Advanced Power System Lab
Power electric modules. This laboratory is focused on the topic of the generation, the distribution and the utilization of the electrical energy, used for both industry and domestic applications.
The trainer is composed of a set of modules for the simulation of the various subsystems forming a complete electrical power system, from power generation to energy utilization.
It can be subdivided into four major study areas:
- Power Generation
- Power Transmission and Distribution
- Protection Techniques
- Energy Utilization
Usage/Application | For Lab testing and training purpose |
Model Name/Number | TS-NUOC-PC |
Brand | GE |
Type | Current Relay |
Display | 2 line 16 characters industrial grade LCD with back-lit module for numerical display of setting valu |
Ce Certified | CE Certification |
Country of Origin | Made in India |
Numerical Over Current and Earth Fault Relay Trainerwith pc interface
Current Injunction Source
- One number of auto transformer provided for current adjustment
- One number of loading transformer used for current source
- Current output applied to CT.
- One number of digital ammeter used to indicate current
- Specification: current range: 0-20Amp AC. (continuously variable)
- One number of automatic relay tripping time measurement circuit
- One number of start/stop push-to on switch provided for time measurement circuit
- One number of digital timer provided to measure relay tripping time
- One number of reset switch provided for timer reset
- One number of NO contacts @ 220V ,10Amp rating
- One number of NC contacts @ 220V ,10Amp rating
Technical specifications:
Numerical Over Current & Earth Fault Relay
- Single phase, high-set, non-directional Over current relay with instantaneous or definite time function
- Low-set non -directional Earth fault Relay with inverse definite minimum time (IDMT) or definite time characteristics
- Password protection
- 2 line 16 characters industrial grade LCD with back-lit module for numerical display of setting values and measured values which is user friendly
- Trips for default/previously selected curve if the fault occurs during settings of the relay
- Membrane key pad for easy operation, dust
proof front panel
- Enabling /Disabling of High-Set
- LED indications for power, pick-up, phase fault trip or Earth Fault trip for IDMT and High-set
- Relay test facility with relay trip & without relay trip
- Separate heavy duly output contacts provided for time delayed phase fault with high-set and time delayed Earth Fault with high-set
View Complete Details
Usage/Application | Industrial and technical training |
Brand | GE |
Voltage | 5V to 275 V in steps of 1 V |
Model Name/Number | TS-NUOV-PC |
Type | Undervoltage relay |
Voltage Range | 24/30/48/110V DC 18-135VDC - 48/110/220V DC 43-280VDC (or) 110V AC - DC Input |
Voltage Setting | 5V to 275 V in steps of 1 V |
Country of Origin | Made in India |
Numerical under/ over voltage Relay Trainer with pc interface
The relay test bench having
- Have sturdy enclosure with colorful overlays showing circuit diagrams and its connections for easy understanding of students
- Set of instruction working manual
- Stage under/over voltage (27/59)
- Numerical, true RMS measurement
- Wide voltage setting ranges
- Multiple inverse characteristics (160)
Control Panel –
The relay has 8 output contacts
- Trip/alarm for both elements 2 N/O
- Common starter for both elements 1 N/O
- Element 1operated 1 N/O
- Element 2 operated 1 N/O
- Protection Unhealthy 1 N/C
- Timer 1 N/O - Trip circuit fail 1 N/O
- Timer for capacitor bank to switch to safer value before successive switching of the breaker
List of Experiments
- Study & testing of DMT type Over/Under-Voltage Relay with different voltage & time setting
- Study & testing of IDMT type Over/Under-Voltage Relay with differential voltage & time setting
- Plotting of IDMT characteristics of OV/UV relay in PC
- How to program a numerical relay
Detailed manual with theory and practical guidance with tables and charts
View Complete Details
Brand | Technosys |
Relay Type | ELECTROMECHANICAL |
Relay Voltage | 0-300V AC |
Relay Current | 5A |
Model Name/Number | TS-EMOV |
Usage/Application | for technical training, research and teaching purpose |
Country of Origin | Made in India |
Electromechanical overvoltage relay test set
Technical Specification:- It consists of set of associated relay testing sub sets mounted in a light weight sturdy aluminium profile flat demo panel system.
- With the testing kit should be in the main module.
- Facilitates easy and safe wiring using 4mm sturdy shrouded banana patch chords
- Have sturdy enclosure with colourful overlays showing circuit diagrams and its connections for easy understanding of students.
