- Full Height Single & Dual Lane 4 x 90 Degree Turnstile
- High Security Tubestile (Man Trap)
- Tripod Turnstile (Slim Housing) - Motorized Operation & Automatic Drop Arm Reset
- Full Height Single & Dual Lane 3 x 120 Degree Turnstile
- Tripod Turnstile (Slim Housing) - Electro Mechanical Operation and Manual Drop Arm Reset
- +5 more products
Power Engineering Smart Power System Trainer
- Smart Power System Trainer
- Smart Power System Generation Trainer
- Smart Power System Synchronization Trainer
- Smart Power System Double Bus Bar Trainer
- Smart Power System Transmission & Distribution Trainer
Power Generation Smart Power System Double Bus Bar Trainer
Get Latest Price
Minimum Order Quantity: 1 Set
| Model Name/Number | XPO-SPS-DBB |
| Country of Origin | Made in India |
| In Feeder Panel | 4 nos |
| Bus Coupler Panel | 2 nos. |
| Out Feeder Panel | 2 nos. |
| Section Coupler Panel | 1 no. |
| 3 Phase Bidirectional Power cum Energy Meter Panel | 6 nos. |
| Phase Angle Meter Panel | 1 no. |
| 37 Pin D (M) to 9 Pin D (F) Converter Panel | 1 no. |
| 5 Pin to Shrouded Socket Converter Panel | 3 nos. |
| 3 Phase Dimmer Panel | 1 no. |
| Transmission Line Panel | 1 no. |
| RLC Load Panel | 1 no. |
Power Generation Smart Power System Double Bus Bar Trainer - XPO-SPS-DBB
Experiments:
- Study of voltage variation & control
- Study of voltage regulation for constant cos Φ
- 3 bus load flow study
- 4 bus load flow study
Features:
- The model represents a double bus bar switching station with 9 switching bays
- It is equipped in such a way that the requirements of both the grid and the power station operation are dealt in a practice oriented way
- Two bus bar segments are represented
- Here the interlocking conditions in a switching station can be learned in order to conduct safe switching operations, as the situation requires, on the grid and power plant
- The double bus bar setup is used for 3 bus and four bus load flow study, study of voltage variation, control and voltage regulation for constant cos I
- Can use different KVA rating grid transformer in absence of actual generation setup to simulate source of power
- The XPO-SPS-DBB trainer can work in standalone mode with simulated grid sources as well as in conjunction with a Generation setup (XPO-SPS-GEN), a Synchronisation setup XPO-SPS-SYNC), HMI, RTU, SCADA software and panels
Specifications:
- In feeder Panel
- Bus Coupler Panel
- Out Feeder Panel
- Section Coupler Panel
- 3 Phase Bidirectional Power cum Energy Meter Panel
- Phase Angle Meter Panel
- 37 pin D (M) to 9 pin D (F) Converter Panel
- 5 Pin to Shrouded Socket Converter Panel
- 3 Phase Dimmer Panel
- Transmission Line Panel
- RLC Load Panel
Additional Information:
- Delivery Time: 12 weeks from the date of receipt of order
View Complete Details
Power Engineering Smart Power System Trainer - XPO-SPS
Get Latest Price
Minimum Order Quantity: 1 Set
Product Brochure Watch Video
| Model Name/Number | XPO-SPS |
| Usage | Power Engineering Smrt Power System Trainer |
| Country of Origin | Made in India |
Smart Power System Trainer - XPO-SPS
Experiments:
-
Automatic as well as manual synchronisation of generator with grid supply
-
Study of V curve and inverted V curve
-
Study of generator performance chart
-
Study of generator protection for differential, over current, over / under voltage, over / under frequency, reverse power and earth faults using generator protection relay
-
Study of voltage variation and control
-
Study of voltage regulation for constant cosΦ
-
3 bus load flow study
-
Study of no load test and Ferranti effects on transmission line
-
Load test and calculation of efficiency, regulation and power flow in pi model of TL
-
Load test and calculation of efficiency, regulation and power flow in short model of TL
-
Study of symmetrical and asymmetrical faults on transmission line
-
Study of distance protection using distance relay
-
Study of auto reclose function of distance relay
-
Study of distribution transformer protection for differential and over current faults
-
4 bus load study
Features:
- The objective of Smart Power System Trainer is to develop a real time automated power system network and control test-bed at the laboratory level to enhance student understanding about power system testing and validation
- SPS system consists of Generation, Synchronisation, Double Bus Bar, Transmission & Distribution power engineering setups, integrated numeric protection relays for generator protection, synchronisation relay, distance protection, transformer protection, RTUs with Ethernet & RS485/MODBUS ports, touch panel HMIs, supervisory controller / touch panel PC with latest SCADA software, preformed patch cords / cables to integrate seamlessly various parts into single system, aluminum profile tables with under trolleys / drawers etc.
