmission and Distribution Trainer
Country of OriginMade in India
Input 3 Phase DOL Starter Panel1 no.
FWD-OFF-REV Switch Panel1 no.
3 Phase Bidirectional Power cum Energy Meter Panel3 nos.
VAR Compensation Panel (Dual Panel)1 no.
Differential Relay (Transformer Protection) Panel1 no.
CT Panel2 nos.
Distance Protection Relay Panel1 no.
415 / 110 V AC, 50 VA PT Panel1 no.
37 Pin D (M) to 9 pin D (F) Converter Panel1 no.
5 Pin to Shrouded Socket Converter Panel2 nos.
Distribution Transformer Panel1 no.
Transmission Line Panel1 no.
RLC Load Panel1 no.

Power Engineering Smart Power System Transmission & Distribution Trainer - XPO-SPS-TLD

Experiments:
  • Study of No Load test and Ferranti effects on transmission line
  • Load test and calculation of efficiency, regulation and power flow in pi model of TL
  • Load test and calculation of efficiency, regulation and power flow in short model of TL
  • Study of symmetrical and asymmetrical faults on transmission line
  • Study of distance protection using distance relay
  • Study of auto reclose function of distance relay
  • Study of distribution transformer protection for differential & over current faults


Additional Information:

  • Delivery Time: 12 weeks from the date of receipt of order

View Complete Details

Yes, I am interested!

Get in touch with us

Reach Us

SPB Engineers (India)Kolkata, West Bengal

R Burman (General Manager)

View Mobile Number86% Call Response Rate

Send SMS
Send Email
All Rights Reserved (Terms of Use)