- Have set of instruction working manual.
- Have supplied measuring instrument with data logger
- Have multi-connection (more than one device) supported via mobile app
- Able to provide the change trend analysis accessible via special chart mode
- Voice warning supported, which assures measurement safety
- Accessible with smart voice-reading
- Able to display with + 3(5/6)-digit full scale reading,
- Supports Bluetooth 2.0 version
- Supports mobile device with Android 4.0 or above OS
View Complete Details
Brand | Technosys |
Relay Type | ELECTROMECHANICAL |
Relay Voltage | 0-300V AC |
Relay Current | 0-10A |
Model Name/Number | TS-EMOC |
Usage/Application | for technical training, research and teaching purpose |
Country of Origin | Made in India |
Electromechanical overcurrent relay test set
Technical specifications:
Current Injection Source
• One number of auto transformer provided for current adjustment
• One number of loading transformer used for current source
• Current output applied to CT.
• One number of digital ammeter used to indicate current
• Specification: current range: 0-20Amp AC. (continuously variable)
• One number of automatic relay tripping time measurement circuit
• One number of start/stop push-to on switch provided for time measurement circuit
• One number of digital timer provided to measure relay tripping time
• One number of reset switch provided for timer reset
• One number of NO contacts @ 220V ,10Amp rating
• One number of NC contacts @ 220V ,10Amp rating
View Complete Details
Model Name/Number | TS-DIFF3-PC |
Type | Computer interface |
Phase | Single Phase |
Display | 20x4 LCD Display |
Brand | Technosys |
Technology | Based on DSP Based Digital Algorithms |
Country of Origin | Made in India |
NUMERICAL PERCENTAGE BIASED DIFFERENTIAL RELAY TRAINER - with pc interface
Single/Three -phase Numerical Transformer Protection Relay
- With one number of Single/ Three-phase numerical transformer protection relay
- With Resistive load
- Based on DSP Based Digital Algorithms
- With minimum Trip Time - 30ms
- Password protected
- 20x4 LCD Display
- Power system frequency 50Hz
- Field Configurable CT Secondary 1A or 5A
- Configurable to Dual Slope Characteristic
- Be able to demonstrate Transformer Differential Protection (ANSI CODE: 87)
- With 2 number of output contacts
- Capable to store history of last 20 Events
- Capable to store disturbance record of last 10 Events
- Configurable to Pre and Post Fault Cycles
- With communication Port: Front-RS232 and Rear-RS485
- With communication Protocol: Modbus
- With draw-out facility with inbuilt CT shorting
Technical specifications:
The relay test bench having
• The relay test bench is provided with Software for oscillographic harmonic recording up to max 1200 cycles and programmable Pre fault and Post fault cycles.
• The oscillographic records can be transferred to PC via USB in COMTRADE format.
• Have sturdy enclosure with colorful overlays showing circuit diagrams and its connections for easy understanding of students.
• Detailed manual with theory and practical guidance with tables and charts
1. SINGLE PHASE TRANSFORMER:
- One Number of Single-phase with rating: 200VA, 230/48 V Stepdown transformer is to be provided,
- One Number of Single-phase with rating: 200VA, 24-0-24/ 24-0-24 Open type transformer is to be provided.
2. CONTROL PANEL:
- Digital voltmeter and ammeters in the primary and secondary sides
- Suitable fault resistances.
Capable of studying the various protection schemes of:
1. Three phase transformer.
2. Single Phase Transformer.
Detailed manual with theory and practical guidance with tables and charts
View Complete Details
Usage/Application | For Lab testing and training purpose |
Model Name/Number | TS-DIST1-PC |
Type | Computer interface |
Phase | Single Phase |
Automation Grade | Automatic |
Digital Meter | Digital Panel Voltmeter |
Features | The oscillographic records can be transferred to PC via USB in COMTRADE format |
Brand | Technosys |
Country of Origin | Made in India |
Numerical phase distance protection Relay Trainer WITH COMPUTER INTERFACE
The relay test bench having
- Provided with Software for oscillographic harmonic recording up to max 1200 cycles and programmable Pre-fault and Post-fault cycles.
- The oscillographic records can be transferred to PC via USB in COMTRADE format
- Have sturdy enclosure with colorful overlays showing circuit diagrams and its connections for easy understanding of students.