- Resources needed by respective setups are placed on trolleys below the tables
- The individual modular flat demo panel setups can also be worked jointly (automated SCADA) or severally (manual experiments) thereby accommodating more student capacity whenever time demands
- Facilitates easy and safe wiring by students due to use of 4mm sturdy Shrouded banana patch cords for high voltage circuits
- Student friendly Instructor Guide & Student Workbooks giving detail experiment procedures, wiring schedule & tabular results
Power Engineering Setups & Resources:
- Generation Trainer - Model: XPO-SPS-GEN
- Synchronisation Trainer - Model: XPO-SPS-SYNC
- Double Bus Bar Trainer - Model: XPO-SPS-DBB
- Transmission & Distribution Trainer - Model: XPO-SPS-TLD
- Transformers: Generator Group, Grid Transformer, Distribution Transformer
SCADA Components:
- PCs, supervisor's desk, HMIs as local stations, UPS
- Multi drop SCADA Software
- SCADA supported screens: generator control panel, synchronisation, generator differential protection relay, load selection, double bus bar, transmission line, symmetrical & asymmetrical fault, distance protection, distribution transformer differential protection, power measurement, alarm & event management
- RTUs with PLCs, converter cum distribution panels, power topology control, fault insertion & CB control, multi function meters, phase angle measurement meters, protection relays, variable voltage variable frequency drive
Additional Information:
- Delivery Time: 12 weeks from the date of receipt of order
View Complete Details
Power Engineering Smart Power System Generation Trainer
Get Latest Price
Minimum Order Quantity: 1 Set
| Usage/Application | Laboratory |
| Model Name/Number | XPO-SPS-GEN |
| Country of Origin | Made in India |
| Input 3 Phase DOL Starter Panel | 1 no. |
| DC Volt meter & DC Ammeter Panel | 1 no. |
| Instrumentation Power Supply cum Multichannel DPM Panel | 1 no. |
| Variable AC & DC Supply Panel | 1 no. |
| IGBT Controlled VVVF Drive Panel | 1 no. |
| 3 Phase Bidirectional Power cum Energy Meter Panel | 4 nos. |
| SCR Actuator (Variable DC) cum Sensor Signal Conditioning Panel | 1 no. |
| Generator Protection Relay Panel | 1 no. |
| CT Panel | 1 no. |
| 415 / 110 V AC, 50 VA PT Panel | 1 no. |
| 5 Pin to Shrouded Socket Converter Panel | 2 nos. |
| Generator Transformer Panel | 1 no. |
| 3 Phase Squirrel Cage Induction Motor Panel | 1 no. |
| 3 Phase Salient Pole Alternator Panel | 1 no. |
Smart Power System Generation Trainer - XPO-SPS-GEN
Experiments:
- Automatic as well as manual synchronization of generator with grid supply
- Study of V curve & inverted V curve
- Study of Generator performance chart
- Study of generator protection for differential, over current, over / under voltage, over / under frequency, reverse power and earth faults using generator protection relay
Features:
- VFD drive is used to control brushless prime mover’s speed in manual using RTU / SCADA as well as in auto mode using synchronization relay
- Multi function meters read the input voltage & frequency of generator output along with power analyser data
- The generator / alternator coupled with prime mover have brought out six terminals from three phase 3 windings (RYBs). Every alternate terminal of RYB is shorted and connected together to form star connection (neutral) at the output of generator
- The relay panel carries shrouded sockets to connect generator protection relay mounted below. The CT panel and PT panel provide necessary interface between real world & relay
- Emergency stop mushroom switch is provided with security key lock on the profile rack
Technical Specifications:
- Input 3 phase DOL Starter panel
- DC Voltmeter & DC Ammeter Panel
- Instrumentation Power Supply cum Multichannel DPM Panel
- Variable AC and DC Supply Panel
- IGBT Controlled VVVF Drive Panel
- 3 Phase Bidirectional Power cum Energy Meter Panel
- SCR Actuator (Variable DC) cum Sensor Signal Conditioning Panel
- Generator Protection Relay Panel
- CT Panel
- 415 / 110 V AC, 50 VA PT Panel
- 5 Pin to Shrouded Socket Converter Panel
- Generator Transformer Panel
