Power Cables

Pioneers in the industry, we offer L T Aerial Bunched Cable, Instrumentation Cable Polyethylene Insulation Cable and Control Cable from India.

L T Aerial Bunched Cable
Interested in this product?
Get Best Quote

L T Aerial Bunched Cable

Get Latest Price

Application
    Aerial Bunched Cables are suitable for the following functions
  • In power theft prone areas.
  • As replacement of bare lines in rural areas, in woods, other localities & narrow street where space is limited.
  • As replacement of bare lines where reliability of supply is of prime importance and where high degree of stability of supply voltage is of importance.
  • In hilly terrains where cost of erection of overhead lines of under ground cable becomes very high.
  • In hilly terrains where cost of erection of overhead lines of under ground cable becomes very high.
  • As reinforcement of existing system without increasing voltage.
  • For temporary supplies.

Cable Construction Details
Conductor The phase conductor and neutral/street lighting conductors is of H2 or H4 grade aluminium complying with the requirements of IS 8130:1984 and conforms to flexibility class 2 of IS 8130:1984. The size of the street lighting conductor is16 mm2.
Messenger (Neutral Conductor or Otherwise) The conductor is heat treated aluminium- magnesium-silicon alloy wire conforming to IS 398 (Part 4):1979.It is either stranded circular or compacted circular type and has minimum 7 strands with smooth surface.
Insulation The conductor is insulated with crosslinked polyethylene applied by extrusion. The insulation so applied fits closely on the conductor and it is possible to remove without damaging the conductor. The color of insulation is black, offering UV protection.
Core Identification The phase conductors is provided with one, two or three 'ridges' and outer neutral insulated conductor, if provided, has four 'ridges' for quick identification. The street lighting conductor and messenger conductor (if insulated) does not have any identification mark.
Assembly (Laying up) The required number of insulated phase conductors, one insulated neutral conductor (if required) and a street lighting conductor (if required) is twisted around the bare (or insulated) as required messenger conductor without fillers with a lay not exceeding 35times the diameter of the insulated phase conductor. The direction of lay is right hand.

View Complete Details

Yes I'm interested

Instrumentation Cable Polyethylene Insulation Cable
Interested in this product?
Get Best Quote
Cable Construction Details
Operating Voltage :300/500V
Size :Available in following no of pairs : 1, 2 (1 Quad), 5, 10, 15, 20, 30 and 50 Pairs
Conductor:Solid/Stranded/Flexible Annealed Bare/Tinned copper class 1/2/5 to BS:6360
Insulation & Pairing / QuadingConductors are insulated with solid Polyethylene Type 03 as per BS:6234, uniformly twisted together to form a pair / quad with a max. lay length of 100 mm, and colour coded for identification.
Colour Code:As per BS:5308 Part-1
Pair shield(for individual pair Shielded cables only)Each twisted pair shielded with aluminium backed polyester tape and a tinned copper drain wire of size 0.5mm² .
AssemblyTwister pairs are cabled with nonhygroscopic fillers if necessary
Overall shieldThe entire assembly is shielded with aluminium polyester tape and a tinned copper drain wire of size 0.5mm².
Bedding:(applicable for Type 2 Cables)Extruded Black Polyethylene Type 2 C or 03 as per BS:6234.
Wire Armouring (applicable for Type 2 Cables)A serving of round galvanized steel wires as per BS:1442 is applied.
SheathType - 1 & 2 Extruded Black PVC Type TM1 of BS:6746.

View Complete Details

Yes I'm interested

Control Cable
Interested in this product?
Get Best Quote

Control Cable

Get Latest Price

Cable Construction Details
Voltage : These cables can be used on AC voltage up to & Including 1100 V or DC up to & including 1500 V.
Size : 1.5 Sq.mm. & 2.5 Sq.mm. upto 37 Cores
Conductor: Annealed Bare Electrolytic Copper/ Aluminum Conductor conforming to IS:8130:1984.
Insulation: Conductors are insulated with PVC Compound as per IS:5831:1984.
Colour of Cores: Cores are identified with a colour scheme as per IS:1554 (pt-1):1988 as under
2 Cores - Red & Black
3 Cores - Red, Yellow & Blue
3½ & 4 Cores - Red, Yellow, Blue & Black (Reduced Neutral Core in case of 3½ Core).
5 Cores - Red, Yellow, Blue, Black and Grey
In case of cable exceeding five cores, two adjacent (counting and direction cores) in each layer shall be colored Blue, Yellow and remaining cores grey, or identification by numbers printed over insulation as per IS:1554 (pt-1):1988
Laying of Cores: Cores are laid up with a suitable lay. The final layer direction shall be kept right hand lay
Inner Sheath: The Inner Sheath is applied over laid up of cores by extrusion/wrapping of thermoplastic material.
Armouring: It is applied over inner sheath. It may consist of galvanized Round Steel wires or galvanized Flat Steel Strips conforming to IS 3975. Round Wire armouring is provided, where the calculated diameter under armour is 13.0 mm. Above this, armouring is either round wire/steel strip.
Outer Sheath: A final covering of PVC Compound, conforming to IS:5831:1984, is applied over Armouring in case of Armoured Cable or over Inner Sheath in case of Unarmoured cable, called as “Outer Sheath”.
The Insulation, Inner Sheath or Outer Sheath can be HR PVC, FRLS PVC or FRHF Compound , depending upon their application.

View Complete Details