- Set of instruction working manual.
- Supplied with measuring instrument with data logger
Detailed manual with theory and practical guidance with tables and charts
View Complete Details
Usage/Application | For Lab testing and training purpose |
Model Name/Number | TS-NUDOC-PC |
Type | Computer interface |
Phase | Single Phase |
Automation Grade | Automatic |
Enclosure Type | Have sturdy enclosure with colorful overlays showing circuit diagrams and its connections for easy u |
Brand | Technosys |
Country of Origin | Made in India |
Numerical directional over current Relay Trainer with pc interface
The relay test bench having
- Have sturdy enclosure with colorful overlays showing circuit diagrams and its connections for easy understanding of students
- Set of instruction working manual
- Stage Directional Overcurrent (67)
- Numerical, true RMS measurement
- Wide Current setting ranges
Control Panel –
The relay has 8 output contacts
- Trip/alarm for both elements 2 N/O
- Common starter for both elements 1 N/O
- Element 1operated 1 N/O
- Element 2 operated 1 N/O
- Protection Unhealthy 1 N/C
- Timer 1 N/O - Trip circuit fail 1 N/O
List of Experiments
- Study & testing of DMT type Directional current relay
- Study & testing of IDMT type Directional current relay
- Plotting of characteristics of Directional Overcurrent relay in PC
- How to program a numerical relay
Technical specifications:
- Integrated Relay with cutout and terminals
- Type -Directional over Current Relay,
- CT Input 2A,
- Function IDMT/DMT Curve IDMT/DMT curve,
- Features Self powered / supply 48vdc,
- One number of variable AC current Source of 0-20A,
- One number of Autotransformer is provided to adjust the current output continuously
- Provision to change the direction of current source.,
- One number of digital AC Ammeter (0-30A) /3.5 digit / VERITEK Make to measure the current input in amp,
- One number of Automatic trip time measurement circuit (ATTM Circuit)
- One number START push button in ATTM Circuit,
- One number STOP push button in ATTM Circuit,
- One number LCD - Digital stop Clock in ATTM Circuit to measure relay trip time in S, S/10, S/100,
- One number reset switch in front panel to restart the digital stop clock
- Software to download Disturbance Records
- Disturbance Records (to be available to be plotted in a spreadsheet)
- Disturbance data for further analysis in any Power System analysis tool
- RS232 – USB Converter Included
Detailed manual with theory and practical guidance with tables and charts
View Complete Details
Brand | GE or equivalent |
Display | 4x20 LCD Display |
Channels | - 8 Analog Input Channels configurable as Voltage and Current channels |
Make | Technosys |
Uses and Application | For Technical training , research and teaching purpose |
Country of Origin | Made in India |
Numerical relay development environment system
Technical specifications:
Numerical Relay Development Test Bench abilities
- Implement and test any relay algorithm for applicability in real time environment.
- Take input from software simulated data to have any simulated condition.
- Carry out research.
- Use for simulation of COMTRADE file generated by relay in field.
- Perform the simulation of the developed and coded Relay Algorithm, uploaded through NRDE Setup using RS232 port
- Program the LCD Display, Soft push buttons and Status Indicator LED using RS232 port, provided for data exchange
- Generate the required Voltage and Current Waveform using Computer software and DAC Card provided. The same has to be fed into NRDE Main unit using 8 Analog input channels provided based on the requirements.
- Show the relay operation for respective algorithm and analog inputs using the LCD Display and LED Status indicators.
- Give a stopping input signal using NRDE Relay trip command.
- Fetch digital input to take external trigger command if required by the algorithm.
Software Components of Numerical Relay Development Test Bench
NRDE application
- For configuring NRDE analog channels
- For feeding simulation data to NRDE
• Option to generate steady state waveforms
• Option to read simulation data from text file
- MPLAB X IDE
• Platform for developing the relay algorithm (embedded C language)
- COMTRADE viewer • For viewing COMTRADE files
• For converting COMTRADE file to text file compatible with NRDE
- Pre-defined Firmware libraries in MPLAB - NRDE Hardware initialization
- Instantaneous and RMS value of all channels
- Real and Imaginary components of all channels
- Phase angle computation
- 1ms counter.