- 3 Phase Squirrel Cage Induction Motor Panel
- 3 Phase Salient Pole Alternator Panel
Additional Information:
- Delivery Time: 12 weeks from the date of receipt of order
View Complete Details
Power Engineering Smart Power System Synchronization Trainer
Get Latest Price
Minimum Order Quantity: 1 Set
| Model Name/Number | XPO-SPS-SYNC |
| Usage/Application | Power Generation Smart Power System Synchronization Trainer |
| Country of Origin | Made in India |
| Input 3 Phase DOL Starter Panel | 1 no. |
| Synchronization Panel | 1 no. |
| 3 Phase Bidirectional Power cum Energy Meter Panel | 2 nos. |
| Mesh Bus Generator Panel | 1 no. |
| Mesh Bus Grid Panel | 1 no. |
| Synchronization Bus Switch Panel | 1 no. |
| 415 / 110 V AC, 50 VA PT Panelnel | 2 nos. |
| Phase Angle Meter Panel | 1 no. |
| Synchronization Relay Panel | 1 no. |
| Transmission Line Panel | 1 no. |
| R Load Panel | 1 no. |
| Grid Transformer Panel | 1 no. |
Power Engineering Smart Power System Synchronization Trainer - XPO-SPS-SYNC
Experiments:
- Automatic as well as manual synchronization of generator with grid supply
- Study of V curve & inverted V curve
- Study of Generator performance chart
Features:
- XPO-SPS-SYNC Trainer works only in conjunction with the Generation setup (XPO-SPS-GEN), HMI, RTU SCADA software and various panels
- To synchronize the generator with the grid, this synchronization setup is used
- Automatic operation can be performed in two ways, namely, from screen based generator control panel using increment and decrement screen buttons or using synchronization relay whose 4 contacts (increment and decrement) are read by a RTU through 9 pin D (M) connector on synchronising relay panel & outputs two AO’s through 9 pin D connector on VFD panel and patch cording, one for excitation (V) control and the second for speed (f) control
- Emergency stop mushroom switch is provided with security key lock on the vertical profile member
Specifications:
- Input 3 phase DOL Starter Panel
- Synchronization Panel
- 3 Phase Bidirectional Power cum Energy Meter Panel
- Mesh Bus Generator Panel
- Mesh Bus Grid Panel
- Synchronization Bus Switch Panel
- 415 / 110 V AC, 50 VA PT Panel
- Phase Angle Meter Panel
- 37 pin D (M) to 9 pin D (F) Converter Panel
- 5 pin to Shrouded Socket Converter Panel
- Synchronization Relay Panel
- Transmission Line Panel
- R Load Panel
- Grid Transformer Panel
Additional Information:
- Delivery Time: 12 weeks from the date of receipt of order
View Complete Details
Power Engineering Smart Power System Transmission & Distribution Trainer
Get Latest Price
Minimum Order Quantity: 1 Set
| Model Name/Number | XPO-SPS-TLD |
| Usage/Application | Power Transmission and Distribution Trainer |
| Country of Origin | Made in India |
| Input 3 Phase DOL Starter Panel | 1 no. |
| FWD-OFF-REV Switch Panel | 1 no. |
| 3 Phase Bidirectional Power cum Energy Meter Panel | 3 nos. |
| VAR Compensation Panel (Dual Panel) | 1 no. |
| Differential Relay (Transformer Protection) Panel | 1 no. |
| CT Panel | 2 nos. |
| Distance Protection Relay Panel | 1 no. |
| 415 / 110 V AC, 50 VA PT Panel | 1 no. |
| 37 Pin D (M) to 9 pin D (F) Converter Panel | 1 no. |
| 5 Pin to Shrouded Socket Converter Panel | 2 nos. |
| Distribution Transformer Panel | 1 no. |
| Transmission Line Panel | 1 no. |
| RLC Load Panel | 1 no. |
Power Engineering Smart Power System Transmission & Distribution Trainer - XPO-SPS-TLD
Experiments:
- Study of No Load test and Ferranti effects on transmission line
- Load test and calculation of efficiency, regulation and power flow in pi model of TL
- Load test and calculation of efficiency, regulation and power flow in short model of TL
- Study of symmetrical and asymmetrical faults on transmission line
- Study of distance protection using distance relay
- Study of auto reclose function of distance relay
- Study of distribution transformer protection for differential & over current faults
Additional Information:
- Delivery Time: 12 weeks from the date of receipt of order
View Complete Details
Explore more categories
- Developed and Managed by IndiaMART InterMESH Limited