1
Have a requirement?
Get Best Price
1
Have a requirement?
Get Best Price
Instruments Used For Calibrating
Our range of products include Recovery Test, HEPA Filter Integrity (Leak) Test, Air Velocity And Volumetric Flow Rate Measurement, Air Flow Pattern Test, Calibration Of Magnehelic Gauges / Pressure Gauges and Light Intensity Measurement.
Interested in this product?
Get Best Quote
Recovery Test
Get Latest Price
Demonstrates the ability of the room To remove the particulate by purging the area with Filtered air and than the room can change from a dirty to clean state with in specified time.
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
HEPA Filter Integrity (Leak) Test
Get Latest Price
This test is carried out to check the Hepa filter media Integrity leak test by using aerosol generator (Aerosol Media DOP or PAO) Die octa Pethalate or puly Alfa define and photometer, Compressed air or Nitrogen gas at 20 to 30 PSI Pressure having 10-15 CFM airflow capacity require to generate. The aerosol at upstream port of Hepa filter. We check Upstream concentration before scanning the filter.
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Air Velocity And Volumetric Flow Rate Measurement
Get Latest Price
To measure the airflow velocity across the filter, room Air volume, number of air changes ,check the differential pressure inside the clean room as well equipment used.
Instrument Used :
1) Fan type handheld battery operated Anemometer
model No.: AM-4201, Range 0.4 - 30.0 M/sec 2).
2) Hot wire type Hand held battery operated Anemometer
MODEL No: AM-4204, 0.2-20.0 M/sec 3).
Instrument Used :
1) Fan type handheld battery operated Anemometer
model No.: AM-4201, Range 0.4 - 30.0 M/sec 2).
2) Hot wire type Hand held battery operated Anemometer
MODEL No: AM-4204, 0.2-20.0 M/sec 3).
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Air Flow Pattern Test
Get Latest Price
Filter inside the clean rooms well clean room equipment to determine the air flow direction is positive laminar as per design.
Instrument Used:
i). Titanium Techtra chloride for Generating the smoke
ii)Alternatively :- Smoke generator (fogger) imported which
works on single phase power supply having food grade aerosol
used to generate the adequate smoke,.
Instrument Used:
i). Titanium Techtra chloride for Generating the smoke
ii)Alternatively :- Smoke generator (fogger) imported which
works on single phase power supply having food grade aerosol
used to generate the adequate smoke,.
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Calibration Of Magnehelic Gauges / Pressure Gauges
Get Latest Price
We calibrate the Magnehelic Gauges for differential pressure measurement.
Instrument used.
1) Digital handheld differential pressure manometer calibrator
having range 10 to 500 MMWC Battery operated.
2) Calibration test pressure pump to generate the differential pressure.
3) Comparison Test Pump.
Instrument used.
1) Digital handheld differential pressure manometer calibrator
having range 10 to 500 MMWC Battery operated.
2) Calibration test pressure pump to generate the differential pressure.
3) Comparison Test Pump.
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Light Intensity Measurement
Get Latest Price
By using digital handheld battery operated lux meter. Range 0 to 50,000 Lux,
Additional Information:
- Item Code: LX101A
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Air Borne Particulate Test
Get Latest Price
To Check class of cleanliness .This test provide the classification of the area has been achieved with regard to the concentration of air borne particulate.
View Complete Details
Yes, I am interested!
Tell us what you need, and we’ll help you get quotes
Tell us what you
need
need
Receive seller
details
details
Seal the deal
Pay with IndiaMART