- LCD display function
- LED indication function
- Relay trip command function
- External trigger input function
Hardware Components of Numerical Relay Development Test Bench
- DAC card to convert the output of PC-based waveform into analog signals
• 100k sample/s and voltage range of +/- 10 Vp
• PC based waveform through any EMTP type simulation package or from COMTRADE file
- Data acquisition through 8 analog input channels
• Two 3-phase channels
• Two 1-phase channels (can be any analog data)
- The A/D converts analog signal into samples and the Fourier technique to compute the magnitude of the signal - Implementation to be based on very high-speed DSP controller
- Serial interface for programing the relay algorithm
- Output options
• 4x20 LCD Display
• 4 Status LED
• 4 Digital trip command (will stop the input signal)
- Digital trip command to be configured to PC through the DAC card
- Flash memory (planned enhancement)
• Waveform capture – similar to disturbance recorder in relays
• Variable capture – to save the variable in algorithm. Will help to access the performance of the scheme
- Serial port to exchange the files in Flash memory
- Digital inputs
• The algorithm can take external trigger command through this
- Optional GPS time synchronization
View Complete Details
Electrical Measurements
Get Latest Price
Rated Voltage | 380/220 V Y/D |
Rated Voltage In Single Phase | 220 V |
Power Supply | 3x380 V+ N,50/60 Hz |
Output Voltages | AC 220 V,10 A |
Connection | 825 VAr |
Electrical Measurements catalogue has been conceived for the presentation of the De Lorenzo panel type electrical installations laboratories It includes the series DL 2101T, for civil installations, the series DL 2102T, for industrial installations and the series DL 2109T, for the study of electrical measurements The modules composing the laboratories are made of real components assembled on isolated panels for insertion in work frames Unit symbols and standardized mimic diagram are displayed on the front panel and the connections are made via sockets meeting safety standards.
View Complete Details
Heating and Sanitary Plants
Get Latest Price
Net Weight | 124 kg. |
Gross Weight | 283 Kg |
Dimensions | 1.77 x 1 .22 x1.91 m |
Average Training Hours | 8 H |
Heating and Sanitary Plants consists of a set of simulation panels and of demonstrators with real components that allow studying and performing practical tests in refrigeration and air conditioning The simulation panels are supplied with a CAI software that allows students to develop all the learning activities through a PC. If the PCs are connected to a computer network, a laboratory management software allows a complete control by the teacher of all the activities within the laboratory Both the simulation panels and the demonstrators are provided with a fault simulation system.
View Complete Details
Fluid Mechanics Dididactic Simulators
Get Latest Price
Tank Capacity | 250 L |
Motor Speed | 2.900 rpm |
Power Consumption | 750 W |
Maximum Flow Rate | 160 l/min at 10 M WC |
Fluid Mechanics Dididactic Simulators has many applications in various fields, such as naval engineering, aircraft engineering, or the study of blood circulation, and has also many applications in everyday life.The proposed laboratory includes a hydraulic bench full of didactic modules, a number of stand-alone systems that can be used to study the properties of the fluids, the pressure losses, the metacentric height, the cavitation, the Venturi effect, the Bernoulli's theorem, the Reynolds number, the series-parallel pumps etc and a wind tunnel.
View Complete Details
Hydraulic Bench With Accessories
Get Latest Price
High Flow | 40 l/h |
Maximum elevation Height | 250 mm |
Piping | 16 mm Inner |
Fluid mechanics has many applications in various fields, such as naval engineering, aircraft engineering, or the study of blood circulation, and has also many applications in everyday life.
The proposed laboratory includes a hydraulic bench full of didactic modules, a number of stand-alone systems that can be used to study the properties of the fluids, the pressure losses, the metacentric height, the cavitation, the Venturi effect, the Bernoulli's theorem, the Reynolds number, the series-parallel pumps, etc. and a wind tunnel.
View Complete Details
Heat Transfer
Get Latest Price
Power Supply | 230V/50 Hz. |
Maximum Flow | 10 l/min (5M WC) |
Power Consumption | 180 W |
Dimensions | 730 x1100 x530 mm |
Heat Transfer consists of a set of simulation panels and of demonstrators with real components that allow studying and performing practical tests in refrigeration and air conditioning.The simulation panels are supplied with a CAI software that allows students to develop all the learning activities through a PC.
If the PCs are connected to a computer network, a laboratory management software allows a complete control by the teacher of all the activities within the laboratory the simulation panels and the demonstrators are provided with a fault simulation system.
View Complete Details